Errors in biased estimators for parametric ultrasonic imaging.

Abstract

Maximum likelihood (ML) methods are widely used in acoustic parameter estimation. Although ML methods are often unbiased, the variance is unacceptably large for many applications, including medical imaging. For such cases, Bayesian estimators can reduce variance and preserve contrast at the cost of an increased bias. Consequently, including prior knowledge about object and noise properties in the estimator can improve low-contrast target detectability of parametric ultrasound images by improving the precision of the estimates. In this paper, errors introduced by biased estimators are analyzed and approximate closed-form expressions are developed. The task-specific nature of the estimator performance is demonstrated through analysis, simulation, and experimentation. A strategy for selecting object priors is proposed. Acoustic scattering from kidney tissue is the emphasis of this paper, although the results are more generally applicable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Chaturvedi, M F Insana. 1998. Errors in biased estimators for parametric ultrasonic imaging.. https://doi.org/10.1109/42.668694

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Hybridization enhancement using cavitation microstreaming.

Conventional DNA microarray hybridization relies on diffusion of target to surface-bound probes, and thus is a rate-limited process. In this paper, a micromixing technique based on cavitation microstreaming principle that was developed to accelerate hybridization process is explained. Fluidic experiments showed that air bubbles resting on a solid surface and set into vibration by a sound field generated steady circulatory flows, resulting in global convection flows and, thus, rapid mixing. The time to fully mix dyed solutions in a 50-microL chamber using cavitation microstreaming was significantly reduced from hours (a pure diffusion-based mixing) to 6 s. Cavitation microstreaming was implemented to enhance DNA hybridization in both fluorescence-detection-based and electrochemical-detection-based DNA microarray chips. The former showed that cavitation microstreaming results in up to 5-fold hybridization signal enhancement with significantly improved signal uniformity, as compared to the results obtained in conventional diffusion-based biochips for a given time (2 h). Hybridization kinetics study in the electrochemical detection-based chips showed that acoustic microstreaming results in up to 5-fold kinetics acceleration. Acoustic microstreaming has many advantages over most existing techniques used for hybridization enhancement, including a simple apparatus, ease of implementation, low power consumption (approximately 2 mW), and low cost.

Acoustics↗

Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response.

Theoretical and experimental aspects of two-dimensional (2D) biomedical photoacoustic imaging have been investigated. A 2D Fourier-transform-based reconstruction algorithm that is significantly faster and produces fewer artifacts than simple radial backprojection methods is described. The image-reconstruction time for a 208 x 482 pixel image is approximately 1 s. For the practical implementation of 2D photoacoustic imaging, a rectangular detector geometry was used to obtain an anisotropic detection sensitivity in order to reject out-of-plane signals, thereby permitting a tomographic image slice to be reconstructed. This approach was investigated by the numerical modeling of the broadband directional response of a rectangular detector and imaging of various spatially calibrated absorbing targets immersed in a turbid phantom. The experimental setup was based on a Q-switched Nd:YAG excitation laser source and a mechanically line-scanned Fabry-Perot polymer-film ultrasound sensor. For a 800 microm x 200 microm rectangular detector, the reconstructed image slice thickness was 0.8 mm up to a vertical distance of z = 3.5 mm from the detector, increasing thereafter to 2 mm at z = 10 mm. Horizontal and vertical spatial resolutions within the reconstructed slice were approximately 200 and 60 microm, respectively.

Acoustics↗

Effects of body position on snoring in apneic and nonapneic snorers.

STUDY OBJECTIVES: The positional dependency of obstructive sleep apnea (OSA) is well known, but objective evidence for the positional effect on snoring is lacking. The aim of this study is to elucidate the effect of body position on snoring, and that of sleep stage as well. DESIGN: Retrospective analysis of the effects of body position and sleep stage on snoring in nonapneic snorers (snorer group) and OSA patients (apneic group). SETTING: A sleep laboratory in a national hospital in Japan. PATIENTS: Seventy-two patients who complained of habitual snoring and underwent overnight polysomnography. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: In the lateral position, most subjects in the snorer group showed decreased snoring both in time (p = 0.0004) and intensity (p = 0.0003), but subjects in the apneic group showed variable changes. In the apneic group, the positional dependency of snoring (the ratio of lateral value to supine value) was correlated with supine apnea-hypopnea index (AHI), that is, OSA patients with higher supine AHI tended to show increased snoring in the lateral position. AS to the effect of sleep stage, snoring was increased in deeper non-rapid eye movement sleep and decreased in rapid eye movement sleep in a given position. CONCLUSIONS: This study demonstrated that the positional dependency is different between nonapneic snorers and OSA patients. Most of the nonapneic snorers snore less in the lateral position than in the supine position in contrast to OSA patients who often fail to decrease snoring even in the lateral position.

Acoustics↗