Monte Carlo generated mammograms: development and validation.

Abstract

We have developed a model using Monte Carlo methods to simulate x-ray mammography. All possible physical processes of interaction of x-rays with matter have been taken into account. A simplified geometry of the mammographic apparatus has been considered along with a software phantom of compressed breast. The phantom may contain inhomogeneities of various compositions and sizes. We have used this model to produce Monte Carlo mammograms under realistic conditions. The validation of the simulation includes both the modelling of physical processes and the production of Monte Carlo mammograms. The first part is accomplished by the demonstration of the coincidence between Monte Carlo and theoretical data, whereas the second is accomplished by the comparison of real mammograms, taken from irradiation of a simplified breast phantom that we have constructed, and Monte Carlo mammograms taken from simulation of the above phantom under the corresponding exposure conditions. The limitations of the model as well as the future use of Monte Carlo mammograms are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Spyrou, G Tzanakos, A Bakas, G Panayiotakis. 1998. Monte Carlo generated mammograms: development and validation.. https://doi.org/10.1088/0031-9155%2F43%2F11%2F012

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Trigger finger release with hand surface landmark ratios: an anatomic and clinical study.

The purpose of this study was to identify surface landmark ratios to locate the A1 pulley and clarify the controversy of differing anatomic descriptions of the A1, C0, and A2 pulleys. Minimally invasive and percutaneous approaches to A1 pulley release may be facilitated with surface landmark ratios, which identify and predict the proximal and distal margins of the A1 pulley. Two-hundred fifty-sixty fingers were dissected in 64 preserved cadaver hands. Measurements of A1 pulley lengths and pulley margins in relation to surface landmarks were obtained. We found that the distance from the palmar digital crease to the proximal interphalangeal crease (mean, 2.42 +/- 0.03 cm) corresponds to the distance of the proximal edge of the A1 pulley from the palmar digital crease (mean, 2.45 +/- 0.03 cm). The mean absolute difference between these two measured distances in each finger was 0.13 cm, with a 95 percent confidence interval of 0.11 to 0.14 cm. Thus, the distance between the palmar digital crease and the proximal interphalangeal crease can be used to predict the distance between the palmar digital crease and the A1 pulley proximal edge with reasonable accuracy. A1 pulley length averaged 0.98 +/- 0.02 cm for the small finger and 1.17 +/- 0.02 cm for the index, middle, and ring fingers. The length of the A1 pulley was significantly shorter (p < 0.001) for the small finger than for the index, middle, and ring fingers. Additionally, a cruciate (C0) pulley was consistently located between the A1 and A2 pulleys, an average of 0.46 cm proximal to the palmar digital crease, which can serve as guide for concluding the release of the A1 pulley. Clinically, hand surface landmark ratios were used to release 32 trigger fingers with a minimally invasive technique, without a complication during 4- to 30-week follow-up. We conclude that hand surface landmark ratios can serve to locate the proximal A1 pulley edge, thus facilitating complete trigger finger release by either open or minimally invasive techniques. Additionally, our study clarifies the discrepancy of prior smaller reports of the pulley system anatomy regarding the existence of the C0 pulley between the A1 and A2 pulleys. The cruciate fibers of this C0 pulley can serve as the distal boundary for release of trigger finger.

Biophysical Phenomena↗

Colloidal interactions in suspensions of rods.

We report direct measurements of entropic interactions of colloidal spheres in suspensions of rodlike fd bacteriophage. We investigate the influence of sphere size, rod concentration, and ionic strength on these interactions. Although the results compare favorably with a recent calculation, small discrepancies reveal entropic effects due to rod flexibility. At high salt concentrations, the potential turns repulsive as a result of viral adsorption on the spheres and viral bridging between the spheres.

Biophysical Phenomena↗

Ribbon phase in a phase-separated lyotropic lamellar-sponge mixture under shear flow.

We report the effect of shear flow on a phase-separated system composed of lyotropic lamellar (L(alpha)) and sponge (L3) phases in a mixture of brine, surfactant, and cosurfactant. Optical microscopy, small-angle light, and x-ray scattering measurements are consistent with the existence of a steady state made of multilamellar ribbon-like structures aligned in the flow direction. At high shear rates, these ribbon-like structures become unstable and break up into monodisperse droplets resulting in a shear-thickening transition.

Biophysical Phenomena↗