PubMed HealthSearch

PubMed · 9646351

[Native tissue harmonic imaging].

Abstract

Native Tissue Harmonic Imaging is a new way of ultrasound image processing that addresses the difficult-to-image patient. By using a Gaussian shaped transmit pulse it is possible to separate from the returning echo the harmonic component without overlapping with fundamental reflections. The improved image quality leads to higher diagnostic confidence so that the use of further imaging modalitites is unnecessary.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Schoelgens. 1998. [Native tissue harmonic imaging].. https://doi.org/10.1007/s001170050375

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts

Technical issues for MRI examination of the spinal cord.

Examination of the spinal cord by magnetic resonance imaging is discussed with respect to modern techniques and equipment. Care must be taken in protocol design to maximize resolution and signal strength while providing diagnostic contrast. Artifacts, including truncation, magnetic susceptibility, and those due to motion, may be present and strategies for their mitigation are discussed in this review.

Artifacts

Technical issues for MRI examination of the posterior fossa.

Examination of the posterior fossa by magnetic resonance imaging is discussed with respect to modern techniques and equipment, and including recent results of non-conventional studies in multiple sclerosis. Optimal protocol design will maximize resolution and signal strength while providing diagnostic contrast. Motion artifact from the sigmoid and transverse sinuses may appear as ghosting and can be mitigated with proper imaging parameter choices.

Artifacts