PubMed · 9702702
Amplitude response and stimulus presentation frequency response of human primary visual cortex using BOLD EPI at 4 T.
Abstract
Detailed measurement of the neural response to flicker frequency using functional MRI (fMRI) were made. The fMRI signal peaks at a flicker frequency of 8 Hz in human V1, in agreement with previous positron emission tomography (PET) and fMRI experiments. The modulation amplitude of the hemodynamic response to varying continuous periods of flicker stimulation was measured. The hemodynamic response was not observed to be modulated by neural modulation for periods shorter than 6.7 s. The resemblance between the BOLD response to the stimulus presentation frequency and the base-line power spectra at the same frequencies suggests that the same underlying mechanism could be responsible for both curves and that the base-line fMRI power spectrum is probably due to base-line electrical activity in the brain. The integrals of the resting base-line power spectrum, the background power spectrum, the respiration component, and the cardiac component were found to be linearly dependent on TE.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
C G Thomas, R S Menon. 1998. Amplitude response and stimulus presentation frequency response of human primary visual cortex using BOLD EPI at 4 T.. https://doi.org/10.1002/mrm.1910400206. https://pubmed.health/record/pubmed%3A9702702/amplitude-response-and-stimulus-presentation-frequency-response-of-human-primary-visual-cortex-using