Basics of flow cytometry.

Abstract

In summary, a beginner requires fundamental knowledge about flow cytometric instrumentation in order to effectively use this technology. It is important to remember that flow cytometers are very complex instruments that are composed of four closely related systems. The fluidic system transports particles from a suspension through the cytometer for interrogation by an illumination system. The resulting light scattering and fluorescence is collected, filtered, and converted into electrical signals by the optical and electronics system. The data storage and computer control system saves acquired data and is also the user interface for controlling most instrument functions. These four systems provide a very unique and powerful analytical tool for researchers and clinicians. This is because they analyze the properties of individual particles, and thousands of particles can be analyzed in a matter of seconds. Thus, data for a flow cytometric sample are a collection of many measurements instead of a single bulk measurement. Basic knowledge of instrumentation is a tremendous aid to designing experiments that can be successfully analyzed using flow cytometry. For example, it is important to know the emission wavelength of the laser in the instrument that will be used for analysis. This wavelength is critical knowledge for selecting probes. It is also important to understand that a different range of wavelengths is detected for each fluorescent channel. This will aid selection of probes that are compatible with the flow cytometer. Understanding the complication that emission spectra overlap contributes to detection can be used to guide fluorochrome selections for multicolor analysis. All of these experiment design considerations that rely on knowledge of how flow cytometers work are a very practical and effective means of avoiding wasted time, energy, and costly reagents. Data analysis is a paramount issue in flow cytometry. Analysis includes interpreting as well as presenting data that has been stored in list-mode files. Data analysis is very graphically oriented. There are a number of types of graphic representation that are available to visually aid data analysis. Two standard types of displays are used. These data plots are one-parameter histograms and bivariate plots. A user must be familiar with these two fundamental types of display in order to effectively analyze data. Histograms are the most simple modes of data representation. Histograms allow visualization of a single acquired parameter. Mean fluorescence and distributional statistics can be obtained based on markers that the user can graphically set on the plot. Percentages of positively expressing particles relative to a control sample can also obtained in a similar manner. In addition, multiple histograms can be overlayed on one another to depict qualitative and quantitative differences in two or more samples. Two-parameter data plots are somewhat more complicated than histograms; however, they can yield more information. Two-parameter dot plots of FSC vs SSC allow visualization of both light-scattering parameters that are important for identifying populations of interest. Bivariate fluorescent plots allow discrimination of dual-labeled populations that might remain hidden if histograms were used to display fluorescent data. Two-parameter plots that combine one light-scattering parameter and a fluorescent parameter are useful for analyzing control samples to elucidate the origin of nonspecific binding. Data analysis is very graphically oriented. Experience and pattern recognition become important when using two-parameter data plots for qualitative as well as quantitative analysis. The technique of gating or drawing regions on dual parameter light-scatter plots allows one to exclude information and examine the population of interest by disallowing particles that might confound or interfere with analysis. This is one of the fundamental uses for gating. (ABSTRACT TRUNCATED)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Radcliff, M J Jaroszeski. 1998. Basics of flow cytometry.. https://doi.org/10.1385/0-89603-354-6%3A1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Protocol for Detecting and Sequencing Chikungunya Virus from Field-Collected Mosquitoes.

Arboviral diseases represent a major public health challenge, especially in tropical regions where environmental conditions may favor the proliferation and spread of mosquito vectors. Thus, early and accurate detection of chikungunya virus (CHIKV) in mosquito populations can be a valuable tool for effective surveillance of circulating variants and for identifying new viral introductions. Given the challenges of detecting arboviruses in field-captured mosquitoes, we describe an integrated workflow for CHIKV molecular detection and whole-genome sequencing. This protocol includes mosquito homogenization using a bead-based mechanical disruptor, RNA extraction using TRIzol reagent with minor modifications, molecular screening using CHIKV-specific RT-qPCR, and whole-genome amplification followed by sequencing on Illumina platforms. Despite the protocol being optimized for individual mosquitoes, it results in high-quality RNA suitable for both entomological surveillance and genomic analysis. As this protocol allows recovery of complete CHIKV genomes from mosquito specimens, it can serve as a basis for genomic epidemiology studies, enabling monitoring of viral diversity and lineage dynamics, and facilitating early detection of emerging variants to support timely and targeted public health interventions in endemic and at-risk regions.

Animals↗

Genomic Profiling of Chromatin State Using CUT&Tag.

Alterations in chromatin state, mediated through histone modifications and the incorporation of histone variants, are fundamental to establishing transcriptional networks and cell identity. Recent advances in low-input epigenome profiling methods, such as CUT&Tag and CUT&RUN, have enabled the study of chromatin states from very limited starting materials. In this chapter, we describe procedures for generating CUT&Tag libraries to profile histone modifications and histone variants in early-developing zebrafish embryos.

Animals↗

Relaxin-2: Shaping the Proteomic Landscape of Skeletal Muscle Physiology, Glucose Trafficking, and Mitochondrial Function in Rat.

Relaxin-2 is a hormone with robust beneficial effects on the heart and blood vessels and potential as a therapy for cardiovascular (CV) disease. Considering the interorgan communication between skeletal muscle and heart, and the relation between muscle quality/composition and CV events, we hypothesize that relaxin-2 may regulate skeletal muscle physiology and metabolism. We aim to evaluate the impact of relaxin-2 on the proteome of skeletal muscle from healthy Sprague-Dawley rats. Animals were treated with 0.4 mg/kg/day of serelaxin (recombinant form of human relaxin-2) or vehicle (PBS) for 2 weeks employing subcutaneous osmotic minipumps. Skeletal muscle protein identification and quantification were performed by LC-MS/MS using a Data-Independent Acquisition (DIA)-Sequential Window Acquisition of All Theoretical Fragment Ion Spectra (SWATH) method. SWATH/MS quantitative analysis identified that relaxin-2 significantly decreased 95 proteins and significantly increased 32 proteins in rat skeletal muscle when compared to control rats. From these, 34 proteins were associated with muscle function, myogenesis, muscle differentiation and/or regeneration, 20 are mitochondrial proteins (six from the complexes of the electron transport chain), and 10 proteins participate in glucose metabolism. Qualitative data-dependent workflow analysis identified 35 proteins exclusive to the skeletal muscle of the relaxin-2-treated group: eight proteins related to processes of skeletal muscle function (size, ion homeostasis or organization of caveolae structures and cytoskeleton) and myogenesis, and two proteins involved in muscle differentiation. Our work highlighted for the first time the role of relaxin-2 in crucial processes of muscle physiology and energetic metabolism, which could influence several processes involved in myopathy and CV.

Animals↗