PubMed Health⌕ Search

PubMed · 9727339

Dynamic knee loads during gait predict proximal tibial bone distribution.

Abstract

This study tested the validity of the prediction of dynamic knee loads based on gait measurements. The relationship between the predicted loads at the knee and the distribution of bone between the medial and lateral sides of the tibia was examined. The motion and external forces and moments at the knee were measured during gait and a statically determinate muscle model was used to predict the corresponding forces on the medial and lateral tibial plateaus. In particular, the relationship between the knee adduction moment during gait and the ratio or distribution of medial to lateral tibial bone mineral content was studied. Bone mineral content was measured with dual energy X-ray absorptiometry in four regions, two proximal regions 20 mm in height, one medial and one lateral and two distal regions 20 mm in height, one medial and one lateral. The best single predictor of the medial lateral ratio of proximal bone mineral content (bone distribution) was the adduction moment (R2=0.31, p=0.003). Adding weight (negative coefficient. p=0.0004) and the ratio of the average predicted peak force on the medial plateau to the predicted peak force on the lateral plateau (positive coefficient, p=0.0033) to the regression model significantly increased the ability to predict the proximal medial lateral bone distribution (R2=0.72, p=0.0001). Distally neither the subject characteristics nor the gait moments and predicted forces were significant predictors of the bone distribution. The lack of a correlation distally may be reflective of the forces being more evenly distributed further from the tibial plateau. While it has long been suggested that the adduction moment is the primary determinate of the distribution of load between the medial and lateral plateaus, this is the first evidence of its relationship to the underlying bone distribution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D E Hurwitz, D R Sumner, T P Andriacchi, D A Sugar. 1998. Dynamic knee loads during gait predict proximal tibial bone distribution.. https://doi.org/10.1016/s0021-9290(98)00028-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗