Membrane-mediated sample loading for automated DNA sequencing.

Abstract

A new and improved sample loading method for DNA sequencing gels using oligo/polynucleotide binding membranes is described. The labeled DNA sequencing fragments were spotted onto a membrane sample loader, which was then placed in contact with the precast polyacrylamide separation gel. In this way, the time-consuming sample well loading by the tedious pipetting procedure was avoided. The spotted DNA fragments remain immobilized on the membrane until the separation process is initiated by the application of the electric field (an active DNA release mechanism). This novel technique enables sample loading outside of the separation platform, thereby allowing full utilization of various automated sample preparation and liquid handling (robotics) systems, resulting in "real" automated DNA sequencing. The loaded membranes can be stored for more than 24 hours for later use.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S M Cassel, A Guttman. 1998. Membrane-mediated sample loading for automated DNA sequencing.. https://doi.org/10.1002/elps.1150190823

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Semi-automated determination of plasma stability of drug discovery compounds using liquid chromatography-tandem mass spectrometry.

A simple procedure for the measurement of stability of drug candidates in plasma was developed to eliminate the traditional labor-intensive and time-consuming sample preparation procedures that are typically used for these studies. The procedure makes use of a thermostatic autosampler as an incubator combined with the direct plasma injection method based on high-performance liquid chromatography (HPLC) coupled to tandem mass spectrometry (MS-MS). Untreated human, monkey, mouse and rat plasma containing the test compound was directly injected into a mixed-function column for on-line protein removal and chromatography. The test compound and its biotransformation product were separated via HPLC and monitored using the tandem mass spectrometer. The need for adequate chromatographic separation of the test compound (M) from its carboxylic acid metabolite (M+1) is demonstrated. Plasma samples from four different species at specified incubation temperatures were sequentially assayed in one analytical procedure. The injection-to-injection time was about 6 min. The peak responses of the test compound in individual plasma samples were repeatedly determined every 24 min. The retention times and peak shape of all analytes were found to be consistent throughout the experiments. The stability of the test compound in plasma was found to be a function of animal species, incubation time and temperature. The test compound was rapidly degraded in rat plasma at 37 degrees C, but it could be stabilized by adding sodium thiosulfate.

Automation↗

Real-time monitoring of picomolar concentrations of iron(II) in marine waters using automated flow injection-chemiluminescence instrumentation.

A shipboard-deployable, flow-injection (FI) based instrument for monitoring iron(II) in surface marine waters is described. It incorporates a miniature, low-power photon-counting head for measuring the light emitted from the iron(II)-catalyzed chemiluminescence (CL) luminol reaction. System control, signal acquisition, and data processing are performed in a graphical programming environment. The limit of detection for iron(II) is in the range 8-12 pmol L(-1) (based on 3 s of the blank), and the precision over the range 8-1000 pmol L(-1) varies between 0.9 and 7.6% (n = 4). Results from a day-night deployment during a north-to-south transect of the Atlantic Ocean and a daytime transect in the Sub-Antarctic Front are presented together with ancillary temperature, salinity, and irradiance data. The generic nature of the components used to assemble the instrument make the technology readily transferable to other laboratories and the modular construction makes it easy to adapt the system for use with other CL chemistries.

Automation↗

PipeOnline 2.0: automated EST processing and functional data sorting.

Expressed sequence tags (ESTs) are generated and deposited in the public domain, as redundant, unannotated, single-pass reactions, with virtually no biological content. PipeOnline automatically analyses and transforms large collections of raw DNA-sequence data from chromatograms or FASTA files by calling the quality of bases, screening and removing vector sequences, assembling and rewriting consensus sequences of redundant input files into a unigene EST data set and finally through translation, amino acid sequence similarity searches, annotation of public databases and functional data. PipeOnline generates an annotated database, retaining the processed unigene sequence, clone/file history, alignments with similar sequences, and proposed functional classification, if available. Functional annotation is automatic and based on a novel method that relies on homology of amino acid sequence multiplicity within GenBank records. Records are examined through a function ordered browser or keyword queries with automated export of results. PipeOnline offers customization for individual projects (MyPipeOnline), automated updating and alert service. PipeOnline is available at http://stress-genomics.org.

Automation↗