PubMed Health⌕ Search

PubMed · 9698356

Retrieval dynamics in oscillator neural networks.

Abstract

We present an analytical approach that allows us to treat the long-time behavior of the recalling process in an oscillator neural network. It is well known that in coupled oscillatory neuronal systems, under suitable conditions, the original dynamics can be reduced to a simpler phase dynamics. In this description, the phases of the oscillators can be regarded as the timings of the neuronal spikes. To attempt an analytical treatment of the recalling dynamics of such a system, we study a simplified model in which we discretize time and assume a synchronous updating rule. The theoretical results show that the retrieval dynamics is described by recursion equations for some macroscopic parameters, such as an overlap with the retrieval pattern. We then treat the noise components in the local field, which arise from the learning of the unretrieved patterns, as gaussian variables. However, we take account of the temporal correlation between these noise components at different times. In particular, we find that this correlation is essential for correctly predicting the behavior of the retrieval process in the case of autoassociative memory. From the derived equations, the maximal storage capacity and the basin of attraction are calculated and graphically displayed. We also consider the more general case that the network retrieves an ordered sequence of phase patterns. In both cases, the basin of attraction remains sufficiently wide to recall the memorized pattern from a noisy one, even near saturation. The validity of these theoretical results is supported by numerical simulations. We believe that this model serves as a convenient starting point for the theoretical study of retrieval dynamics in general oscillatory systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Aoyagi, K Kitano. 1998-08-15. Retrieval dynamics in oscillator neural networks.. https://doi.org/10.1162/089976698300017296

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗