PubMed Health⌕ Search

PubMed · 9731694

Maximal and submaximal exercise testing in heart failure.

Abstract

Although reduced exercise capacity is the main complaint of patients with congestive heart failure (CHF), the best method to measure it remains controversial. Peak VO2, obtained using maximal exercise testing, is the most accurate measure of maximal functional capacity. It is related to peak exercise cardiac output and is one of the most important independent variables for the prognostic assessment of patients with CHF. It has, however, a low sensitivity for measurement of changes induced by therapy and is poorly related to everyday physical activity, patient symptoms, and quality of life. The anerobic threshold may also be regarded as a parameter of maximal functional capacity. Its value is mainly indirect, because it shows that the patient is performing a maximal effort limited by the cardiovascular system. The VO2 kinetics at the start and at the end of exercise are probably more related to patient symptoms, but it is unresolved which protocols and parameters might best be used to study this aspect of exercise performance. Duration of a submaximal exercise at a constant work rate and the distance walked during a 6-min walking test are gaining wide popularity as parameters of submaximal performance. However, when these exams are carried out up to exhaustion in patients with severe functional limitation, they may involve attainment of the anerobic threshold and therefore their clinical meaning may be similar to the one of a maximal exercise test. Moreover, tests based on the assessment of submaximal exercise capacity have been useful for assessment of therapy in single-center trials but have been often inadequate in multicenter trials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Metra, S Nodari, D Raccagni, M Garbellini, E Boldi, L Bontempi, M Gaiti, L Dei Cas. 1998. Maximal and submaximal exercise testing in heart failure.. https://doi.org/10.1097/00005344-199800003-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Physiological mechanisms dissociating pulmonary CO2 and O2 exchange dynamics during exercise in humans.

During moderate exercise (below the lactate threshold, (thetaL)), muscle CO(2) production ( Q(CO2)) kinetics are monoexponential, with a time constant (tau) similar to that of O(2) consumption. Following a delay incorporating the muscle-lung vascular transit time, Q(CO2) is expressed at the lungs (V(CO2)) with an appreciably longer tau, reflecting the influence of intervening high-capacitance CO(2) stores. Above (thetaL), kinetics become complex, resulting from the conflation of the differing rates of HCO(3)(-) breakdown and degrees of compensatory hyperventilation with that of the underlying aerobic component. During incremental exercise, the increased rate of relative to pulmonary O(2) uptake (V(CO2)) can be used to quantify (thetaL) validly if aerobic and hyperventilatory sources can be ruled out, i.e. (thetaL) is then attributable to the decrease in muscle and blood [HCO(3)(-)]. In many cases, however, very rapid incrementation of work rate and/or prior depletion of CO(2) stores (by volitional or anticipatory hyperventilation) can yield a 'false positive' non-invasive estimation of (thetaL) ('pseudo-threshold') resulting from a slowing of the rate of wash-in of transient CO(2) stores.

Anaerobic Threshold↗

Critical velocity during continuous and intermittent exercises in children.

The purpose of this study was to apply the "critical velocity" concept to short intermittent high-intensity running exercises in prepubescent girls and boys and to compare the running performances obtained either by intermittent or continuous exercise runs. Eleven 8 to 11-year-old children underwent a maximal graded field test to determine peak oxygen uptake (peakVO2) and maximal aerobic velocity (MAV). During the six following sessions, they randomly performed three continuous runs (90, 100, and 110% of MAV) and three intermittent runs (120, 130, and 140% of MAV) until exhaustion. Intermittent exercises consisted of repeated 15 s runs each one separated by a 15 s passive recovery interval. For continuous as well as intermittent exercises, distance versus time to exhaustion (TTE) relationships were calculated to determine continuous (CVc) and intermittent (CVi) critical velocities. Values for peakVO2 and MAV were 45.8 +/- 5.3 ml x kg(-1) x min(-1) and 10.5 +/- 1.0 km h(-1), respectively. For the whole population, a significant relationship was found between the distance to exhaustion (DTE) and TTE for continuous (r2= 0.99, P < 0.05) and intermittent exercises (r2 = 0.99, P < 0.05). Significant relationships were found between peakVO2 and both CVc (r2= 0.60, P < 0.01) and CVi (r2= 0.47, P < 0.05). In conclusion, as for continuous exercises, a linear relationship was found between DTE and TTE for short high-intensity intermittent exercises. CVc was significantly related to peakVO2, while a significant lower relationship was found between peakVO2 and CVi.

Anaerobic Threshold↗

Pulmonary function at peak exercise in patients with chronic heart failure.

BACKGROUND: Various respiratory abnormalities are associated with chronic heart failure (CHF). However, changes in inspiratory capacity (IC) and breathing pattern from rest to exercise in patients with CHF have not been thoroughly investigated in these patients. MATERIALS AND METHODS: Seventy seven (66 male/11 female) patients with clinical stable CHF (age: 52+/-11 years) were studied. All the patients underwent pulmonary function tests, including measurements of IC and maximal inspiratory pressure (Pimax) at rest and then a maximal cardiopulmonary exercise testing (CPET) on a treadmill. During the CPET, IC was measured every 2 min. Pimax was measured again after the end of CPET. RESULTS: Percent predicted forced expiratory volume in 1 s (FEV1) was 91+/-12, %predicted forced vital capacity (FVC) was 92+/-13, %FEV1/FVC was 81+/-4, and %predicted IC was 85+/-18. Peak exercise IC was lower than resting (2.4+/-0.6 vs. 2.6+/-0.6 l, p<0.001). Analysis of variance between Weber's groups revealed statistically significant differences in peak exercise IC (p<0.001), VE/VCO2slope (p<0.001), resting Pimax (p=0.005) and post-exercise Pimax (p<0.001). At rest, there was a statistically significant difference in end-tidal CO2 (P(ETCO2)) (p=0.002), in breathing frequency (p=0.004), in inspiratory time (Ti) (p=0.04) and in total respiratory time (T(Tot)) (p=0.004) among Weber's groups. At peak exercise there was a statistically significant decrease in minute ventilation (VE) (p<0.001), tidal volume (VT) (p<0.001), respiratory cycle (VT/TI) (p<0.001) and P(ETCO2) (p<0.001). Peak IC was correlated with peak VO2 (r=0.72, p<0.001), anaerobic threshold (r=0.71, p<0.001), VO2/t slope (r=0.54, p<0.0001), and post-exercise Pimax (r=0.62, p<0.001). CONCLUSIONS: In patients with CHF, peak exercise IC is reduced in parallel with disease severity, which is probably due to respiratory muscle dysfunction.

Anaerobic Threshold↗