PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Flow”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Analysis of variable flow Doppler hemodialysis access flow measurements and comparison with ultrasound dilution.

The variable flow (VF) Doppler method determines access blood flow from the pump speed-induced change in Doppler signal between the arterial and venous needles. This study evaluated 35 patients in two analyses to assess VF Doppler measurement reproducibility (54 paired measurements) and compared VF Doppler and ultrasound dilution flow measurements (24 paired measurements). VF Doppler measurement variations were 4% for access flow less than 800 mL/min (n = 17), 6% for access flow of 801 to 1,600 mL/min (n = 22), and 11% for access flow greater than 1,600 mL/min (n = 15). The mean measurement coefficient of variation was 7% for VF Doppler compared with 5% for ultrasound dilution. Correlation coefficients (r) between VF Doppler and ultrasound dilution access flow measurements were 0.79 (n = 24; P < 0.0001), 0.84 for access flow less than 2,000 mL/min (n = 20; P < 0.0001), and 0.91 for access flow less than 1,600 mL/min (n = 18, P < 0.0001). VF Doppler measurements using indicated versus measured pump flow rates correlated highly (r = 0.99; P < 0.0001). VF Doppler therefore yields reproducible access volume flow measurements that correlate with ultrasound dilution measurements. The VF Doppler method is dependent on the pump-induced change in access Doppler signal and therefore is inherently most accurate and reproducible at lower access blood flow rates. This method appears capable of determining access flow rates in the clinically useful range.

Blood Flow Velocity↗

PIV measurements of flow in a centrifugal blood pump: steady flow.

Magnetically suspended left ventricular assist devices have only one moving part, the impeller. The impeller has absolutely no contact with any of the fixed parts, thus greatly reducing the regions of stagnant or high shear stress that surround a mechanical or fluid bearing. Measurements of the mean flow patterns as well as viscous and turbulent stresses were made in a shaft-driven prototype of a magnetically suspended centrifugal blood pump at several constant flow rates (3-9 L/min) using particle image velocimetry (PIV). The chosen range of flow rates is representative of the range over which the pump may operate while implanted. Measurements on a three-dimensional measurement grid within several regions of the pump, including the inlet, blade passage, exit volute, and diffuser are reported. The measurements are used to identify regions of potential blood damage due to high shear stress and/or stagnation of the blood, both of which have been associated with blood damage within artificial heart valves and diaphragm-type pumps. Levels of turbulence intensity and Reynolds stresses that are comparable to those in artificial heart valves are reported. At the design flow rate (6 L/min), the flow is generally well behaved (no recirculation or stagnant flow) and stress levels are below levels that would be expected to contribute to hemolysis or thrombosis. The flow at both high (9 L/min) and low (3 L/min) flow rates introduces anomalies into the flow, such as recirculation, stagnation, and high stress regions. Levels of viscous and Reynolds shear stresses everywhere within the pump are below reported threshold values for damage to red cells over the entire range of flow rates investigated; however, at both high and low flow rate conditions, the flow field may promote activation of the clotting cascade due to regions of elevated shear stress adjacent to separated or stagnant flow.

Algorithms↗

Determination of prestenotic flow volume using an automated method based on colour Doppler imaging for evaluating orifice area by the continuity equation: validation in a pulsatile flow model.

OBJECTIVE: To evaluate, in a pulsatile flow model simulating flow conditions in valvar stenoses, whether accurate determination of orifice area can be achieved by the continuity equation using automated determination of flow volumes based on spatiotemporal integration of digital colour Doppler flow velocities. METHODS: A method for automated determination of flow volumes which takes into account the velocity distribution across a region of interest was examined using flow through a tube and various restrictive outlet orifices with areas ranging between 0.2 and 3.1 cm2. The sampling rectangle of the Doppler method was positioned proximal to the obstructions within the flow convergence zone for evaluating prestenotic flow volume. Stenotic jet velocities were recorded by continuous wave Doppler to obtain the integral under the velocity curve. Prestenotic flow volume was then divided by the velocity integral to calculate functional orifice area according to the continuity equation. RESULTS: The presence of parabolically shaped velocity profiles across the prestenotic region was demonstrated by the Doppler method. Excellent agreement was found between prestenotic flow volumes measured by the Doppler technique and actual values (r = 0.99, SEE = 1.35 ml, y = 0.99x-0.24). Use of the continuity equation led to a close correlation, with a systematic underestimation of geometric orifice sizes. Correction of Doppler data for flow contraction yielded an excellent agreement with actual orifice areas. CONCLUSIONS: The study validated the accuracy of a Doppler method for automated determination of flow volumes for quantifying orifice area by the continuity equation. Prestenotic flow volume and functional orifice area could be evaluated reliably in the presence of non-flat velocity profiles. Thus the method contributes to the non-invasive assessment of valvar stenoses.

Echocardiography, Doppler, Color↗

Blood flow distribution in working in situ canine muscle during blood flow reduction.

The purpose of this study was to determine whether reduction in apparent muscle O2 diffusing capacity (Dmo2) calculated during reduced blood flow conditions in maximally working muscle is a reflection of alterations in blood flow distribution. Isolated dog gastrocnemius muscle (n = 6) was stimulated for 3 min to achieve peak O2 uptake (VO2) at two levels of blood flow (controlled by pump perfusion): control (C) conditions at normal perfusion pressure (blood flow = 111 +/- 10 ml.100 g-1.min-1) and reduced blood flow treatment [ischemia (I); 52 +/- 6 ml.100 g-1.min-1]. In addition, maximal vasodilation was achieved by adenosine (A) infusion (10(-2)M) at both levels of blood flow, so that each muscle was subjected randomly to a total of four conditions (C, CA, I, and IA; each separated by 45 min of rest). Muscle blood flow distribution was measured with 15-microns-diameter colored microspheres. A numerical integration technique was used to calculate Dmo2 for each treatment with use of a model that calculates O2 loss along a capillary on the basis of Fick's law of diffusion. Peak VO2 was reduced significantly (P < 0.01) with ischemia and was unchanged by adenosine infusion at either flow rate (10.6 +/- 0.9, 9.7 +/- 1.0, 6.7 +/- 0.2, and 5.9 +/- 0.8 ml.100 g-1.min-1 for C, CA, I, and IA, respectively). Dmo2 was significantly lower by 30-35% (P < 0.01) when flow was reduced (except for CA vs. I; 0.23 +/- 0.03, 0.20 +/- 0.02, 0.16 +/- 0.01, and 0.13 +/- 0.01 ml.100 g-1.min-1.Torr-1 for C, CA, I, and IA, respectively). As expressed by the coefficient of variation (0.45 +/- 0.04, 0.47 +/- 0.04, 0.55 +/- 0.03, and 0.53 +/- 0.04 for C, CA, I, and IA, respectively), blood flow heterogeneity per se was not significantly different among the four conditions when examined by analysis of variance. However, there was a strong negative correlation (r = 0.89, P < 0.05) between Dmo2 and blood flow heterogeneity among the four conditions, suggesting that blood flow redistribution (likely a result of a decrease in the number of perfused capillaries) becomes an increasingly important factor in the determination of Dmo2 as blood flow is diminished.

Animals↗

Effects of pulmonary venous flow direction on mitral regurgitation jet area as imaged by color Doppler flow mapping. An in vitro study.

BACKGROUND: Although the effects of adjacent walls and left atrial pressure on mitral regurgitation (MR) jet area imaged by color Doppler have been examined, few data exist regarding the influence of pulmonary venous (PV) filling flow on regurgitant jets. Therefore, we designed a left atrial model to examine the relation between PV flow direction and MR jet area. METHODS AND RESULTS: The left atrial chamber (7.6 cm in diameter) was built with a PV inflow (1.0 cm in diameter) and mitral valve regurgitant orifice in the same plane. The MR jet was simulated as fixed in volume and velocity (3.5 m/s) and directed with a pulsatile pump into the left atrial model. PV flow with a constant velocity (30 cm/s) was driven by gravity (83 cm H2O). With left atrial mean pressure at either 10, 30, or 50 mm Hg, four flow patterns were examined: (1) PV flow away from the mitral valve, MR jet toward the pulmonary vein; (2) PV flow toward the mitral valve, MR jet toward the pulmonary vein; (3) PV flow away from the mitral valve, MR jet away from the pulmonary vein; and (4) PV flow toward the mitral valve, MR jet away from the pulmonary vein. MR color Doppler images were recorded with a 3.5-mHz frequency transducer and at 7-kHz pulse repetition frequency. For each condition, we compared jet area, length, and width of the MR signal. MR jet areas for conditions 3 and 4 were larger at 10 mm Hg than at 30 or 50 mm Hg left atrial pressure. Especially at the lower pressures, PV flow diminished the MR jet area in condition 4 compared with that in condition 3, such that MR jets were smaller in condition 4. In conditions 1 and 2, the jets were imaged at an oblique angle and were smaller than in conditions 3 and 4 (P < .001), but they were not significantly different from each other as imaged. CONCLUSIONS: In this model, factors including the direction of PV flow, the direction of MR as relates to the angle of interrogation, and the level of left atrial pressure influenced the size of MR jets. The effect of PV flow direction was diminished by increased left atrial pressure. PV flow directed away from the mitral valve was associated with larger MR jets than when PV flow was directed toward it (condition 4), probably because of jet distortion and flattening.

Blood Flow Velocity↗

Decreased hydrodynamic resistance in the two-phase flow of blood through small vertical tubes at low flow rates.

The aggregation of red blood cells in blood flowing through small tubes at very low shear rates leads to the two-phase flow of an inner core of rouleaux surrounded by a cell-depleted peripheral layer. The formation of this layer is known to be accompanied by a decrease in hydrodynamic resistance to flow. To quantitate this effect, we measured the pressure gradient, flow rate, and the radius of the red blood cell core in suspensions flowing through tubes of 172-microns radius at mean linear flow rates (U) from 50 to 0.15 tube diameters.sec-1. Washed red blood cells were suspended in 1.5% buffered dextran 110 at hematocrits of 34-52%. Using syringe pumps, blood flowed from a stirred reservoir through a vertical 12-cm length of tube in either the upward or downward direction. The pressure drop was measured with transducers. Mean values in distributions in the core radius were obtained by analyzing cine films of flow taken through a microscope with flow in the upward direction, measuring the core radius at five equally spaced axial positions of the tube in each of 100 frames. At 34% and 46% hematocrit, the hydrodynamic resistance increased as U decreased from 50 sec-1, reaching a maximum at U-2 sec-1. It then decreased to a minimum at U less than 0.5 sec-1 as the red blood cell core formed in the tube, and the mean core radius/tube radius ratio decreased from 0.98 to 0.74 with marked axial fluctuations at the lower U. At higher hematocrits, both the increase and decrease in hydrodynamic resistance were greater. In a red blood cell albumin-saline suspension, where there is no aggregation of red blood cells and no two-phase flow, hydrodynamic resistance increases linearly with decreasing U. The experimental results were compared with the predictions of a two-phase steady-flow model, assuming axisymmetric flow of a core surrounded by cell-free suspending medium. Two models were considered, one in which the core is solid, the other in which the rheological properties of the suspension in the core are given by the Quemada equation. The effects of sedimentation of the core resulting in a zero net flow pressure gradient were taken into account. Provided that an experimentally extrapolated value for the zero pressure gradient was used, the Quemada-fluid model gave good agreement with the experimentally observed core radius as a function of U and hematocrit.

Blood Flow Velocity↗

Effect of flow reduction on coronary blood flow heterogeneity.

The purpose of this study was to test the hypothesis that under reduced flow conditions, spatial heterogeneity (segment-to-segment variability) of myocardial blood flow would be inversely proportional to the rate of perfusion and that vasoconstriction would alter this relationship in anesthetized open-chest dogs. A carotid-left circumflex coronary artery shunt was created. Coronary blood flow determinations employed the radioactive microsphere technique. Fifty tissue samples were obtained from the affected left ventricle, including subepicardial and subendocardial samples. The coefficient of variation (CV = 100 x SD/mean), an index of spatial heterogeneity, was computed. Flows were obtained under three separate conditions: control, a 50% flow reduction in the circumflex artery, and vasopressin infusion, in which the administered dose reduced circumflex artery flow by 50%. The within-animal CV increased from a control of 18 +/- 9 to 45 +/- 25 with partial occlusion and 46 +/- 18 with vasopressin. No significant differences in CV were found between the two reduced flow conditions. A significant linear relationship between CV and mean coronary flow was found (r = 0.51, P < 0.001) over the entire range of flows studied (CV = -0.34*flow + 50.91) for control, 50% occlusion, and vasopressin treatment. The correlation was significantly improved (r = 0.69) using the equation CV = (1319.06/flow) + 4.44. Thus, the relative heterogeneity of coronary blood flow increased with reductions in coronary blood flow, regardless of the means of flow reduction.

Analysis of Variance↗

The superiority of TIMI frame count in detecting coronary flow changes after coronary stenting compared to TIMI Flow Classification.

AIMS: We compared the qualitative Thombolysis in Myocardial Infarction (TIMI) Flow Classification with a new quantitative method, the TIMI Frame Count, to investigate the differences of both systems in detecting coronary flow changes after stent implantation. METHODS: TIMI flow grades and corrected TIMI frame counts (CTFC) were determined in 102 patients before, after stent implantation and at 6-month angiography. Analysis of the CTFC in patients with TIMI flow grades 3 and 2 demonstrated that for CTFC values lower than 30 frames, all patients had TIMI flow grade 3, while for CTFC values greater than 69 frames no patient had TIMI grade 3 flow. For CTFC values between 30 and 69 frames, TIMI grades 3 and 2 flow overlap. Comparing changes in TIMI flow grades and the CTFC before and after stent implantation (after stent implantation and at 6 month angiography), CTFC detects flow changes in 46% (40%) of the patients, which were not detected with TIMI Flow Classification. CONCLUSION: The TIMI Flow Classification grading system is not able to separate clearly between completely perfused and partially perfused coronary artery vessels. The quantitative TIMI Frame Count method is superior to the qualitative TIMI Flow Classification in detecting coronary flow changes.

Adult↗

Recovery of cerebral blood flow and energy state in piglets after hypothermic circulatory arrest versus recovery after low-flow bypass.

A miniature piglet model that replicates clinical hypothermic (14 degrees C nasopharyngeal) circulatory arrest and low-flow (50 ml/kg per minute) bypass was used to study carotid blood flow with electromagnetic flow probe, cerebral blood flow by microsphere injection, cerebral metabolic rate by arteriovenous oxygen and glucose extractions, lactate production by cerebral arteriovenous difference, and cerebral edema. Data from five animals that underwent circulatory arrest and five animals that underwent low-flow bypass (aged 28.8 +/- 0.4 [mean +/- standard error of the mean] days) were analyzed. The duration of circulatory arrest and low-flow bypass was 1 hour. In a parallel study with the same animal model, phosphorus 31 magnetic resonance spectroscopy was used to assess cerebral phosphocreatine, nucleoside triphosphate (adenosine triphosphate), and intracellular pH. Five animals (aged 31.8 +/- 1.1 days) underwent circulatory arrest, and five underwent low-flow bypass. A brief phase of hyperemic carotid blood flow was seen immediately after the onset of reperfusion in the circulatory arrest group but not in the low-flow group. In the circulatory arrest and low-flow bypass groups, cerebral blood flow (percentage of baseline 71.2% +/- 8.3% and 69.1% +/- 5.8%, respectively), cerebral oxygen consumption (45.6% +/- 10.0%, 44.5% +/- 7.6%), and cerebral glucose consumption (31.5% +/- 30.7%, 83.5% +/- 24.2%) remained depressed after 45 minutes of reperfusion and rewarming to normothermia. However, after 3 more hours of pulsatile normothermic reperfusion, cerebral oxygen consumption and cerebral glucose consumption had returned to baseline. Phosphocreatine, adenosine triphosphate, and pH were maintained at or above baseline levels throughout low-flow bypass and throughout 3 hours of normothermic reperfusion. In contrast, both phosphocreatine and adenosine triphosphate became undetectable 32 +/- 3.7 minutes after onset of circulatory arrest. During and early after circulatory arrest, pH decreased to a minimum of 6.506 +/- 0.129 at 40 minutes after reperfusion. After 3 hours of normothermic reperfusion, phosphocreatine and adenosine triphosphate recovered to 98.6% +/- 9.0% and 90.1% +/- 13.5% of baseline, respectively, and pH was 7.087 +/- 0.051, similar to baseline (7.1755 +/- 0.041). In the low-flow bypass group, the disparity between the depressed level of cerebral oxygen consumption and normal high-energy phosphate levels may reflect incomplete cerebral rewarming or decreased energy consumption. In the circulatory arrest group, the parallel recovery of oxygen consumption and high-energy phosphates eventually achieving baseline levels suggests that the degree of hypothermia used provides adequate protection for acute cerebral recovery after 1 hour of circulatory arrest.(ABSTRACT TRUNCATED AT 400 WORDS)

Adenosine Triphosphate↗

Coupling gravitational and flow field-flow fractionation, and size-distribution analysis of whole yeast cells.

This work continues the project on field-flow fractionation characterisation of whole wine-making yeast cells reported in previous papers. When yeast cells are fractionated by gravitational field-flow fractionation and cell sizing of the collected fractions is achieved by the electrosensing zone technique (Coulter counter), it is shown that yeast cell retention depends on differences between physical indexes of yeast cells other than size. Scanning electron microscopy on collected fractions actually shows co-elution of yeast cells of different size and shape. Otherwise, the observed agreement between the particle size distribution analysis obtained by means of the Coulter counter and by flow field-flow fractionation, which employs a second mobile phase flow as applied field instead of Earth's gravity, indicates that yeast cell density can play a major role in the gravitational field-flow fractionation retention mechanism of yeast cells, in which flow field-flow fractionation retention is independent of particle density. Flow field-flow fractionation is then coupled off-line to gravitational field-flow fractionation for more accurate characterisation of the doubly-fractionated cells. Coupling gravitational and flow field-flow fractionation eventually furnishes more information on the multipolydispersity indexes of yeast cells, in particular on their shape and density polydispersity.

Cell Fractionation↗

Competitive flow from a fully patent coronary artery does not limit acute mammary graft flow.

The shriveled, stenotic mammary graft sometimes observed after internal mammary artery (IMA) to coronary artery bypass grafting has been attributed to competitive flow from the insufficiently stenosed native coronary vessel. To study further the effects of native coronary artery competing flow on IMA graft flow, 10 dogs (mean weight, 23.5 +/- 3.69 kg) underwent coronary artery bypass grafting using the pedicled left IMA anastomosed to a normal, fully patent proximal circumflex (CFX) coronary artery. The procedure was performed through a left thoracotomy, off pump, using a brief local occlusion to perform the anastomosis. Native in situ IMA flow, CFX flow distal to the anastomosis, and IMA graft flow were measured using calibrated electromagnetic flow probes. When the CFX proximal to the anastomosis was occluded transiently, IMA flow increased to supply 100% of the previously measured distal CFX flow (60.2 +/- 7.9 mL/min). When both the IMA graft and CFX proximal to the anastomosis were patent, total distal perfusion was maintained (58.9 +/- 7.8 mL/min) and relative IMA graft flow (26.5 +/- 3.3 mL/min) was proportional to the relative diameter of the IMA graft to the native coronary artery (r = 0.96). The mean flow in the IMA in situ on the chest wall before its division was 23.8 +/- 8.1 mL/min. These results suggest that, at least acutely in a canine model, IMA graft flow is maintained above in situ levels even when grafted to a completely patent coronary artery and that acute competitive flow probably does not cause mammary artery shriveling.

Animals↗

Quantification of myocardial blood flow and flow reserve in children with a history of Kawasaki disease and normal coronary arteries using positron emission tomography.

OBJECTIVES: The purpose of this investigation was to determine whether myocardial blood flow and flow reserve, based on quantitative measurements derived from positron emission tomographic (PET) imaging, would be globally impaired in children with a previous history of Kawasaki disease and normal epicardial coronary arteries. BACKGROUND: Kawasaki disease is an acute inflammatory process of the arterial walls that results in panvasculitis in early childhood. Children with a history of Kawasaki disease and normal epicardial coronary arteries were previously considered to have normal coronary flow reserve. However, recent studies have reported exercise-induced regional perfusion abnormalities on single-photon positron emission tomographic (SPECT) imaging. METHODS: We assessed myocardial blood flow and flow reserve at rest and during adenosine stress with nitrogen-13 ammonia and PET in 10 children with a history of Kawasaki disease and in 10 healthy young adult volunteers. All children had acute Kawasaki disease 4 to 15 years before the PET study. None of the children had epicardial coronary artery abnormalities at the acute stage of the disease or during follow-up, as assessed by echocardiography. RESULTS: Rest blood flows normalized to the rate-pressure product, an index of cardiac work, were similar in both the patients with Kawasaki disease and healthy adult volunteers (82 +/- 14 vs. 77 +/- 16 ml/100 g per min [mean +/- SD], p = NS). However, hyperemic blood flows were significantly lower in the patients with Kawasaki disease than in the control subjects (263 +/- 64 vs. 340 +/- 57 ml/100 g per min, p = 0.01). As a result, estimates of myocardial flow reserve were lower in the patients with Kawasaki disease than in the healthy young adult volunteers (3.2 +/- 0.7 vs. 4.6 +/- 0.9, p = 0.003). In addition, total coronary resistance was higher in the patients with Kawasaki disease than in the healthy adult volunteers (33 +/- 11 vs. 24 +/- 5 mm Hg/ml per g per min, p = 0.04). Quantitative analysis of perfusion images demonstrated no evidence of regional perfusion abnormalities. CONCLUSIONS: Children with a previous history of Kawasaki disease and normal epicardial coronary arteries exhibit normal rest myocardial blood flows but reduced hyperemic flows and flow reserve. The abnormal hyperemic blood flows and flow reserve suggest an impaired vasodilatory capacity, possibly due to residual damage of the coronary microcirculation.

Adenosine↗

Doppler echocardiographic analysis of flow in the ductus arteriosus of infants with hypoplastic left heart syndrome: relationship of flow patterns to systemic oxygenation and size of interatrial communication.

Excessive pulmonary overcirculation related to imbalance in the pulmonary/systemic vascular resistance ratio contributes to hemodynamic instability in infants with the hypoplastic left heart syndrome. Because the ductus arteriosus bridges the two vascular circuits in this lesion, we studied the Doppler echocardiographic flow patterns in the ductus arteriosus of 50 infants with hypoplastic left heart syndrome to investigate their relationship to the degree of pulmonary blood flow as measured by simultaneously obtained levels of partial pressure of oxygen in arterial blood. The degree of restriction to pulmonary venous egress as determined by size of the interatrial communication was also correlated with ductal flow patterns and partial pressure of oxygen in arterial blood. Biphasic flow was noted in all infants. Mean peak velocity of antegrade flow (pulmonary artery to aorta) was greater than that of retrograde flow (aorta to pulmonary artery) (131 +/- 45 cm/sec versus 54 +/- 15 cm/sec; p < 0.001), mean time of retrograde flow was greater than that of antegrade flow (246 +/- 60 msec versus 174 +/- 28 msec; p < 0.001), and mean velocity-time integral of antegrade flow was greater than that of retrograde flow (13.3 +/- 4.8 cm versus 6.3 +/- 3.4 cm; p < 0.001). The ratio of velocity-time integral of retrograde flow/antegrade flow (a volumetric estimate of diastolic reversal into the pulmonary vascular bed indexed to systemic output) correlated extremely well with partial pressure of oxygen in arterial blood (r = 0.91; p < 0.0001). Categoric size of the interatrial communication (none, n = 2; small [<2 mm], n = 9; moderate [3 to 4 mm], n = 23; and large [>4 mm], n = 16) correlated with partial pressure of oxygen in arterial blood (r = 0.82; p < 0.001); the smaller the interatrial communication the lower the partial pressure of oxygen in arterial blood and velocity-time integral ratio of retrograde/antegrade flow. Doppler flow patterns in the ductus arteriosus of infants with hypoplastic left heart syndrome are reflective of the resistance ratio between the pulmonary and systemic vascular circuits and may be helpful in monitoring the hemodynamics of these infants.

Analysis of Variance↗

Effect of pump flow rate on cerebral blood flow during hypothermic cardiopulmonary bypass in adults.

OBJECTIVE: The purpose of this study was to examine the effect of cardiopulmonary bypass flow rate on cerebral blood flow and cerebral metabolic rate for oxygen during hypothermic (27 degrees C) cardiopulmonary bypass. DESIGN, SETTING, AND PARTICIPANTS: The investigation was a prospective, randomized study in a tertiary care hospital setting. The 30 participants were volunteer adult cardiac surgical patients at a single institution. INTERVENTIONS: The N2O saturation method of Kety and Schmidt was used to determine global cerebral blood flow and metabolic rate during four periods: prebypass, cardiopulmonary bypass (CPB) (27 degrees C) flow rates of 2.3 and 1.2 L/min/m2, and 30 minutes post-CPB. Anesthesia consisted of fentanyl and midazolam; pH management was alpha-stat, and mean arterial pressure was maintained at 50 to 70 mmHg throughout CPB. MEASUREMENTS AND MAIN RESULTS: In the context of an unchanged mean arterial pressure, the pump flow did not affect cerebral blood flow or metabolic rate during hypothermic CPB. Systemic venous oxygen saturation was also maintained during reduced flow at 27 degrees C. Hemodilution during hypothermic CPB maintained cerebral blood flow at prebypass levels. In the postbypass period, persistent hemodilution resulted in an elevated cerebral blood flow. CONCLUSIONS: Brain oxygenation is well maintained at lower than conventional pump flow levels during CPB. There may be practical advantages to reduced flows during hypothermia, and flow reductions do not appear to adversely affect cerebral blood flow or metabolism.

Adult↗

Comparison of inspiratory work of breathing between flow-triggered and pressure-triggered demand flow systems in rabbits.

OBJECTIVES: Flow-triggered continuous positive airway pressure decreases the inspiratory work of breathing in adults when compared with pressure-triggered continuous positive airway pressure. However, the effect of flow-triggered continuous positive airway pressure on work of breathing in neonates is not known. Our objective was to determine if flow-triggering was superior to pressure triggering in the presence of narrow endotracheal tubes, such as those tubes used in neonates. DESIGN: Prospective evaluation using within-animal comparison of flow-triggering and pressure-triggering demand flow systems. SETTING: The animal laboratory in a university hospital. SUBJECTS: Six spontaneously breathing white rabbits, tracheostomized and intubated with 3- and 4-mm inner diameter endotracheal tubes. INTERVENTIONS: The animals were connected to a ventilator through a standard respiratory circuit. The ventilator was randomly operated in the following modes: flow-triggered continuous positive airway pressure, pressure-triggered continuous positive airway pressure, flow-triggered with 5 cm H2O pressure support ventilation, and pressure-triggered with 5 cm H2O pressure support ventilation. MEASUREMENTS AND MAIN RESULTS: Esophageal pressure, airway pressure, and flow signals were monitored. Control data were obtained while the rabbits were breathing room air through the endotracheal tube. With 3-mm inner diameter endotracheal tubes, the negative deflection of esophageal pressure during flow-triggered continuous positive airway pressure was significantly less than control; however, negative deflection of esophageal pressure during pressure-triggered continuous positive airway pressure did not significantly differ from control. The application of 5 cm H2O pressure support ventilation with flow-triggering decreased negative deflection of esophageal pressure significantly compared with flow-triggered continuous positive airway pressure, pressure-triggered continuous positive airway pressure, and control. With endotracheal tube inner diameter of 4 mm, flow-triggered continuous positive airway pressure and pressure-triggered continuous positive airway pressure did not show any differences compared to control. Negative deflection of esophageal pressure differed under all conditions except control when results with the 3-mm inner diameter endotracheal tube were compared with the 4-mm inner diameter endotracheal tube. CONCLUSIONS: Flow-triggering is superior to pressure-triggering in the presence of a 3-mm inner diameter endotracheal tube. This difference was not clear with a 4-mm inner diameter endotracheal tube. The size of the endotracheal tube may be the most important variable in evaluating the approach used to ventilate small neonates.

Air Pressure↗

Systemic blood flow to sheep lung: comparison of flow probes and microspheres.

Discrepancies exist between experimental measurements of the systemic blood flow to sheep lung by use of microsphere techniques and flow probes on the bronchial artery. In these studies, we simultaneously measured the blood flow through the bronchial artery, using a transit time flow probe, and the systemic blood flow to left lung, using radioactive microspheres. All measurements were made on conscious sheep previously prepared with chronic catheterizations of the left atrium, aorta, and vena cava and a flow probe around the bronchial artery. Inflatable occluder cuffs were placed around the pulmonary and bronchoesophageal arteries. Bronchial artery blood flow in six sheep was 25.3 +/- 5.2 ml/min or 0.4% of the cardiac output. Systemic blood flow to left lung, measured with microspheres, was 54.1 +/- 14.2 ml/min. Calculated systemic blood flow to that portion of sheep lung perfused by the bronchial artery was 127.6 +/- 35.3 ml/min or 1.9% of cardiac output. Occlusion of the bronchoesophageal artery reduced bronchial artery flow to near zero, whereas total systemic blood to the lung was reduced by only 55%. Blood flow to the intraparenchymal cartilaginous airways was reduced 60-90% after occlusion of the bronchoesophageal artery. Sheep, like most mammals, have multiple and complex systemic arterial inputs to the lungs. We conclude that multiple branches of the bronchoesophageal artery provide most but not all of the systemic blood flow to the intraparenchymal cartilaginous airways but that over one-half of the total systemic blood flow to sheep lung comes from sources other than the common bronchial artery.

Animals↗

Measurement of absolute epicardial coronary artery flow and flow reserve with breath-hold cine phase-contrast magnetic resonance imaging.

BACKGROUND: Noninvasive measurement of absolute coronary arterial flow and coronary flow reserve would be of considerable use in the diagnosis and management of patients with coronary artery disease. Phase-contrast magnetic resonance imaging (MRI) has been used to measure flow in a variety of vessels. The goal of the present study was to determine if MRI measurements of coronary artery flow in a single breath-hold can be used to determine flow reserve and the severity of pericardial stenosis. METHODS AND RESULTS: In eight mongrel dogs, a closed chest model of partial left anterior descending coronary artery (LAD) occlusion was created. Coronary flows in the left circumflex artery (LCx) and LAD were measured at rest and during adenosine infusion using velocity-encoded, breath-hold MRI and perivascular ultrasound (US) flowmeters. MRI measurements of absolute coronary flow and coronary flow reserve were highly correlated with US (r = .96 and .94, respectively). Flow reserve measured in the constricted LAD was significantly lower than that in the unconstricted LCx by both US (P = .002) and MRI (P = .011). CONCLUSIONS: MRI measurements of coronary flow and flow reserve were in good agreement with US measurements. In addition, MRI measurements of coronary flow reserve successfully discriminated stenotic from normal vessels. These results indicate that MRI is a useful method for the noninvasive assessment of coronary flow and stenosis.

Adenosine↗

Relationship of brain blood flow and oxygen consumption to perfusion flow rate during profoundly hypothermic cardiopulmonary bypass. An experimental study.

A study was made of the relation of brain blood flow and oxygen consumption to changes in perfusion flow rate during cardiopulmonary bypass at 20 degrees C in nine cynomolgus monkeys. Four perfusion flow rates varying from 0.25 to 1.75 L X min-1 X m-2 were randomly instituted, each for a 10 minute period. At the end of each period, brain arteriovenous oxygen content difference was measured and 15 mu radioactive microspheres were injected into the arterial perfusion line. The brain was then removed and section into anatomic regions and radioactivity was counted. Regional and total brain blood flows were calculated, as was whole brain oxygen consumption. Brain perfusion continued in all areas at all perfusion flow rates. Whole brain blood flow decreased (p less than 0.0001) as perfusion flow rate was reduced (45 +/- 6.5, 41 +/- 7.9, and 23 +/- 2.8 ml X min-1 X 100 gm-1 at 1.5, 1.0, and 0.5 L X min-1 X m-2, respectively). The proportion of the total perfusion delivered to the brain increased (p = 0.003) with decreasing perfusion flow rates (5.4% +/- 0.78%, 7.1% +/- 1.24%, and 8.2% +/- 1.11% at 1.5, 1.0, and 0.5 L X min-1 X m-2, respectively). Brain blood flow resistance remained unchanged (p = 0.4) while that of the remaining body increased (p less than 0.0001). There was a greater reduction of blood flow in the cortical white matter (p = 0.01) than in other regions of the brain. Brain oxygen consumption was the same (p = 0.5) at all perfusion flow rates, related to an increasing percent oxygen extraction with decreasing perfusion flow rate (p less than 0.0001). The data indicate that all areas of the brain remain perfused, even at low perfusion flow rates, during profoundly hypothermic cardiopulmonary bypass, and that brain oxygen consumption is maintained in part by increased oxygen extraction and in part by redistribution of the perfusate from the remaining body to the brain.

Animals↗