PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Anatomic Landmarks”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Transseptal left heart catheterization for cardiac ablation procedures.

UNLABELLED: Transseptal left heart catheterization has been performed as an alternative to the retrograde approach since 1958. However, this procedure can result in life-threatening complications, some of which may occur because of insufficient anatomical landmarks. Accordingly, we sought to assess the safety and efficacy of a new transseptal left heart catheterization technique designed for ablation procedures. Specifically, we examined whether electrode catheters could be used as anatomical landmarks, permitting identification of the aortic root and other critical structures. RESULTS: One hundred and eight consecutive patients underwent transseptal left heart catheterization under biplane fluoroscopy during catheter ablation. Electrode catheters positioned in the right atrial appendage, His bundle region, and coronary sinus were used as anatomical landmarks to guide the transseptal unit to the fossa ovalis. The angles of the right anterior and left anterior oblique projections were selected in each patient based on the orientation of the His bundle and coronary sinus catheters. Transseptal left heart catheterization was successfully performed in all patients without complications. In contrast to previous reports, the direction of the needle at the successful puncture site in the last 96 patients varied substantially: 2 o'clock in 13 patients (13 %); 3 o'clock in 43 patients (45 %); and 4 o'clock in 40 patients (42 %). CONCLUSION: The use of electrode catheters as anatomical landmarks and biplane fluoroscopy facilitates transseptal catheterization. This approach can be used safely during catheter ablation procedures.

Adolescent↗

Role of intracardiac ultrasound in interventional electrophysiology.

PURPOSE OF REVIEW: Interventional procedures in the electrophysiology and catheterization laboratory are rapidly advancing. Critical to the advancement of these procedures is accurate identification of critical anatomic landmarks and catheter position. Fluoroscopy remains the mainstay for general identification of anatomic landmarks but is inadequate for the precise imaging needed for complex procedures. Precise imaging of anatomic landmarks and catheter position is now possible during the procedure with the use of intracardiac echocardiography (ICE). This paper reviews the rapid development and utilization of ICE in interventional electrophysiology. RECENT FINDINGS: Several recent studies show ICE as a major contribution to providing a safer, more reliable, and more cost-effective means of accomplishing the tasks performed by existing techniques. In the electrophysiology laboratory, the dependence on this new technology has been due to the rapid development of catheter-based radiofrequency ablation of the pulmonary veins for treatment of atrial fibrillation. Since the initial use of ICE in facilitating ablation of atrial fibrillation, other uses for ICE are continuously being identified. SUMMARY: A comprehensive look is provided at the history and development of this new technology along with the most recent applications of ICE in interventional electrophysiology.

Atrial Fibrillation↗

Safe treatment of trigger finger with longitudinal and transverse landmarks: an anatomic study of the border fingers for percutaneous release.

Transverse landmarks have recently been determined to predict the proximal and distal edges of the A1 pulley for trigger finger release. Percutaneous A1 pulley release has been discouraged for the border digits because of the risk of injury to the neurovascular structures of the index and small fingers. The purpose of the study was to identify longitudinal surface landmarks to prevent injury to the neurovascular bundles during percutaneous A1 pulley release of the ulnar and radial border digits. Longitudinal surface landmarks were identified and marked on 29 cadaver hands. Proximal and distal landmarks for the longitudinal vector through which the A1 pulley of the small finger was released include the midline of the proximal digital crease and the scaphoid tubercle. Proximal and distal landmarks for the longitudinal line through which the index finger A1 pulley was released include the midline of proximal digital crease and radial edge of the pisiform. Longitudinal incisions were performed between these landmarks, straight through the skin and deep enough to score the A1 pulley. The distance of the medial edge of the neurovascular structures from the longitudinal incision in the A1 pulley was measured for each small finger and index finger. Using these longitudinal landmarks for the index and small fingers, none of the neurovascular structures was injured while performing these longitudinal incisions through the skin, scoring the A1 pulley. In fact, the average distance for the neurovascular structures from the longitudinal vector of the small finger was 5.4 +/- 1.4 mm radially and 6.7 +/- 1.9 mm ulnarly. The average distance for the neurovascular structures from the longitudinal line of the index finger was 8.5 +/- 1.8 mm radially and 6.2 +/- 1.7 mm ulnarly. Based on the findings of this anatomical study, these longitudinal landmarks can be used to avoid injury to neurovascular structures in the management of trigger finger involving the border digits with steroid-injection, open, or percutaneous A1 pulley release.

Cadaver↗

The central sulcal vein: a landmark for identification of the central sulcus using functional magnetic resonance imaging.

The authors evaluated the anatomical location of the central sulcus (CS) in 24 cerebral hemispheres (eight in which tumors were located centrally, 16 in controls) using: 1) classic anatomical landmarks seen on magnetic resonance (MR) imaging (24 hemispheres); 2) functional MR imaging (24 hemispheres); and 3) intraoperative electrical stimulation mapping (eight hemispheres). On MR imaging the CS was identified with certainty in 79% of hemispheres (four of eight in patients, 15 of 16 in controls). Functional MR imaging identified a parenchymal "motor hand area" in only 83% (20 of 24 hemispheres; five of eight in patients, 15 of 16 in controls); this area was located in the precentral gyrus in 16 (80%) of 20, additionally in the postcentral gyrus in 10 (50%) of 20, and exclusively in the postcentral gyrus in four (20%) of 20. In contrast, functional MR imaging detected one to three sulcal veins presumably draining blood from the adjacent motor hand area in 100% (24 of 24) of the hemispheres studied, and anatomical MR imaging and intraoperative mapping localized these veins in the CS. It is concluded that sulcal veins lying deep within the CS: 1) drain activated blood from the adjacent pre- or postcentral cortex during performance of a motor hand task; 2) can be identified easily with functional MR imaging; and 3) are an anatomical landmark for noninvasive identification of the CS and thus the sensorimotor strip. The detection of these veins provides a more consistent landmark than the detection of parenchymal motor areas by functional MR imaging; this technique may be used when classic anatomical landmarks fail to identify the sensorimotor strip.

Adult↗

Reliability and validity of arm volume measurements for assessment of lymphedema.

BACKGROUND AND PURPOSE: Arm lymphedema following breast cancer surgery is a continuing problem. In this study, we assessed the reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. SUBJECTS: Participants included subjects who had had breast cancer surgery, including axillary dissection--19 with and 22 without a diagnosis of arm lymphedema--and 25 control subjects. METHODS: Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatomic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. RESULTS: Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based on anatomic landmarks was lower than that based on distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. DISCUSSION AND CONCLUSION: Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.

Adult↗

An anatomically guided approach to atrioventricular node slow pathway ablation.

Radiofrequency ablation of the "slow" pathway of the atrioventricular (AV) node reentrant circuit may be guided by electrophysiologic ("slow pathway potential") or anatomic landmarks. Experience with a systematic, anatomically guided approach in 25 patients (20 women and 5 men, aged 38 +/- 15 years) with typical AV node reentry is described. The slow pathway is assumed to be the posterior input to the AV node, approaching the nodal region in the corridor between the tricuspid annulus and the orifice of the coronary sinus. A series of radiofrequency lesions are given to interrupt this corridor at its entrance to Koch's triangle. If this is unsuccessful, the series of lesions are repeated progressively at higher levels approaching the AV node. The major end point for success is elimination of the slow pathway as determined by extrastimulus testing. A mean of 1.2 +/- 0.2 ablative sessions (20 +/- 12 applications of energy) achieved clinical success in 24 of 25 patients (96%) at a follow-up of 8.6 +/- 2.2 months. Anterograde Wenckebach cycle length increased from 361 +/- 67 ms to 398 +/- 70 ms (p = 0.01), yet the atrio-Hisian interval in sinus rhythm did not change (69 +/- 17 ms before vs 65 +/- 15 ms after ablation), p = 0.22. Retrograde Wenckebach cycle length was not affected (348 +/- 78 ms before vs 366 +/- 82 ms after ablation). During ablation, transient third-degree AV block occurred in 6 patients with no permanent sequelae. This approach provides a systematic, expedient technique to eliminate slow pathway conduction based on anatomic landmarks.

Adult↗

Position and orientation in space of bones during movement: anatomical frame definition and determination.

This paper deals with methodological problems related to the reconstruction of the position and orientation of the human pelvis and the lower limb bones in space during the execution of locomotion and physical exercises using a stereophotogrammetric system. The intention is to produce a means of quantitative description of joint kinematics and dynamics for both research and application. Anatomical landmarks and bone-embedded anatomical reference systems are defined. A contribution is given to definition of variables and relevant terminology. The concept of anatomical landmark calibration is introduced and relevant experimental approaches presented. The problem of data sharing is also addressed. This material is submitted to the scientific community for consideration as a basis for standardization. RELEVANCE: In order to make movement analysis effective in the solution of clinical problems, a structured conceptual background is needed in addition to standardized definitions and methods. Technical solutions which make data sharing and relevant data banks possible are also of primary importance. This paper makes suggestions in this context.

Journal Article↗

Radiofrequency catheter ablation of common atrial flutter in 80 patients.

OBJECTIVES: The purpose of this study was to evaluate the efficacy and safety of radiofrequency catheter ablation of common atrial flutter and to determine the optimal target sites in a large series of patients. BACKGROUND: Recent studies report the efficacy of radiofrequency current application in the low right atrial region to interrupt and prevent recurrences of common atrial flutter. However, larger groups of patients are required to confirm the efficacy of this technique and to specify the target sites. METHODS: Two different approaches were used to target the ablation site in 80 consecutive patients. In the first 50 patients, target sites were localized using both anatomic landmarks and electrophysiologic variables. Three anatomic landmarks were used: area 1 = between the tricuspid valve and inferior vena cava orifice; area 2 = between the tricuspid valve and coronary sinus ostium; area 3 = between the inferior vena cava and coronary sinus. The electrophysiologic criterion was to ablate when there was a stable atrial electrogram during the plateau phase. In the next 30 patients we assessed the effect of application of radiofrequency energy in a single line in area 1, 2 or 3 in groups of 10 patients. RESULTS: Overall atrial flutter was interrupted and rendered noninducible after a single session in 72 patients (90%) and could not be interrupted in 8 (10%). The mean (+/- SD) number of radiofrequency applications was 12 +/- 8. After a mean (+/- SD) follow-up of 20 +/- 8 months, recurrences occurred in 14 patients (17%). The location of the final successful site in the first group of 50 patients was in area 1 in 39%, area 2 in 36% and area 3 in 25%. In the next 30 patients, when lines of radiofrequency lesions were placed at several sites, they produced success rates of 70%, 40% and 10% at areas 1, 2 and 3, respectively. CONCLUSIONS: Radiofrequency catheter ablation of atrial flutter can be performed with a high success rate and is safe. The highest success rate is achieved with radiofrequency energy applied in the isthmus between the inferior vena cava orifice and tricuspid valve.

Actuarial Analysis↗

Radiofrequency catheter ablation of common atrial flutter in 200 patients.

INTRODUCTION: The purpose of this study was to evaluate the efficacy and safety of radiofrequency (RF) catheter ablation of common atrial flutter and to determine the optimum target sites in a large series of patients. Three different approaches were used to target the ablation site. The first used a combined anatomic and electrophysiologic approach, whereas the second and the third approaches relied primarily on anatomic guidelines to target the critical area in the atrial flutter reentrant circuit located in the low right atrium. BACKGROUND: Recent studies report the efficacy of RF current application in the low right atrial region to interrupt and prevent recurrences of common atrial flutter using either anatomic or electrophysiologic targets. However, larger groups of patients are required to confirm the efficacy of this technique and to specify the target sites. METHODS AND RESULTS: Two hundred consecutive patients with drug-resistant common atrial flutter were studied. In the first 50 patients, target sites were localized using both anatomic landmarks and electrophysiologic parameters. The anatomic landmarks were area 1 between the tricuspid valve and inferior vena cava orifice; area 2 between the tricuspid valve and coronary sinus ostium; and area 3 between the inferior vena and coronary sinus. The electrophysiologic criterion was to ablate when there was an atrial electrogram occurring during the plateau phase (preceding F wave). The first targeted area was that giving the more stable catheter position. In the following 30 patients, we assessed the effect of RF energy application in a single line to area 1 in the first 10 patients, area 2 in the next 10, and area 3 in the last 10 patients. In the last 120 patients, RF energy was applied only in area 1 using repeated applications. RF energy of 12 to 30 W, or that achieving a temperature of 70 degrees C, was applied for 60 to 90 seconds at each site. The endpoint of the ablation procedure was interruption and noninducibility of common atrial flutter in the first 110 patients and additional isthmal block in 48 of the last 90 patients. Overall, atrial flutter was interrupted and rendered noninducible after a single session in 191 (95%) patients and could not be interrupted in 9 (4.5%) patients. The mean number of RF applications was 12 +/- 8. After a mean follow-up of 24 +/- 9 months, recurrences occurred in 31 (15.5%) patients, 26 of whom underwent a successful second or third session without further recurrences of atrial flutter. Atrial fibrillation not documented before the ablation was detected in 11 patients. On a retrospective analysis of the final successful site in the first group of 50 patients, the location was in area 1 in 39% of patients; area 2 in 36% of patients, and area 3 in 25% of patients. Atrial electrograms recorded at these sites showed a single spike pattern in 46% of patients, and double spike pattern (28%) or fractioned electrogram in 26% patients. When lines of RF lesions were placed at several sites, they produced a success rate of 70%, 40%, and 10% at areas 1, 2, and 3 respectively. In the last series of 120 patients, the procedure was successful in 119 patients: 92% of whom were successfully treated only by a linear lesion between the tricuspid annulus isthmus and the inferior vena cava, and the other 8% by additional applications near the coronary sinus ostium. No complications were observed. CONCLUSIONS: RF catheter ablation of atrial flutter can be done with a high success rate and is safe. The highest success rate is achieved with RF energy applied in the isthmus between the inferior vena cava orifice and the tricuspid valve. However, 15.5% of patients need multiple sessions to achieve success because of recurrence of flutter. Further follow-up is needed to evaluate the long-term effects of this procedure.

Adult↗

Suprascapular nerve block in chronic shoulder pain: are the radiologists better?

BACKGROUND: Suprascapular nerve block is a safe and effective treatment for chronic shoulder pain in arthritis, which can be performed either by direct imaging (CT guided) or in the clinic using anatomical landmarks to determine needle placement. OBJECTIVE: To compare a CT guided versus an anatomical landmark approach in a randomised, single blind trial examining the efficacy of suprascapular nerve block for shoulder pain in patients with degenerative joint/rotator cuff disease. METHODS: 67 patients with chronic shoulder pain from degenerative disease participated in the trial. 77 shoulders were randomised. The group randomised to receive the block through the anatomical landmark approach received a single suprascapular nerve block. Those in the CT guided group received an injection of methylprednisolone acetate and a smaller volume of bupivacaine around the suprascapular nerve. The patients were followed up for 12 weeks by a "blinded" observer and reviewed at weeks 1, 4, and 12 after the injection. RESULTS: Significant improvements were seen in all pain scores and disability in the shoulders receiving both types of nerve block, with no significant differences in the improvement in pain and disability between the two approaches at any time. Improvements in pain and disability scores were clinically and statistically significant. No significant adverse effects occurred in either group. Patient satisfaction scores for pain relief using either approach were high. CONCLUSION: The CT guided control and landmark approaches to performing suprascapular nerve blocks result in similar significant and prolonged pain and disability reductions; both approaches are safe.

Aged↗

The evaluation of high-speed screen/film combinations in cephalometric radiography.

Cephalometric radiographs of a tissue equivalent plastic encased dry skull, each made with eight different screen/film combinations, were compared for usefulness in making orthodontic analyses. The eight screen/film combinations chosen ranged in relative speed from 80 to 600. Only one grid cassette was used, and it was a Par speed screen/film combination. Ten orthodontists identified 13 selected anatomic landmarks and rated the adequacy of their radiographic images. The density of each cephalometric radiograph was analyzed for each anatomic landmark. The results showed a difference in density readings for the various landmarks visualized. The optical density preferences of the 13 anatomic landmarks ranged between 0.87 and 2.09. The study leads to the conclusion that cephalometric radiographs can be taken with screen/film combinations that provide maximum useful information with a minimum dose level to the patient.

Calcium Compounds↗

[Can a precise vesiculectomy be performed during radical prostatectomy?].

OBJECTIVE: To define the anatomical landmarks allowing precise vesiculectomy to be performed during radical prostatectomy for cancer. MATERIAL AND METHODS: 12 non-formalin-preserved anatomical subjects were dissected as during retropubic and perineal prostatectomy, with and without coloured latex vascular injection. RESULTS: Three anatomical landmarks were defined: 1) Denonvilliers' fascia; 2) vas deferens; 3) arteries supplying the seminal vesicles. CONCLUSIONS: These three anatomical landmarks ensure: complete resection, preservation of adjacent anatomical structures and elective haemostasis.

Aged↗

[Intraoperative and postoperative insertion control of anterior cruciate ligament-plasty. A radiologic measuring method (quadrant method)].

The best proximal insertion for an ACL graft is an anatomic insertion. The anatomic landmarks of this insertion area are well known, but it is sometimes difficult to find these anatomic landmarks during the operation. Thus, it is desirable to have an objective method to control the insertion. This study was undertaken because no description is available how you can localize the projection of the anatomic ALC insertion exactly in an X-ray picture. We dissected ten human cadaveric knees with intact ACLs. The most ventral, dorsal, distal and proximal borders of the insertion area were marked with 4 K-wires. The K-wires were shortened exactly on the bone border of the intercondylar space. Then the knees were X-rayed in a strictly lateral position. Thus, the shortened ends of the K-wires determined the projection of the ACL insertion in the X-ray picture. The center of this marked area was called point K. Then we determined 4 distances in the X-ray picture: distance t: the sagittal diameter of the lateral condyle, measured along the Blumensaat line distance h: the maximal height of the notch distance a: the distance between K and the dorsal border of the condyle, measured along t distance b: the distance between t and K, measured on a perpendicular line on t Distance a is a partial distance of t and distance b is a partial distance of h. Because of varying projection factors and varying knee sizes, absolute values of these distances are not helpful. This is the reason why we expressed a and b as a proportion of t and h. Distance a was measured 24.8% of distance t. Distance b was measured 28.5% of distance h. The maximal deviation of a and b was 2.2% and 2.5%. Therefore, you can say: In a strictly lateral X-ray picture the distance of K (midpoint of proximal ACL insertion) from the dorsal border of the condyle is 24.8% of the whole diameter of the condyle, and the distance of K from the roof of the notch is 28.5% of the notch-height. This method does not depend on the size of the knee and the distance between the X-ray unit and the knee. The only condition is that the X-ray of the knee must be strictly lateral. This method is easy to handle and is reproducible. It can be used intraoperatively if the surgeon is not sure about the right insertion or if the anatomic landmarks cannot be seen exactly. It can be used postoperatively for documentation of the right position of the substitute. It can be used to find out the possible reason for rupture of a transplant (insertion too ventral) before the revision operation.

Anterior Cruciate Ligament↗

Accuracy of computer navigation in ear, nose, throat surgery: the influence of matching strategy.

OBJECTIVE: To measure the effect of 4 different matching strategies on the accuracy of computer navigation on the face and within the nose and rhinopharynx. DESIGN: Survey. SETTING: Laboratory study. SUBJECTS: Six human cadavers studied within 24 hours of death. INTERVENTIONS: A commercially available navigation system with infrared optical tracking was used for computer navigation on the face and within the nose of the subjects after matching with external fiducials or with 3 different configurations of anatomical landmarks. Navigation errors were measured and correlated to matching strategies and compared through statistical analysis. RESULTS: Matching with external fiducials on the face results in smaller navigation error than matching with anatomical landmarks. The configuration of matching strategies with anatomical landmarks also significantly determines the accuracy of computer navigation, especially when different locations of accuracy measurement are considered. CONCLUSION: Statistically significant findings have shown that the choice of a matching strategy is a major factor in the accuracy of computer navigation for ear, nose, throat surgery. Arch Otolaryngol Head Neck Surg. 2000;126:1462-1466

Cadaver↗

Analysis of low-dose digital lateral cephalometric radiographs.

OBJECTIVE: To examine the effects of the dose reduction obtained with photostimulable phosphor computed radiography (CR) on the identification of cephalometric landmarks. METHODS: Dose reductions of 50% and 75% respectively were obtained by placing three storage phosphor image plates in the same cassette. Lateral cephalograms were exposed on ten patients. Seven observers identified 14 anatomical landmarks on the images. RESULTS: The location of anatomical landmarks on the lateral cephalograms was not effected by the decreased dose (P > 0.05). Interobserver variation was the major influence. CONCLUSION: A dose reduction of 75% does not effect the localization of anatomical landmarks in lateral cephalograms obtained with CR.

Adolescent↗

Morphologic parameters of normal swallowing events using single-shot fast spin echo dynamic MRI.

This study was designed to determine visible and measurable morphological parameters in normal swallowing using dynamic MRI with single-shot fast spin echo (SSFSE), as a preliminary study in view of noninvasive MRI swallowing evaluation in patients with dysphagia. Seven healthy volunteers aged 24-40 underwent dynamic MRI with SSFSE, with a 1.5-T unit, using a head and neck antenna. Patients repeated dry swallow, water swallow, marshmallow swallow, cake swallow, and cookie chewing for a total of five series, with 15 acquisitions per series at a rate of 700 ms per acquisition. A checklist of swallowing events and anatomic landmarks was used to determine which anatomic landmarks are always visible, which phases or swallowing movements are always visible, and which landmarks can be used to measure oral and pharyngeal motion in swallowing. The oral preparatory, oral, and oropharyngeal phases of deglutition were visible in all cases. No aspiration, reflux, or abnormal residue was observed. Spatial resolution allowed for anatomical measurements of laryngeal elevation, oropharyngeal diameter, and tongue base and velum displacement in all cases. SSFSE dynamic MRI is pertinent for evaluation of the anatomical and physiological characteristics of swallow. The temporal parameters, however, cannot be studied using this technique. Motion artifacts preclude its use in the study of mastication. It remains complementary to videofluoroscopy and other techniques in swallow evaluation.

Adult↗

Quantitative anatomic evaluation of cervical lateral mass fixation with a comparison of the Roy-Camille and the Magerl screw techniques.

STUDY DESIGN: An anatomic and computed tomography (CT) study of the Roy-Camille and the Magerl techniques with quantitative comparison of the safety zones of the two surgical techniques. OBJECT: The purpose of this study was to compare quantitatively the safety zones of the Roy-Camille and the Magerl techniques as a function of the vertebral level from C3-C6. SUMMARY OF BACKGROUND DATA: The two most popular techniques for lateral mass screws are the Roy-Camille and the Magerl technique. Nerve roots, vertebral artery, facet joints, and the spinal cord are at risk during the placement of lateral mass screws. Several anatomic studies are reported, but there is no comparative and quantitative evaluation. The influence of the vertebral level was never reported. METHODS: Lateral mass screws were first implanted on four cervical spines according to the two surgical techniques. Screws were then extracted and their cavities filled with a blue casting medium. To determine the precise limits of each safety zone in the sagittal plane, the specimens were sectioned according to the sagittal angulation of the two screwing techniques. The correlations between the anatomic landmarks on the specimen and the anatomic landmarks on the CT scan were established. One hundred and sixty lateral mass screws were then implanted in 20 cervical spines from C3-C6. A CT was done before and after placing lateral mass screws. On the morphologic CT scan, we measured the sagittal safety angle (SSA) for each surgical technique and also performed a morphometry of lateral masses. On the control CT scan, we analyzed screws placement in relation to the sagittal safety zone. RESULTS: The mean SSA was 15.8 +/- 6.3 degrees for the Roy-Camille technique and 18.7 +/- 3.8 degrees for the Magerl technique, P < 0.005. With respect to the vertebral level, the Roy-Camille safety zone decreased from C3-C6 with a greater angulation at C3-C4 (20.4 +/- 4.7 degrees ) than at C5-C6 (11.6 +/- 4.3 degrees ), P < 0.001. Such variations were not observed for the Magerl technique, the SSA of which was 19.4 +/- 3.6 degrees at C5-C6 and 17.9 +/- 4 degrees at C3-C4, P < 0.01. Lateral masses became more elongated and thinner at the lower segment of the cervical spine with a C3-C4 height/thickness ratio = 1.1 +/- 0.3 and a C5-C6 height/thickness ratio = 1.3 +/- 0.2, P < 0.005. Roy-Camille screws (19%) were found out of the safety zone at C3-C4 whereas 37.5% were found outside at C5-C6, P < 0.05. We observed opposite results for Magerl screws with 38% screws out of the safety zone at C3-C4 and only 17.5% outside at C5-C6, P < 0.05. CONCLUSION: The Roy-Camille technique demonstrated a progressive decrease of its safety zone from C3-C6. At C5 and C6 there is a great probability to have a transarticular screw with a Roy-Camille screw. A similar variation was not observed for the Magerl technique. These anatomic results seem to be in relation with the morphologic variability of lateral masses from C3-C6 as demonstrated by an increase of the height/thickness ratio at the lower part of the cervical spine. According to these anatomic considerations and previously published biomechanical data, Roy-Camille technique appears to be the best option at C3 and C4. On the opposite at C5 and C6, the choice is more difficult considering that there is no biomechanical difference between the two techniques and that the Magerl technique is safer but a more demanding procedure.

Biomechanical Phenomena↗

New landmarks for the anterior approach to the sciatic nerve block: imaging and clinical study.

UNLABELLED: In this study, we assessed the reliability of the inguinal crease and femoral artery as anatomic landmarks for the anterior approach to the sciatic nerve and determined the optimal position of the leg during this approach. An imaging study was conducted before the clinical study. The sciatic nerve was located twice in 20 patients undergoing ankle or foot surgery, once with the leg in the neutral position and once with the leg in the externally rotated position. The patient was lying supine. A 22-gauge, 150-mm insulated b-beveled needle connected to a nerve stimulator was inserted 2.5 cm distal to the inguinal crease and 2.5 cm medial to the femoral artery and was directed posteriorly and laterally with a 10 degrees -15 degrees angle relative to the vertical plane. The sciatic nerve was located in all patients at a depth of 10.6 +/- 1.8 cm when the leg was in the neutral position and 10.4 +/- 1.5 cm when the leg was in the externally rotated position (not significant). In the neutral position and in the externally rotated position, the time needed to identify anatomic landmarks was 28 +/- 15 s and 26 +/- 14 s, respectively (not significant), and the time needed to locate the sciatic nerve was 79 +/- 53 s and 46 +/- 25 s (P < 0.006), respectively. We conclude that the inguinal crease and femoral artery are reliable and effective anatomic landmarks for the anterior approach to the sciatic nerve and that the optimal position of the leg is the externally rotated position. IMPLICATIONS: This new anterior approach to the sciatic nerve using the inguinal crease and femoral artery as landmarks is an easy and reliable technique.

Adolescent↗