PubMed HealthSearch

SEARCH · PubMed Health

Results for “Method Acceptability”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

[Role of lymphography in determining a lymph flow blockage and the level of lympholymphatic shunting in edema of the extremities].

Different lymphographic methods were used for determining the disturbances of the lymph flow and the levels of the lympho-lymphatic shunts in 139 patients having edema of the upper (70) and lower (69) extremities. A conclusion is made that the generally accepted method of lymphography by means of the administration of a contrast substance into the vessels of one collector in some cases can not reveal the first symptoms of partial block of the lymph flow in clinical manifestation of edema. The successive lymphography of several collectors is necessary. With its aid the author has found that under normal conditions and in mild edemas they fulfil drainage separately, and in the expanded zone of edema they compensate the activity of one another.

Adolescent

An investigation of factors influencing the measurement of creatine phosphokinase activity in serum using coupled enzymatic methods.

1. The factors influencing the measurement of creatine phosphokinase (CPK) activity in serum by coupled enzymatic methods were investigated to establish optimum conditions for this type of assay. Such a study was indicated following observations by the authors of poor performance of commerically produced reagent kits together with the failure of most of the established an well accepted methods to operate under true optimum zero order kinetics in the reaction phase state. 2. The factors invested were the effects of pH, substrate concentrations (creatine phosphate, glucose and NADP+), added auxiliary (hexokinase) and indicator (glucose-6-phosphate dehydrogenase) enzymes, dithiothreitol (DTT) as an activator and conditions of storage of substrate stability. DTT was found to be a suitable activator but not a reactivator of the reaction. The optimum concentrations of creatine phosphate, glucose and NADP+ were found to be 20.0, 20.0 and 2.0 mmol/litre, respectively. Optimum activieies of the enzymes, glucose-6-phosphate dehydrosenase and hexokinase were 1000 and 2000 units/litre, respectively. 3. The between-day precision of the method for measuring serum at pH 6.8 and 30 degrees C at three activity levels under the optimum conditions developed was excellent yielding coefficients of variation ranging from 2.0 to 2.7%.

Creatine Kinase

Diabetic home blood glucose monitoring using a direct reading glucose sensitive test strip.

The aim of this study was to assess the performance of the BM Test Glycemie 20-800. Twelve diabetic patients were studied using the BM Test Glycemie 20-800, compared with one of the commonly available reflectance meters. The correlation coefficient for the BM 20-800 strip versus reference blood glucose result was significantly better than the reflectance meter (p = 0.01). In a separate study, laboratory staff tested both methods and achieved results which were similar to those of the patients using the BM Test Glycemie 20-800, but better than those of the patients using the reflectance meters. The BM Test Glycemie 20-800 is a cheap, reliable and acceptable method for the measurement of blood glucose levels.

Adolescent

Tests alternative to the rabbit bioassay for pyrogens.

The rabbit bioassay is currently the only legally acceptable method to test for pyrogenic contamination of parenteral preparations and medical devices designed to enter the parenterum. However, research efforts have recently made available alternative procedures to test for pyrogens which may have significant value in quality control. Part of the reluctance to accept tests other than the rabbit test may be due to the low visibility of emerging understanding of a significant theory of testing in which it is contended that the parameters of sensitivity and specificity are inversely related and that accuracy is an ideal. The rabbit pyrogen assay will detect 1 to 10 ng of enterobacteriaceal endotoxin (ET). The limulus test will detect 0.01 to 0.1 ng/ml of ET; some of the other tests approach the rabbit assay in sensitivity. Since it is current dogma that pyrogen is equivalent to ET, the basis for the use of ET to standardize pyrogen tests is rationalized. The source of ET in practice is bacterial contamination; therefore, numbers of bacteria that contaminate parenteral preparations can be directly related to potential pyrogenicity. Further, viable counts of bacteria in parenteral preparations, prior to sterilization, is a reliable test for pyrogens. Other tests such as nitroblue tetrazolium reduction and actinomycin-D enhancement of lethality of pyrogen for mice deserve consideration in quality control procedures. The limulus test, the most practical of currently available alternative tests for detection of ET and therefore, of pyrogen has application where the rabbit test cannot be used. Therefore, control personnel must learn of the availability, performance and interpretation of the limulus test. Practical considerations must govern the choice of an alternative test when the use of a test other than the rabbit bioassay is indicated.

Animals

Traumatic colonic perforation. Review of 16 years' experience.

The surgical management of colon injuries in civilian practice requires individualization. Primary repair, either by debridement and suture or resection and anastomosis, is a safe method of management in selected cases and results in a shorter hospital stay, less morbidity and a complication rate that is no higher. In this series, over half of the colon injuries were managed in this way. Exteriorization and proximal colostomy are accepted methods of management, but possibly should be reserved for the more severely injured patient. The criteria for individualization are briefly summarized.

Adult

Comparison of radiometric and microbiological assays for the determination of folate in fortified gruel and porridge.

The results obtained by a radiometric assay of folate in fortified gruel and porridge, using a commercially available radioassay kit, were compared with those obtained by a standard microbiological assay with Lactobacillus casei. A lower level of folate was found with the radiometric assay. Comparison of the results obtained with the two methods gave a correlation coefficient of 0.991 when the analysis was performed on samples extracted at the same time. A lower correlation coefficient was obtained between the result if the extractions were carried out on different occasions. The radiometric assay is a acceptable method for the routine determination of folate in fortified gruel and porridge.

Edible Grain

Assessment of myocardial perfusion by magnetic resonance imaging.

Magnetic resonance imaging (MRI) has proven useful for anatomic and functional evaluation of the heart. However, until recently assessment of myocardial perfusion has not been possible by MRI. Using newly developed ultrafast imaging sequences, images can be acquired rapidly with a high temporal resolution, which is a prerequisite for imaging the initial passage of a bolus of MR-contrast medium through the myocardium. Only gadolinium chelates, which rapidly diffuse out of vascular space, are currently approved for clinical use. The first pass of a bolus of one of these agents through hypoperfused myocardium distal to a coronary artery stenosis enhances this area less as compared to normally perfused areas. This different myocardial enhancement is often visible when looking at the series of MR images. However, intensity differences are rapidly decreasing as MR-contrast media are diluted in the systemio circulation after the first pass and diffuse to the interstitium. Therefore, only the first pass is of interest for MR-perfusion imaging. Additional and often more precise information can be derived by measuring parameters of the signal intensity time curve such as mean transit time, maximum signal intensity increase, upslope, downslope, and delay before reaching maximum signal intensity. Temporal resolution is the crucial factor in MR-perfusion imaging because it takes only 20 to 60 seconds for the contrast medium to pass through the myocardium. Therefore, this dynamic process must be imaged with a high temporal resolution. Moreover, image acquisition must be fast enough to minimize motion artefacts and to maximize the spatial coverage of the ventricle. Ultrafast gradient echo techniques and echo planar imaging are in principle capable to fulfill these demands. While ultrafast gradient echo sequences enable one to acquire a maximum of 2 slices per heartbeat, echo planar sequences need only 30 to 50 msec to completely acquire one image and are thus able to image the entire ventricle within one heartbeat. However, they are also more susceptible to image artefacts. As gradients capable of producing high quality echo planar images are not widely available, ultrafast gradient echo techniques are commonly used for MR-perfusion imaging. A good correlation between quantitative estimates of myocardial perfusion by MRI after injection of an intravascular contrast agent and microsphere measurements has been shown in animal experiments but quantitative MR perfusion measurements have not yet been performed in humans. Clinical studies have until now focused on visual and parametric analysis of signal intensity time curves. From these studies, sensitivities and specifities in the range of 60 to 90% as compared to x-ray coronary angiography and scintigraphy were reported despite the fact that only parts of the left ventricular myocardium could be assessed. However, a generally accepted method of acquiring and analysing MR perfusion images does not yet exist. Therefore, future improvements of hardware and pulse-sequences as well as the development of new blood pool contrast agents are necessary before MR-perfusion imaging will become a widely accepted and clinically useful diagnostic procedure.

Artifacts

A fluorometric determination of urinary 17-hydroxycorticosteroids using benzamidine.

A fluorometric determination of urinary 17-hydroxycorticosteroids using a reaction of benzamidine with compounds carrying the dihydroxyacetone side chain is described. The fluorescent compounds have excitation and emission maxima at 370 and 480 nm, respectively. The method includes enzymatic hydrolysis with beta-glucuronidase (EC 3.2.1.31, from Escherichia coli) and extraction with methylene chloride and generation of fluorescence in alkaline solution (pH 13.4). The specificity of the reaction was examined and the results were compared with those of an accepted method based on the Porter-Silber reaction (C. C. Porter and R. H. Silber, 1950, J. Biol. Chem. 185, 201-207). The coefficient of correlation was 0.945 with regression line of y = 0.91x + 0.7 mg/day (y, present method; x, Porter-Silber reaction method). Sensitivity of the reaction was 0.5 microgram/ml of standard or sample, mean recovery of cortisol added to five urine samples (5-micrograms addition) was 95%, and the coefficient of variation of the method (five repeated assays of sample with a value of 5.2 mg/liter) was 6.2%.

17-Hydroxycorticosteroids

Further studies with the fluorescent treponemal antibody-absorption double-staining procedure.

A double-staining procedure for the fluorescent treponemal antibody-absorption test, using fluorescein isothiocyanate as a label for the class-specific anti-human globulin and tetramethylrhodamine isothiocyanate as a label for a counterstain reagent, has been described. This method requires the addition of a KP560 barrier filter, with a microscope equipped with vertical illumination, to exclude the rhodamine emission in reading the fluorescein fluorescence. The present study evaluated reversing the dye label for each conjugate in the double-staining procedure, thus eliminating the need for the KP560 filter. It also considered the possibility of shortening the counterstaining time and compared various methods for preparing antigen slides in an attempt to establish a method that increases the number of treponemes per microscopic field. The results indicate that a rhodamine-labeled class-specific anti-human globulin as a primary stain, and a fluorescein-labeled anti-treponemal globulin as a counterstain, provide an acceptable method for performing the fluorescent treponemal antibody-absorption double-staining procedure. Nonfixed antigen slides were held for 16 days in a desiccator or stored in plastic bags with silica gel for 3 weeks; then, with methanol fixation, they were used satisfactorily in the double-staining procedure. A shortened incubation time for the counterstain allowed more rapid slide processing.

Antigens, Bacterial

The management of arthrogryposis.

Arthrogryposis has an evil reputation among orthopedic surgeons, for the deformities are known to be resistant to correction and relapse during growth is common. It is suggested that many of these difficulties have been due to a delay in initiating treatment, to the use of unsuitable methods such as manipulation, and to a lack of appreciation of the pathologic changes. The author's experience with a large number of personally treated cases has convinced him that aggressive surgical treatment in infancy and early childhood is more successful than previously accepted methods of care (Figs. 22, 23).

Arm

New methodologies for pharmacological treatment trials for alcohol dependence.

As the number of pharmacological agents for the treatment of alcoholism continues to proliferate, there is an increasing need to design studies that accurately measure the efficacy of these agents. Key study design issues include selecting subjects, calculating patient retention, determining medication compliance, maintaining adequate sample size to ensure that a clinically meaningful therapeutic effect will not be missed, and measuring the study outcome, including the amount of alcohol consumed and levels of craving. Because there is evidence that self-report of alcohol consumption and medication compliance can be unreliable in subjects, biological methods have been used. One type of direct measurement, carbohydrate-deficient transferrin levels, has been found to be a reasonably sensitive indicator of alcohol consumption that may provide meaningful outcome information. The ingestion of riboflavin with medication and its urinary measurement is an accepted method of compliance detection. Improved study design will lead to continued advances in pharmacotherapy for the treatment of patients with alcoholism.

Alcohol Deterrents

Comparison of indirect immunofluorescence and Western blot for detection of anti-human immunodeficiency virus antibodies.

There was 100% agreement between the results of indirect immunofluorescence (IF) and Western blot testing when these methods were used to detect antibodies to the human immunodeficiency virus in sera from 25 patients with acquired immune deficiency syndrome (AIDS), 20 patients with AIDS-related complex, 186 subjects at high risk for AIDS, and 40 healthy heterosexuals. However, there was only an 88.7% correlation between IF and Western blot results for 728 sera from blood and plasma donor centers that were selected on the basis of screening enzyme immunoassay reactivity. IF tests yielded nine false-negatives and were equivocal, yielding a nonspecific pattern of reactivity for both infected and uninfected cells for 73 of these specimens. The IF and Western blot methods were equal in performance for the detection of anti-human immunodeficiency virus antibodies in the high-risk and unselected low-risk groups, proving to be a practical approach for testing specimens from these subjects. However, the Western blot was the most acceptable method for the validation of specimens from groups at low risk for AIDS that were selected based on enzyme immunoassay reactivity.

AIDS-Related Complex

Noninvasive measurement of rate of left ventricular relaxation by Doppler echocardiography. Validation with simultaneous cardiac catheterization.

BACKGROUND: The instantaneous pressure gradient between the left ventricle and left atrium during systole can be calculated from the mitral regurgitation Doppler velocity curve. The purpose of our study was to determine the accuracy of measuring the time constant of relaxation (TAU) derived from the Doppler mitral regurgitation signal by comparing it with simultaneous high-fidelity left ventricular pressure measurements in humans. METHODS AND RESULTS: Twenty-five patients had continuous-wave Doppler mitral regurgitation recordings performed with simultaneous high-fidelity left ventricular pressure measurements. Fifteen of these patients had measurements of six to eight beats at various RR intervals. Doppler velocity curves were converted to left ventricular pressure curves by different methods through application of the modified Bernoulli equation at 3-msec intervals. The correlation between catheter-derived and Doppler-derived TAU was best when a zero asymptote and knowledge of the left ventricular end-diastolic pressure were used. A less optimal but acceptable method used the addition of 20 mm Hg to the Doppler-derived ventriculoatrial gradient. Use of a nonzero asymptote for calculation of TAU yielded poor correlation between catheter and Doppler measurements. The correlation of percentage change in Doppler-derived TAU plotted against percentage change in catheter-derived TAU was poor. CONCLUSIONS: The descending limb of the Doppler-derived mitral regurgitation velocity signal can be used as a semiquantitative estimate of the rate of ventricular relaxation. This method requires knowledge of left atrial pressure and may not be sufficiently accurate for detecting small changes in the rate of relaxation on a beat-to-beat basis.

Atrial Function, Left

Quadruplet pregnancy in IVF.

The frequency of multiple pregnancy following IVF with the presently accepted methods is ten times higher than in natural cycles, and is identical to that following induction of ovulation with HMG. In spite of the fact that multifetal pregnancy exposes both fetus and mother to certain dangers, most couples joining IVF programs expose themselves to, and generally accept the risk of, multiple pregnancy, since this is their last resort for having a baby of their own. We report such a case of quadruplet pregnancy after the IVF procedure and review the literature.

Abortion, Induced

[Oropharyngeal flora. Epidemiologic survey of prevalence].

OBJECTIVES: Epidemiological surveys which are not frequently carried out in medical practice should provide useful information for the choice of antibiotics to be prescribed in community-acquired infections particularly with the recent development of therapeutic difficulties due to resistant strains. We therefore analyzed the prevalent pharyngeal flora in a general patient population. METHODS: The study was conducted during a single 24-hour period in 1991 by 43 general practitioners and included 645 subjects consulting for benign affections. No patient selection was made. Two pharyngeal swabs were obtained from each subject and cultured in aerobic and anaerobic conditions. Internationally accepted methods for identifying bacteria in pharyngeal samples all performed by one well-equipped laboratory. Beta-lactamase activity was determined with the nitrocephine technique, both directly and after culture. RESULTS: Patient age varied from 16 to 45 years; most (68.5%) consulted for reasons other than ear-nose-throat affections. Only 41 patients (4.3%) consulted for sore throat and 65.4% had not received antibiotics for at least 6 months. Haemophilus influenzae was found in 59.6% of the patients, 20% of the strains were beta-lactamase producers as were 83.7% of the Moraxella catarrhalis strains identified. CONCLUSION: These factors are indicators of potential risk of therapeutic failure when using beta-lactams unstable to beta-lactamases for the treatment of pharyngeal infections.

Adolescent

Ocular manifestations of Sotos syndrome.

BACKGROUND: Sotos syndrome (cerebral gigantism) is a congenital syndrome characterized by large body size for patient age, advanced bone age, and unusual facial characteristics with varying levels of cognitive, developmental and perceptual deficits. While more than 150 cases have been reported, only a single case report has been published in the ophthalmic literature. This study briefly reviews the pertinent aspects of this syndrome and reports on the medical, physical, developmental and ocular manifestations of 32 subjects. METHODS: Our patient population was obtained from several schools and colleges of optometry and private offices and clinics of optometrists and ophthalmologists. The Sotos Syndrome Support Association assisted in obtaining patients for this study as well. All children had been previously diagnosed as having SS. Commonly accepted methods for evaluating young, non-verbal, and/or handicapped children were used. RESULTS: Our findings indicate that moderate to high refractive error (hyperopia), nystagmus, and strabismus (esotropia) are commonly associated conditions of this syndrome. CONCLUSIONS: Since many of our subjects exhibited these amblyogenic precursors, a routine optometric vision evaluation should be an essential part of the individual educational and habilitation plan for all children with Sotos syndrome.

Abnormalities, Multiple

[A case report of Konno's operation for discrete type subaortic stenosis associated with previous VSD closure and repair of coarctation].

A patient, 1 year and 3 month old boy, underwent Konno's operation for severe discrete type subaortic stenosis, which had developed after the coarctation repair (Subclavian Flap Method) at 15 day old and VSD closure at 21 day old. Konno's operation was performed successfully with SJM 21A and postoperative course was uneventful. The discrete type subaortic stenosis may also develop after VSD closure complicating with coarctation complex. Konno's operation is an acceptable method and stenotic left ventricular outflow tract can be enlarged sufficiently in even young infants. This is the youngest patient treated successfully with Konno's operation in Japan.

Aorta, Thoracic

Contrast sensitivity determined with the spatial bandwidth equalization technique: threshold, suprathreshold, and spatiotemporal measurements.

Contrast sensitivity functions were obtained from normal subjects using a spatial bandwidth equalization (SBE) technique and the more conventional display method. Static sensitivity measurements obtained with the two methods were in good agreement. However, when the patterns were counterphase flickered , sensitivity to the lower spatial frequencies was enhanced using the conventional method while sensitivity measured with the SBE technique was slightly depressed. The SBE method also was used to investigate suprathreshold contrast perception with static and flickering gratings. In general, the perception of contrast was independent of spatial frequency content of the stimulus, especially with increasing contrast levels and flicker frequencies. These studies have shown that the SBE technique is an acceptable method to assess static contrast sensitivity and suprathreshold contrast perception.

Humans