PubMed Health⌕ Search

PubMed · 9836398

[Platelet alloantigenic systems].

Abstract

Platelet-specific alloantigen systems are located on glycoproteins expressed at the surface of platelet membrane. These di-allelic systems are due to an amino acid substitution. An official nomenclature was adopted in 1990 by the Working Party on Platelet Serology ICST/ISBT which defined the following rules: (1) platelet-specific antigen systems are called HPA for "Human Platelet Antigens"; (2) they are numbered chronologically according to the date of publication; (3) the most frequent allele is designated by the letter a and the less frequent by the letter b (i.e., HPA-1a 1b). Since the introduction of molecular biology techniques, the nomenclature has become insufficiently precise and an adjustment will probably be required in a near future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Hallé. 1998. [Platelet alloantigenic systems].. https://doi.org/10.1016/s1246-7820(98)85008-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Flow cytometry of platelets for clinical analysis.

Platelets are small, non-homogenous cells with distinctive surface features important to their essential role in hemostasis. The surface membrane is dynamic, and changes remarkably in lipid asymmetry and receptor expression on triggering of the activation process. There are also extensive and rapid intracellular changes in platelets as a result of biochemical activation through calcium fluxes, phospholipase activity, kinase activity, and phosphorylation mechanisms that lead to release of storage granule contents and generation of fast-acting prostaglandins, all in a matter of seconds after stimulation with a strong agonist. These characteristics make the platelet an interesting but difficult cell to study, and the explosion of knowledge over the last two decades has been fueled in large part by the application of flow cytometry techniques. Clinical applications of flow cytometry analysis of platelets have been pursued in individual specialized medical centers, but have not found widespread practice in clinical laboratories, mostly because of difficulties in standardization of techniques and the inherent biovariability in comparing normal to abnormal platelets. Despite these hurdles, it seems certain that flow cytometry analysis of platelets in pathological states will continue to evolve into more practical and robust procedures that will eventually become standard hematologic assays rather than specialized research tools.

Antigens, Human Platelet↗

Genotyping of human platelet antigen-1 by gene amplification and labelling in one system and automated fluorescence correlation spectroscopy.

Genotyping of human platelet antigen-1 (HPA-1) is required for the diagnosis and appropriate therapy of alloimmunization. Recently, the HPA-1 polymorphism has been identified as an inherited risk factor for thrombosis. Most currently used methods for HPA-1 genotyping have the disadvantage of time-consuming post-polymerase chain reaction (PCR) processes such as ligation (oligonucleotide ligation assay), restriction enzyme digestion (allele-specific restriction enzyme analysis) and electrophoresis (single-strand conformation polymorphism). We present a novel method for HPA-1 genotyping based on a homogeneous PCR strategy (GALIOS, gene amplification and labelling in one system) combined with automated fluorescence correlation spectroscopy (FCS). The PCR uses one pair of gene-specific amplification primers and two allele-specific, semi-nested labelling primers. The allele-specific labelling primers differ in a single nucleotide (T for HPA-1a/1a, C for HPA-1b/1b) and are coupled to different fluorescent dyes. The quantities of generated fluorescent PCR products are analysed by FCS at 543 nm and 633 nm excitation wavelength respectively. The genotypes determined using this method were in 100% concordance with the results obtained by allele-specific restriction analysis (n = 380 samples). The assay was validated for specificity, reliability and the dynamic range. This innovative method of rapid HPA-1 genotyping offers a specific and robust system, which is applicable for routine HPA-1 genotyping.

Antigens, Human Platelet↗

Analysis of human platelet antigen systems in a Moroccan Berber population.

The human platelet alloantigen systems HPA-1, -2, -3, -4, -5 and -6 in a Moroccan Berber population from the Amizmiz region were determined by polymerase chain reaction using sequence-specific primers (PCR-SSP). The gene frequencies obtained from these unrelated Berbers were 0 x 747 and 0 x 252 for HPA-1a and -1b; 0 x 817 and 0 x 182 for HPA-2a and -2b; 0 x 682 and 0 x 317 for HPA-3a and -3b; 1 and 0 x 0 for HPA-4a and -4b; 0 x 8616 and 0 x 1383 for HPA-5a and -5b; 1 and 0 x 0 for HPA-6a and -6b. The Berbers have the highest frequency for the 1b, 2b and 5b alleles of all the populations reported to date and also the lowest frequency for the 3b allele.

Antigens, Human Platelet↗