PubMed Health⌕ Search

PubMed · 9922084

EOG correction: a new aligned-artifact average solution.

Abstract

OBJECTIVE: In the field of EOG correction, discrepancies have been found between the propagation rates for different types and frequencies of eye movement. However, Croft and Barry demonstrated that these differences can be explained by the affect of EOG magnitude on the correction procedure (Croft, R.J. and Barry, R.J. EOG correction: a new perspective. Electroenceph. clin. Neurophysiol., 1998, 107: 387-394). This study utilized a new 'aligned-artifact average' technique (AAA) to examine whether propagation is constant across eye movement types and frequencies, and tested the AAA as an EOG correction tool. METHODS: Two experiments manipulated interference levels in real data sets to determine if interference affected propagation coefficients (Bs). The third tested real data for the effect of forward propagation of eye movement related neural potentials on Bs, and the fourth utilized computer simulations to assess the effectiveness of the new AAA correction procedure. RESULTS: Interference was found to inflate B at low EOG amplitude, and its removal removed B variation and inflation. The forward propagation of eye movement related neural potentials had very little effect on B. The AAA procedure produced near perfect corrections of the simulated data, superior to a comparison method. CONCLUSIONS: EOG propagation is constant across eye movement types and frequencies, and thus only one correction coefficient should be calculated and applied to data. The AAA method provides a more accurate correction and makes possible, for the first time, the adequate correction of posterior sites.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Croft, R J Barry. 1998. EOG correction: a new aligned-artifact average solution.. https://doi.org/10.1016/s0013-4694(98)00087-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗