PubMed HealthSearch

PubMed · 9850588

A simple method for evaluating data from an interlaboratory study.

Abstract

Large-scale laboratory- and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT = [experimentally found among-laboratories relative standard deviation] divided by [relative standard deviation calculated from the Horwitz formula]). The chemical analytical method is deemed acceptable per se if HORRAT approximately 1.0 (+/- 0.5). If HORRAT is > or approximately 2.0, the most extreme values are removed successively until an "acceptable" ratio is obtained. The laboratories responsible for the extreme values that are removed should examine their technique and procedures. If > or approximately 15% of the values have to be removed, the instructions and the methods should be examined. This suggested computation procedure is simple and does not require statistical outlier tables. Proposed action limits may be adjusted according to experience. Data supporting U.S. Environmental Protection Agency method 245.1 for mercury in waters (manual cold-vapor atomic absorption spectrometry), supplemented by subsequent laboratory-performance data, were reexamined in this manner. Method-performance parameters (means and among-laboratories relative standard deviations) were comparable with results from the original statistical analysis that used a robust biweight procedure for outlier removal. The precision of the current controlled performance is better by a factor of 4 than that of estimates resulting from the original method-performance study, at the expense of rejecting more experimental values as outliers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Horwitz, P Britton, S J Chirtel. A simple method for evaluating data from an interlaboratory study.. https://pubmed.ncbi.nlm.nih.gov/9850588/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Coatings.

Explore the source record for details and available documents.

Chemistry Techniques, Analytical

Water analysis.

Explore the source record for details and available documents.

Chemistry Techniques, Analytical

On-line technique for measuring stable oxygen and hydrogen isotopes from microliter quantities of water.

Detailed here is a method for extracting and analyzing oxygen and hydrogen isotopes from 10 microL-sized water samples. Based on the traditional CO2-H2O equilibration technique, the oxygen isotope exchange reaction is done exclusively in sealed 6-mm (o.d.) Pyrex tubes at 25 degrees C, with full isotope exchange completed in at least 28 h. Using the same water sample employed in the 18O equilibration, D/H extractions are done in separate sealed 6-mm (o.d.) Pyrex tubes by reaction with Zn at 450 degrees C to form H2(g). Provided that a correction factor is applied to 18O analyses, accuracy and precision for both 18O and D/H are comparable to standard techniques using much larger samples.

Chemistry Techniques, Analytical