PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Biodegradable Delivery Systems”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Pharmacokinetic quantitation of naltrexone controlled release from a copolymer delivery system.

Naltrexone release rates from a controlled release delivery system have been quantitated over a time period greater than one month in the monkey. The method requires calibration of the pharmacokinetic parameters of each monkey utilizing an intravenous bolus dose and assay of unchanged naltrexone levels in plasma as a function of time after dosing. Also required are periodic plasma levels of unchanged naltrexone obtained subsequent to administration of the delivery system. Release rates are then calculated as well as the total amount released. Application of the methodology to a biodegradable copolymer naltrexone delivery system in three monkeys showed an initial release rate of 3-8% of the dose per day over the first 3-5 days followed by a slow, rather constant release rate of 1-3% per day from day 5 to the time of the last measurable plasma sample (36-43 days). Comparison of alternative calculation methods using both experimental and simulated plasma naltrexone data verified the accuracy of the release rate calculations. The sum of the calculated total amount of naltrexone released plus the assayed amount remaining in the delivery system after removal from the animal accounted for 91-94% of the administered dose in the two monkeys in which complete data were obtained.

Animals↗

Acute histopathological response to a new biodegradable polypeptidic polymer for implantable drug delivery system.

This article deals with the in vivo evaluation of a new class of synthetic polypeptides, the poly[(tert-butyloxycarbonylmethyl) glutamates], POMEG, as an injectable or implantable drug delivery system. Three different polymers, varying in their degree of esterification, were extruded either with or without progesterone, and finally implanted in rats up to 14 days. Histologic evaluation of the implant sites show evidence of the good biocompatibility of these polymers. In addition, the description of their in vivo behavior, based on microscopic observation of the implanted POMEG rods, enables one to appreciate their potential as a drug delivery system for short- or long-term therapy.

Animals↗

Biodegradable injectable in situ forming drug delivery systems.

The ability to inject a drug incorporated into a polymer to a localized site and have the polymer form a semi-solid drug depot has a number of advantages. Among these advantages is ease of application and localized, prolonged drug delivery. For these reasons a large number of in situ setting polymeric delivery systems have been developed and investigated for use in delivering a wide variety of drugs. In this article we introduce the various strategies that have been used to prepare in situ setting systems, and outline their advantages and disadvantages as localized drug delivery systems.

Animals↗

Preparation and characterization of a biodegradable drug targeting system for anticancer drug delivery: microsphere-antibody conjugate.

Targeted delivery of anticancer drugs is one of the most actively pursued goals in anticancer chemotherapy. A major disadvantage of anticancer drugs is their lack of selectivity for tumour tissue, which causes severe side effects and results in low cure rates. Any strategy by which a cytotoxic drug is targeted to the tumour, thus increasing the therapeutic index of the drug, is a way of improving cancer chemotherapy and minimizing systematic toxicity. This study covers the preparation of the gelatin microsphere (GM)-anti-bovine serum albumin (anti-BSA) conjugate for the development of a drug targeting approach for anticancer drug delivery. Microspheres of 5% (w/v) gelatin content were prepared by crosslinking with glutaraldehyde (GTA) at 0.05 and 0.50% (v/v) concentration. Microspheres were in the size range of 71-141?microm. The suitability of these microspheres as drug carriers for anticancer drug delivery was investigated in vitro by studying the release profiles of loaded methotrexate (MTX) and 5-fluorouracil (5-FU) and the cytotoxicities on cancer cell lines. The in vitro MTX release profiles (approximately 22-46% released in 24 h depending on the amount of GTA used) were much slower compared to 5-FU (approximately 42-91% released in 24 h). Both drugs demonstrated an initial fast release, which was followed by gradual, sustained drug release. The MTT cytotoxicity test results of GMs loaded with 5-FU and MTX showed approximately 54-70% and approximately 52-67% cytotoxicities in 4 days. In general, incorporation of MTX and 5-FU in microspheres enhanced the cytotoxic effect in a more prolonged manner compared to the free drugs. Gelatin micospheres were chemically conjugated to anti-BSA and the antigen-antibody activities were studied by immunofluorescence. Results indicated approximately 80% binding with conjugated anti-BSA and BSA-FITC. Based on their low cytotoxicity and the high antigen binding efficiencies, anti-BSA conjugated gelatin microspheres could be suitable targeted drug carrier systems for selective and long-term delivery of anticancer drugs to a specific body compartment (i.e. bladder cancer).

Antibodies↗

Biodegradable block copolymers as injectable drug-delivery systems.

Polymers that display a physicochemical response to stimuli are widely explored as potential drug-delivery systems. Stimuli studied to date include chemical substances and changes in temperature, pH and electric field. Homopolymers or copolymers of N-isopropylacrylamide and poly(ethylene oxide)-poly(propylene oxide)-poly(ethylene oxide) (known as poloxamers) are typical examples of thermosensitive polymers, but their use in drug delivery is problematic because they are toxic and non-biodegradable. Biodegradable polymers used for drug delivery to date have mostly been in the form of injectable microspheres or implant systems, which require complicated fabrication processes using organic solvents. Such systems have the disadvantage that the use of organic solvents can cause denaturation when protein drugs are to be encapsulated. Furthermore, the solid form requires surgical insertion, which often results in tissue irritation and damage. Here we report the synthesis of a thermosensitive, biodegradable hydrogel consisting of blocks of poly(ethylene oxide) and poly(L-lactic acid). Aqueous solutions of these copolymers exhibit temperature-dependent reversible gel-sol transitions. The hydrogel can be loaded with bioactive molecules in an aqueous phase at an elevated temperature (around 45 degrees C), where they form a sol. In this form, the polymer is injectable. On subcutaneous injection and subsequent rapid cooling to body temperature, the loaded copolymer forms a gel that can act as a sustained-release matrix for drugs.

Animals↗

Biodegradable and complexed microspheres used for sustained delivery and activity protection of SOD.

To develop a new protein delivery system for superoxide dismutase (SOD), biodegradable materials like poly(DL-lactide-co-glycolide) (PLGA), alginate, and chitosan were used for preparing PLGA microspheres and alginate-chitosan microspheres, which were used for encapsulating protein. Alginate-chitosan microspheres showed much higher entrapment efficiency (91.08% +/- 1.28%) than that of PLGA microspheres (36.42% +/- 1.81%). In vitro release study showed that SOD presented a sustained release character in the preparation of these biodegradable materials. After 15 days, 43.72% +/- 0.43% of protein was released from alginate-chitosan microspheres, while there was 62.96% +/- 3.95% of protein release from PLGA microspheres. However, alginate-chitosan demonstrated that it was a better material to control the burst release of protein from microspheres. Furthermore, SOD activity in microspheres was evaluated, and the results showed that microspheres protected the activity of protein to some extent. Finally, PLGA-alginate-chitosan complex microspheres were constructed and the release character in vitro demonstrated that this preparation could not only prolong the release of drug but also decrease the burst release.

Alginates↗

Intraocular dexamethasone delivery system for corneal transplantation in an animal model.

PURPOSE: To assess the efficacy of a new intraocular biodegradable polymer dexamethasone drug delivery system (DEX DDS) in a high-risk corneal transplantation model. METHODS: Lewis rats that received orthotopic corneal transplants (Balb/c mice donors) were divided into three groups (six rats in each); group 1 received no treatment and served as controls, group 2 was treated with 0.1% betamethasone eyedrops three times daily for 6 weeks, and group 3 received DEX DDS in the anterior chamber at the time of transplantation. RESULTS: All grafts in the untreated control group were rejected within 8 days. In the betamethasone eyedrop group, five eyes (83%) were rejected during the 8-week study period. None of the grafts in the DEX DDS group was rejected. The administration of DEX DDS significantly prolonged the survival rate of the corneal grafts (p < 0.001, log-rank test). CONCLUSION: DEX DDS is effective in suppressing graft rejection in high-risk corneal transplantation.

Absorbable Implants↗

Biodegradable poly(DL-lactic acid) formulations in a calcitonin delivery system.

A synthetic analogue of eel calcitonin, [Asu1, 7]-ECT, was incorporated into biodegradable poly(DL-lactic acids) with number-average molecular weights (Mn) of 1400-4400 by the melt-pressing technique. The in vitro release of drug from a parabolically degradable poly(DL-lactic acid) with Mn = 1400 showed an initial burst release and completed the release in 3 d from the start of the test. The drug release from a Mn = 4400 polymer with an S-type degradation pattern was kept at 14 +/- 5 units/d for an experimental period of 24 d.

Amino Acid Sequence↗

Biodegradable injectable in situ depot-forming drug delivery systems.

The scope of drug-delivery systems has expanded significantly in recent years providing new ways to deliver life saving therapeutics to patients. The development of new injectable drug-delivery systems has provided new vistas and opened up unexplored horizons in the field of science, particularly in controlled drug delivery since these systems possess unique advantages over traditional ones, which include ease of application, and localized and prolonged drug delivery. In the past few years, an increasing number of such systems has been reported in the literature for various biomedical applications, including drug delivery, cell encapsulation, and tissue repair. These are injectable fluids that can be introduced into the body in a minimally invasive manner prior to solidifying or gelling within the desired site. For this purpose both natural (chitosan, alginates) as well as synthetic polymers (PEGylated polyesters, ricinoleic acid-based polymers) have been utilized. These systems have been explored widely for the delivery of various therapeutic agents ranging for anti-neoplastic agents like paclitaxel to proteins and peptides such as insulin, almost covering every segment of the pharmaceutical field. This manuscript focuses on the recent advancements in the area of in situ forming biodegradable polymeric drug-delivery systems.

Antineoplastic Agents, Phytogenic↗

Biodegradable polymer microspheres as vaccine adjuvants and delivery systems.

Though vaccination has been the most cost-effective way of controlling infectious diseases, the logistics of delivering at least two to three doses of conventional vaccines for primary immunization to achieve protection are difficult and compliance is frequently inadequate, particularly in developing countries. In recent years biodegradable polymer microspheres have received much attention for the purposes of controlled release of antigens, (i) to reduce the number of doses needed for primary immunization to as few as a single dose and (ii) to target an antigen to microfold cells on mucosal surfaces after oral administration or to antigen-presenting cells after parenteral inoculations. A variety of vaccine antigens have been encapsulated in microspheres usually composed of poly (lactic/glycolic) acid (PLGA). Based on the size of the microspheres, molecular weight of polymer and ratio of lactic to glycolic acid in the polymer, the antigen may be targeted to various cells of the immune system or it may form a depot at the site of injection, allowing the slow release of the antigen for extended periods. Additionally, another adjuvant may be incorporated inside microspheres together with the antigen, further enhancing or modulating the immune response to the desired type. The major problems in developing controlled-release vaccines include instability of vaccine antigens during micro-encapsulation, storage and subsequent hydration. We encapsulated tetanus toxoid (TT) and Haemophilus influenzae type b capsular polysaccharide conjugated to TT (Hib-T) inside PLGA microspheres and evaluated the antibody levels in mice. A single injection of these micro-encapsulated vaccines elicited high antibody levels which persisted for several months. The antibody levels were similar or superior to those elicited by conventional formulations of AIPO4-adsorbed TT or soluble Hib-T conjugate vaccine.

Adjuvants, Immunologic↗

FK506 in a biodegradable glycolide-co-clatide-co-caprolactone polymer for prolongation of corneal allograft survival.

PURPOSE: FK506 has been extensively used in preventing immune rejection for human organ transplantation. This study aimed to evaluate the effects of a biodegradable FK506 drug delivery system (DDS) implanted into anterior chamber for the prolongation of corneal allograft survival in high-risk keratoplasty. METHODS: Biodegradable glycolide-co-clatide-co-caprolactone polymer (PGLC) was used as drug carrier to be incorporated with 0.5 mg of FK506 powder. The drug release from the FK506-PGLC DDS was evaluated in vitro and in vivo. The FK506-PGLC DDS was implanted into the anterior chamber of 12 high-risk keratoplasty rabbits. The graft survival time and clinical features of the FK506-PGLC DDS group were compared with the untreated, PGLC DDS, cyclosporin A-PGLC DDS, and 0.5% FK506 drops groups. The histopathological examination was performed to evaluate the safety of the FK506-PGLC DDS. RESULTS: The mean graft survival time was longest (> 180 days) in the FK506-PGLC DDS group. In vivo, the FK506 concentration in aqueous humor peaked on day 28 (17.9 +/- 2.3 ng/ml) and kept a sustained release for at least 168 days. No adverse reactions were observed in the FK506-PGLC DDS group. CONCLUSIONS: Biodegradable FK506-PGLC DDS implanted into anterior chamber can effectively prevent immune rejection in high-risk keratoplasty model, presenting a promising approach for the prolongation of corneal allograft survival.

Absorbable Implants↗

Bioresorbable nanofiber-based systems for wound healing and drug delivery: optimization of fabrication parameters.

Wound healing is a complex process that often requires treatment with antibiotics. This article reports the initial development of a biodegradable polymeric nanofiber-based antibiotic delivery system. The functions of such a system would be (a) to serve as a biodegradable gauze, and (b) to serve as an antibiotic delivery system. The polymer used in this study was poly(lactide-co-glycolide) (PLAGA), and nanofibers of PLAGA were fabricated with the use of the electrospinning process. The objective of this study was to determine the effect of fabrication parameters: orifice diameter (needle gauge), polymer solution concentration, and voltage per unit length, on the morphology and diameter of electrospun nanofibers. The needle gauges studied were 16 (1.19 mm), 18 (0.84 mm), and 20 (0.58 mm), and the range of polymer solution concentration studied was from 0.10 g/mL to 0.30 g/mL. The effect of voltage was determined by varying the voltage per unit electrospinning distance, and the range studied was from 0.375 kV/cm to 1.5 kV/cm. In addition, the mass per unit area of the electrospun nanofibers as a function of time was determined and the feasibility of antibiotic (cefazolin) loading into the nanofibers was also studied. The results indicate that the diameter of nanofibers decreased with an increase in needle gauge (decrease in orifice diameter), and increased with an increase in the concentration of the polymer solution. The voltage study demonstrated that the average diameter of the nanofibers decreased with an increase in voltage. However, the effect of voltage on fiber diameter was less pronounced as compared to polymer solution concentration. The results of the areal density study indicated that the mass per unit area of the electrospun nanofibers increased linearly with time. Feasibility of drug incorporation into the nanofibers was demonstrated with the use of cefazolin, a broad-spectrum antibiotic. Overall, these studies demonstrated that PLAGA nanofibers can be tailored to desired diameters through modifications in processing parameters, and that antibiotics such as cefazolin can be incorporated into these nanofibers. Therefore, PLAGA nanofibers show potential as antibiotic delivery systems for the treatment of wounds.

Anti-Bacterial Agents↗

Synthesis and self-association behavior of biodegradable amphiphilic poly[bis(ethyl glycinat-N-yl)phosphazene]- poly(ethylene oxide) block copolymers.

Amphiphilic diblock copolymers with varying compositions of hydrophilic poly(ethylene oxide) (PEO) and hydrophobic poly[bis(ethyl glycinat-N-yl)phosphazene] (PNgly) were synthesized via the controlled cationic-induced polymerization of a phosphoranimine (Cl(3)P=NSiMe(3)) at ambient temperature using a PEO-phosphoranimine macroinitiator. The aqueous-phase transition behavior of PEO-PNgly-3 (M(n) = 10,000) and micelle formation of both PEO-PNgly-3 and PEO-PNgly-4 (M(n) = 8,500) were investigated using fluorescence techniques and dynamic light scattering. The critical micelle concentrations (cmc's) of PEO-PNgly-3 and PEO-PNgly-4 were determined to be 3 and 12 mg/L with the mean diameters of micelles being 120 and 130 nm, respectively. The hydrolytic degradation of these diblock copolymers was also studied in solution. These studies coupled with the biodegradability of the poly[bis(ethyl glycinat-N-yl)phosphazene] block to give benign products make PEO-PNgly copolymers well-suited for a wide variety of biomedical applications including novel biodegradable drug-delivery systems.

Biocompatible Materials↗

[Development of polymeric nanoparticles-based vaccine].

Traditional vaccines are mainly composed of attenuated or heat-inactivated viruses. These vaccines often generate many unwanted side effects. Subunit protein and peptide vaccines are generally very safe vaccines with well-defined components. However, proteins and peptides are often poorly immunogenic and thus require the use of adjuvants to induce adequate immunity. Therefore, particulate adjuvants have been widely investigated in vaccine delivery systems. In particular, polymeric nanoparticles with entrapped antigens represent an exciting approach to control the release of vaccine antigens and optimize the desired immune response via selective targeting of antigen to professional antigen presenting cells. It is expected that biodegradable polymeric nanoparticles have great potential as carriers for systemic and mucosal vaccine delivery systems.

Antigens↗

A microfabrication method of a biodegradable polymer chip for a controlled release system.

A simple microfabrication method for a controlled-release drug-delivery system has been designed using biodegradable polymeric microchips. Microholes were made in a poly(L-lactic acid) plate and dyes were cast in each well. After drying, the wells were sealed with polymers having different biodegradation rates using a mold that had hollows corresponding to the wells. The polymers were prepared by mixing polylactides with the co-polymers. The sealing was confirmed by ultrasonication. The plate was incubated in phosphate-buffered saline and the dye released from the plate as the degradation proceeded was detected spectrophotometrically. The higher the degradation rate of the polymer sealing, the faster the sealed dye was released. This biodegradable biochip is useful for the design of controlled-release drug-delivery systems.

Biocompatible Materials↗

Reduced adhesion of blood cells to biodegradable polymers by introducing phosphorylcholine moieties.

Aliphatic polyesters are believed to be good biocompatible polymers for tissue engineering because of their biodegradability and nontoxicity of the degradated products. However, it is necessary to reduce the nonspecific protein adsorption for the application of biodegradable polymers to drug delivery systems or antiadhesive membranes. We hypothesized that novel biodegradable polymers could be synthesized by introducing phosphorylcholine moieties into aliphatic polyesters. The L-lactide was polymerized in the presence of L-alpha-glycelophosphorylcholine (LGPC) using stannous octate as the catalyst. The molecular weight and crystallinity of poly(L-lactide) (PLLA)-based phospholipid polymers (PLLA-PC) decreased with an increase in the composition of the LGPC unit in the PLLA-PC. The hydrolysis of the PLLA-PC was evaluated by soaking the polymer membranes in a phosphate buffer solution. The rate of weight loss was increased with increasing the LGPC units in PLLA-PC. The surface analysis of the membranes using an X-ray photoelectron microscope showed the composition of phosphorylcoline groups on the surface. The amount of adsorbed protein and adherent blood cell on the polymer surface was decreased with introducing LGPC unit. PLLA-PC is a promising biodegradable polymer having blood compatibility and antiadhesive property.

Adsorption↗

Tetracycline-HCl-loaded poly(DL-lactide-co-glycolide) microspheres prepared by a spray drying technique: influence of gamma-irradiation on radical formation and polymer degradation.

Tetracycline-HCl (TCH)-loaded microspheres were prepared from poly(lactide-co-glycolide) (PLGA) by spray drying. The drug was incorporated in the polymer matrix either in solid state or as w/o emulsion. The spin probe 4-hydroxy-2,2,6, 6-tetramethyl-piperidine-1-oxyl (TEMPOL) and the spin trap tert-butyl-phenyl-nitrone (PBN) were co-encapsulated into the TCH-loaded and placebo particles. We investigated the effects of gamma-irradiation on the formation of free radicals in polymer and drug and the mechanism of chain scission after sterilization. Gamma-Irradiation was performed at 26.9 and 54.9 kGy using a 60Co source. The microspheres were characterized especially with respect to the formation of radicals and in vitro polymer degradation. Electron paramagnetic resonance (EPR) spectroscopy, gel permeation chromatography (GPC), differential scanning calorimetry (DSC), high-performance liquid chromatography (HPLC), gas chromatography-mass spectroscopy (GC-MS), and scanning electron microscopy (SEM) were used for characterization of the microspheres. Using EPR spectroscopy, we successfully detected gamma-irradiation induced free radicals within the TCH-loaded microspheres, while unloaded PLGA did not contain radicals under the same conditions. The relatively low glass transition temperature of the poly(dl-lactide-co-glycolide) (37-39 degrees C) seems to favor subsequent reactions of free radicals due to the high mobility of the polymeric chains. Because of the high melting point of TCH (214 degrees C), the radicals can only be stabilized in drug loaded microspheres. In order to determine the mechanism of polymer degradation after exposure to gamma-rays, the spin trap PBN and the spin probe TEMPOL were encapsulated in the microspheres. gamma-Irradiation of microspheres containing PBN resulted in the formation of a lipophilic spin adduct, indicating that a polymeric radical was generated by random chain scission. Polymer degradation by an unzipping mechanism would have produced hydrophilic spin adducts of PBN and monomeric radicals of lactic or glycolic acid. These degradation products were not detected by EPR. This result is confirmed by the observation that possible diamagnetic reaction products of low molecular weight, consisting of TEMPOL and lactide or glycolide monomers, could not be detected by GC-MS. While an irradiation dose-dependent decrease in molecular weight of PLGA could be verified in agreement with the literature, TCH content of the microspheres was not affected by the exposure to gamma-rays. It can be concluded that EPR spectroscopy in combination with GPC, DSC, and HPLC allows a detailed characterization of the impact of gamma-sterilization on biodegradable parenteral drug delivery systems.

Anti-Bacterial Agents↗

Controlled biodegradability of polymers--a key to drug delivery systems.

By combining oligopeptide sequences with synthetic polymeric chains, carriers of drug models can be prepared. The drug model (p-nitroaniline) is cleaved from the carrier in the lysosomal compartment of the cell. By changing the length and structure of the oligopeptide sequence, it is possible to regulate the rate of cleavage of drug model by individual thiol proteinases (cathepsins B, H and L) which are the most important as regards cleavage of the substrates studied. By connecting synthetic polymeric chains via oligopeptide bridges, it is possible to regulate the molecular weight as well as the biodegradability of the carrier molecule. Molecular weight also influences other biological properties, e.g., elimination from the organism, rate of pinocytic uptake and biological activity. Homopolymer of N-(2-hydroxypropyl)methacrylamide (HPMA) is nonimmunogenic in rats. Attachment of oligopeptide side chains gives rise to a macromolecule possessing immunogenic activity. The degree of antibody response depends on the detailed structure of the copolymer.

Animals↗