PubMed Health⌕ Search

PubMed · 9625621

Three-dimensional skeletal visualisation with spiral computed tomography.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Smet. 1998. Three-dimensional skeletal visualisation with spiral computed tomography.. https://pubmed.ncbi.nlm.nih.gov/9625621/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Two distinct cellular mechanisms of osteoclast formation and bone resorption in periprosthetic osteolysis.

PURPOSE: TNFalpha and IL-1alpha are proinflammatory cytokines that are abundant in periprosthetic tissues. These cytokines stimulate bone resorption and have recently been shown to directly induce osteoclast formation in mouse marrow cultures. We examined whether TNFalpha and IL-1alpha can directly induce osteoclast formation from human arthroplasty-derived (CD14(+)) macrophages by a mechanism independent of RANKL-induced osteoclastogenesis. METHODS: TNFalpha and M-CSF (+/-IL-1alpha) were added to cultures of magnetically sorted (CD14(+)) and unsorted (CD14(+)/CD14(-)) cells isolated from the pseudomembrane of loosened hip arthroplasties. Osteoprotegerin (OPG), RANK:Fc and antibodies to TNF receptors (p55 and p75) were added to these cultures to distinguish the pathway of osteoclastogenesis. Osteoclast differentiation was assessed by expression of tartrate-resistant acid phosphatase (TRAP), vitronectin receptor (VNR) and lacunar resorption. RESULTS: The addition of TNFalpha (+/-IL-1alpha) resulted in differentiation of CD14(+) macrophages into TRAP(+) and VNR(+) multinucleated cells capable of extensive lacunar resorption. Both OPG and RANK:Fc (which inhibit RANKL-induced osteoclastogenesis) did not block osteoclastogenesis. The addition of antibodies directed against the p55 receptor subunit of TNF resulted in significant inhibition of osteoclast formation and lacunar resorption. CONCLUSIONS: Our results indicate that, in the presence of M-CSF, TNFalpha is sufficient for inducing human osteoclast differentiation from arthroplasty macrophages and that TNFalpha acts synergistically with IL-1alpha to stimulate lacunar resorption. This process is distinct from the RANK/RANKL signalling pathway and is likely to operate in periprosthetic tissues when there is heavy wear particle deposition and cytokine production.

Acetabulum↗

[Multislice CT (MSCT) in the detection and classification of pelvic and acetabular fractures].

PURPOSE: To assess the usefulness of MSCT in the detection and classification of pelvic and acetabular fractures. MATERIALS AND METHODS: Routine radiographs and MSCT of the pelvis with sagittal and coronal multiplanar reconstruction (MPR) were performed in 50 patients with clinically suspected pelvic or acetabular fractures. One trauma surgeon and a radiologist evaluated routine radiographs and CT images in terms of fracture detection, classification and visualization. The AO classification of fractures was used. RESULTS: MSCT excluded a suspected fracture in 15 patients. In the remaining 35 patients, 19 anterior pelvic ring fractures, 10 anterior and posterior pelvic ring fractures, 8 acetabular fractures and 4 sacral fractures were diagnosed. All MSCT diagnoses were made from the axial source images. In 7 (17 %) patients, MSCT detected additional fractures (2 acetabular and 5 posterior pelvic ring fractures) not seen on conventional radiographs. In 3 other patients, MSCT changed the fracture classification by delineating the full extent of the fracture. MPR visualized 7 acetabular and 4 sacral fractures better than the axial source images. CONCLUSIONS: MSCT of the pelvis is needed for correct fracture detection and classification and has therapeutic consequences.

Acetabulum↗

Device for accurately siting the acetabular component during total hip replacement.

INTRODUCTION: In this paper we describe a device which allows consistent acetabular cup placement to reduce post-arthroplasty dislocation. PATIENTS AND METHODS: The development of this surgical appliance is traced from the initial concept to the construction of a device suitable for clinical trials. The system of use is explained. The constraints imposed by the working environment and the methods employed to meet the demands imposed by surgical practice are elucidated. A clinical trial is described in which the device was used to assist in siting acetabular cup placement in ten patients. RESULTS: The accuracy of the ten cup placements done using the device was then compared by radiography with the accuracy of placement of 17 acetabular cups performed in the standard manner. Comparison of the results show a positive benefit arising from using the device. CONCLUSIONS: Our initial good results on cup positioning in laboratory studies are maintained in a clinical setting, but further modifications could lend to even better results.

Acetabulum↗