PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Electrocoagulation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Treatment of the textile wastewater by combined electrocoagulation.

Electrocoagulation (EC) due to some advantages over chemical coagulation is becoming a popular process to be used for wastewater treatment. The aim of this paper is to investigate the effect of initial addition of a chemical coagulant such as polyaluminum chloride (PAC) or alum on the COD removal efficiency of EC treatment of textile wastewaters. The two salts exhibited the same performance in chemical coagulation, but in the combined electrocoagulation (CEC), PAC was found to significantly enhance the COD removal rate and efficiency, depending on the amount of the total aluminum supplied, by initial addition and electrochemical generation. A comparative operating cost analysis was also given and it was found that with the same operating cost per mass of COD removed, CEC performance was 80%, in contrast to 23% with EC, in 5 min of operation.

Alum Compounds↗

The investigation of parameters affecting boron removal by electrocoagulation method.

Boron removal from wastewaters by electrocoagulation using aluminum electrode material was investigated in this paper. Several working parameters, such as pH, current density, boron concentration and type and concentration of supporting electrolyte were studied in an attempt to achieve a higher removal capacity. The experiments were carried out by keeping the pH of solution constant and optimum pH of solution was determined 8.0 for the aluminum electrode. Although energy consumption increased with decreasing boron concentration, which conductivity of these solutions were low, boron removal efficiency was higher at 100 mg/L than that of 1000 mg/L. Current density was an important parameter affecting removal efficiency. Boron removal efficiency and energy consumption increased with increasing current density from 1.2 to 6.0 mA/cm2. The types of different supporting electrolyte were experimented in order to investigate to this parameter effect on boron removal. The highest boron removal efficiency, 97%, was found by CaCl2. Added CaCl2 increased more the conductivity of solution according to other supporting electrolytes, but decreased energy consumption. The results showed to have a high effectiveness of the electrocoagulation method in removing boron from aqueous solutions.

Boron↗

Decolorization of basic dye solutions by electrocoagulation: an investigation of the effect of operational parameters.

Electrocoagulation (EC) is one of the most effective techniques to remove color and organic pollutants from wastewater, which reduces the sludge generation. In this paper, electrocoagulation has been used for the removal of color from solutions containing C. I. Basic Red 46 (BR46) and C. I. Basic Blue 3 (BB3). These dyes are used in the wool and blanket factories for fiber dyeing. The effect of operational parameters such as current density, initial pH of the solution, time of electrolysis, initial dye concentration and solution conductivity were studied in an attempt to reach higher removal efficiency. The findings in this study shows that an increase in the current density up to 60-80 A m(-2) enhanced the color removal efficiency, the electrolysis time was 5 min and the range of pH was determined between 5.5 and 8.5 for two mentioned dye solutions. It was found that for, the initial concentration of dye in solutions should not be higher than 80 mg l(-1) in order to achieve a high color removal percentage. The optimum conductivity was found to be 8 mS cm(-1), which was adjusted using proper amount of NaCl with the dye concentration of 50 mg l(-1). Electrical energy consumption in the above conditions for the decolorization of the dye solutions containing BR46 and BB3 were 4.70 kWh(kgdye removed)(-1) and 7.57 kWh(kgdye removed)(-1), respectively. Also, during the EC process under the optimized conditions, the COD decreased by more than 75% and 99% in dye solutions containing BB3 and BR46, respectively.

Coloring Agents↗

Removal of nitrate from water by electroreduction and electrocoagulation.

The aim of this work was to investigate the feasibility of the removal of nitrate from water by applying electrochemical methods such as electroreduction and electrocoagulation. In electroreduction, removal of nitrate to an allowable concentration has been accomplished at the pH range of 5-7 with energy consumption value of 1 x 10(-3) kWh g(-1). In electrocoagulation, an allowable concentration of nitrate has been achieved at the pH range of 9-11 with energy consumption value of 0.5 x 10(-4) kWh g(-1). Full removal of nitrate was also possible but with higher energy consumptions for these two methods.

Electrochemistry↗

Radio frequency leakage current from unipolar laparoscopic electrocoagulators.

Radio frequency (RF) leakage current has been suspected of causing accidental tissue burns associated with laparoscopic electrocoagulation used for tubal sterilization. A study was done to determine the levels of capacitively coupled RF leakage current from six unipolar laparoscopes manufactured by five companies. Leakage current values ranging from less than 100 mA to over 550 mA were measured at electrosurgical unit power settings of up to 150 w into 1,000 ohms. These levels represent 24-62% of the total electrosurgical current generated by the electrosurgical units. Using a criterion for tissue injury of 100 mA/sq cm applied for ten seconds, leakage current levels exceeding 400 mA are capable of producing burns either at the abdominal wall or to internal organs that accidentally come into contact with the body of the laparoscope. One of the six devices tested had leakage current levels higher than 400 mA at power settings lower than 100 w. Capacitance measurements between the unipolar laparoscope body and the forceps ranged from 53 to 140 picofarads.

Electrocoagulation↗

Endoscopic electrocoagulation: an alternative to operative therapy in bleeding peptic ulcer disease.

Twelve patients with severely bleeding peptic ulcers (six duodenal, five gastric, and one esophageal) who were considered to be at high operative risk were treated instead by endoscopic electrocoagulation of the bleeding point. Arrest of the bleeding was permanent in ten, one bled again two days later, and one patient died of nonulcer disease one day later. Although this method to control bleeding from peptic ulceration is new, it seems to offer promise especially when treating desperately ill people.

Aged↗

Treatment of intraoral cancer by electrocoagulation.

Electrocoagulation of intraoral carcinoma has been utilized as primary curative treatment in a series of twenty-five patients. The technique described here employs a disk electrode, requires only light general anesthesia and has a low rate of complications. Eleven patients survived more than five years. Eight died of other diseases and only 6 died with recurrent cancer. This is an effective technique which deserves wider use.

Adult↗

Upper thoracic sympathectomy by transthoracic electrocoagulation.

Transthoracic electrocoagulation (TTEC) of the upper thoracic sympathetic chain is described. In 10 patients the technique was relatively simple and denervation was satisfactory in 9. One temporary Horner's syndrome was produced. The merits of this technique in a preliminary series are compared with other forms of treatment.

Adolescent↗

Immunotherapeutic effect of tumor necrosis after cryosurgery, electrocoagulation, and ligation.

Tumor necrosis in situ by cryosurgery, electrocoagulation, or ligation generally induces or augments some increase in tumor-specific transplantation immunity (TSTI) as compared with excision. Excision of the tumor 24 hours after it has been rendered ischemic by either ligation or cryosurgery seems to produce TSTI that is significantly greater than that after excision of viable tumor without prior ligation or cryosurgery; the degree of this immunity is similar to that seen after the tumor is left in situ indefinitely after treatment. These data suggest that most of the immunization following tumor necrosis in situ occurs within 24 hours of treatment. The experimental findings support the clinical reports of putative immunologic potentiation after tumor necrosis in situ.

Animals↗

Electrocoagulation: palliative surgery to control metastatic cutaneous malignancy.

The adaptation of the principles of electrocoagulation to controlling symptomatic cutaneous metastatic disease is discussed. The technique permits minimal anesthesia, excellent hemostasis, local control, satisfactory cosmesis with reduced hospitalization. Two illustrative cases are reported of metastatic malignant melanoma and metastatic leiomyosarcoma.

Aged↗

The microcirculation in neodymium-YAG laser irradiated and in electrocoagulated urinary bladder tumors evaluated with laser Doppler flowmetry.

Neodymium-YAG laser irradiation is a relatively new therapeutic modality for the treatment of urinary bladder tumors which is suggested to produce an instantaneous arrest of the blood circulation and a homogeneous coagulation of the tumor tissue. Utilizing the laser Doppler flowmetry principle the microcirculatory changes in laser irradiated tumors were compared to the changes in tumors coagulated with diathermy. In laser treated tumors the blood cell flux decreased to near baseline levels throughout coagulated area. Vascular stasis was demonstrated in the erythematous zone encircling the necrosis. In tumors coagulated with diathermy a corresponding constant decrease in blood cell flux could not be demonstrated. Thus the neodymium-YAG laser irradiation seems preferable to electrocoagulation in the treatment of urinary bladder tumors as more complete and homogeneous arrest of the blood circulation in the treated area is achieved.

Electrocoagulation↗

Bipolar electrocoagulation versus Nd-YAG laser photocoagulation for upper gastrointestinal bleeding lesions.

Nd-YAG laser photocoagulation and bipolar electrocoagulation may be useful for controlling upper gastrointestinal bleeding or preventing rebleeding from ulcers with visible vessels. To determine if one of these methods is superior to the other, data from a small randomized trial and from a nonrandomized experience were evaluated. Altogether, 33 patients underwent 37 coagulation sessions; 19 of the patients were randomized (8 laser and 11 bipolar). In the randomized group, 47.4% had no rebleeding after therapy (laser = 37.5% and bipolar = 54.5%, P greater than 0.1). In the nonrandomized group 56.8% had no further bleeding. Eleven (33%) of the patients required surgery. No patients died of bleeding or complications related to the study. From these data and those in the literature, it is concluded that the Nd-YAG laser and the bipolar coagulator are equally effective for the treatment of solitary upper gastrointestinal bleeding lesions. Since the bipolar unit is cheaper and more easily transported than the laser unit, it may be the method of choice for cauterizing upper gastrointestinal sources until a more effective method is developed.

Adult↗

Palliative bipolar electrocoagulation treatment of malignant gastroesophageal strictures.

Seventeen patients with non-resectable circumferential malignant strictures of the esophagus (n = 13) or the gastroesophageal junction (n = 4) were treated with a bipolar electrocoagulation tumor probe (BICAP). None had received prior radiotherapy or chemotherapy. The mean tumor length was 7.2 cm. After treatment swallowing was improved in 86.7% of the patients. The mean duration of response to the first treatment was 18 days. Three major complications (1 fatal hemorrhage, 2 tracheoesophageal fistulae) and two minor complications (chest pain) were observed. The overall actuarial survival rate after 13 months of follow-up was 20%. The BICAP tumor probe can be considered an efficacious and safe device in selected patients with long, circumferential esophageal cancers.

Actuarial Analysis↗

Vessel occlusion with transcatheter electrocoagulation.

Transcatheter intravascular electrocoagulation for therapeutic occlusion of vessels has been experimentally developed and successfully used clinically as an alternative to, and in conjunction with, more routine methods of vessel occlusion. A constant current power source and a steelguide wire anode are used for the occlusion. The subject is grounded with a standard bovie plate insulated from the skin by a highly lubricated sponge. Permanent occlusion of strategic vessels at accurately controlled sites has been achieved with little risk of embolization of non-target areas. There has been minimal damage to vessel walls, and complete occlusion has been possible despite heparinization and/or thrombocytopenia. One limitation is the inconstant ability to position the anode precisely at the desired site of occlusion. Also, a long time may be required (up to one hour) to occlude larger vessels with presently available anodes. Wider use must await refinements in development of the anode material and in its delivery system.

Arteriovenous Fistula↗

Endoscopic bipolar electrocoagulation in massive upper gastrointestinal bleeding.

We have reviewed 50 cases of upper gastrointestinal bleeding treated by endoscopic bipolar electrocoagulation (BPEC) and assessed its value in the management of massive bleeding. Initial hemostasis was achieved in 94% of cases with an overall rebleeding rate of 19.1%. The rebleeding rate was high among patients requiring blood transfusions more than 2,000 ml (47.3%) and those with acute gastric mucosal lesion (AGML) (35.3%). In AGML one or two primary sites of bleeding can be effectively controlled initially, but rebleeding tends to occur from other sites. Mortality from the direct effects of bleeding was also high in massive bleeders (33.3%) and those with AGML (22.2%); the overall mortality, including deaths from ongoing underlying diseases, was 38%. Although BPEC failed to alter the fatal outcome of patients with massive acute mucosal bleeding, permanent or temporary hemostasis contributed to reducing the amount of blood transfusions, avoiding emergency operation, preventing rapid deterioration and prolonging the survival time. Endoscopic BPEC has proven to be an effective emergency hemostatic method in massive bleeding of the upper gastrointestinal tract as an alternative to surgical intervention.

Adolescent↗

Endoscopic bipolar electrocoagulation in upper gastrointestinal bleeding.

A total of 213 cases of upper gastrointestinal bleeding treated by bipolar electrocoagulation (BPEC) were reviewed and its efficacy in the management of massive bleeding was evaluated. Initial hemostasis was achieved by BPEC in 97.6% cases with an overall rebleeding rate of 17.1%. The majority of rebleeding occurred in patients with acute mucosal lesions who had serious underlying medical problems. There were no complications related to the procedure. Endoscopic BPEC safely arrested oozing to spurting bleeding and contributed greatly to the control of upper gastrointestinal bleeding.

Adolescent↗

Gastrointestinal stromal tumor in the jejunum: diagnosis and control of bleeding with electrocoagulation by using double-balloon enteroscopy.

A 43-year-old man presented with gastrointestinal bleeding. A tumor with central ulceration was observed in the jejunum, with the use of a new enteroscopy system called "double-balloon enteroscopy". Bleeding after biopsy sampling of the tumor was controlled endoscopically by using electrocoagulation. Histological findings of the biopsy specimens were consistent with gastrointestinal stromal tumor, and this was surgically resected. Double-balloon enteroscopy was useful for the diagnosis as well as the control of bleeding in this patient.

Adult↗