Optimizing data acquisition and analysis of morphometric X-ray absorptiometry.

Abstract

Morphometric X-ray absorptiometry (MXA) uses dual-energy X-ray absorptiometry (DXA) scanners to perform vertebral morphometric measurements of the vertebrae. In this study we evaluated the four available MXA scan modes--single-energy (SE) and dual-energy fast (F), array (A) and high definition (HD)--on a commercial bone densitometer (Hologic QDR-4500A). Sixty postmenopausal women (mean age 59 years, range 40-73 years) were recruited and split into two groups matched for body mass index (BMI, kg/m2). Three MXA scans, covering 13 vertebrae from T4 to L4, were acquired on each subject; all subjects were scanned in SE and A modes, while the third scan was performed in F mode in group 1 and in HD mode in group 2. Subjects were invited to return 6 months after the commencement of the study to repeat their scans. The HD mode produced the most reliable image, with 97% of all scans analyzable to T7 and the fewest vertebrae being lost to analysis (1.5/13 vertebrae lost per scan). A SE + HD combination (using whichever image allows the analysis of more vertebrae) further decreased the number of vertebrae lost to 0.8 of 13 vertebrae, i.e. a typical scan was analyzable up to and including T5. BMI had a noticeable and scan-mode-dependent effect on MXA image quality, an increase in the number of vertebrae lost to analysis occurring once BMI exceeded 30. BMD had a far smaller effect on image quality and no effect at all using the SE + HD combination. Precision (CV%) was similar for all three dual-energy modes at around 3.5% without the scan 'compare' facility and 2.6% with it. The best precision was obtained with SE scan (2.7%/2.2%). BMI and BMD had little or no effect on precision. We conclude that optimal results are obtained by the acquisition of both SE and HD scans. However, for rapid assessment by trained operators SE scans alone offer almost equal utility.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Rea, P Steiger, G M Blake, I Fogelman. 1998. Optimizing data acquisition and analysis of morphometric X-ray absorptiometry.. https://doi.org/10.1007/bf02672516

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗