Multicentre evaluation of KONE Optima analysis system.

Abstract

Optima from KONE Instruments Corporation is a new selective laboratory analyzer for turbidimetric, colorimetric and ion selective electrode measurements. Overall analytical performance of Optima and reagents provided by KONE was evaluated according to ECCLS guidelines, in a multicentre study involving four different laboratories, including substrates (cholesterol, high-density lipoprotein-cholesterol, creatinine), specific proteins (transferrin, IgG), enzyme activities (gamma-glutamyltransferase, alanine aminotransferase) and electrolytes (sodium, potassium, chloride). The results obtained attest good precision of the system for all the analytes tested: the range of within-run CV is 0.5 %-4.3 %, and range of between-day CV % is 0.8 %-7.9 % (median of four laboratories). Except for total cholesterol (5 % overestimation compared to the reference method) accuracy of measurement is adequate. Creatinine and uric acid assays were subjects of interference (defined as deviation > 10 % from target value) by bilirubin and haemoglobin respectively.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Ferrero, A Modenese, P A Bonini, F Ceriotti, A Carobene, M Franzin, W G Guder, W Hofmann, M Puukka, H Laitinen, V Makarovsky, N Gaidukova. 1998. Multicentre evaluation of KONE Optima analysis system.. https://doi.org/10.1515/cclm.1998.080

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection of Delta9-tetrahydrocannabinolic acid A in human urine and blood serum by LC-MS/MS.

Delta9-tetrahydrocannabinolic acid A (Delta9-THCA-A) is the precursor of Delta9-tetrahydrocannabinol (Delta9-THC) in hemp plants. During smoking, the non-psychoactive Delta9-THCA-A is converted to Delta9-THC, the main psychoactive component of marihuana and hashish. Although the decarboxylation of Delta9-THCA-A to Delta9-THC was assumed to be complete--which means that no Delta9-THCA-A should be detectable in urine and blood serum of cannabis consumers--we found Delta9-THCA-A in the urine and blood serum samples collected from police controls of drivers suspected for driving under the influence of drugs (DUID). For LC-MS/MS analysis, urine and blood serum samples were prepared by solid-phase extraction. Analysis was performed with a phenylhexyl column using gradient elution with acetonitrile. For detection of Delta9-THCA-A, the mass spectrometer (MS) (SCIEX API 365 triple-quadrupole MS with TurboIonSpray source) was operated in the multiple reaction monitoring (MRM) mode using the following transitions: m/z357 --> 313, m/z357 --> 245 and m/z357 --> 191. Delta9-THCA-A could be detected in the urine and blood serum samples of several cannabis consumers in concentrations of up to 10.8 ng/ml in urine and 14.8 ng/ml in serum. The concentration of Delta9-THCA-A was below the Delta9-THC concentration in most serum samples, resulting in molar ratios of Delta9-THCA-A/Delta9-THC of approximately 5.0-18.6%. Only in one case, where a short elapsed time between the last intake and blood sampling is assumed, the molar ratio was 18.6% in the serum. This indicates differences in elimination kinetics, which need to be investigated in detail.

Blood Chemical Analysis↗