PubMed Health⌕ Search

PubMed · 9870373

Analyte identification in capillary electrophoretic separation techniques.

Abstract

A review on applications of on-line hyphenation in capillary electrophoresis and capillary electrochromatography for the identification of migrating analytes is presented. There is an urgent need for unambiguous analyte identification by combining spectral information and observed migration times, because the parameters influencing the migration times and separation efficiencies in these separation techniques are not easily controlled, especially when real samples containing unknown interferences have to be analyzed. The spectrometric techniques covered here are ultraviolet and visible radiation (UV/Vis) absorption, fluorescence including fluorescence line-narrowing spectroscopy, Raman spectroscopy, nuclear magnetic resonance and mass spectrometry. Attention is essentially confined to literature reports in which the extra information provided by the detector is really used for identification purposes, especially in real-life samples, while the interfacing as such and analyte detectabilities in standard solutions are only briefly discussed. This article covers an extensive fraction of the literature published on this topic until the beginning of 1998.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S J Kok, N H Velthorst, C Gooijer, U A Brinkman. 1998. Analyte identification in capillary electrophoretic separation techniques.. https://doi.org/10.1002/elps.1150191604

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel relationship between time offsets in capillary electrophoresis and DNA sequence variations in short tandem repeats.

Next-generation sequencing (NGS) provides increased discriminatory power in forensic DNA analysis due to the detection of isoalleles. Differences in sequences between alleles allow for a second layer of differentiation between DNA contributors beyond the number of short tandem repeat (STR) repeat units. However, because NGS is a more time and resource-intensive analysis than conventional capillary electrophoresis (CE), laboratories may benefit from indicators that suggest NGS is likely to provide added value. This study examined whether CE migration offsets, measured as residuals in the OSIRIS analysis software, can differ significantly among STR isoalleles. Residuals represent the time offset between a sample allele peak and its corresponding allelic ladder peak. Paired CE and NGS data from 95 single source samples were analyzed for CE-based residual differences, as the NGS data provided the sequence information of the corresponding isoalleles. Residual values differed significantly among isoalleles at several STR loci. Statistically significant differences were identified at D16S539 and D3S1358, as well as at specific allele lengths within D12S391, D13S317, and D8S1179. These findings demonstrate that CE residual variation can reflect underlying STR sequence differences between contributors. In practice, residual-based metrics could help laboratories to identify casework reference samples where NGS is likely to provide additional discrimination, without the need for processing outside of a routine CE workflow. Due to the potentially large number of isoalleles, community wide efforts to aggregate CE residual differences versus isoallele sequences may be useful in the validation and implementation of this approach to add value to forensic DNA analyses.

Electrophoresis, Capillary↗

Homogeneous fluorescent derivatization of large proteins.

A method of homogeneously derivatizing large proteins for highly sensitive analysis is described. Homogeneity of the derivative was realized by tagging all the free amino groups of proteins. With this method, alpha-chymotrypsinogen A, ovalbumin and bovine serum albumin were derivatized with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC). Prior to the derivatization, all the proteins were reduced and alkylated. After reacting the resulting unfolded proteins with excessive amounts of AQC, the samples were analyzed with matrix assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) to determine the derivatization degree. The results indicated that all three proteins had been, or had almost been, fully derivatized. HPLC and CE were used for characterizing these protein derivatives. Under the optimized fluorescence detection conditions, the detectability of the tagged proteins was 2400-6200 times better than that detected at UV 280 nm, 170-300 times better than detected at UV 214 nm, and 150-420 times better than measured with their native fluorescence.

Electrophoresis, Capillary↗

Practical method for evaluation of linearity and effective pathlength of on-capillary photometric detectors in capillary electrophoresis.

The optical characteristics of on-capillary photometric detectors for capillary electrophoresis were evaluated and five commercial detectors were compared. Plots of sensitivity (absorbance/concentration) versus absorbance obtained with a suitable testing solution yield both the linear range and the effective path length of the detector. The detector linearity is a crucial parameter when using absorbing electrolytes, such as for indirect photometric detection, and especially for highly absorbing electrolyte probe ions. The upper limits of the linear ranges (determined as 5% decline in sensitivity) for five commercial detectors ranged from 0.175 to 1.2 AU. The effective pathlength reflects the quality of the optical design of the detector and is equal to the capillary internal diameter only for a light beam passing exactly through the capillary centre, but becomes progressively shorter for imperfect optical designs. The determined effective pathlength for the five investigated detectors ranged from 49.7 to 64.6 microm for a 75 microm I.D. capillary.

Electrophoresis, Capillary↗