Interstitial lung disease: A quantitative study using the adaptive multiple feature method.

Abstract

We have previously described an adaptive multiple feature method (AMFM) for the objective assessment of global and regional changes in pulmonary parenchyma to detect emphysema. This computerized method uses a combination of statistical and fractal texture features for characterization of lung tissues based upon high resolution computed tomography (HRCT) scans. This present study was a substantial extension of the AMFM to simultaneously discriminate between multiple pulmonary disease processes. Normal subjects and those with emphysema, idiopathic pulmonary fibrosis (IPF), or sarcoidosis were studied. The AMFM was compared with two currently utilized computer-based methods: mean lung density (MLD) and the histogram analysis (HIST). Globally, when comparing two-subject groups the AMFM overall accuracy was 2 to 18% better than the overall accuracy of MLD and as much as 36% better than the accuracy of the HIST methods. In three-subject group discrimination tasks, the AMFM performed 7 to 27% better than the MLD and 4 to 36% better than the HIST methods. Finally, in discriminating all four subject groups at a time, the AMFM overall accuracy was 81%, which was 21% better than the MLD and 25% better than the HIST method. In most three-subject group comparisons and in the four-subject group comparison, the AMFM was significantly (p < 0.01) better than the MLD and HIST methods. Next, the AMFM was applied to local discrimination between normal and each disease group individually. The normal versus emphysema, normal versus IPF, and normal versus sarcoidosis samples were discriminated with an accuracy of 95, 86, and 77%, respectively. The AMFM is an objective quantitative method that can be adapted for successful discrimination of multiple parenchymal lung diseases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Uppaluri, E A Hoffman, M Sonka, G W Hunninghake, G McLennan. 1999. Interstitial lung disease: A quantitative study using the adaptive multiple feature method.. https://doi.org/10.1164/ajrccm.159.2.9707145

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of the Sperm Quality Analyzer IIC variables with the computer-aided sperm analysis estimates.

Sperm Quality Analyzer (SQA) IIC, an upgrade version, is an inexpensive device and provides a quantitative estimation of sperm motility, whereas the use of computer-aided sperm analysis (CASA) provides high precision and provision of quantitative data on sperm kinetics. The aim of the present study was to evaluate if the SQA IIC variables correlated with the CASA estimates. Semen quality analysis of 71 fresh semen samples was performed using SQA IIC and CASA. Total sperm concentration, percentage of progressively motile sperm, percentage of normal morphology, motile sperm concentration, sperm motility index (SMI) and functional sperm count (FSC) determinations were performed using SQA IIC. Sperm concentration, sperm motility, and sperm motion variables including amplitude of lateral head displacement (ALH), beat cross frequency (BCF), curvilinear velocity (VCL), straight line velocity (VSL), average path velocity (VAP), linearity (LIN=VSL/VCL), and straightness (STR=VSL/VAP) were evaluated simultaneously on the same semen samples using CASA. The sperm characteristics were compared between SQA IIC and CASA. There were significant correlations of sperm concentration (r=0.634, p < 0.0001), sperm motility (r=0.697, p < 0.0001), and motile sperm concentration (r=0.757, p < 0.0001) between the two devices. Both SMI and FSC significantly correlated with eight CASA estimates, including sperm concentration, sperm motility, motile sperm concentration, ALH, VCL, VSL, VAP, and Rapid. SQA IIC is simple and easy to use. Moreover, the SQA IIC variables well correlated with the CASA estimates. As a screening test for semen quality, SQA IIC is considered as useful in the management of male infertility.

Diagnosis, Computer-Assisted↗

Comparing machine learning classifiers for diagnosing glaucoma from standard automated perimetry.

PURPOSE: To determine which machine learning classifier learns best to interpret standard automated perimetry (SAP) and to compare the best of the machine classifiers with the global indices of STATPAC 2 and with experts in glaucoma. METHODS: Multilayer perceptrons (MLP), support vector machines (SVM), mixture of Gaussian (MoG), and mixture of generalized Gaussian (MGG) classifiers were trained and tested by cross validation on the numerical plot of absolute sensitivity plus age of 189 normal eyes and 156 glaucomatous eyes, designated as such by the appearance of the optic nerve. The authors compared performance of these classifiers with the global indices of STATPAC, using the area under the ROC curve. Two human experts were judged against the machine classifiers and the global indices by plotting their sensitivity-specificity pairs. RESULTS: MoG had the greatest area under the ROC curve of the machine classifiers. Pattern SD (PSD) and corrected PSD (CPSD) had the largest areas under the curve of the global indices. MoG had significantly greater ROC area than PSD and CPSD. Human experts were not better at classifying visual fields than the machine classifiers or the global indices. CONCLUSIONS: MoG, using the entire visual field and age for input, interpreted SAP better than the global indices of STATPAC. Machine classifiers may augment the global indices of STATPAC.

Diagnosis, Computer-Assisted↗