Severe hypoxaemia in field-anaesthetised white rhinoceros (Ceratotherium simum) and effects of using tracheal insufflation of oxygen.

White rhinoceros anaesthetised with etorphine and azaperone combination develop adverse physiological changes including hypoxia, hypercapnia, acidosis, tachycardia and hypertension. These changes are more marked in field-anaesthetised rhinoceros. This study was designed to develop a technique to improve safety for field-anaesthetised white rhinoceros by tracheal intubation and oxygen insufflation. Twenty-five free-ranging white rhinoceros were anaesthetised with an etorphine and azaperone combination for translocation or placing microchips in their horns. Once anaesthetised the rhinoceros were monitored prior to crating for transportation or during microchip placement. Physiological measurements included heart and respiratory rate, blood pressure and arterial blood gas samples. Eighteen rhinoceros were intubated using an equine nasogastric tube passed nasally into the trachea and monitored before and after tracheal insufflation with oxygen. Seven rhinoceros were not intubated or insufflated with oxygen and served as controls. All anaesthetised rhinoceros were initially hypoxaemic (percentage arterial haemoglobin oxygen saturation (%O2Sa) = 49% +/- 16 (mean +/- SD) and PaO2 = 4.666 +/- 1.200 kPa (35 +/- 9 mm Hg)), hypercapnic (PaCO2 = 8.265 +/- 1.600 kPa (62 +/- 12 mm Hg)) and acidaemic (pHa = 7.171 +/- 0.073 ). Base excess was -6.7 +/- 3.9 mmol/l, indicating a mild to moderate metabolic acidosis. The rhinoceros were also hypertensive (systolic blood pressure = 21.861 +/- 5.465 kPa (164 +/- 41 mm Hg)) and tachycardic (HR = 107 +/- 31/min). Following nasal tracheal intubation and insufflation, the %O2Sa and PaO2 increased while blood pHa and PaCO2 remained unchanged. Tracheal intubation via the nose is not difficult, and when oxygen is insufflated, the PaO2 and the %O2Sa increases, markedly improving the safety of anaesthesia, but this technique does not correct the hypercapnoea or acidosis. After regaining their feet following reversal of the anaesthesia, the animals' blood gas values return towards normality.

Acid-Base Equilibrium↗

Endoscopic saphenectomy for coronary artery bypass surgery: comparison of two techniques with and without carbon dioxide insufflation.

OBJECTIVE: To compare the clinical results of an initial experience with two techniques of endoscopic saphenectomy with and without gas insufflation. DESIGN: A retrospective study was performed between September 1998 and March 1999 on 40 patients who underwent endoscopic saphenectomy for coronary artery bypass graft without (group 1, n=15) and with (group 2, n=25) carbon dioxide insufflation. INTERVENTIONS: In both groups, the site of harvesting was at the knee through a 2 cm incision. In group 1, dissection was performed using a hand-held dissector while in group 2 dissection was performed after ensuring that there was a seal at the knee and insufflation of carbon dioxide. Collaterals were controlled with an endoclipper in group 1 and bipolar scissors in group 2. Intraoperative procedure time, length of the harvested vein and aspect of the thigh (ecchymosis, hematoma, infection) were recorded. RESULTS: Vein trauma occurred in four patients in group 1 (four of 15, 27%) and in one in group 2 (one of 25, 4%). Hematomas developed in four patients in group 1 (four of 15, 27%) and in one patient in group 2 (one of 25, 4%). Wound infection occurred in no patients in group 1 and in one patient in group 2. One patient in group 2 suffered carbon dioxide embolism with no untoward consequences. Conversion to an open technique was necessary in five patients in group 1 (five of 15, 33%) and in two patients in group 2 (two of 25, 8%). CONCLUSIONS: Endoscopic saphenectomy both with and without carbon dioxide insufflation is associated with a low infection rate, but vein trauma and wound hematomas are more common without carbon dioxide insufflation.

Angioscopes↗

[Changes in the number of immunocompetant cerebrospinal fluid cells in epileptic patients following air insufflation into the subarachnoid space].

In 10 patients with various forms of epilepsy the effect of air insufflation into the subarachnoidal space on the number of immunocompetent cells in the cerebrospinal liquor and the peripheral blood was studied. A sharp rise of the percentage of the T- and B-lymphocytes in the cerebrospinal liquor was noted as a result of the insufflation. Examinations of the blood before the insufflation and in the presence of the pronounced post-insufflation meningeal syndrome did not reveal any distinct regularity. A direct relationship between the liquor immune reaction and the intensity of the post-insufflation meningeal syndrome was noted.

Adolescent↗

[The technique of arthroscopy with nitrous oxide insufflation (author's transl)].

Since April 1977 we have carried out more than 250 arthroscopies using a nitrous oxide insufflation device. Nitrous oxide is completely non-toxic to the tissues and is rapidly absorbed. Unlike carbon dioxide, which is the other commonly used insufflation gas, nitrous oxide does not combine with water to form an acid which can irritate the tissues. Furthermore, it is more rapidly absorbed than air. The normal insufflation pressure of 50 mm Hg is usually sufficient to expand the soft parts of the knee joint to the required degree. Interstitial nitrous oxide emphysema occurred in only 7 cases; it was of limited degree in each case and attributable to initial technical difficulties with the apparatus, selection of an excessive insufflation pressure, or additional stab incision. The nitrous oxide emphysema was always asymptomatic and, in some cases, was not even noticed by the patient. No infections of the knee joint or other serious complication followed insufflation with this device, which incorporated a bacterial filter.

Emphysema↗

Double-blind, prospective, randomized study of warmed, humidified carbon dioxide insufflation vs standard carbon dioxide for patients undergoing laparoscopic cholecystectomy.

HYPOTHESIS: Patients undergoing warmed, humidified carbon dioxide (CO2) insufflation for laparoscopic cholecystectomy will (1) maintain a warmer intraoperative core temperature, (2) have their surgeon experience less fogging of the camera lens, and (3) have less postoperative pain than patients undergoing laparoscopic cholecystectomy with standard CO2 insufflation. DESIGN: A double-blind, prospective, randomized study comparing patients undergoing laparoscopic cholecystectomy with standard CO2 insufflation vs those receiving warmed, humidified CO2 (Insuflow Filter Heater Hydrator; Lexion Medical, St Paul, Minn) was performed. Main variables included patient core temperature, postoperative pain, analgesic requirements, and camera lens fogging. RESULTS: One hundred one blinded patients (69 women, 32 men) undergoing laparoscopic cholecystectomy were randomized into 2 groups-52 receiving standard CO2 insufflation (group A) and 49 receiving warmed, humidified CO2 (group B). Mean patient intraoperative core temperature change (group A decreased by 0.03 degrees C, group B increased by 0.29 degrees C, P =.01) and mean abdominal pain (Likert scale, 0-10) at 14 days postoperatively (group A, 1.0; group B, 0.3; P =.02) were different. Other variables (camera lens fogging, early postoperative pain, narcotic requirements, recovery room stay, and return to normal activities) between groups were similar. CONCLUSION: While patients undergoing laparoscopic cholecystectomy with warmed, humidified CO2 had several advantages that were statistically significant, no major clinically relevant differences between groups A and B were evident.

Carbon Dioxide↗

CO2 abdominal insufflation pretreatment increases survival after a lipopolysaccharide-contaminated laparotomy.

Carbon dioxide (CO(2))-pneumoperitoneum is known to favorably modify the systemic immune response during laparoscopic surgery. The presented studies were designed to determine whether treating animals with CO(2) abdominal insufflation before undergoing a lipopolysaccharide (LPS)-contaminated laparotomy would serve as "shock prophylaxis" and thus improve survival and attenuate cytokine production. Rats were randomized into five groups: CO(2)-pneumoperitoneum, helium-pneumoperitoneum, anesthesia control, laparotomy/LPS control, and LPS only control. Animals in the first four groups all received a laparotomy and a lethal dose of LPS. Immediately preceding their laparotomy, animals in the pneumoperitoneum groups received a 30-minute pretreatment of abdominal insufflation with either CO(2) or helium. The anesthesia control group received a 30-minute pretreatment of isoflurane. Animal mortality was then recorded during the ensuing 72 hours. Subsequently, a similar protocol was repeated for measurements of cytokines. CO(2)-pneumoperitoneum increased survival at 48 hours compared with LPS control (P <.05), and decreased interleukin-6 plasma levels at 2 hours (P <.05). Abdominal insufflation with CO(2) before the performance of a laparotomy contaminated with endotoxin increases survival and attenuates interleukin-6. The beneficial immune-modulating effects of CO(2)-pneumoperitoneum endure after abdominal insufflation. CO(2)-pneumoperitoneum pretreatment may improve outcomes among patients undergoing gastrointestinal surgery who are at high risk for abdominal fecal contamination.

Anesthesia, Inhalation↗

The real intraabdominal pressure during laparoscopy: comparison of different insufflators.

STUDY OBJECTIVE: To compare 5 laparoscopic insufflators with different gas flow rates with regard to accuracy of preset pressure setting versus real intraoperative intraabdominal pressure. DESIGN: Prospective study (Canadian Task Force classification II-2). SETTING: Fayette Medical Center, Alabama. PATIENTS: Five patients undergoing laparoscopic cholecystectomy. INTERVENTIONS: Intraoperative intraabdominal and system pressure measurements during comparable laparoscopic procedures. MEASUREMENTS AND MAIN RESULTS: Actual intraabdominal pressure was measured and compared between 5 different 10 to 20 L/min insufflators (Storz Laparoflator and Endoflator, Richard Wolf, BEI Medical and Snowden & Pencer) with a computer-based online data acquisition system. At a nominal pressure of 10 mm Hg, the mean intraabdominal pressure during the entire procedure was measured to be between 9.68 and 11.45 mm Hg. The mean intraabdominal pressure during laparoscopy for the insufflators showed a margin of error of 14.5%, with maximum intraabdominal pressure peaks measured between 14.65 and 17.87 mm Hg. CONCLUSIONS: Within an error margin of <15% of the preset intraabdominal pressure setting, the insufflators evaluated can be considered pressure reliable. Although intraabdominal pressure peaks exceeding the nominal pressure temporarily reached up to 78.7% of the setting, no apparent complications were observed. Excessive pressure peaks seen in the previous reported laboratory model could not be confirmed during in vivo application.

Abdominal Cavity↗

Amniotic air insufflation during minimally invasive fetoscopic fetal cardiac interventions is safe for the fetal brain in sheep.

BACKGROUND: Amniotic air insufflation during experimental fetoscopic fetal cardiac interventions greatly improves the visualization of intra-amniotic contents. The purpose of this study was to assess any histologically discernible effects from this approach on the fetal brain after short-term studies and long-term survival in sheep. METHODS: Thirty pregnant ewes between 80 and 110 days of gestation underwent amniotic air insufflation during various fetoscopic fetal cardiac interventions. After 18 short-term and 12 long-term studies, the brains of the operated fetuses and-if available-their unoperated siblings were examined for hemorrhage, embolism, infarctions, inflammatory changes, and abnormal cortical maturation. RESULTS: Amniotic air insufflation during minimally invasive fetoscopic fetal cardiac interventions did not result in any histologically discernible damage to the brain in short-term and long-term studies in any but 2 sibling sheep. In the 2 affected siblings, a small area of chronic cortical frontal lobe infarction was observed after long-term survival. CONCLUSIONS: Amniotic air insufflation during minimally invasive percutaneous fetoscopic fetal cardiac interventions is safe for the fetal brain and does not compromise maternal hemodynamics in sheep. These findings encourage further investigation of the role this technique might play during fetoscopic fetal cardiac interventions in humans.

Amnion↗

Hemodynamic effects of carbon dioxide insufflation during endoscopic vein harvesting.

BACKGROUND: A prospective study was performed assessing the hemodynamic effects of carbon dioxide (CO2) insufflation during endoscopic vein harvesting (EVH) using the Guidant Vasoview Uniport system. METHODS: Five hemodynamic and respiratory parameters (end-tidal carbon dioxide, arterial partial pressure of carbon dioxide, mean arterial pressure, mean pulmonary arterial pressure, and cardiac output), were measured in 100 consecutive patients undergoing EVH with CO2 insufflation. Data were obtained prior to commencement of EVH, 15 minutes after commencement, and 5 minutes after completion of the vein harvesting. RESULTS: No adverse hemodynamic effects were observed during CO2 insufflation. Specifically, average mean arterial pressure went from 88.77+/-9.64 to 89.13+/-8.60 to 88.24+/-8.71 mm Hg before, during, and after endoscopic vein harvesting (p = 0.291). Likewise, average mean pulmonary artery pressures were 19.76+/-4.75, 20.05+/-4.48, and 20.05+/-4.62 mm Hg (p = 0.547); and average cardiac output was 4.25+/-0.74, 4.22+/-0.73, and 4.23+/-0.69 L/min (p = 0.109) at those three intervals. Additionally, there was no evidence of significant systemic absorption of CO2 as reflected in average arterial PCO2, which remained steady at 37.42+/-5.19, 37.51+/-4.59, and 38.10+/-4.80 mm Hg (p = 0.217); and average end-tidal CO2, which was 32.10+/-3.66, 32.50+/-3.47, and 32.38+/-3.33 mm Hg (p = 0.335). In a subset of 20 patients with elevated pulmonary arterial pressure (more than 32 mm Hg), there was also no significant change in any of the parameters. CONCLUSIONS: Carbon dioxide insufflation during EVH leads to no adverse hemodynamic consequences or systemic CO2 absorption. The technique appears to be safe and well tolerated.

Aged↗

High-flow gas insufflation to facilitate MIDCABG: effects on coronary endothelium.

BACKGROUND: During less invasive coronary bypass operations on the beating heart, as well as conventional operations using continuous warm cardioplegia, a precise anastomosis is facilitated by a bloodless field. To maintain a clear field, many surgeons use high-flow gas insufflation. However, the potentially damaging effects of gas insufflation on coronary endothelium have not been elucidated. METHODS: Seven pigs underwent median sternotomy. Between two coronary occluders, an arteriotomy in the mid left anterior descending coronary artery (LAD) was performed. In the experimental group (n = 5), the operative field was kept clear by exposing the arteriotomy to a catheter-directed stream of carbon dioxide at 15 L/min. In the control group (n = 2), the arteriotomy was left open to room air. After 20 minutes, the segments of LAD exposed to carbon dioxide or room air, and the unexposed proximal LAD and right coronary artery, were processed, sectioned, and stained together. A murine anti-human tie-2 monoclonal antibody was used to identify endothelium. RESULTS: All unexposed LAD and right coronary artery segments and all LAD segments exposed only to room air demonstrated normal, contiguous staining of endothelium with the murine anti-human tie-2 monoclonal antibody. In contrast, all LAD segments exposed to high-flow carbon dioxide gas insufflation demonstrated near-complete loss of endothelium. CONCLUSIONS: These data demonstrate that high-flow carbon dioxide gas insufflation denudes the coronary artery of its endothelium. This exposes blood elements to the subendothelium and promotes clotting, and endothelial loss may promote smooth muscle cell migration and proliferation. These events set the stage for early and late graft failure.

Animals↗

Efficacy of several modes of continuous-flow insufflation for resuscitation of a canine model of acute respiratory arrest.

STUDY OBJECTIVE: To test the efficacy of several modes of continuous-flow insufflation on the maintenance of physiologic parameters in a model of respiratory arrest, and the effect of these modes on neurologic outcome. METHODS: Anesthetized dogs were slowly infused with tetrodotoxin over 75 minutes to the point of respiratory arrest. We used two different modes of continuous-flow insufflation: endobronchial insufflation (EI) of air 3 cm distal to the carina (.25 or 1.0 L.kg-1.min-1); and tracheal insufflation of oxygen (TRIO) 1 cm proximal to the carina (.08 or .2 L.kg-1.min-1). RESULTS: EI at either flow rate provided ventilation sufficient to allow the dogs to recover effective spontaneous breathing and be removed from ventilation after 4 hours. By this time, almost all cardiovascular variables and blood gas values were normal. TRIO at .2 L.kg-1.min-1 also resulted in successful recovery, although Pa02, as well as systemic and pulmonary arterial pressures and vascular resistances, remained increased at the end of the 4-hour period. TRIO at the low flow rate, however, resulted in deterioration of blood gas values and systemic arterial pressure; dogs required conventional mechanical ventilation after 45 minutes of low-flow TRIO. CONCLUSION: EI can be used to maintain oxygenation in acute respiratory arrest when conventional techniques are not feasible; TRIO at .2 L.kg-1.min-1 is also effective.

Acute Disease↗

Twenty-five simple ways to increase insufflation performance and patient safety in laparoscopy.

Technical aspects of laparoscopic insufflation technique and interaction among patient, technique, and physician can affect the performance of laparoscopy and patient safety. A variety of laparoscopic equipment was evaluated regarding insufflation performance in laboratory measurements and/or in an intraoperative computer-based data-acquisition model for intraabdominal pressure, gas flow, and temperature. In this article, we present 25 suggestions for improving insufflation performance and increasing patient safety. These tips may help avoid and solve insufflation problems and malfunction, over- and under-pressure peaks, laparoscopic hypothermia, and gas embolism, and shorten operation room and anesthesia time, thereby saving time, money, and physician stress.

Female↗

Delivery of nasal powders of beta-cyclodextrin by insufflation.

PURPOSE: Delivery of nasal powders of granulated beta-cyclodextrin by insufflation was studied in order to find the relationship between powder properties and delivery behavior. METHODS: Three nasal powder formulations, prepared by granulating beta-cyclodextrin with different binders, were delivered from a powder insufflation device, in which the dose to be emitted was loaded in a gelatin capsule. The delivery sequence of powder was recorded and characterized using an image analysis program. RESULTS: Particle size was the main parameter affecting nasal powder delivery, both as to the amount of dose sprayed and the aspect of cloud produced. Between 50-150 mu m of particle size a substantial change in delivery behavior of powders was observed. Powder of around 100 mu m in size showed useful insufflation characteristics for nasal delivery. Bioavailability of nasal formulations of progesterone/beta-cyclodextrin powders was discussed in term of delivery behavior. CONCLUSIONS: The formulation approaches for improving nasal delivery of powders require the use of size optimized carriers. Insufflation of powders over 50 mu m can favour the particle deposition by impaction, whereas for powders below 50 mu m, deposition by sedimentation is moved. beta-cyclodextrin is a suitable carrier for achieving high systemic availability following nasal administration of powder formulations.

Administration, Intranasal↗

Wound metastasis after laparoscopy with different insufflation gases.

BACKGROUND: There is growing evidence that laparoscopy for malignancy is associated with an increased incidence of metastasis to port sites. This study investigated the effect of different insufflation gases on port-site metastasis after laparoscopy in an established animal model. METHODS: Forty-eight Dark Agouti rats with an established adenocarcinoma in the left flank underwent laparoscopic intraperitoneal tumor laceration. The gas used for insufflation was one of the following (12 rats in each group): (1) CO2, (2) N2O, (3) helium, or (4) air. Rats were killed 7 days after the procedure, and the port sites were examined for the presence of tumor metastasis. RESULTS: Tumor involvement of port sites was significantly less likely after helium insufflation than in the other groups (p < 0.0001). There was no significant difference between the air, CO2, and N2O groups. CONCLUSIONS: This study suggests that the development of metastases in port sites after laparoscopy may be influenced in part by the choice of insufflation gas used to create the pneumoperitoneum. In particular, helium was associated with a reduced rate of metastases.

Adenocarcinoma↗

Renal effects of carbon dioxide insufflation in rabbit pneumoretroperitoneum model.

To determine the effects of carbon dioxide insufflation on renal function in a pneumoretroperitoneum model, 24 adult New Zealand rabbits were divided into four groups, six rabbits in each. The first group underwent a 2-hour CO2 insufflation at a pressure of 10 mm Hg in the retroperitoneal space after balloon dissection. In another group, the same procedure was maintained for 4 hours. In the sham-treated groups, the procedure was similarly carried out but without CO2 insufflation. In all four groups, serum and urine creatinine concentrations and renal artery and renal vein blood flow rates were determined separately at the beginning and at the end of the procedure and at 24 hours. Urine output was also recorded at the end of the procedure and at 24 hours. The serum creatinine in the 2- and 4-hour study groups had increased significantly at the end of the procedure, accompanied by a significant decrease in the urine creatinine value. Renal artery and renal vein blood flow rates and urine output were reduced in both groups during the study. All changes in the serum and urine creatinine, renal artery and vein flow rates, and urine output was more pronounced in the 4-hour group. All measures returned to their prestudy values by 24 hours. Pneumoretroperitoneum causes reversible renal dysfunction, which becomes more pronounced with prolonged insufflation. Further research is needed to show the impact of our findings in high-risk patients undergoing retroperitoneoscopic surgery.

Animals↗

Cricoid pressure applied after placement of the laryngeal mask prevents gastric insufflation but inhibits ventilation.

We studied 50 patients, in a blind, crossover study, to assess if cricoid pressure applied after placement of the laryngeal mask prevented gastric insufflation without affecting ventilation. After induction of anaesthesia and neuromuscular block, a laryngeal mask was inserted and confirmed to be placed correctly. The lungs were ventilated with a maximum inflation pressure of 15 cm H2O. In the first 25 patients, expiratory volumes were measured with and without cricoid pressure (30 N). On both occasions, a free hand was placed under the patient's neck. In the next 25 patients, the effect of cricoid pressure on ventilation without support of the neck was also studied. The effect of cricoid pressure with support of the neck on gastric insufflation was then assessed using a stethoscope in all 50 patients, while the lungs were ventilated with a maximum inflation pressure of 30 cm H2O. At the end of the study, the position of the mask was re-assessed. Cricoid pressure significantly decreased mean expiratory volume (P << 0.001). This inhibitory effect was significantly greater when the pressure was applied without support of the neck (P << 0.001). Cricoid pressure significantly reduced the incidence of gastric insufflation (12 patients vs one patient; P << 0.001; 95% CI for difference 10.5-33.5%). In no patient was the mask dislodged after these procedures. Thus, although cricoid pressure applied after insertion of the laryngeal mask prevented gastric insufflation, it also decreased ventilation. The inhibitory effect of cricoid pressure on ventilation without support of the neck was greater than cricoid pressure with support of the neck.

Adolescent↗

Intermittent or continuous carbon dioxide insufflation for de-airing of the cardiothoracic wound cavity? An experimental study with a new gas-diffuser.

Insufflation of carbon dioxide into the chest wound is used in open-heart surgery to de-air the heart and great vessels. In a cardiothoracic wound model, we compared the degree of air displacement achieved by a new insufflation device, a gas-diffuser, with that of a thin open-ended tube during steady-state and with carbon dioxide flows of 2.5, 5, 7.5, and 10 L/min. We also studied air displacement at the start of and after discontinuation of carbon dioxide insufflation with the gas-diffuser and evaluated the influence of an open pleura. During steady state, the gas-diffuser produced efficient air displacement in the wound cavity model at carbon dioxide flows of > or = 5 L/min (< or = 0.65% remaining air), whereas the open-ended tube was inefficient (> or = 82% remaining air) at all studied carbon dioxide flows (P < 0.001). An open pleural cavity prolonged the time needed to obtain a high degree of air displacement in the wound cavity (P = 0.001). Carbon dioxide insufflation of the cardiothoracic wound cavity should be initiated at a carbon dioxide flow of 10 L/min at least 1 min before the incision of the heart and great vessels and should be continued at a carbon dioxide flow of at least 5 L/min until surgical closure.

Air Pressure↗

Insufflated halothane increases venous admixture less than nitroprusside in canine atelectasis.

Although it generally is agreed that halothane is a pulmonary vasodilator, its effect on venous admixture and hypoxic pulmonary vasoconstriction are more controversial. The effects of 2.4% halothane on pulmonary vascular resistance and venous admixture were investigated in an isolated canine lobe made atelectatic. Halothane was administered by three different methods: insufflation, addition to the pulmonary artery blood through a bubble deoxygenator, or a combination of both techniques. Pulmonary vascular resistance was divided into arterial, venous, and middle segmental resistance by a vascular occlusion technique. Middle resistance increased with 3% O2 ventilation (0.0238 +/- 0.0092 cmH2O.ml-1.min-1) or after production of atelectasis (0.0225 +/- 0.0074 cmH2O.ml-1.min-1), compared to control ventilation in the nonatelectatic lung 0.01 +/- 0.0067 cmH2O.ml-1.min-1). Halothane by any delivery method variably decreased middle resistance, with increasing potency from addition of halothane through the bubble deoxygenator (0.0118 +/- 0.0047 cmH2O.ml-1.min-1) to halothane insufflation (0.0072 +/- 0.0058 cmH2O.ml-1.min-1), and finally to a combination of both techniques (0.0026 +/- 0.0041 cmH2O.ml-1.min-1). In contrast to vascular resistance, venous admixture in the atelectatic (8 +/- 5%) and nonatelectatic lobes (7 +/- 4%) was increased with halothane insufflation (11 +/- 4%), addition of halothane through the bubble deoxygenator (26 +/- 16%), and a combination of both techniques (22 +/- 13%). Compared to intravenous nitroprusside (26 +/- 12%), halothane insufflation was less potent in increasing venous admixture when total pulmonary vascular resistances were of similar magnitude (0.0526 +/- 0.0112 and 0.0484 +/- 0.0088 cmH2O.ml-1.min-1, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗