PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ATMOSPHERIC PRESSURE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Atmospheric pressure ionisation multiple mass spectrometric analysis of pesticides.

Liquid chromatography-multiple mass spectrometry (LC-MS") has been investigated for analysis of polar pesticides in water using an ion-trap instrument and atmospheric pressure ionisation. Carbamate, triazine and phenylurea pesticides were best ionised as positive ions with atmospheric pressure chemical ionisation, while phenoxy acid herbicides, nitrophenols and bentazone yielded stronger signals as negative ions with pneumatically assisted electrospray. The ion fragmentation processes and pathways were studied in detail by MS, MS2, MS3 and MS4. All compounds were observed as their protonised or deprotonised molecular ions by MS and in the successive fragmentation by MS" the structures of typical (diagnostic) product ions were tentatively identified for each class of pesticide. Phenylureas yield an ion at m/z 72 by MS2, corresponding to O=C=N+(CH3)2. Carbamates produce [M+H-CONCH3]+ fragments by MS2 from neutral loss of methylisocyanate. Characteristic fragmentation pathways for triazine pesticides are [M+H]+-->m/z 174-->m/z 146-->m/z 110 and [M+H]+-->m/z 174-->m/z 132-->m/z 104 by MS-MS2-MS3-MS4 from cleavage of lateral chains in the triazine ring followed by ring opening. Phenoxy acid herbicides produce peculiar fragments by MS2 from loss of the acidic group possibly as the corresponding lactone. Nitrophenols are subject to loss of both *OH radical and NO groups thereby forming the correspondent phenols and quinones. The performance of the method with respect to quantitation compares favourably with traditional methods. With the ion-trap run in a time scheduled single ion monitoring mode, typical limits of detection (LODs) are in the low pg range and the repeatability standard deviations are between 3 and 15%. Assuming extraction of 1-l water samples and 1 ml final volumes the injection of 50-microl aliquots corresponds to LODs well below the requirement for the European Union water directive (EC/80/778).

Atmospheric Pressure↗

Benzodiazepine agonist and inverse agonist coupling in GABAA receptors antagonized by increased atmospheric pressure.

Past work found that exposure to 12 times normal atmospheric pressure (ATA) of helium-oxygen gas (heliox) selectively antagonizes (uncouples) and differentiates allosteric coupling in GABA(A) receptors initiated by benzodiazepines versus neurosteroids. The present study tested the hypothesis that pressure can differentiate coupling initiated by a spectrum of benzodiazepine receptor ligands by measuring the effects of pressure on benzodiazepine ligand modulation of GABA-activated 36Cl(-) uptake in mouse brain membranes. 12 ATA completely antagonized allosteric modulation by: benzodiazepine receptor agonists diazepam and flunitrazepam; Type-1 selective benzodiazepine receptor agonist zolpidem and the benzodiazepine receptor partial inverse agonist ethyl-8-azido-5,6-dihydro-5-methyl-6-oxo-4H-imidazo[1,5-alpha][1,4]benzodiazepine-3-carboxylate (Ro15-4513). The similar, non-competitive-like characteristics of pressure antagonism of these ligands suggest common structural/functional elements underlying their coupling. Pressure also antagonized allosteric modulation by the benzodiazepine receptor inverse agonist methyl 6,7-dimethoxy-4-ethyl-beta-carboline-3-carboxylate (DMCM), but the antagonism was not complete and appeared to be surmountable (competitive-like) suggesting unexpected differences in coupling for DMCM versus Ro15-4513. These studies represent the first attempt to use pressure as a tool to dissect benzodiazepine receptor coupling. The results suggest that there is a common, pressure antagonism sensitive structural/functional element underlying coupling for benzodiazepine receptor ligands and that coupling for the full inverse benzodiazepine receptor agonist DMCM differs from coupling for benzodiazepine receptor agonists and benzodiazepine receptor partial inverse agonists.

Animals↗

Trace determination of caffeine in surface water samples by liquid chromatography--atmospheric pressure chemical ionization--mass spectrometry (LC-APCI-MS).

A new method based on liquid-liquid extraction (LLE) coupled to reverse phase liquid chromatography and atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS) has been applied to determine trace amounts of caffeine (1,3,7-trimethylxanthine) in surface water samples from a near coastal ecosystem such as Biscayne Bay, Florida. The rational behind the development of such method will be to evaluate the use of unmetabolized caffeine as a potential dissolved phase tracer of human waste contamination. The method allows for the determination of caffeine at levels as low as 4.0 ng/l (ppt) in both salt and freshwater by extracting and concentrating a 1-1 water sample to a final volume of 500 microl and using HPLC separation coupled to an atmospheric pressure chemical ionization mass spectrometry (APCI-MS) system operated in selected ion monitoring (SIM) for the protonated molecular ions (M + H(+)). Samples from different portions of Biscayne Bay and the Miami River, one of its major tributaries, were analyzed and caffeine was detected in those areas previously identified for consistently exceeding the water quality criteria for fecal coliform bacteria contamination. The caffeine concentration in the samples with positive detection was generally low at levels equal or lower than 41 ng/l. However, there is a marked difference between samples collected in open bay areas and those collected from the Miami River.

Atmospheric Pressure↗

Miniaturized mass-selective detector with atmospheric pressure chemical ionization.

The miniaturized mass-spectrometric detector with atmospheric pressure chemical ionization (APCI) is described. The analyzer employed in this instrument is the monopole with rod 54 mm in length and 2 mm in radius, which retains its efficiency up to 0.13 Pa ( approximately 10(-3)Torr). Together with the ion source, channeltron ion detector, radio frequency power supply and preamplifier, it is packed into a case with dimension of 185 mm x 100 mm x 70 mm. Mass spectrometer with the whole vacuum system weighs about 20 kg. In spite of low power of the vacuum system, the limit of detection at ppt level is achieved. The "strong" fragmentation mode is suggested for high-specific detection of phosphor-containing substances. The detector conforms to multicapillary column attachment.

Atmospheric Pressure↗

Determination of ZD9583, a thromboxane receptor antagonist, in human plasma and urine by liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry.

A liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry (LC-APCI-MS-MS) method is described for the determination of a thromboxane receptor antagonist (4Z)-6-((2S,4S,5R)-2-(1-(2-cyano-4-methylphenoxy)-1-methylethyl)-4 -(3-pyridyl)-3-dioxan-5-yl)hex-4-enoic acid (ZD9583, I) in human plasma and urine. Proteins in plasma and urine samples are precipitated using acidified acetonitrile. The resulting supernatant is chromatographed on a C8 reversed-phase chromatography column. Following the diversion of the solvent front from the mass spectrometer by a switching valve, the column eluate is passed on to the mass spectrometer via a heated nebulizer interface where the analyte is detected by multiple reaction monitoring (MRM). The method has a chromatographic run time of less than 2 min, a linear calibration curve with a range of 1-500 ng ml(-1) and intra- and inter-day precision estimates of less than 10% over the calibration range.

Atmospheric Pressure↗

Atmospheric pressure MALDI Fourier transform mass spectrometry of labile oligosaccharides.

An atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) source coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT ICR MS) under UV laser and solid matrix conditions has been demonstrated to analyze a variety of labile oligosaccharides including O-linked and N-linked complex glycans released from glycoproteins. Spectra were acquired by both AP MALDI and vacuum MALDI and directly compared. The results presented here confirm that AP MALDI can generate significantly less energetic ions than vacuum MALDI and is able to produce the intact molecular ions with little or no fragmentation in both positive and negative ion mode analyses. Under certain conditions, noncovalent complexes of sialylated oligosaccharides were observed. The sensitivity attainable by AP MALDI was found to be comparable to conventional MALDI, and tandem mass spectrometry of oligosaccharides ionized by AP MALDI was shown to allow detailed structural analysis. Analysis of N-glycan mixtures derived from human fibrinogen further demonstrated that AP MALDI-FT ICR MS is ideal for the study of complex glycan samples as it provides high-accuracy, high-resolution mass analysis with no difficulty in distinguishing sample constituents from fragment ions.

Atmospheric Pressure↗

Atmospheric pressure MALDI-FTMS of normal and chemically modified RNA.

Atmospheric pressure (AP) MALDI has been combined with Fourier transform mass spectrometry (FTMS) to obtain the unambiguous characterization of RNA samples modified by solvent accessibility reagents used in structural studies of RNA and protein-RNA complexes. The formation of cation adducts typical of MS analysis of nucleic acids was effectively reduced by extensive washing of the anionic analytes retained onto the probe surface by strong interactions with a cationic layer of poly(diallyldimethylammonium chloride) (PADMAC). This rapid desalting procedure allowed for the detection of DNA and RNA samples in high femtomole quantities distributed over a 4 x 4 mm sample well. AP MALDI-FTMS was shown to provide high-resolution spectra for analytes as large as approximately 6.4 kDa with little or no evidence of metastable decomposition. The absence of significant metastable decay observed for precursor ions selected for tandem experiments offered a further measure of the low energy content typical of ions generated by AP MALDI. This feature proved to be very beneficial in the characterization of chemically modified RNA samples, which become particularly prone to base losses upon alkylation. The high resolution offered by FTMS enabled the application of a data-reduction algorithm capable of rejecting any signal devoid of plausible isotopic distribution, thus facilitating the analysis of complex analyte mixtures produced by nuclease treatment of RNA substrates. Proper selection of nucleases and digestion conditions can ensure the production of hydrolytic fragments of manageable size, which could extend the range of applicability of this bottom-up strategy to the structural investigation of very large RNA and protein-RNA complexes.

Atmospheric Pressure↗

Rapid and conservative ablation and modification of enamel, dentin, and alveolar bone using a high repetition rate transverse excited atmospheric pressure CO2 laser operating at lambda=9.3 micro.

Transverse excited atmospheric pressure (TEA) CO(2) lasers tuned to the strong mineral absorption of hydroxyapatite near lambda=9 microm are well suited for the efficient ablation of dental hard tissues if the laser pulse is stretched to greater than 5 to 10 micros to avoid plasma shielding phenomena. Such CO(2) lasers are capable of operating at high repetition rates for the rapid removal of dental hard tissues. The purpose of this study was to test the hypothesis that stretched lambda=9.3-microA CO(2) laser pulses can produce lateral incisions in enamel, dentin, and alveolar bone for dental restorations and implants at repetition rates as high as 400 Hz without peripheral thermal damage. The single pulse ablation rates through enamel, dentin, and bone were determined for incident fluence ranging from (1 to 160 J/m(2)) for laser pulses from 5 to 18 mus in duration. Lateral incisions were produced in hard tissue samples using a computer-controlled scanning stage and water spray, and the crater morphology and chemical composition were measured using optical microscopy and high-resolution synchrotron radiation infrared spectromicroscopy. The residual energy remaining in tooth samples was measured to be 30 to 40% for enamel and 20 to 30% for dentin without water cooling, under optimum irradiation intensities, significantly lower than for longer CO(2) laser pulses. The transmission through 2-m length 300-, 500-, 750-, and 1000-microm silica hollow waveguides was measured and 80% transmission was achieved with 40 mJ per pulse. These results suggest that high repetition rate TEA CO(2) laser systems operating at lambda=9.3 microm with pulse durations of 10 to 20 micros are well suited for dental applications.

Animals↗

Analysis of underivatized amino acid mixtures using high performance liquid chromatography/dual oscillating nebulizer atmospheric pressure microwave induced plasma ionization-mass spectrometry.

A dual oscillating capillary nebulizer (OCN) in conjunction with an atmospheric pressure microwave induced plasma ionization (AP-MIPI) source was applied to the analysis of underivatized amino acid mixtures. It was found that, compared to the single OCN, the dual OCN enhanced the sensitivity of detection several fold. Enhanced sensitivity was compound dependent. For small molecules, such as amino acids, it was 2-5 times more sensitive, while for larger molecules such as peptides it was more than an order of magnitude. The increase in sensitivity was attributed to the enhanced nebulization of the new torch. By using water/ acetonitrile containing 0.1% nonafluoropentanoic acid as the high performance liquid chromatography (HPLC) mobile phase and a C18 column, all common amino acids were separated and detected. A comparison between the results obtained using microwave induced plasma, atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) at flow rates compatible with micro LC (10-100 microL/min) showed a higher sensitivity of detection with the AP-MIPI technique for the analysis of underivatized amino acids.

Journal Article↗

Mechanism of hearing disturbance due to alteration in atmospheric pressure.

We used a soundproof pressure chamber to examine how the changes in atmospheric pressure as experienced in daily life reduces bone conduction in a total of 48 normal adults. The subjects were given special ear plugs that connected external auditory canal to the pressure gauge and a small pump located outside the chamber, and were instructed not to swallow, to avoid active opening of the Eustachian tube. The chamber pressure was increased (or decreased) to +/- 500 mmH2O at a rate of 33 mmH2O/s. Then pressure in the external auditory canal was increased (or decreased) gradually after the chamber pressure had reached +/- 500 mmH2O, to equilibrate the pressure across the ear drum. Bone conduction did not recover the level before increase (or decrease) in the chamber pressure. We conclude that at least a minor part of the deterioration in bone conduction after changes in the chamber pressure was caused by displacement of the round window membrane.

Adult↗

Quantitation of lanosterol and its major metabolite FF-MAS in an inhibition assay of CYP51 by azoles with atmospheric pressure photoionization based LC-MS/MS.

Azoles affect the steroid balance in all biological systems and may therefore be called endocrine disrupters. Lanosterol 14alpha-demethylase (CYP51) is an enzyme inhibited by azoles. Only few data have been reported showing their inhibitory potency since an assay in an in vitro system is not available so far. In the present work an inhibition assay using human recombinant CYP51, coexpressed with human P450 oxido-reductase by the baculovirus/insect cell expression system, and LC-MS/MS as analytical method is described. Atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were used with a triple quadrupole mass spectrometer to compare quantitation of lanosterol (substrate) and 4,4-dimethyl-5alpha-cholesta-8,14,24-triene-3beta-ol (FF-MAS) (product of CYP51) with d(6)-2,2,3,4,4,6-cholesterol (d(6)-cholesterol) as internal standard. Optimization of analytical parameters resulted in a LC-APPI-MS/MS method with a LOQ of 10 pg on column for FF-MAS. The sensitivity of the method (LOD 0.5 ng/ml) makes it possible to analyze supernatants of inhibition experiments after precipitation of proteins by isopropanol without any sample enrichment. The coefficient of variation of the analytical method was <20% (n = 5) for FF-MAS, lanosterol and d(6)-cholesterol. The external calibration curve was linear from 1 to 10,000 ng/ml with R(2) >/= 0.999 and an accuracy of 94-115%. Compared with APCI, APPI provides a ten- to 500-fold increase in sensitivity for the analytes in this study. IC(50) values of epoxiconazole and miconazole-two widely used azole fungicides used in agriculture and in human medicine, respectively-were 1.95 microM and 0.057 microM.

Azoles↗

High-performance liquid chromatography-atmospheric pressure chemical ionisation-mass spectrometry determination of zaleplon in human plasma.

A sensitive and specific liquid chromatography-atmospheric pressure chemical ionisation-mass spectrometry (LC-APCI-MS) method has been developed and validated for the identification and quantification of zaleplon in human plasma using estazolam as an internal standard (IS). After the addition of estazolam and 2.0 M sodium hydroxide solution, plasma samples were extracted with ethyl acetate and then the organic layer was evaporated to dryness. The reconstituted solution of the residue was injected onto a prepacked Shim-pack VP-ODS C18 (250 mm x 2.0 mm i.d.) column and chromatographed with a mobile phase comprised of methanol:water (70:30) at a flow-rate of 0.2 ml/min. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via atmospheric pressure chemical ionization (APCI) source. The mean standard curve was linear (r = 0.9991) over the concentration range of 0.2-100 ng/ml and had good back-calculated accuracy and precision. The intra-day and inter-day precisions were within 10% relative standard deviation and accuracy ranged from 85% to 115%. The limit of detection was 0.1 ng/ml. The validated LC-APCI-MS method has been used successfully to study zaleplon pharmacokinetic, bioavailability and bioequivalence in 18 adult volunteers.

Acetamides↗

Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry.

The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion scans on most abundant background ions to draw a family tree of the commonly occurring chemical background ions. The possible structures and the origins of the major chemical background noise are clearly revealed in the family trees. In agreement with some suggestions in the literature, the chemical background ions studied so far can be classified mainly as either ions of contaminants (or their degradation fragments) or cluster-related ones. A significant contribution from the contaminants (airborne, from tubing and/or solvents) from plasticizer additives (phthalates, phenyl phosphates, sebacates and adipates, etc.) and silicones is concluded. These ions of contaminants can also serve as nuclei for the clustering of HPLC solvent or additives, such as water and acetic acid, thereby leading to a second family of background ions. This study explains the persistence of some chemical background noise even under fairly strong declustering conditions in API LC/MS. One of the other interesting conclusions is that there is a clear difference in structures between the chemical background ions and the protonated analytes generated under atmospheric pressure ionization. This conclusion will contribute to the on-going research efforts to exclusively remove or reduce the interference of chemical background noise in API LC/MS.

Journal Article↗

Atmospheric pressure matrix-assisted laser desorption/ionization in transmission geometry.

In both atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) and vacuum MALDI, the laser typically illuminates the analyte on the front side of an opaque surface (reflection geometry). Another configuration consisting of laser illumination through the sample backside (transmission geometry) has been used in conventional MALDI; however, its use and the number of reports in the literature are limited. The viability of transmission geometry with AP MALDI is demonstrated here. Such a geometry is simple to implement, eliminates the restriction for a metallic sample holder, and allows for the potential analysis of samples on their native transparent surfaces, e.g., cells or tissue sections on slides.

Angiotensin I↗

Screening for library-assisted identification and fully validated quantification of 22 beta-blockers in blood plasma by liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization.

A liquid chromatographic-mass spectrometric assay with atmospheric pressure chemical ionization (LC-APCI-MS) is presented for screening for, library-assisted identification (both in scan mode) and quantification (selected-ion mode) of the beta-blockers acebutolol, diacetolol, alprenolol, atenolol, betaxolol, bisoprolol, bupranolol, carazolol, carteolol, carvedilol, celiprolol, esmolol, labetalol, metoprolol, nadolol, nebivolol, oxprenolol, penbutolol, propranolol, sotalol, talinolol and timolol in blood plasma after mixed-mode (HCX) solid-phase extraction (SPE) and separation by reverse-phase liquid chromatography with gradient elution. The validation data were within the required limits. The assay was successfully applied to authentic plasma samples allowing confirmation of diagnosis of overdose situations as well as monitoring of patients' compliance.

Adrenergic beta-Antagonists↗

Positive and negative gas-phase ion chemistry of chlorofluorocarbons in air at atmospheric pressure.

This paper presents a report on the ionization/dissociation of some representative chlorofluorocarbons (CFCs) induced by corona discharges in air at atmospheric pressure. Both positive and negative ions formed from Freons 1,1,1-trichlorotrifluoroethane (CFC 113a), 1,1,2-trichlorotrifluoroethane (CFC 113), and 1,1,1,2-tetrachlorodifluoroethane (CFC 112a) were analyzed using an atmospheric pressure chemical ionization mass spectrometry (APCI-MS) instrument. Energy-resolved mass spectra were obtained by modulating the kinetic energy of the ions via adjustment of the sampling cone potential (V(cone)). Positive ion spectra of the CFCs (M) at low V(cone) show no signals due to either M(+)* or MH(+) but only those due to species [M - Cl](+) and CX(3)(+) (X = Cl, F), likely formed via C-Cl and C-C bond cleavages following ionization via charge exchange. Charge localization in the products of C-C bond cleavage in M(+)* is driven by the stability of the neutral fragment. At low V(cone) the hydrates [M - Cl](+)(H(2)O) are also observed. In the case of 1,1,2,-trichlorotrifluoroethane, [M - F](+) species also form as a result of ion-molecule reactions. As V(cone) is increased collision-induced dissociation of [M - Cl](+) and [M - F](+), i.e., the perhalogenated cations C(2)X(5)(+) (X = Cl, F), takes place via carbene elimination. In some cases such elimination is preceded or accompanied by rearrangements involving transfer of halogen from one carbon to the other. Evidence is also presented for the occurrence of a condensation reaction of C(2)Cl(3)F(2)(+) with water to form a C(2)Cl(2)F(2)HO(+) species via elimination of HCl. Negative ion spectra are dominated by Cl(-) and its ion-neutral complexes with M and with water. Additional components of the plasma include ion-neutral complexes O(3)(-)(M), the molecular anion M(-) (observed only with 1,1,2-trichlorotrifluoroethane), and an interesting species corresponding to [M - Cl + O](-). The origin and structure of these [M - Cl + O](-) species are discussed in terms of available thermochemical and reactivity data and current mechanistic views concerning reaction of O(2)(-) with halogenated compounds. The observation of both positive and negative ions containing oxygen is of special relevance to development of new processes for the treatment of volatile organic compounds (VOCs) based on oxidative decomposition induced by corona discharges in air at room temperature and pressure.

Journal Article↗

Acetonitrile/water gas-phase reaction products observed by use of atmospheric pressure chemical ionization: adducts formed with sulfonamides.

Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are the two most common mass spectrometric ionization methods used in the pharmaceutical industry. However, APCI analysis can sometimes lead to ambiguity in compound characterization and quantitation due to gas-phase reactions occurring between acetonitrile and water in the plasma, and between these plasma-generated compounds and the analyte. During the analysis of various sultams and sulfonamides we observed signals corresponding to m/z [M+44](+) and [M+60](+). Various solvent conditions and collisionally activated dissociation MS(n) experiments revealed that under the high-energy plasma conditions of APCI, the acetonitrile/water solvent mixture reacts undergoing acid-catalyzed hydrolysis producing acetamide, 59 Da. Further, the highly reactive 43 Da species ethanimine is also produced. These two compounds, normally not observed in APCI analysis, are stabilized by the sulfonamide and appear as adduct species in the mass spectra. The sulfone oxygens and the lone pair of electrons on the amide nitrogen play a role in stabilizing this adduct.

Acetonitriles↗

Action spectra for survival and spore photoproduct formation of Bacillus subtilis irradiated with short-wavelength (200-300 nm) UV at atmospheric pressure and in vacuo.

Spores of Bacillus subtilis are approximately ten times less likely to survive UV light irradiation in a vacuum than under atmospheric conditions. Photoproduct formation was studied in spores irradiated under ultrahigh vacuum (UHV) conditions and in spores irradiated at atmospheric pressure. In addition to the "spore photoproduct" 5-thyminyl-5,6-dihydrothymine (TDHT), which is produced in response to irradiation at atmospheric pressure, two additional photoproducts, known as the cis-syn and trans-syn isomers of thymine dimer, are produced on irradiation in vacuo. The spectral efficiencies for photoproduct formation in spores are reduced under vacuum conditions compared with atmospheric conditions by a factor of 2-6, depending on the wavelength. Because formation of TDHT does not increase after irradiation in vacuo, TDHT cannot be responsible for the observed vacuum effect. Vacuum specific photoproducts may cause a synergistic response of spores to the simultaneous action of UV light and UHV. An increased quantum efficiency, destruction of repair systems and formation of irreparable lesions are postulated for the enhanced sensitivity of B. subtilis spores to UV radiation in vacuo.

Bacillus subtilis↗