Use of fluorescent probes for determination of yeast cell viability by gravitational field-flow fractionation.

The quality of wine greatly depends on the features of the yeast used in its production, and yeast cell viability is one of the most important quality control issues to consider in this regard. In the first steps of winemaking, the use of a low-cost and simple methodology for monitoring the cell viability of yeast inoculates is of paramount importance. Gravitational field-flow fractionation is a useful technique for the determination of cell viability because it provides gentle experimental conditions, although the proper use of fluorophore probes as biomass indicators is required. In this paper the use of different fluorescent probes such as carboxyfluorescein diacetate (cFDA), calcein-AM, and SYTO-13 were considered as viability biomarkers. Calceina-AM allowed the establishment of a direct GrFFF method to determine cell viability, with a limit of detection of 5.0 x 10(4) viable cell/mL. SYTO-13 could be used as biomass indicator with a limit of detection of 3.5 x 10(4) total cells/mL. The suitability of the procedure was tested with three commercial yeast samples, and the results were compared with those obtained using standard techniques.

Calibration↗

Colloidal transport and agglomeration in column studies for advanced run-off filtration facilities--particle size and time resolved monitoring of effluents with flow-field-flow-fractionation.

The efficiency of road run-off filtration facilities based on ion-exchange materials is reduced by pollutants which are transported bound to particles. To quantify the factors governing particle transport phenomena, a simplified model consisting of quartz sand-filled columns representing the filter/soil was set up. Suspensions of artificial clays, cold water-extracted natural clays, and real run-off were used as model effluents. Five experiments were performed: breakthrough of a natural soil suspension, remobilization of a natural soil suspension after ionic strength-drop, the same two experiments with a suspension of the artificial clay mineral Laponite, and the remobilization of run-off accumulated on a column at high ionic strength with an ionic strength down-gradient. Short-interval effluent fractions were analysed by flow-field-flow-fractionation (F4) to obtain the size distributions of the colloids present. The size distributions of subsequent fractions were then plotted in a staggered arrangement to give three-dimensional graphs that are time- and particle size-resolved. With this method the subsequent release of different agglomerate sizes formed on the column could be shown for the artificial clay mineral, questioning its use as a model colloid. The combined particle size- and time-resolved plots proved to be a powerful tool for monitoring colloidal solids in column effluents.

Chromatography, Ion Exchange↗

Characterization of yeast cultivations by steric sedimentation field-flow fractionation.

The characterization and quantification of biomass is often time consuming and dependent on the cultivation media and gives no detailed information between cell size and shape and their productivity. By monitoring the bioprocess with steric sedimentation field-flow fractionation (Sd/StFFF) in combination with laser light scattering, not only cell growth, but also the variation of cell size and shape during the cultivation, can be observed. In this work, the feasibility of separating and characterizing cell populations by steric sedimentation field-flow fractionation is demonstrated by its application to three different yeast cultivation broths. For this purpose samples which were collected at different cultivation times were injected into an FFF system. Fractograms were obtained in less than 4 min. Due to the relatively high resolution of the method, a cell sample could be fractionated in several subpopulations differing in their size as well as in their number of buds.

Cell Separation↗

Sedimentation field flow fractionation purification of immature neural cells from a human tumor neuroblastoma cell line.

The use of stem cells for therapeutic applications is now an important objective for the future. Stem cell preparation is difficult and time-consuming depending on the origin of cells. Sedimentation field flow fractionation (SdFFF) is an effective tool for cell separation, respecting integrity and viability. We used the human neuroblastic SH-SY5Y clone of the SK-N-SH cell line as a source of immature neural cells. Our results demonstrated that by using SdFFF cell sorter under strictly defined conditions, and immunological cell characterization, we are now able to provide, in less than 15 min, a sterile, viable, usable and purified immature neural cell fraction without inducting cell differentiation.

Cell Line, Tumor↗

Micro-thermal field-flow fractionation: new high-performance method for particle size distribution analysis.

Micro-thermal field-flow fractionation (mu-TFFF) was applied to the separation of polystyrene latices. This new high-resolution technique allows determination of the particle size distribution (PSD) if carried out under optimized experimental conditions. The optimum temperature of the accumulation wall, which influences the relaxation processes and, consequently, the zone broadening, was chosen on the basis of our prior work. The flow rate was chosen as a compromise between the theoretical optimum value, which is very low because the diffusion coefficients of the colloidal particles are very small, and a value allowing performance of the PSD analysis in a reasonable time. These experimental conditions can be manipulated easily due to the high versatility of mu-TFFF, which follows from a large decrease of the heat energy flux across the channel with its reduced dimensions in comparison with standard TFFF. The PSDs obtained from mu-TFFF data are compared with results from quasi-elastic laser light scattering (QELS) and transmission electron microscopy (TEM). It has been found that a baseline resolution of a model mixture of two samples of close average particle diameters can be achieved by an appropriate choice of the temperature drop in mu-TFFF, whereas only a broad, unresolved PSD of the mixed sample was obtained from the QELS measurement. The TEM of the mixed sample revealed the presence of two particle size populations. However, the number of particles which are practically counted on a TEM picture is several orders of magnitude lower than the number of particles taken into account in mu-TFFF or QELS. Consequently, the PSD obtained from the TEM did not represent the whole sample. Comparison of mu-TFFF with modern hydrodynamic chromatography (HC) has shown that the methods exhibit roughly the same resolution and time of analysis. Nevertheless, mu-TFFF is a more universal technique because the separation of the colloidal particles or of the macromolecules within a broad range of molar masses is carried out on the same channel, as demonstrated previously.

Journal Article↗

Comparative study of human red blood cell analysis with three different field-flow fractionation systems.

An extensive multi-laboratory study was conducted to compare three different field-flow fractionation (FFF) systems for use in the analysis of human erythrocytes. The object of this study was to determine the relationship between the FFF elution properties for each system and the traditional hematological blood cell parameters. One centrifugal system (Utah) and two gravitational systems (Paris and Abbott) were compared. In order to analyze erythrocyte populations with a broad range of hematological indices, blood samples were collected from individuals heterozygous for sickle cell anemia (A/S) and also from normal controls (A/A), and these were analyzed at each site. Identical samples were analyzed by the Abbott and Utah sites. With all three systems, blood samples from each category produced narrow, overlapping distributions of FFF retention ratios, with the Abbott and Utah systems showing slight elevations in the mean retention ratios for the sickle cell samples. Blood cell elution peak characteristics were compared with standard hematological parameters for each of the FFF systems, and negative correlations were consistently found between mean corpuscular volume (MCV) and retention ratios. Positive correlations were found between red cell distribution width (RDW) and retention ratios. Elevated FFF retention ratios were frequently found with blood samples having abnormal hematological profiles. These results demonstrate that the three differently configured systems all produce similar analysis profiles for erythrocytes from the classes studied here. The relationships between FFF parameters and hematological indices were consistent for all systems.

Anemia, Sickle Cell↗

Size analysis of automobile soot particles using field-flow fractionation.

Soot particles emitted from various automobile engines are analyzed for size distributions using field-flow fractionation (FFF). Soot samples are prepared for FFF analysis using a three-step procedure, where a layer of soot particles is focused between the layers of n-hexane and water, followed by dispersing of particles in water containing 0.05% Triton X-100. The mean diameters determined by FFF show similar trends with those obtained from dynamic light scattering (DLS) and scanning electron microscopy (SEM). Data from FFF are also compared with those from an on-line scanning mobility particle sizer (SMPS). SMPS size distributions extend further to larger size than those of FFF distributions, which indicates the three-step sample preparation procedure effectively disaggregates the agglomerated particles. Although the amount of particulate matter (PM) emitted from a heavy-duty diesel engine is much higher than that from a light-duty diesel engine, the size distributions of soot particles show no significant difference between heavy- and light-duty diesel engines. The engine-operating mode (engine speed and load rate) does not seem to affect significantly the size distribution of soot particles. It was found that the PM from a turbocharged diesel engine contains a higher percentage of particles smaller than 100 nm than an engine with a naturally aspirated (NA) air-inhalation system. As for gasoline engines, the PM collected after the catalytic converter has a narrower size distribution than those collected before and has a higher percentage of particles smaller than 100 nm.

Air Pollution↗

Mouse embryonic stem cell sorting for the generation of transgenic mice by sedimentation field-flow fractionation.

Mouse embryonic stem (ES) cells are an important tool for generation of transgenic mice and genetically modified mice. A rapid and efficient separation of ES cells that respects cell integrity, viability, and their developmental potential while also allowing purified ES fraction collection under sterile conditions might be of great interest to facilitate the generation of chimeric animals. In this study, we demonstrated for the first time the effectiveness of a sedimentation field-flow fractionation (SdFFF) cell sorter to provide, with a characteristic DNA content, a purified ES cell fraction and with a high in vivo developmental potential to prepare transgenic mice by generation of chimeras having a high percentage of chimerism.

Animals↗

Megakaryocyte cell sorting from diosgenin-differentiated human erythroleukemia cells by sedimentation field-flow fractionation.

Anticancer differentiation therapy could be one strategy to stop cancer cell proliferation. Human erythroleukemia (HEL) cell line, incubated with 10 microM diosgenin, underwent megakaryocytic differentiation. Thus, the association diosgenin/HEL could be used as a model of chemically induced cellular differentiation and anticancer treatment. The goal of this work was to determine the capacity of sedimentation field-flow fractionation (SdFFF) to sort megakaryocytic differentiated cells. SdFFF cell sorting was associated with cellular characterization methods to calibrate specific elution profiles. As demonstrated by cell size measurement methods, cellular morphology, ploidy, and phenotype, we obtained an enriched, sterile, viable, and functional fraction of megakaryocytic cells. Thus, SdFFF is proposed as a routine method to prepare differentiated cells that will be further used to better understand the megakaryocytic differentiation process.

Cell Differentiation↗

Flow field-flow fractionation: new method for separating, purifying, and characterizing the diffusivity of viruses.

The nature and theory of flow field-flow fractionation is described, and its potential applicability to virus-like particles is discussed. Different virus types are shown to be retained at different levels. Retention can be controlled by variation of the experimental parameters, in good agreement with theory. However, a mild adsorption effect is indicated and requires the development of alternate strategies for measuring diffusion coefficients. For Qbeta, our value agrees well within 10% of literature values; the values obtained for other viruses, using Abeta as an internal standard, are untested. Finally, it is demonstrated that flow field-flow fractionation can cleanly fractionate two viruses from one another and from an albumin impurity, that samples as large as several milligrams in size can be analyzed, and that the method has potential utility in the quantitative and qualitative analysis of virus systems.

Albumins↗

Size- and density-dependent elution of normal and pathological red blood cells by gravitational field-flow fractionation.

Elution of normal and pathological human red blood cells (RBCs) was performed by gravitational field-flow fractionation (GFFF). The reproducibility of the retention factor was lower than 10% and elution at high and low flow-rates confirmed the existence of "lifting forces". No direct correlation between size and retention was observed for normal RBCs in the absence of density information. Elution of pathological human RBCs, known to be modified in shape, density and rigidity, was performed. The elution parameters confirmed that the retention mechanism of RBCs is at least density dependent but that other factors can be involved, such as shape or deformity. Moreover, peak profile description parameters (standard deviation and asymmetry) can be qualitatively related to some biophysical parameters. Numerous elution characteristics can be linked to cell properties described in the literature and although GFFF appeared to have limited capabilities in terms of size analysis it appeared to be a versatile tool for studying cell biophysical characteristics.

Anemia, Sickle Cell↗

Improved separation speed and efficiency for proteins, nucleic acids and viruses in asymmetrical flow field flow fractionation.

The performance of the asymmetrical flow field-flow fractionation channel has been improved by the use of a much thinner (0.12-mm) channel than before and by flow programming (stepwise gradient elution). The thinner channel contributes to a decreased zone broadening which enables complete resolution in a shorter time. Three protein peaks, representing molecular weights from 12,000 to 136,000, wer completely resolved within 3 min. Flow programming speeds up the elution of the high-molecular-weight materials which occur late in a fractogram. This enabled separation of a small plasmid fragment (700 base pairs) from the large amounts of a big fragment (4600 base pairs) in 30 min and improved detection of a presumed trimer of albumin. Two viruses (1.8 10(6) and 50 10(6) daltons) were eluted as narrow peaks within 5 min.

Chemical Fractionation↗

Numerical simulation of band-broadening during hydrodynamic relaxation in frit-inlet field-flow fractionation channels.

The frit-inlet technique is a promising implementation of hydrodynamic relaxation of samples in field-flow fractionation (FFF). The optimization of the process is of great importance in order to maximize overall system efficiency. The mechanism of band-broadening that takes place during hydrodynamic relaxation has been examined using a three-dimensional simulation of the flow inside the triangular end-piece of the channel. This is the first time this contribution to band-broadening has been considered and studied. Particle trajectories in the absence of a transverse field were numerically calculated, thereby isolating this effect from the familiar field-driven relaxation effect. As a first step towards an optimization of the system, the influence of the length of frit element was examined. Band-broadening was examined by determining the number of particles passing through the triangular end-piece as a function of transit time for a uniform particle distribution at the injection point. Due to the complexity of the flow patterns within the system, it is concluded that such numerical simulations are necessary for the optimization of the design and operation of this type of channel.

Algorithms↗

Size characterization of barley starch granules by gravitational field-flow fractionation: a rapid, low-cost method to assess the brewing capability of different strains.

Cereal starch occurs as two types of micrometer-sized granules, large and small. Large starch granules are more susceptible to enzymatic hydrolysis. When cereal starch is used for fermentation processes, as in brewing of barley malt, the barley strains with the highest content of large starch granules should be preferred. Gravitational field-flow fractionation (GFFF) is a separation method able to fractionate starch samples at low cost and short analysis time. In this work, the search for the best GFFF conditions for the analytical separation of barley starch within an inter-laboratory approach is presented. For different barley strains cultivated under monitored conditions the size distributions of starch granules is here quickly monitored and characterized by GFFF. As a consequence, dimensional characterization of barley starch can allow for the selection of the most suitable strains with the lowest content of non-degradable starch.

Fermentation↗

Differential analysis of human leukocytes by dielectrophoretic field-flow-fractionation.

The differential analysis of human leukocytes has many important biological and medical applications. In this work, dielectrophoretic field-flow-fractionation (DEP-FFF), a cell-separation technique that exploits the differences in the density and dielectric properties of cells, was used to separate the mixtures of the major human leukocyte subpopulations (T- and B-lymphocytes, monocytes, and granulocytes). The separation was conducted in a thin chamber equipped with an array of microfabricated interdigitated electrodes on the bottom surface, and the separation performance was characterized by on-line flow cytometry. To investigate optimal separation conditions for different leukocyte mixtures, elution fractograms at various DEP field frequencies were obtained for each leukocyte subtype. With appropriately chosen conditions, high separation performance was achieved in separating T- (or B-) lymphocytes from monocytes, T- (or B-) lymphocytes from granulocytes, and monocytes from granulocytes. DEP-FFF does not involve cell-labeling or cell-modification step, and provides a new approach to hematological analysis.

B-Lymphocytes↗

Sedimentation field-flow fractionation application to Toxoplasma gondii separation and purification.

Toxoplasmosis is a worldwide disease caused by Toxoplasma gondii, an intracellular protozoa of micronic size range (4-10 microm). Its classical purification processes are complex and often associated with low recovery. All investigation procedures concerning this parasite require its isolation and purification from at least the mouse ascitic fluid. For this purpose, a recently developed laboratory technology was used, i.e. sedimentation field-flow fractionation. This chromatographic-like separation technology was demonstrated to be particularly selective for isolation and separation of micron-sized biological particles. Sedimentation field-flow fractionation operated on the steric-hyperlayer mode was used to isolate the parasite from the remanent ascitic contaminants of different origins and from red blood cells. With this technology, 86% recovery with 97% viability was obtained in less than 30 min.

Animals↗

Rapid breakthrough measurement of void volume for field-flow fractionation channels.

A peak breakthrough technique is described and evaluated for measuring the void volume of field-flow fractionation (FFF) channels, particularly those used for flow FFF. This technique uses a high-molecular-mass macromolecular or particulate probe that can be displaced rapidly by flow through the FFF channel with minimal transverse diffusion. The particles that emerge first are those carried through the entire length near the channel centerline at the apex of the parabolic flow profile. These particles generate a sharp breakthrough profile. The measured breakthrough time is two thirds of the void time, thus making it possible to calculate both the void time and the associated void volume. This method, although applicable to all FFF channels (and capable of extension to open tubes), is particularly useful for flow FFF because conventional low-molecular-mass void probes can diffuse into the permeable walls and thus distort void measurements. The theoretical basis of the breakthrough technique and an explanation for the sharpness of the breakthrough front are given. A method for compensating for deviations from perfect sharpness is developed in which the breakthrough time is identified with the time needed to reach 85-88% of the breakthrough peak maximum. Preliminary experimental results are shown using various protein probes in four different FFF channel systems.

Chemical Fractionation↗

Characterization of winemaking yeast by cell number-size distribution analysis through flow field-flow fractionation with multi-wavelength turbidimetric detection.

Yeasts are widely used in several areas of food industry, e.g. baking, beer brewing, and wine production. Interest in new analytical methods for quality control and characterization of yeast cells is thus increasing. The biophysical properties of yeast cells, among which cell size, are related to yeast cell capabilities to produce primary and secondary metabolites during the fermentation process. Biophysical properties of winemaking yeast strains can be screened by field-flow fractionation (FFF). In this work we present the use of flow FFF (FlFFF) with turbidimetric multi-wavelength detection for the number-size distribution analysis of different commercial winemaking yeast varieties. The use of a diode-array detector allows to apply to dispersed samples like yeast cells the recently developed method for number-size (or mass-size) analysis in flow-assisted separation techniques. Results for six commercial winemaking yeast strains are compared with data obtained by a standard method for cell sizing (Coulter counter). The method here proposed gives, at short analysis time, accurate information on the number of cells of a given size, and information on the total number of cells.

Fractionation, Field Flow↗