Radiofrequency interference with medical devices. A technical information statement.

Abstract

The past few years have seen increased reports that medical devices, such as pacemakers, apnea monitors, electrically powered wheelchairs, etc., have failed to operate correctly because of interference from various emitters of radiofrequency energy. This condition is called radiofrequency interference (RFI). The consequences of these failures range from inconvenience to serious injuries and death. Reasons for this problem are twofold: 1) increasing numbers of electronically controlled medical devices with inadequate electronic protection against RFI, and 2) a significant increase in the number of RF sources in the environment. Medical devices are widely used outside the hospital and may be attached to, or implanted in, patients. Portable wireless communications equipment, including cellular phones, handheld transceivers, and vehicle-mounted transceivers, comprise one of the largest sources of RFI. Some medical devices are especially sensitive to the type of digital modulation that some of the wireless communications devices utilize. The prevailing international standard for the RF immunity of medical devices is the 1993 revision of the International Electro-technical Commission (IEC) Standard IEC 60601-1-2. This standard sets a minimum immunity level of 3 volts per meter (V/m) in the 26-1000 MHz frequency range. For non-life supporting devices, testing is required only at the specific frequencies of 27.12, 40.68, and 915 MHz. Technology exists to protect, or "harden," most medical devices from RF fields that are much more intense than the 3 V/m level specified in present RFI standards. Most of these techniques, including shielding, grounding, and filtering, are not costly if they are incorporated into the initial design of the electronics system. COMAR recommends that the various parties involved in the manufacture and use of RFI-prone medical devices take steps to avoid serious RFI problems that may lead to safety hazards. Medical device manufacturers should design and test their products to ensure conformance with current RFI standards and educate the users of their devices about the possible symptoms of potential RFI. If there exists the possibility of RFI problems to medical devices, steps should be taken to ensure that all sources of RF energy be kept at a sufficient distance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Radiofrequency interference with medical devices. A technical information statement.. https://pubmed.ncbi.nlm.nih.gov/9604711/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dual-trap technique for reduction of low-frequency noise in force measuring optical tweezers.

High-resolution long-time force measurements by optical tweezers are often limited by low-frequency (1/f) noise. A dual-trap technique is presented that can reduce such noise in the force signal. It incorporates a second trap (a reference trap) that probes the noise in the system and it is based upon the assumption that the low-frequency parts of the noise from the two traps are correlated. A subtraction of the low-frequency signal from the reference trap from the signal from the force measuring trap will therefore yield a net signal that is significantly less influenced by noise. It is shown that this dual-trap technique can reduce the noise in the force signal up to 60% depending on detection bandwidth.

Equipment Design↗

Optimization of doses received by the hospital staff and the members of the family of patients undergoing 111In-DTPA-D-Phe1-Octreotide therapy.

According to the Euratom Directives (96/29, 97/43), the doses received by the workers as well as the family of patients and third persons during medical exposures, should conform to the dose constraint levels (DCLs), established by the authorities for each group in the context of optimisation. This study deals with the implementation of a radiation protection protocol, concerning the aforementioned group members for patients undergoing treatment with 111In-DTPA-D-Phe1-Octreotide, after intra-arterial infusion. It is shown that by applying this protocol the annual doses to the medical and technical staff are considerably reduced and remain below the established DCLs. Following the post-release behaviour instructions given to the patient, doses to the family and third persons may be kept lower than the corresponding DCLs provided by the National Regulations.

Equipment Design↗

In vivo myograph measurement of muscle contraction at optimal length.

BACKGROUND: Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. METHODS: We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. RESULTS: In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. CONCLUSION: We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

Equipment Design↗