PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “DENTURE BASES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Factors that affect the rheologic properties of acrylic resin denture base materials.

The rheologic characteristics of different formulations of acrylic resin denture base materials are presented in this study. This is of practical significance in selecting resins with optimum rheologic properties for denture base construction. The materials are characterized in respect to their constituents, mean powder particle size and distribution, molecular weight averages and distributions, and glass transition temperature. A comparison of the polymers indicates that smaller particles saturate with monomer more readily, and this results in a higher viscosity. A higher viscosity for higher molecular weight and lower viscosity for lower molecular weight have been observed. Increasing the percentage of copolymerization increases the viscosity. No correlation has been found between the rheologic properties of denture base polymers and the powder glass transition temperature.

Acrylic Resins↗

Adhesion testing of a denture base resin with 5 casting alloys.

PURPOSE: This study compared denture base resin shear bond strengths to silicoated Au-Pd, Au-Pd-Ag, Au-Ag-Pd-Cu, high-Pd, and Ni-Cr-Be alloys used to fabricate frameworks for hybrid implant prostheses. Microleakage between alloy and resin was also compared among groups after specimen fracture. MATERIALS AND METHODS: Twelve cylindrical specimens were cast for each alloy. Each specimen was made from a ring-shaped pattern (diameter [d] = 12 mm and height = 4 mm) and machined to achieve uniform hollow centers (d = 6.5 mm). Castings were abraded with 250-micron aluminum oxide and ultrasonically cleaned in distilled water before silicoating. Denture base resin was processed to the internal surfaces of the silicoated specimens. All specimens were thermocycled (1,000 cycles) between 4 degrees C and 50 degrees C, and placed in basic fuchsin dye for a week. A punch (d = 3.8 mm) driven at a cross-head speed of 0.5 mm/min was used to push out the resin specimens. The force required to cause failure was converted to the nominal shear bond strength for each specimen, and mean shear bond strengths for the 5 groups of specimens (N = 12) were compared using one-way analysis of variance and the Tukey-Kramer HSD multiple range test (alpha = 0.05). Six of the 12 debonded resin samples for each alloy were selected at random and evaluated for dye penetration. Using an 80-square grid, the percentage of dye penetration was evaluated with an optical microscope (x25) to determine the percentage of grid area penetrated by the dye. One-way analysis of variance was used to compare the degree of microleakage among groups. RESULTS: The mean resin-alloy shear bond strengths for the Au-Pd (9.6 +/- 3.7 MPa) and Au-Ag-Pd-Cu (9.2 +/- 1.5 MPa) alloys were significantly greater than mean resin-alloy shear bond strength for the Au-Pd-Ag alloy (5.6 +/- 1.9 MPa). No other significant differences in resin-alloy shear bond strengths were noted among the alloy groups. No significant differences were noted for dye penetration into the resin specimens bonded to any of the 5 alloys. The mean grid area penetrated by the dye was 25% when results for the alloys were pooled. CONCLUSIONS: Alloy type influences the shear bond strength of a denture base resin to silicoated alloys, but no difference in bond strength was found between Au-Pd, Au-Ag-Pd-Cu, high-Pd, and Ni-Cr-Be alloys. In addition, under the conditions of this study, all groups showed a similar degree of microleakage, which penetrated approximately 25% of the bonded specimen surface area.

Air Abrasion, Dental↗

Effect of tissue conditioners on the dynamic viscoelastic properties of a heat-polymerized denture base.

STATEMENT OF PROBLEM: Little is known about the influence of tissue conditioners on physical property alteration of denture base resins. PURPOSE: This study evaluated the influence of a variety of commercial tissue conditioners on alteration of viscoelastic properties of a heat-polymerized denture base acrylic resin. MATERIAL AND METHODS: Four tissue conditioners and 1 heat-polymerized denture base acrylic resin were used. In one experiment, acrylic resin specimens (1.0-mm thick) were immersed in the liquid component of tissue conditioners for 36 hours. In another experiment, tissue conditioners were applied to acrylic resin specimens (0.5-mm and 1.0-mm thick) in a 2-mm layer; the specimens then were immersed in distilled water for 1 week. Control specimens for both groups had no lining and were immersed in distilled water for 36 hours and 1 week, respectively. Dynamic viscoelastic properties of the acrylic resin specimens were measured at 37 degrees C with an automatic viscoelastometer. Tensile storage modulus (E'), tensile loss modulus (E"), and loss tangent (tan delta) were determined at 1 Hz. These parameters were compared with analysis of variance and the Dunnett test at a predetermined significance level of.05. All statistical comparisons were made with reference to the control group and not to each other. RESULTS: Only the liquid of Hydro-Cast significantly reduced E' and increased tan delta of the acrylic resin (P<.05). Acrylic resin specimens 0.5-mm thick and lined with tissue conditioners tended to have lower E' and higher tan delta than the control. However, only Hydro-Cast and SR-Ivoseal significantly decreased E', and only Hydro-Cast raised tan delta of the acrylic resin (P<.05). No significant difference was found among the E" values. The tissue conditioners did not affect E', E", or tan delta of acrylic resin specimens 1.0-mm thick. CONCLUSION: Within the limitations of this study, some tissue conditioners significantly plasticized the denture base acrylic resin 0.5-mm thick. However, when the acrylic resin was 1.0-mm thick, no plasticization by the tissue conditioners was noted.

Acrylic Resins↗

Effect of surface treatment on the bonding of an autopolymerizing soft denture liner to a denture base resin.

PURPOSE: This in vitro study evaluated the effects of surface treatments and thermocycling on the bonding of autopolymerizing silicone soft denture liner (Sofreliner) to denture base resin. MATERIALS AND METHODS: The bonding surfaces of denture base cylinders were polished with 600-grit silicon carbide paper and pretreated with applications of Sofreliner Primer, Sofreliner Primer after air abrasion, Reline Primer, or Reline Primer after air abrasion. Failure loads and elongation at failure were measured after subjecting specimens to 0, 10,000, 20,000, and 30,000 thermocycles. Failure modes were assessed for all specimens. Seven specimens were fabricated for each of 16 groups, including four pretreatments and four thermocycle groups. RESULTS: Failure loads of the Sofreliner Primer group were significantly higher than those of the air-abrasion group up to 20,000 thermocycles; both groups showed cohesive failures of the soft denture liner. Failure loads of the Reline Primer group were significantly higher than with Reline Primer after air abrasion up to 10,000 thermocycles. Failure mode after 10,000 thermocycles was cohesive for the Reline Primer group and mixed cohesive/adhesive for Reline Primer after air abrasion. Failure loads of the Sofreliner Primer group were significantly higher than those of the Reline Primer group at each thermocycling interval. Elongation values decreased after 10,000 thermocycles for all groups. CONCLUSION: Air abrasion on the denture base resin surface was not effective in enhancing failure load. Cyclic thermal stress is one factor degrading the bond between soft denture liner and acrylic resin denture base.

Acrylic Resins↗

Tensile strength and water absorption of alumina filled poly (methyl methacrylate) denture base material.

The aim of this study was to evaluate the tensile properties and water absorption of denture base material prepared from high molecular weight poly methyl methacrylate (PMMA) and alumina (Al2O3) as particulate filler. Specimens for mechanical testing were prepared by adding composite powder to the monomer followed by hand mixing as in dental laboratory procedure. The tensile strength of the prepared denture base material was slightly higher than commercial denture base material, while the water absorption was almost the same for all formulation of denture base materials.

Absorption↗

In vitro adherence of microorganisms to denture base resin with different surface texture.

We examined the effects of various denture base resin surface textures on the adherence of microorganisms. S. sanguis and B. gingivalis adhered in greater amounts to the denture base resin than the other microorganisms tested. As to bacterial adherence according to polishing state, S. oralis, B. gingivalis C-101, and B. intermedius C-001 more adhered to the No. 400 paper-polished surface than to the buff-polished and smoothening-treated surfaces. S. sanguis less adhered to the smoothening-treated surface. S. mitis and C. albicans, on the other hand, more adhered to the smoothening-treated surface. For the other microorganisms tested, no relationship was observed between surface texture and bacterial adherence. The fall-off test revealed no remarkable differences in the fall-off of S. sanguis and B. gingivalis C-101 by the types of surface treatment. However, the fall-off of C. albicans was poorest from the No. 400 paper-polished surface. These results indicate that smoothening the denture base surface is important for denture plaque control.

Bacterial Adhesion↗

Histopathological changes in the tissues under a denture base in experimental osteoporosis with a non-pressure covering or bearing continuous pressure.

In this study, the experimental denture base on the hard palate of the molar region of osteoporotic rats was designed to cover without any mechanical pressure or to load continuous pressure (0.5, 1.5 or 3.4 kPa). Experimental osteoporosis was induced by ovariectomy and feeding on a low calcium diet. Histopathological changes induced by non-pressure covering or continuous pressure in the tissues under the experimental denture bases were examined. Regarding the histological changes induced by continuous pressure, this was evaluated in relation to the time course of the intensity of the continuous pressure. In the tissues under the denture base in osteoporotic condition with non-pressure covering, no histopathological changes caused by non-pressure covering were observed except for a transient slight proliferative reaction in the epithelial ridge. The following histopathological changes were observed in the tissues under the denture base in the osteoporotic condition bearing continuous pressure; (i) bone resorption was induced on the periosteal surface (Ps) in the osteoporotic-3.4 kPa group, and on the pressure side of the endocortical surface (p-Ec) in the osteoporotic-1.5 and -3.4 kPa group, (ii) the appearance of osteoclasts on the p-Ec in the osteoporotic-3.4 kPa group was earlier than that on the Ps in a same group, (iii) bone resorption on the pressure side of the Ec in the osteoporotic-3.4 kPa group manifested at the earlier stage than that in the osteoporotic-1.5 kPa group, (iv) bone formation following bone resorption on the p-Ec was observed more markedly than that on the Ps and (v) histopathological changes in the tissues under the denture base in experimental osteoporosis bearing continuous pressure had an intimate relationship with the initial intensity and the time course of continuous pressure.

Animals↗

Reduction of shrinkage on heat-activated acrylic denture base resin obtaining gradual cooling after processing.

Heat-activated acrylic denture base resin is widely used for its many good attributes, although it does show polymerization shrinkage. Although several processing methods have been developed for the purpose of minimizing polymerization shrinkage, some warping after processing is inevitable. The purpose of this study was to examine the development of residual stress relaxation in resin denture base samples in the region where shrinkage was restricted, in order to clarify how cooling variations in the stone mould influenced the shrinkage. Flat, dumbbell-shaped specimens were used. Thermocouples and strain gauges were embedded in the resin for measuring temperature and strain during the dough-stage of resin packing. To clarify stress relaxation in the stone mould, specimens were removed from the stone mould by de-flasking 4 h after the start of cooling at room temperature (control), and 12 and 24 h from the start of gradual cooling in a water bath. The strain differences between before and after removing from the stone mould for the control, and 12- and 24-h experimental groups were 1793, 1354 and 1093 mu epsilon, respectively. Our results suggest that a gradual cooling course for 12 h or more after processing a heat-activated acrylic denture base is effective for lessening deformation of the prosthesis.

Acrylic Resins↗

Evaluation of the properties of a new pour denture base material utilizing a modified technique and initiator system.

A new denture base system, Provac, has been developed for complete and partial dentures, and for relining. The Provac material is methyl methacrylate, which cures with the aid of barbituric acid. In this study the physical and mechanical properties of the new resin were investigated and compared with those of a conventional autopolymerizing material (Croform) and a conventional heat polymerizing material (Trevalon). It was found that the dimensional accuracy of Provac was better than that of the conventional heat-curing material, Trevalon, and the denture was finished more easily and quickly. The physical and mechanical properties of Provac resin were found to be similar to those of the other two materials, and conformed to the International Specifications for denture base materials. The residual monomer levels in Provac material were always higher than the minimal obtainable values associated with conventional heat-cured materials when these were polymerized with a terminal boil during the curing cycle.

Acrylates↗

The use of differential scanning calorimetry for the evaluation of dental materials. Part II. Denture base materials.

The presence of thermal transitions within the working range of denture base polymers may have a drastic effect on the dimensional stability of the material. The glass transition temperatures of fifteen denture base polymers have been measured and their significance discussed. The effect of thermal contraction and polymerization contraction on dimensional stability is not fully understood at the present time. An attempt has been made to explain the dimensional changes which occur in denture bases with the aid of transition temperatures and inferred thermal contraction and polymerization contraction values.

Calorimetry, Differential Scanning↗

Effect of polymerization temperature and time on the residual monomer content of denture base polymers.

The aim of this study was to investigate the effect of polymerization time and polymerization temperature on the residual methyl methacrylate (MMA) content of two heat-cured and two autopolymerized denture base polymers. Gas chromatography was used to determine the residual MMA content of three test specimens of each type of polymer. Increasing the polymerization temperature for the autopolymerized denture base resins from 30 degrees C to 60 degrees C decreased the residual MMA content of the polymer from an average of 4.6 wt% to 3.3 wt%. With the heat-cured denture base resins, a curing cycle at a polymerization temperature of 70 degrees C followed by a period at 100 degrees C significantly reduced the residual monomer content of the polymer when compared with a resin cured at 70 degrees C only. Polymerizing the heat-cured denture base resin at 100 degrees C only for various lengths of time significantly affected the residual MMA content of the polymer. The lowest residual MMA content (0.07 wt%) was obtained by polymerizing the heat-cured denture base resin at 100 degrees C for 12 h. The results of this study suggest that the polymerization temperature and polymerization time considerably affect the residual MMA content of denture base polymers.

Acrylic Resins↗

A subjective study of dimensional stability of permanent acrylic resin complete denture bases after a second curing cycle.

The aim of this study was to subjectively assess permanent denture base retention and stability in order to determine whether detrimental change occurred as a result of a second curing cycle. 100 complete upper denture bases were assessed by clinician and patient using visual analogue scales at try-in and insert. No statistically significant alteration in mean scores for retention and stability was seen. 5% of bases showed some deterioration, but none required rebasing or remaking as a result. The advantages of permanent bases during denture construction seem to outweigh the risk of loss of retention and/or stability as a result of distortion due to the second curing cycle.

Acrylic Resins↗

Comparison of mechanical strength of palatal denture bases made from various plastic materials.

PURPOSE: The aim of the study was to compare the mechanical strength of palatal denture bases made from various plastic materials. MATERIALS AND METHODS: A form and models of an edentulous jaw (Frasaco) were used in the study. The denture bases were made from Zhermacryl H Plus and SR Ivocap Plus (both acrylic resins) and the polyurethane Microbase. Five samples were fabricated for each of the studied polymers. The fracture tests were carried out on a universal testing machine (Hounsfield H5KS). RESULTS: The highest fracture values were assessed on Ivocap specimens. The indicated differences between acrylic resin specimens made of Ivocap and Zhermacryl were not statistically significant. In turn, the differences shown between 2 acrylic resin palatal denture bases and the Microbase were statistically significant (P < .05). CONCLUSION: In this study, samples made from an alternative denture base polymer showed poorer mechanical strength as compared with those made of polymethylmethacrylate.

Acrylic Resins↗

Displacement of mandibular removable partial denture bases by tongue movements during speech.

PURPOSE: The purpose of this study was to evaluate denture base displacement caused by tongue movements during speech. MATERIALS AND METHODS: Ten patients with new Kennedy Class I mandibular removable partial dentures participated in this study. All prostheses were made according to a standardized protocol. Denture base displacements when speaking a test sentence were measured with a computer-aided device that was developed for this purpose. It included 4 Hall sensors, mounted on a paraocclusal splint and magnets, embedded in the denture bases. Vertical and transverse base displacements were calculated from Hall voltages. Clasp retention was measured with a dynamometer. RESULTS: Mean displacements were 145 microns seating, 72 microns unseating, 87 microns buccally, and 74 microns lingually. Seating and unseating displacements differed statistically significantly in absolute values. Mean clasp retention was 2.5 N. No correlation was found between clasp retention and unseating base displacements. CONCLUSION: Tongue movements during speech induced only minimal displacements in the dentures investigated. Additionally, tongue activity was found to be denture stabilizing rather than denture displacing in this study.

Adult↗

Comparison of fracture tests of denture base materials.

STATEMENT OF PROBLEM: Clinical studies have shown midline fracture to be a common problem in dentures. In order to evaluate the resistance of denture base resins against fracture, not only impact strength measurements but also fracture toughness tests should be performed. PURPOSE: The aim of this study was to determine the fracture toughness of denture base resins and to compare the results with impact strength measurements. MATERIALS AND METHODS: Seven heat-polymerized denture base resins were chosen for the study: 5 high impact (GC Luxon, Injectall IPF HI-I, Ivocap Plus, Lucitone 199, and Trevalon HI) and 2 conventional (Major Base 2 and Probase Hot). Three series of 12 specimens were used for the Charpy impact test (specimen dimensions: 80 x 10 x 4 mm, notch depth: 2 mm) and 2 Izod impact tests (specimen dimensions: 50 x 6 x 4 mm; notch depth: 1.2 mm for the first series, 3.4 mm for the second series). The maximum stress intensity factor (K(I,max)) (MPa.m(1/2)) and the work of fracture (WOF) (kJ/m2) were measured for 8 specimens in a fracture toughness test (specimen dimensions: 40 x 8 x 4; notch depth: 3.2 to 3.3 mm). A 1-way ANOVA with a post-hoc Tukey-Kramer test (alpha=.05) was used to compare the data. RESULTS: The results achieved by the different materials and the rankings varied, depending on which parameter was considered. For example, the 1.2-mm Izod impact strength of Ivocap Plus (2.49 +/- 0.24 kJ/m2) was not significantly different from GC Luxon (2.64 +/- 0.15 kJ/m2) and significantly higher than Major Base 2 (1.99 +/- 0.23 kJ/m2) and Probase Hot (1.79 +/- 0.20 kJ/m2) (P<.001). On the other hand, the Charpy impact strength of Ivocap Plus (1.47 +/- 0.16 kJ/m2) was almost half the value of GC Luxon (2.85 +/- 0.05 kJ/m2) and not significantly different from Major Base 2 (1.36 +/- 0.03 kJ/m2) and Probase Hot (1.36 +/- 0.09 kJ/m2). In the fracture toughness test, the K(I,max) values of GC Luxon (2.63 +/- 0.09 MPa.m(1/2)), Lucitone 199 (2.53 +/- 0.08 MPa.m(1/2)), Trevalon HI (2.56 +/- 0.13 MPa.m(1/2)), and Ivocap Plus (2.41 +/- 0.04 MPa.m(1/2)) were not significantly different. Among all parameters, the WOF value appeared to be the test that allowed a clear differentiation between the products, placing Probase Hot (0.27 +/- 0.03 kJ/m2) and Major Base 2 (0.38 +/- 0.03 kJ/m2) on a low level, Injectall IPF HI-I (0.63 +/- 0.17 kJ/m2) on an intermediate level, Ivocap Plus (1.12 +/- 0.06 kJ/m2) on a medium-high level, and Lucitone 199 (1.41 +/- 0.06 kJ/m2), GC Luxon (1.50 +/- 0.17 kJ/m2), and Trevalon HI (1.58 +/- 0.07 kJ/m2) on a high level. CONCLUSION: Specimen geometry and testing configuration influenced the impact strength measurements. The fracture toughness method seems to be more suitable than impact strength measurements to demonstrate the effects of resin modifications. The differences between conventional and so-called "high-impact" denture base resins are more clearly demonstrated with fracture toughness measurements.

Acrylic Resins↗

[An evaluation of the bond strength of plastic teeth to acrylic denture base material].

Plastic teeth are preferred as functional portions with acrylic denture base material. The resin teeth have become the integral part of the denture by their chemical bonding with the base. But several factors effect the bonding: faulty boil-out procedures, residual wax on ridge-laps of the teeth, careless application of tin-foil substitutes to the teeth. On the other hand, grinding the glossy ridge-lap surface, painting the teeth with monomer or a solvent, preparing retention grooves on the ridge-lap portion of the teeth effectively lock the teeth to the denture base. The purpose of this research was to evaluate the bond strengths of the acrylic resin teeth and denture base material with retention grooves on the ridge-lap portion of the teeth. As a result of this study, bond strength between resin teeth and the denture base material is increased by the mechanical retention applied on the ridge-lap portion of the teeth.

Acrylic Resins↗

An in vitro investigation of the abrasive qualities of a selection of denture-cleaning pastes on poly(methyl methacrylate) denture base material.

This study investigated the damage to poly(methyl methacrylate) (PMMA) denture base material caused by brushing with a range of denture-cleaning pastes using an electric, motor-driven, reciprocal-action toothbrushing machine. Plate specimens of PMMA were exposed to 5000, 10,000 and 20,000 brush strokes with four commercial and one recently developed denture-cleaning pastes. Products were applied as slurries in dilutions of 1:2, 1:3 and 1:5. Wear and roughness measurements were made using a surfometer. Results of a one-way analysis of variance showed that there was a statistically significant difference between each of the different denture-cleaning pastes at each given dilution for each number of wear cycles. For the denture-cleaning pastes, doubling the number of brush strokes in most cases, increased the depth of abrasion by a factor of two. A reduction in the Roughness Index and depth of wear was seen, again in most cases, with a dilution from 1:2, 1:3 and to 1:5. A recently developed paste (Blend-a-Dent Hygienic denture paste) bad a comparatively low wear and roughening effect on PMMA denture base material; however, further investigation of its stain-removal properties are necessary before it can be recommended as a suitable denture-cleaning paste.

Analysis of Variance↗