Horizontal distance and height determining falling pattern.

Abstract

Falling from a height, usually from a building, occurs ordinarily in suicide, in some accidents, and sometimes as an act of homicide. The point of trajectory, the horizontal distance and the impact point are closely related to the initial velocity, angle and height. This study examines the falling pattern in order to determine the mental status of the jumper as well as the manner of death. Initial velocity is found using horizontal movement and height. A serial study of athletes performing both the running jump (long jump) and standing jump (swimmer's start jump) via biomechanical methods is described. The initial velocity of the running jump and standing jump in normal athletics is 9.15 and 2.70 m/s with initial jumping angles of 21 and 38 deg, respectively. The maximal horizontal velocity of 9.15 m/s is closely related to maximal strength of initial velocity, angle of engaged force, and height. Theoretical estimation of the initial velocity between 2.70 and 9.15 m/s is correlative with the unique initial velocity and running jump to fall from a height that is closely related to the voluntary and attempted jump. Hence, the jumping victim with an initial velocity higher than 2.70 m/s implies suicide. These results indicate that horizontal distance and height are legitimate measures to use in speculating on the falling pattern and the manner of death. A unique case of suicide involving a run and jump with initial velocity greater than 2.70 m/s is illustrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K P Shaw, S Y Hsu. 1998. Horizontal distance and height determining falling pattern.. https://pubmed.ncbi.nlm.nih.gov/9670497/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Humans use internal models to estimate gravity and linear acceleration.

Because sensory systems often provide ambiguous information, neural processes must exist to resolve these ambiguities. It is likely that similar neural processes are used by different sensory systems. For example, many tasks require neural processing to distinguish linear acceleration from gravity, but Einstein's equivalence principle states that all linear accelerometers must measure both linear acceleration and gravity. Here we investigate whether the brain uses internal models, defined as neural systems that mimic physical principles, to help estimate linear acceleration and gravity. Internal models may be used in motor contro, sensorimotor integration and sensory processing, but direct experimental evidence for such models is limited. To determine how humans process ambiguous gravity and linear acceleration cues, subjects were tilted after being rotated at a constant velocity about an Earth-vertical axis. We show that the eye movements evoked by this post-rotational tilt include a response component that compensates for the estimated linear acceleration even when no actual linear acceleration occurs. These measured responses are consistent with our internal model predictions that the nervous system can develop a non-zero estimate of linear acceleration even when no true linear acceleration is present.

Acceleration

Visual motion analysis for pursuit eye movements in area MT of macaque monkeys.

We asked whether the dynamics of target motion are represented in visual area MT and how information about image velocity and acceleration might be extracted from the population responses in area MT for use in motor control. The time course of MT neuron responses was recorded in anesthetized macaque monkeys during target motions that covered the range of dynamics normally seen during smooth pursuit eye movements. When the target motion provided steps of target speed, MT neurons showed a continuum from purely tonic responses to those with large transient pulses of firing at the onset of motion. Cells with large transient responses for steps of target speed also had larger responses for smooth accelerations than for decelerations through the same range of target speeds. Condition-test experiments with pairs of 64 msec pulses of target speed revealed response attenuation at short interpulse intervals in cells with large transient responses. For sinusoidal modulation of target speed, MT neuron responses were strongly modulated for frequencies up to, but not higher than, 8 Hz. The phase of the responses was consistent with a 90 msec time delay between target velocity and firing rate. We created a model that reproduced the dynamic responses of MT cells using divisive gain control, used the model to visualize the population response in MT to individual stimuli, and devised weighted-averaging computations to reconstruct target speed and acceleration from the population response. Target speed could be reconstructed if each neuron's output was weighted according to its preferred speed. Target acceleration could be reconstructed if each neuron's output was weighted according to the product of preferred speed and a measure of the size of its transient response.

Acceleration

Three-dimensional measurement of essential tremor.

A mechanical linkage device was used to measure the three-dimensional position of the fingertip during a postural task. Thirty patients with essential tremor were tested simultaneously with the device, uniaxial accelerometry, and clinical tremor measures. Eighteen patients were tested again 16+/-4 days later. The device accurately recorded the three-dimensional behavior of essential tremor. Measures from the device included mean three-dimensional velocity, mean three-dimensional dispersion, and power of the three-dimensional acceleration. The logarithms of these measures were strongly correlated (r = .841-.984) with all clinical measures including self-reported tremor disability. The device measures were reliable within and between testing sessions (intraclass correlation coefficients = .971-.977). The performance of the device was superior to uniaxial accelerometry, most likely as a result of the three-dimensional nature of the measurements. We conclude that essential tremor can be validly and reliably quantified during a postural task providing the recording device records movement in three dimensions and the measurements are logarithmically transformed.

Acceleration