PubMed Health⌕ Search

PubMed · 9751021

Isotachophoretic separations on a microchip. Normal Raman spectroscopy detection.

Abstract

Isotachophoretic separations of the herbicides paraquat and diquat are performed in a glass microchip etched channel and monitored on-chip by normal Raman spectroscopy. The 40-micron-wide and 75-micron-deep separation channels are chemically etched in a serpentine design to 21-cm total length. A 120-micron-thick glass cover slip is used to seal the channels. Separation field strengths up to 380 V/cm are used. The microchip is directly coupled to a Raman microprobe. No interfacing is required. Raman spectra are generated with a 2-W, 532-nm NdY-VO4 laser and collected at 8-cm-1 resolution with a holographic transmissive spectrograph and a cryogenically cooled CCD. Data acquisition is at 2-5 spectra/s. Raman isotachopherograms of the pesticides at starting concentrations as low as 2.3 x 10(-7) M (60 ppb paraquat/80 ppb diquat) are presented.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P A Walker, M D Morris, M A Burns, B N Johnson. 1998-09-15. Isotachophoretic separations on a microchip. Normal Raman spectroscopy detection.. https://doi.org/10.1021/ac980195h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Spectra interference between diquat and paraquat by second derivative spectrophotometry.

A rapid and accurate method, combining solid-phase extraction and second-order derivative spectrophotomety approaches, is developed for the simultaneous determination of diquat (DQ) and paraquat (PQ) in blood, tissue and urine samples. Supernatant resulting from the precipitation of protein (with trichloroacetic acid) in plasma and tissue or Amberlite IRA-401 resin treated urine are passed through a mini-column packed with Wakogel gel (Silica gel). Analytes are then eluted with a non-organic solvent, 0.2mol/l HCl solution containing 2mol/l NH(4)Cl. UV spectrum of the eluent in 220-350nm range provides effective screen to detect the presence of DQ and/or PQ. In the presence of DQ or PQ alone, the analyte present is quantitated by conventional zero- or second-order derivative spectrophotometry. The calibration curve in the 0.1-5.0mg/l range for either analyte obeys Beer's law. When both DQ and PQ are present, their concentrations are determined by the peak amplitudes of their respective second-derivative spectra after the addition of alkaline dithionite reagent. Interference is negligible when the DQ/PQ concentration ratio is within the 5.0-0.2 range. Using a 2-ml of sample size, the detection limits for DQ and PQ in plasma are 0.02 and 0.005mg/l. The corresponding detection limits for urine samples (10ml sample size) are 0.004 and 0.001mg/l. Recoveries of DQ and PQ in triplicate plasma and urine samples spiked with 0.5mg/l of analytes are 93 and 85%. The precision of the proposed method resulting from triplicate study of spiked urine samples varies from 3.2 to 4.6% at 0.5mg/l of DQ and PQ, respectively.

Diquat↗

Sample stacking with matrix removal for the determination of paraquat, diquat and difenzoquat in water by capillary electrophoresis.

Conditions for the simultaneous determination of paraquat, diquat and difenzoquat by capillary zone electrophoresis using a stacking technique in a chemically modified capillary have been established. To apply the stacking method with sample matrix removal for the analysis of cations, an anodic electroosmotic flow is mandatory. For quats, 50 mM acetic acid-ammonium acetate (pH 4.0) with 5% (v/v) methanol as electrophoretic buffer and the addition of 0.8 mM cetyltrimethylammonium bromide as wall capillary organic modifier was proposed. Field polarity reversal time was optimised for several sample matrices. Detection was carried out at 220 and 255 nm. Detection limits, based on a signal-to-noise ratio of 3:1, were lower than 15 microg l(-1) for standards in Milli-Q water and two to ten times higher for drinking water samples. Run-to-run and day-to-day reproducibility have been established. The method was successfully applied to the determination of the three herbicides in spiked drinking water.

Diquat↗

Sensitive determination of diquat by a kinetic method using the stopped-flow mixing technique.

A simple, sensitive, selective, fast and inexpensive assay for the determination of diquat is proposed. The method is based on the reduction of the herbicide to a strongly fluorescent monocation radical with sodium dithionite. The initial rate of this reaction is directly proportional to the diquat concentration. The stopped-flow mixing technique was used because the kinetic data can be obtained in only 7 s, meaning that the method can be automated. The calibration graph is linear over the range 5-500 ng ml-1 and the precision (RSD) is close to 1.2%. The applicability of the method was demonstrated by determining the herbicide in different kinds of samples.

Diquat↗