PubMed HealthSearch

PubMed · 9785821

Patient-ventilator interactions.

Abstract

The focus of this chapter has been the information contained in airway pressure, volume, and flow traces from mechanically-ventilated patients. It has not been our intention to make ventilator management recommendations. Practitioners willing to make the effort to interpret patient-ventilator interactions will find it difficult to manage ventilator-dependent patients without feedback from waveform analysis in the future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R W Stroetz, R D Hubmayr. 1998. Patient-ventilator interactions.. https://pubmed.ncbi.nlm.nih.gov/9785821/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

House dust mite-induced airway changes in hu-SCID mice.

SCID (severe combined immunodeficiency) mice reconstituted with peripheral blood mononuclear cells (PBMC) from Dermatophagoides pteronissynus (Dpt)-sensitive patients and exposed to Dpt aerosol (allergic hu-SCID mice) develop human IgE and pulmonary inflammation. The present study investigated concomitant changes in airway hyperresponsiveness (AHR). No significant difference in baseline airway responsiveness was seen between nonreconstituted SCID mice exposed or not to Dpt aerosol at Day 35. Allergic hu-SCID mice developed AHR (provocative dose of carbachol causing a 50% increase in lung resistance [PD(50) RL] = 96.33 +/- 16.88 microg/kg) compared with nonallergic hu-SCID mice (PD(50) RL = 242.03 +/- 37.84 microg/kg) and nonreconstituted SCID mice (PD(50) RL = 297.60 +/- 45. 60 microg/kg) exposed to Dpt aerosol. An inverse correlation was observed between PD(50) RL (Day 35) and total human IgE at Day 7 (r = -0.58) and Day 15 (r = -0.64). However, no correlation existed between PD(50) RL and human cell number in the lungs of allergic hu-SCID mice. Moreover, despite the absence of eosinophils, the bronchoalveolar lavage fluid (BALF) of allergic hu-SCID mice had more human interleukin-5 (IL-5) (3.28 +/- 0.40 pg/ml, n = 13) than nonallergic hu-SCID mice (< 0.5 pg/ml) which inversely correlated with the PD(50) RL (r = -0.61). No tumor necrosis factor-alpha (TNF-alpha), IL-6, or IL-4 was detected. These observations indicate that humanized allergic hu-SCID mice may develop AHR after exposure to the relevant allergen, suggesting that this model may improve our understanding of AHR, one characteristic feature of allergic asthma.

Airway Resistance

Effect of Pseudomonas infection on weight loss, lung mechanics, and cytokines in mice.

Poor growth, Pseudomonas aeruginosa endobronchitis, pulmonary inflammation, and decline of lung function are hallmarks of cystic fibrosis (CF), yet the relationship between these features is poorly understood. Because animal models of chronic bronchopulmonary infection with P. aeruginosa used to study pulmonary inflammation in CF have also been associated with weight loss, we sought to determine whether this weight loss was due to the inflammatory process and/or to changes in lung function. P. aeruginosa-laden agarose beads were instilled into the lungs of mice. Weight loss was greatest 3 d after Pseudomonas infection. Infected mice had a rapid though transient rise in absolute neutrophil counts, mTNF-alpha, mIL-1beta, mIL-6, mip-2, and KC in bronchoalveolar lavage fluid. There was no difference in lung resistance or lung compliance measured by body plethysmography between infected and control mice. Weight loss did correlate with the concentration of proinflammatory cytokine levels 3 d after inoculation of mice with Pseudomonas, and body composition analysis revealed loss of skeletal muscle mass. These results suggest that weight loss in P. aeruginosa-infected mice was associated with the inflammatory process and not with altered pulmonary responsiveness. These findings may provide insights into the cause of cachexia and weight loss seen in patients with CF.

Airway Resistance

An analysis algorithm for measuring airway lumen and wall areas from high-resolution computed tomographic data.

High-resolution computed tomography (HRCT) has been used to examine airway narrowing. We developed an automated computed tomographic image analysis algorithm (computed tomographic airway morphometry; CTAM) to measure airway lumen area (Ai ), airway wall area (Awa), and airway angle of orientation. Tubes of varying size were embedded in Styrofoam and then scanned at angles between 0 degrees and 50 degrees to assess the accuracy of measurements made with CTAM. Two excised pig lungs were fixed in inflation, sectioned, and scanned. Ai and Awa were measured planimetrically from the cut surfaces to optimize CTAM measurement parameters. In CTAM, Ai was defined according to an airway-size-dependent threshold value, and total Awa was determined through a score-guided erosion method. Results were compared with measurements made through a previously validated method (manual method). CTAM provided accurate measurements of the tubes' Ai values at all angles; Awa was overestimated in direct relation to airway size. The manual method underestimated Ai and overestimated Awa in a manner directly related to airway size as well as to airway angle of orientation. In the excised lung, the mean errors of Ai and Awa measurements made with CTAM were 0.52 +/- 0.24 mm(2) and 0.17 +/- 0.32 mm(2) (mean +/- SEM), respectively. Ai errors with the manual method were similar, but Awa was overestimated to a greater degree (6.3 +/- 0.38 mm(2); p < 0.01) and the error was proportional to Awa (r = 0.64; p < 0.01). CTAM allows accurate measurements of airway dimensions and angle of orientation.

Airway Resistance