Phase analysis in high-frequency oscillation.

Abstract

UNLABELLED: In an oscillating system driven by a sine wave pump, the resonance frequency of the respiratory system can be determined using phase analysis. At resonance frequency, when elastance and inertance cancel out, flow becomes in-phase with resistance. In premature infants with respiratory distress syndrome, owing to surfactant deficiency, localized areas of hyperinflation and collapse develop, resulting in complex changes in overall pulmonary mechanics. We investigated the effect of measuring resonance frequency of the respiratory system by phase analysis at different points of the respiratory cycle: end of inspiration, end of expiration, mid-inspiration and mid-expiration. Ten ventilated premature infants with respiratory distress syndrome were studied, gestational age ranged from 24 to 30 weeks (mean 27.6 weeks) and birth weight ranged from 0.7 to 1.505 kg (mean 0.984 kg). RESULTS: The resonance frequency was consistently higher when measured at the end of inspiration compared with the end of expiration. The expected trend of phase variation, that is, negative below the resonance frequency and positive above, was most consistently found when analysis was done at the end of inspiration. CONCLUSIONS: These findings were most likely a result of the complexity of pulmonary mechanics in the surfactant-deficient lungs, rendering the single compartment model we based our theory on inadequate. However, phase analysis performed at the end of inspiration seemed to produce the most reliable and consistent results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Lee, R Blowes, A D Milner. 1998. Phase analysis in high-frequency oscillation.. https://doi.org/10.1016/s1350-4533(98)00042-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗