PubMed Health⌕ Search

PubMed · 9773891

A flow cytometer designed for fluorescence calibration.

Abstract

In the development of suitable standards and calibration materials for fluorescence measurement, it becomes necessary to make accurate fluorescence measurements of these materials on flow cytometers. The results of such measurements may be affected by numerous sources of error, prominent among which are deviations of logarithmic amplifiers (log amps) from ideal response. To minimize the deleterious effects of log amps and multicolor fluorescence compensation circuitry on measurements, we built a flow cytometer with electronics incorporating high-precision peak detectors usable over a range from below 2 mV to 10 V, and we developed data acquisition software that transfers held peak values to a commercial 16-bit data acquisition system mounted in a personal computer running Windows 95. Fluorescence compensation is done in software, and transformation of the compensated data from a 16-bit linear to an 8-bit, 4-decade logarithmic scale is accomplished using a look-up table. Although dynamic range may be restricted by noise in the data acquisition system, high sensitivity can be achieved by photomultiplier tube gain adjustment, and it is likely that the use of a lower noise data acquisition system and/or digital processing of pulse information will enable operation over the full 4-decade dynamic range. Even at its current performance level, our instrument provides substantially better linearity over most of the scale than can be obtained using conventional electronics incorporating log amps; we believe this characteristic is critical for use in standards development.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H M Shapiro, N G Perlmutter, P G Stein. 1998-10-01. A flow cytometer designed for fluorescence calibration.. https://doi.org/10.1002/(sici)1097-0320(19981001)33%3A2%3C280%3A%3Aaid-cyto25%3E3.0.co%3B2-p

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A user-friendly PC-based data acquisition and analysis system for respirometric investigations.

We have developed an easy-to-use computer-based system for recording, displaying, storing and analyzing signals generated by Clark-type oxygen electrodes. A user-friendly interface of Windows-based program BioMed significantly increases the productivity of investigations. It allows to process, control, present and archive the experimental data in real time. A 12-bit analog-to-digital-converter, analog and digital filters, a possibility to zoom the obtained respiratory curves and calculation of the respiration rates by a linear regression method increase the resolution of the estimated oxygen consumption rates. The new system enables to register even small changes, such as 3-5 ngatoms O/min, in respiration rates of biological objects -- enzymes, mitochondria and permeabilized muscle fibers. The system has been developed and is regularly used for the respirometric investigations at the Laboratory of Biochemistry, Institute for Biomedical Research, Kaunas University of Medicine.

Analog-Digital Conversion↗

Elimination of depth degeneracy in optical frequency-domain imaging through polarization-based optical demodulation.

A novel optical frequency-domain imaging system is demonstrated that employs a passive optical demodulation circuit and a chirped digital acquisition clock derived from a voltage-controlled oscillator. The demodulation circuit allows the separation of signals from positive and negative depths to better than 50 dB, thereby eliminating depth degeneracy and doubling the imaging depth range. Our system design is compatible with dual-balanced and polarization-diverse detection, important techniques in the practical biomedical application of optical frequency-domain imaging.

Analog-Digital Conversion↗