Ultrasonic imaging using optoelectronic transmitters.

Abstract

Conventional ultrasound scanners utilize electronic transmitters and receivers at the scanner with a separate coaxial cable connected to each transducer element in the handle. The number of transducer elements determines the size and weight of the transducer cable assembly that connects the imaging array to the scanner. 2-D arrays that allow new imaging modalities to be introduced significantly increase the channel count making the transducer cable assembly more difficult to handle. Therefore, reducing the size and increasing the flexibility of the transducer cable assembly is a concern. Fiber optics can be used to transmit signals optically and has distinct advantages over standard coaxial cable to increase flexibility and decrease the weight of the transducer cable for larger channel numbers. The use of fiber optics to connect the array and the scanner entails the use of optoelectronics such as detectors and laser diodes to send and receive signals. In transmit, optoelectronics would have to be designed to produce high-voltage wide-bandwidth pulses across the transducer element. In this paper, we describe a 48 channel ultrasound system having 16 optoelectronic transmitters and 32 conventional electronic receivers. We investigated both silicon avalanche photodiodes (APD's) and GaAs lateral photoconductive semiconductor switches (PCSS's) for producing the transmit pulses. A Siemens SI-1200 scanner and a 2.25 MHz linear array were used to compare the optoelectronic system to a conventional electronic transmit system. Transmit signal results and images in tissue mimicking of cysts and tumors are provided for comparison.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C D Emery, H C Casey, S W Smith. 1998. Ultrasonic imaging using optoelectronic transmitters.. https://doi.org/10.1177/016173469802000203

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Plasmon resonances in gold-coated tilted fiber Bragg gratings.

The transmission spectrum of fiber Bragg gratings with gratings planes tilted at a small angle (2 degrees -10 degrees) relative to the fiber axis shows a large number of narrowband cladding mode resonances within a 100 nm wide spectrum. When a gold coating with a thickness between 10 and 30 nm is deposited on the fiber, the transmission spectrum shows anomalous features for values of the outside medium refractive index between 1.4211 and 1.4499. These features are shown to correspond to the excitation of surface plasmon resonances at the external surface of the gold film.

Fiber Optic Technology↗

Near-infrared spectroscopy (NIRS) reflectance technology for the determination of tocopherols in alfalfa.

The vitamin E (alpha- and (beta+gamma)-tocopherol) contents present in alfalfa (fresh or dehydrated) were analysed using near-infrared spectroscopy (NIRS) technology together with a remote reflectance fibre-optic probe. The range of vitamin E was 0.55-5.16 mg/100 g for alpha-tocopherol and 0.07-0.48 for (beta+gamma)-tocopherol. The regression method employed was modified partial least squares (MPLS). The equations developed using the fibre-optic probe for 69 samples of alfalfa (dehydrated and fresh) to determine the content of vitamin E in feeds had multiple correlation coefficients (RSQs) and prediction corrected standard errors (SEP (C)) of 0.946 and 0.321 mg/100 g for alpha-tocopherol and 0.956 and 0.022 mg/100 g for (beta+gamma)-tocopherol. The predicted values of vitamin E in feeds using NIRS technology applying the fibre-optic probe directly on the sample with neither previous treatment nor manipulation are comparable to those obtained using the chemical method, which included alkaline hydrolysis and hexane extraction of the vitamin from the unsaponifiable fraction before chromatographic determination.

Fiber Optic Technology↗

Use of (130)Te(2) for frequency referencing and active stabilisation of a violet extended cavity diode laser.

This paper reports on the use of (130)Te(2) absorption lines in active laser-locking, and in frequency referencing, of the emission of a violet extended cavity diode laser with a wavelength of around 410 nm. We note the existence of closely spaced tellurium absorption lines, suitable for referencing purposes in gas sensing applications, at wavelengths below the lower limit (417 nm) of the spectral region covered by the tellurium atlas [J. Cariou, P. Luc, Atlas du spectre d'Absorption de la Molecule de Tellure, CNRS, Paris, 1980]. The absolute positions of the lines in the acquired spectra were estimated by comparison to a simultaneously acquired fluorescence spectrum of atomic indium, and were identified using calculations based on fundamental spectroscopic data. The laser frequency was stabilised within a range of 40 MHz, which is negligible compared to typical transition widths at atmospheric pressure.

Fiber Optic Technology↗