PubMed HealthSearch

PubMed · 9749908

A static dynamometer measuring simultaneous torques exerted at the upper limb.

Abstract

The majority of available dynamometers are designed to measure force or torque in one specific direction, one joint at a time. For the quantification of motor incoordination in neurological patient populations, these dynamometers provide limited information about the global behavior of the limb under investigation. This report describes the potential use and function of a static dynamometer measuring torques exerted simultaneously at the shoulder (flexion-extension, abduction-adduction, internal-external rotation), elbow (flexion-extension), and forearm (pronation-supination). Orthogonal forces were measured at the arm and wrist using strain gauge transducers interfaced with a laboratory computer. The lever arms were specified to a software program and the joint torques were calculated in real time according to static equilibrium equations. The use of the dynamometer is illustrated by characterizing for one hemiparetic subject, the joints torques recorded at the shoulder, elbow, and forearm during isolated submaximal grip exertions at different force levels on both sides. The torques generated at the shoulder, elbow and forearm during the hand grip tasks on the affected side were significantly higher than those obtained on the nonaffected side and increased with the grip force level. These differences probably reflect the loss of movement selectivity observed following a lesion in the central nervous system. Further studies are currently being undertaken in neurological patient populations to characterize and quantify motor deficits using this dynamometer. As a long term goal, we hope that the method and technologies described here will contribute to the evaluation and rehabilitation of these populations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Boissy, D Bourbonnais, D Gravel, A B Arsenault, M Leblanc. 1998. A static dynamometer measuring simultaneous torques exerted at the upper limb.. https://doi.org/10.1109/86.712229

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Visual feedback to stabilize head position for fMRI.

Head motion is a common cause of technical failure in functional magnetic resonance imaging. A simple visual alignment system has been developed to provide visual feedback to the subject about his or her head position. The subject is able to readjust his or her head position accurately during a study, should motion occur. This sighting system is incorporated into a visor that fits onto the commercial head coil. The accuracy of correcting head motion and activation maps obtained with this device are demonstrated. The cognitive workload of using the alignment system does not significantly alter the activation pattern associated with eye movement paradigms.

Biofeedback, Psychology

Treatment of female urinary incontinence with EMG-controlled biofeedback home training.

The aim of the study was to evaluate the efficacy of pelvic floor training with EMG-controlled home biofeedback in the treatment of stress and mixed incontinence in women. Subjects were recruited from the urodynamic outpatient clinic and performed pelvic muscle training with an EMG-controlled biofeedback device for 20 minutes daily for 6 months. The number of pads used per day, the number of incontinence and urgency episodes, voiding frequency, maximum urethral closure pressure, functional urethral length and pressure/transmission ratio during stress were assessed before and after treatment. Thirty-three patients (13 with stress and 20 with mixed incontinence) completed the study. There was a significant decrease in the number of pads used per day, the number of incontinence and urgency episodes, and the voiding frequency. Twenty-eight patients (85%) reported that they were cured or improved. Urodynamic parameters did not change significantly. It was concluded that home pelvic floor training with EMG-controlled biofeedback is efficient in 85% of patients in alleviating the symptoms of genuine stress and mixed incontinence without causing side effects.

Biofeedback, Psychology