Hydration force in the atomic force microscope: A computational study.

Abstract

Using a hard sphere model and numerical calculations, the effect of the hydration force between a conical tip and a flat surface in the atomic force microscope (AFM) is examined. The numerical results show that the hydration force remains oscillatory, even down to a tip apex of a single water molecule, but its lateral extent is limited to a size of a few water molecules. In general, the contribution of the hydration force is relatively small, but, given the small imaging force ( approximately 0.1 nN) typically used for biological specimens, a layer of water molecules is likely to remain "bound" to the specimen surface. This water layer, between the tip and specimen, could act as a "lubricant" to reduce lateral force, and thus could be one of the reasons for the remarkably high resolution achieved with contact-mode AFM. To disrupt this layer, and to have a true tip-sample contact, a probe force of several nanonewtons would be required. The numerical results also show that the ultimate apex of the tip will determine the magnitude of the hydration force, but that the averaged hydration pressure is independent of the radius of curvature. This latter conclusion suggests that there should be no penalty for the use of sharper tips if hydration force is the dominant interaction between the tip and the specimen, which might be realizable under certain conditions. Furthermore, the calculated hydration energy near the specimen surface compares well with experimentally determined values with an atomic force microscope, providing further support to the validity of these calculations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Ho, J Y Yuan, Z Shao. 1998. Hydration force in the atomic force microscope: A computational study.. https://doi.org/10.1016/s0006-3495(98)77597-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Full forward Monte Carlo calculation of portal dose from MLC collimated treatment beams.

This work deals with a full Monte Carlo (MC) simulation of a radiotherapy treatment facility including a multi-leaf collimator (MLC) and electronic portal imaging device (EPID). A method for a planar calibration of the EPID response in terms of dose using the MC technique is presented. Calibration measurements and simulations with several blocks of attenuating material are carried out down to approximatively 5% of the open field transmitted dose. A linear relationship is shown between the squared EPID signal and the MC calculated dose. The calibrated EPID was used as a dosimetric system to validate a MC model for the MLC. Computations and measurements agreed within 2% of dose difference (or 2 mm in regions of high dose gradient). The technique described herein is not significantly limited by physics transport model constraints. Therefore it can potentially provide a more accurate verification of dose delivery to inhomogeneous anatomical regions in patients undergoing complex multi-field conformal or intensity-modulated radiation therapy.

Calibration↗

Use of a Plackett-Burman design with multivariate calibration for the analysis of polycyclic aromatic hydrocarbons in micellar media by synchronous fluorescence.

This work describes the use of a multilevel Plackett-Burman design (PB) for the creation of a calibration set for partial least square regression (PLS). The PB calibration set was compared to a collinear analogue by testing these two PLS models for the analysis of six polycyclic aromatic hydrocarbons (PAHs). These compounds were analyzed in micellar media by synchronous fluorescence after determination of the experimental conditions (choice of surfactant, analytical conditions such as deltalambda, step, and scan range). The external validation shows that the collinear set is inappropriate to quantify PAH in real samples, but the PB calibration set affords optimal results.

Calibration↗

Determination of polarimetric parameters of honey by near-infrared transflectance spectroscopy.

NIR transflectance spectroscopy was used to determine polarimetric parameters (direct polarization, polarization after inversion, specific rotation in dry matter, and polarization due to nonmonosaccharides) and sucrose in honey. In total, 156 honey samples were collected during 1992 (45 samples), 1995 (56 samples), and 1996 (55 samples). Samples were analyzed by NIR spectroscopy and polarimetric methods. Calibration (118 samples) and validation (38 samples) sets were made up; honeys from the three years were included in both sets. Calibrations were performed by modified partial least-squares regression and scatter correction by standard normal variation and detrend methods. For direct polarization, polarization after inversion, specific rotation in dry matter, and polarization due to nonmonosaccharides, good statistics (bias, SEV, and R(2)) were obtained for the validation set, and no statistically (p = 0.05) significant differences were found between instrumental and polarimetric methods for these parameters. Statistical data for sucrose were not as good as those of the other parameters. Therefore, NIR spectroscopy is not an effective method for quantitative analysis of sucrose in these honey samples. However, NIR spectroscopy may be an acceptable method for semiquantitative evaluation of sucrose for honeys, such as those in our study, containing up to 3% of sucrose. Further work is necessary to validate the uncertainty at higher levels.

Calibration↗