Abstract

A planar array immunosensor, equipped with a charge-coupled device (CCD) as a detector, was used to simultaneously detect 3 toxic analytes. Wells approximately 2 mm in diameter were formed on glass slides using a photoactivated optical adhesive. Antibodies against staphylococcal enterotoxin B (SEB), ricin, and Yersinia pestis were covalently attached to the bottoms of the circular wells to form the sensing surface. Rectangular wells containing chicken immunoglobulin were used as alignment markers and to generate control signals. After removing the optical adhesive, the slides were mounted over a scientific grade CCD operating at ambient temperature in inverted (multipin phasing) mode. A two-dimensional graded index of refraction lens array was used to focus the sensing surface onto the CCD. Solutions of toxins were then placed on the slide. After rinsing, Cy5-labeled antibodies were introduced. The identity and amount of toxin bound at each location on the slide were determined by quantitative image analysis. Concentrations as low as 25 ng/mL of ricin, 15 ng/mL of pestis F1 antigen, and 5 ng/mL of SEB could be routinely measured.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R M Wadkins, J P Golden, L M Pritsiolas, F S Ligler. 1998-03-01. Detection of multiple toxic agents using a planar array immunosensor.. https://doi.org/10.1016/s0956-5663(97)00113-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

From host response to genomic targets: electrochemical biosensing of tuberculosis biomarkers.

Tuberculosis (TB) remains one of the leading causes of death from a single infectious agent worldwide, with timely diagnosis continuing to be a major challenge, particularly in resource-limited settings. Conventional TB diagnostic methods are limited by low sensitivity, long turnaround times, and an inability to reliably differentiate latent from active disease. Biomarker-based diagnostic strategies have therefore gained increasing attention as they offer the potential to improve early detection, disease differentiation, and treatment monitoring. Herein, we examine electrochemical biosensing strategies for TB diagnostics using a biomarker-class-driven framework, covering host-response biomarkers (IFN-γ and TNF-α), pathogen-derived antigens (ESAT6, CFP10, CFP10-ESAT6, MPT64, Ag85, HspX and LpqH), cell-wall signatures and whole-cell markers (LAM and whole cell Mtb), and genomic markers (Mtb DNA and IS6110). Through structured comparison of recognition elements, biointerface designs, signal amplification strategies, electrochemical techniques, matrices, and validation levels, this review identifies the most promising technical approaches for different TB biomarker classes. It further highlights key translational bottlenecks, including limited clinical validation, buffer-based testing, complex multistep amplification, redox-probe dependence, matrix fouling, and insufficient evidence of manufacturability. This review therefore provides practical guidance for developing electrochemical TB biosensors that are analytically sensitive, clinically relevant, and suitable for decentralized diagnostic applications.

Biosensing Techniques

Metal-organic frameworks nanozyme-integrated portable microneedle patch for visual bacterial monitoring in meat.

Foodborne microbial contamination is a major global health concern, with conventional methods often being time-consuming and complex. Herein, we developed a novel portable biosensor by integrating microneedle patch technology and a metal-organic framework (Fe/Cu-NBDC MOF) nanozyme, enabling rapid, on-site, visual detection of bacteria in meat. The sensing system works by encapsulating aptamer-functionalized MOF nanozymes within a hydrogel patch, where their catalytic sites are initially blocked by the aptamer. In the presence of Staphylococcus aureus (S. aureus) as the target, the specific aptamer's binding to bacteria exposes numerous catalytic sites, further activating the chromogenic reaction of the tetramethylbenzidine‑hydrogen peroxide (TMB-H₂O₂) system, enabling visual detection of S. aureus. The biosensor demonstrates a detection limit of 82 CFU/mL with excellent specificity to successfully apply to commercial mutton. By integrating sampling, enrichment, and visual detection into a single compact device, this platform offers a practical, efficient solution for rapid on-site screening of foodborne pathogens.

Biosensing Techniques

A biotinylated conducting polypyrrole for the spatially controlled construction of an amperometric biosensor.

A new biotin derivative functionalized by an electropolymerizable pyrrole group has been synthesized. The electrooxidation of this biotin pyrrole has allowed the formation of biotinylated conducting polypyrrole films in organic electrolyte. Gravimetric measurements based on a quartz crystal microbalance, modified by the biotinylated polymer, revealed an avidin-biotin-specific binding at the interface of polymer-solution. The estimated mass increase corresponded to the anchoring of 1.5 avidin monolayers on the polypyrrole surface. In addition, the subsequent grafting of biotinylated glucose oxidase was corroborated by electrochemical permeation studies. Enzyme multilayers composed of glucose oxidase or polyphenol oxidase were elaborated on the electrode surface modified by the biotinylated polypyrrole film. The amperometric response of the resulting biosensors to glucose or catechol has been studied at +0.6 or -0.2 V vs SCE, respectively.

Biosensing Techniques