PubMed HealthSearch

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

beta Recombinase catalyzes inversion and resolution between two inversely oriented six sites on a supercoiled DNA substrate and only inversion on relaxed or linear substrates.

The beta recombinase, in the presence of a chromatin-associated protein such as Hbsu, catalyzes DNA resolution or DNA inversion on supercoiled substrates containing two directly or inversely oriented six sites. Hbsu stabilizes the formation of the recombination complex (Alonso, J. C., Weise, F., and Rojo, F. (1995) J. Biol. Chem. 270, 2938-2945). In this study we show that resolution by beta recombinase strictly requires supercoiled DNA, but inversion does not. On a substrate with two inversely oriented six sites, beta recombinase catalyzed both resolution and inversion if the DNA was supercoiled but only inversion if the substrate was relaxed or linear. Hbsu was critical for the formation of synaptic complexes; its concentration relative to that of the supercoiled DNA substrate determined whether resolution or inversion products were preferentially formed. The results suggest that the beta recombinase forms unproductive short-lived synaptic complexes between two juxtaposed inversely oriented six sites; the presence of 3 to 13 Hbsu dimers per supercoiled DNA molecule would stabilize a synaptic complex with a relative geometry of the six sites allowing beta recombinase preferentially to achieve resolution. Supercoiling probably helps to overcome an energetic barrier, since resolution does not occur in relaxed DNA. The presence of >30 Hbsu dimers per DNA molecule probably favors the formation of a recombination complex with a different geometry since the reaction is directed preferentially toward DNA inversion.

Catalysis

Influence of zoom factor on centre-of-rotation of the SPECT system and on the resolution of tomographic images.

The influence of zooming on centre-of-rotation (COR) of the rotating camera-based SPECT system and on the resolution of tomographic images was investigated. COR values were measured as a function of zoom factor varying from x1.0 to x3.0. Measurements were performed using two SPECT systems collimated with three collimators. In this study, the COR was observed to shift linearly with zoom factor. The influence of zooming on COR depends on the location and the deviation of the COR from the axis-of-rotation (AOR). We recommend that the deviation of the COR from the AOR be kept to within 0.4 pixels corresponding to 2.4 mm. Unlike zooming, the magnitude of COR shift is uncorrelated to the type of collimator used. Contrast and spatial resolution variations of the tomographic images were quantitated as a function of COR shift for clinical data acquired using no zoom factor and a zoom factor of 2.50. The resolution indices were observed to be more sensitive to COR shift for clinical data acquired using no zoom factor. The sensitivity appeared to be inversely dependent on the zoom factor utilized. However, zooming was found not to preserve the same resolution degradation. Optimum resolution images can be reconstructed by requiring the COR be determined and clinical study be acquired using the same zoom factor and collimator. For qualitative evaluation of tomographic images, the zoom factor requirement can be removed provided that the deviation of the COR from the AOR is within the recommended limit. This limit allows for a maximum spatial resolution degradation of 5%.(ABSTRACT TRUNCATED AT 250 WORDS)

Image Enhancement

Modeling human eye aberrations and their compensation for high-resolution retinal imaging.

We introduced a mathematical eye model using Gullstrand's six-surface eye model modified by clinically measured aspherical data to study human eye aberrations and their compensation for high-resolution retinal imaging. Ray tracing was used to characterize aberrations and point spread functions (PSFs) of the eye model. By using the Zernike polynomial decomposition of the calculated pupil function, we quantified the wavefront aberrations. Based on calculated PSFs, we designed optical inverse filters to reduce the aberrations for a large pupil size and improve the resolution. Spherical aberration and oblique astigmatism were found to be in good agreement with published experimental measurements. Spherical aberration and defocus were the most significant aberrations for on-axis imaging, whereas oblique astigmatism and coma combined with spherical aberration and defocus were most significant for off-axis imaging. The best retinal image resolution occurred at 2- to 3-mm pupil diameter. After aberration correction for an 8-mm diameter pupil, the resolutions for on-axis or 9 degrees off-axis imaging points were very close to diffraction-limited resolutions. Over a limited field of view (FOV), retinal image resolution of the eye model can be greatly improved by aberration correction using aspheric and astigmatic lenses. For imaging large FOVs, space-variant compensation techniques will be required for aberration correction.

Astigmatism

High-resolution scanning electron microscopy of frozen-hydrated cells.

Cryo-fixed yeast Paramecia and sea urchin embryos were investigated with an in-lens type field-emission SEM using a cold stage. The goal was to further develop and investigate the processing of frozen samples for the low-temperature scanning electron microscope (LTSEM). Uncoated frozen-hydrated samples were imaged with the low-voltage backscattered electron signal (BSE). Resolution and contrast were sufficient to visualize cross-fractured membranes, nuclear pores and small vesicles in the cytoplasm. It is assumed that the resolution of this approach is limited by the extraction depth of the BSE which depends upon the accelerating voltage of the primary beam (V0). In this study, the lowest possible V0 was 2.6 kV because below this value the sensitivity of the BSE detector is insufficient. It is concluded that the resolution of the uncoated specimen could be improved if equipment were available for high-resolution BSE imaging at 0.5-2 kV. Higher resolution was obtained with platinum cryo-coated samples, on which intramembranous particles were easily imaged. These images even show the ring-like appearance of the hexagonally arranged intramembranous particles known from high-resolution replica studies. On fully hydrated samples at high magnification, the observation time for a particular area is limited by mass loss caused by electron irradiation. Other potential sources of artefacts are the deposition of water vapour contamination and shrinkage caused by the sublimation of ice. Imaging of partially dehydrated (partially freeze-dried) samples, e.g. high-pressure frozen Paramecium and sea urchin embryos, will probably become the main application in cell biology. In spite of possible shrinkage problems, this approach has a number of advantages compared with any other electron microscopy preparation method: no chemical fixation is necessary, eliminating this source of artefacts; due to partial removal of the water additional structures in the cytoplasm can be investigated; and finally, the mass loss due to electron beam irradiation is greatly reduced compared to fully frozen-hydrated specimens.

Animals

Properties of high-pass resolution perimetry targets.

Relationships between high-pass resolution perimetry ring targets and conventional perimetry and acuity targets were explored by optical analytical techniques and by comparative measurements in normal humans. High-pass resolution and acuity targets produced closely proportional resolution measurements, showing that the critical ring detail is the width of the bright core. High-pass resolution and conventional perimetry thresholds were not equally well correlated. From a purely optical point of view, high-pass resolution targets appeared to lose somewhat more contrast on defocusing. On the other hand, high-pass resolution appears to show less variability in practical, clinical use.

Adult

High resolution scanning electron microscopy of the cell.

The scanning electron microscope (SEM) has become a powerful tool for ultrastructural research with improvement of the instrument's resolution and progress in specimen preparation techniques. With regard to resolution, it has been improved step-by-step in this decade and, in 1985, an ultra-high resolution SEM (UHS-T1) was developed, with a resolution of 0.5 nm. Concerning specimen preparation, the osmium-DMSO-osmium method, which is effective for revealing intracellular structures, has come to be widely used. Techniques for observing smaller objects, such as bacteriophages, viruses, and biological macromolecules, have also been devised in recent years. As a result of these preparation techniques and the availability of the ultra-high resolution SEM, the application of SEM in biology is expanding rapidly. In this paper, an outline of the ultra-high resolution SEM, techniques for specimen preparation, findings of some biological materials by these techniques, and guidelines to making the specimens, are described.

Animals

Visual resolution when light enters the eye through different parts of the pupil.

1. Threshold contrasts for resolution of sinusoidal gratings imaged on to the retina through a decentred 2 mm pupil were measured.2. No loss in resolution was found when the pupil was decentred parallel to the lines of the gratings. A loss in resolution by a factor of 3 occurred when the pupil was decentred by 3 mm perpendicular to the lines of the gratings.3. The effects of focus on the threshold contrast for a grating viewed through a centred and decentred pupil were used to show that at least a portion of the loss in resolution is due to optical aberrations.4. Using a neon-helium gas laser as a coherent light source, interference fringes were produced on the retina directly. Threshold contrasts for resolution of the fringes were determined for different positions of entry of the beams of light through the pupil. When the Stiles-Crawford brightness effect was compensated for, no loss in resolution was found to occur for decentred entry of the beams.5. It is concluded that the off-axis loss of visual acuity is wholly due to optical aberrations in the eye.6. The ratios between the threshold contrasts for sinusoidal gratings and for interference fringes are used to calculate the optical transfer functions of the off-axis aberrations of the eye.

Humans

Human peripheral spatial resolution for achromatic and chromatic stimuli: limits imposed by optical and retinal factors.

1. The aim of this study was to determine whether optical, receptoral or higher-order neural properties limit spatial resolution (acuity) in human vision, especially in the peripheral regions of the visual field. 2. Both achromatic and chromatic stimuli were used, and measures were taken to ensure that the resolution estimates were not contaminated by the detection of spatial sampling artifacts. Spatial contrast sensitivity functions were measured at retinal locations from 0 to 55 deg along the naso-temporal meridian for: (i) discriminating the direction of drift of luminance-modulated (black-white) sinusoidal stimuli drifting at 8 Hz (achromatic task); and (ii) for detecting isoluminant red-green sinusoidal stimuli drifting at 0.4 Hz (chromatic task). Achromatic contrast sensitivity functions were also measured along the vertical meridian for eccentricities of 8 and 40 deg. Each achromatic function was extrapolated to a contrast sensitivity of one (100% contrast) to estimate achromatic acuity. Chromatic acuities were obtained by expressing chromatic contrast in terms of cone contrasts and using the same method of extrapolation. We compared the results with recent data on human optical properties and retinal anatomy. 3. Both achromatic and chromatic acuity decline with distance from the fovea, but at a faster rate than that dictated by the known optical and/or receptoral properties of the human eye. We conclude that, for stimuli of either achromatic or chromatic contrast, peripheral spatial resolution is limited by post-receptoral mechanisms. Also, chromatic acuity declines more steeply than luminance acuity with eccentricity suggesting that there are additional post-receptoral limitations on colour resolution in the periphery. 4. A clear naso-temporal asymmetry is seen in the resolution whose dependence is qualitatively, but not quantitatively, similar to the Nyquist limits imposed by the asymmetric density of human retinal ganglion cells. We discuss the possibility that in peripheral vision (beyond the optic nerve head) the spacing of ganglion cells may pose a fundamental limit on the resolution of achromatic stimuli, but not chromatic stimuli.

Color Perception

Localized in vivo high-resolution NMR imaging using gradient subencoding technique.

A new spatial localization technique for in vivo high-resolution imaging is presented here. In contrast to other localization techniques that use a series of rf pulses to define a volume of interest, only one rf pulse is utilized in the proposed method for selection of a region to be imaged. Instead of rf pulses for region selection, subencoding gradient pulses are used for the localization together with a convolution process on each phase-encoding gradient by a set of additional gradients (e.g., y direction). Then the 2-D localization is completed by restricting the bandwidth in the readout direction (e.g., x direction). The latter is simply achieved by using a low-pass filter in the receiver system. By applying this technique on a human body, localized in vivo high-resolution images are obtained for the knee with much improved resolution. 100 x 100 microns in-plane (x,y plane) resolution images obtained from the human knee demonstrate that localized in vivo high-resolution imaging for both human and animals is possible with an in-plane resolution of below 100 microns.

Image Processing, Computer-Assisted

Resolution properties of a 2048 x 2048 matrix image intensifier-TV based digital radiography system.

Spatial resolution properties of a 2048 x 2048 matrix image intensifier (II) TV based real-time digital radiography (DR) system were investigated. The presampling modulation transfer function (MTF), which includes the unsharpness of the detector and the blurring effect of the sampling aperture, was measured by a slit method. Also determined was the limiting resolution using a bar pattern. It was found that, the spatial resolution in this system is substantially improved relative to previous II-TV based DR systems, and is comparable or even superior to that in a computed radiography system depending on the imaging plate employed. However, the presampling MTF for 2048 x 2048 matrix is comparable to that for 1024 x 1024 matrix in this DR system, because the same sampling aperture is assumed to be used for both matrices. Even under these conditions obtained the improved clinical image since the Nyquist frequency is doubled for 2048 x 2048 matrix. It should be noted that the resolution property in the II-TV based DR system depends on the signal current from the TV image pickup tube (level of image pixel value) and also on the size of the iris in the TV lens. We must pay attention to these parameters when acquiring clinical images and evaluating the resolution properties. Finally, it was demonstrated that smaller focus than that used in a screen-film system can be employed in the DR system due to its high sensitivity, so the geometric unsharpness can be reduced. Therefore, the image resolution of our system was found to be superior to a screen-film system at some geometric magnification factors.

Humans

Evaluation of spatial resolution as a function of thickness for time-resolved optical imaging of highly scattering media.

Previous experimental and theoretical investigations of the utility of time-resolved methods as a means of optical imaging through the human breast have indicated that a spatial resolution of approximately 1 cm is achievable by isolating the shortest path length photons which propagate through the tissue. Studies have also shown that resolution may be improved further by extrapolating the measured distribution using an appropriate model of photon transport. The experiments described here were performed in order to observe the relationship between achievable spatial resolution and the thickness of the medium. For a given time gate, an improvement in the spatial resolution was observed as the object thickness was reduced. Overall, the results indicate that a breast compression of about 1 cm may improve the limiting spatial resolution by as much as 7 mm. Less encouraging is the implication that temporal extrapolation over several orders of magnitude in intensity is required to achieve a comparable improvement in spatial resolution.

Biophysical Phenomena

In vitro resolution of poxvirus replicative intermediates into linear minichromosomes with hairpin termini by a virally induced Holliday junction endonuclease.

Available evidence suggests that one or more late viral gene products are involved in processing poxvirus replicative intermediates into mature progeny hairpin-terminated genomes. Cloned versions of the Shope fibroma virus (SFV) replicated telomere in the inverted repeat configuration were used as substrates to assay lysates from poxvirus-infected cells for protein fractions that participate in the resolution of the circular substrate plasmid into a linear minichromosome with viral hairpin termini. An activity in a crude protein fraction obtained from vaccinia virus-infected cells at late times during the replicative cycle was capable of accurately resolving all poxviral inverted repeat replicative intermediates tested. The resolved linear products are identical to the products of in vivo resolution and possessed symmetrical nicks which mapped at the borders of the inverted repeat sequence. Strand-specific nicks were also identified, which mapped within the telomere resolution target sequence known to be required for telomere resolution in vivo. The resolving activity that we have identified is specific to virus-infected cells at late times during replication and cleaves cloned poxviral telomeric substrates in a fashion expected of a classic Holliday junction-resolving enzyme in addition to possessing a telomere resolution target-specific nicking activity. Although a Holliday junction-resolving activity would also be expected to play a role in the recombination induced by poxvirus infection, the appearance of the activity described here only after the commencement of viral late protein synthesis suggests that it functions strictly at late times. Other non-viral Holliday junction analogs can also be cleaved by this extract, suggesting that this component of the resolution activity may also play a role in other viral processes that require cleavage of a branched DNA structure. Thus, we have identified a poxviral activity that may be a part of a protein complex which resolves concatemeric replicative intermediates of viral DNA as well as participate in general recombination late during infection.

Animals

High spatial resolution automated perimetry in glaucoma.

BACKGROUND: Automated perimetry is of fundamental importance in assessing visual function in glaucoma. A technique was evaluated to perform high spatial resolution automated perimetry to allow a more detailed assessment of the luminance sensitivity in selected regions of the visual field than is possible with conventional perimetry. METHOD: High spatial resolution perimetry was performed using a Humphrey automated perimeter by measuring luminance sensitivity across a 9 by 9 degree custom grid of 100 test locations with a separation between adjacent locations of 1 degree. Quantitative analysis of the raw and Gaussian filtered thresholds was performed to assess the repeatability of the technique in normals, glaucoma suspects, and glaucoma patients. RESULTS: The testing protocol was well tolerated by all subjects. High spatial resolution perimetry in glaucomatous eyes demonstrated fine luminance sensitivity loss not suspected with conventional perimetry. High spatial resolution perimetry also demonstrated reproducible areas of sensitivity loss in some glaucomatous eyes in areas of the visual field which appear normal with conventional programmes. The repeatability of the technique correlated with mean threshold sensitivity and was substantially improved to clinically acceptable levels by Gaussian filtering the thresholds. CONCLUSION: This technique of high spatial resolution perimetry allows the practical assessment of selected regions of the visual field at higher resolution than conventional perimetry, and may be clinically useful in glaucoma.

Case-Control Studies

Spontaneous resolution of severe chronic glue ear in children and the effect of adenoidectomy, tonsillectomy, and insertion of ventilation tubes (grommets).

OBJECTIVE: To measure the time to spontaneous resolution of severe chronic otitis media with effusion (glue ear) in children and study the effects of adenoidectomy, adenotonsillectomy, and ventilation tubes (grommets). DESIGN: Randomised controlled study over 12 years. SETTING: Paediatric otorhinolaryngology clinics and in-patient unit. SUBJECTS: 228 children aged 2-9 years with pronounced hearing loss from glue ear and persistent bilateral middle ear effusions confirmed on three occasions over three months. INTERVENTIONS: Children were randomly allocated to adenotonsillectomy, adenoidectomy, or neither procedure. In all groups a Shepard type ventilation tube was inserted in one randomly chosen ear. Follow up was annually for five years and then less often for up to seven years four months. For analysis the two operated groups were combined. MAIN OUTCOME MEASURES: Otoscopic clearance of fluid, change in tympanogram, and improvement in mean audiometric hearing threshold. RESULTS: Survival analysis showed appreciable otoscopic and tympanometric resolution of fluid with ventilation tubes alone and adenoidectomy alone compared with no surgery. Further improvement was seen after combination of both treatments. Mean audiometric hearing thresholds improved with fluid resolution. Resolution was delayed in younger children and in those whose parents smoked, irrespective of treatment. Whereas a single insertion of a Shepard tube resolved the glue for a mean (SD) period of 9.5 (5.2) months, the effect of adenoidectomy was sustained throughout follow up. CONCLUSIONS: Treatment of glue ear considerably shortened the time to fluid resolution, combined adenoidectomy and tube insertion being better than either procedure alone. Resolution was longer in younger children and those whose parent(s) smoked, irrespective of treatment.

Adenoidectomy

Normal and diseased isolated lungs: high-resolution CT.

High-resolution computed tomography (CT) scans of 12 isolated, inflated, fresh lungs obtained at autopsy were compared with thin, paper-mounted lung sections obtained at the same levels. In six lungs considered intrinsically normal, high-resolution CT showed normal interlobular septa and pulmonary arteries in the lobular core, but lobular bronchioles were not visible. Edematous fluid resulted in thickening and increased visibility of interlobular septa. In three emphysematous lungs, high-resolution CT accurately demonstrated the degree of emphysema and suggested its centrilobular nature. In two lungs with honeycombing, cysts lined by fibrosis were easily seen on high-resolution CT scans. In less severely involved areas, septal thickening and intralobular fibrosis were seen on high-resolution CT scans, but small (1 mm) cysts were invisible. High-resolution CT was able to demonstrate some features of the normal secondary pulmonary lobule and structural alterations produced by various diseases.

Humans

Effects of strabismus on responsivity, spatial resolution, and contrast sensitivity of cat lateral geniculate neurons.

Rearing cats with esotropia is known to cause a number of deficits in visual behavior tested through the deviated eye. These include a loss of orienting response to stimuli presented in the nasal visual field of the deviated eye, a reduction in visual acuity, and a general reduction in contrast sensitivity at all spatial frequencies. To assess the involvement of the lateral geniculate nucleus (LGN) in these deficits, we measured the following: 1) the visual responsiveness of lamina A1 cells with peripheral (more than 10 degrees from area centralis) receptive fields in three esotropic and three normal cats and 2) the spatial resolution and contrast sensitivity of lamina A X-cells with central (within 5 degrees of the area centralis) receptive fields in six esotropic and six normal cats. For comparison, we also measured LGN X-cell spatial resolutions in four exotropic cats and in two cats raised with an esotropia in one eye and the lids of the other eye sutured shut (MD-estropes). Recordings from the lateral portion of lamina A1 in esotropic cats yielded similar numbers of visually responsive cells with far nasal receptive fields as were seen in normal animals. Peak and mean response rates to a flashing spot also were normal. In addition, no differences were found between esotropes and normals in the percentages of X- and Y-cells encountered. These results suggest that the loss of orienting response to stimuli presented in the nasal field (12, 20) is not due to a loss of neural responses in the LGN of esotropic cats. In addition, they suggest that decreases in cell size in lamina A1 of esotropic cats (13, 36; R. E. Kalil, unpublished observations) are not accompanied by marked functional abnormalities of the cells and that cortical abnormalities ipsilateral to the deviated eye (22) are likely to have their origin within striate cortex itself. Recordings from lamina A cells with receptive fields near area centralis revealed that the average X-cell spatial resolution in esotropes (2.1 cycles/deg) was significantly lower than that in normal cats (3.1 cycles/deg). This reduction was seen in all esotropic cats tested and was due both to an increase in the proportion of X-cells with very low spatial resolution and to a loss of X-cells responding to high spatial frequencies (greater than 3.25 cycles/deg). The average spatial resolution of X-cells driven by the deviated eye in MD-esotropes fell midway between those of esotropes and normals. In exotropes, mean X-cell spatial resolution was normal.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals

High-resolution intravascular magnetic resonance imaging: monitoring of plaque formation in heritable hyperlipidemic rabbits.

BACKGROUND: The individual makeup of atherosclerotic plaque has been identified as a dominant prognostic factor. With the use of an intravascular magnetic resonance (MR) catheter coil, we evaluated the effectiveness of high-resolution MR in the study of the development of atherosclerotic lesions in heritable hyperlipidemic rabbits. METHODS AND RESULTS: Sixteen hyperlipidemic rabbits were investigated at the ages of 6, 12, 24, and 36 months. The aorta was studied with digital subtraction angiography and high-resolution MR with the use of a surface coil and an intravascular coil that consisted of a single-loop copper wire integrated in a 5F balloon catheter. Images were correlated with histological sections regarding wall thickness, plaque area, and plaque components. Digital subtraction angiography revealed no abnormalities in the 6- and 12-month-old rabbits and only mild stenoses in the 24- and 36-month-old rabbits. High-resolution imaging with surface coils resulted in an in-plane resolution of 234x468 microm. Delineation of the vessel wall was not possible in younger rabbits and correlated only poorly with microscopic measurements in the 36-month-old rabbits. Intravascular images achieved an in-plane resolution of 117x156 microm. Increasing thickness of the aortic wall and plaque area was observed with increasing age. In the 24- and 36-month-old animals, calcification could be differentiated from fibrous and fatty tissue on the basis of the T2-fast spin echo images, as confirmed by histological correlation. CONCLUSIONS: Atherosclerotic evolution of hyperlipidemic rabbits can be monitored with high-resolution intravascular MR imaging. Image quality is sufficient to determine wall thickness and plaque area and to differentiate plaque components.

Animals

Deterioration of oxygenation and abnormal lung microvascular permeability during resolution of leukopenia in patients with diffuse lung injury.

To determine whether circulating leukocytes contribute to gas exchange abnormalities in diffuse lung injury, we retrospectively examined oxygenation in 6 patients who met 3 criteria: leukopenia caused by marrow aplasia from remission-inducing chemotherapy for myelogenous leukemia, the eventual resolution of leukopenia, and concurrent acute respiratory failure diagnosed clinically as increased permeability pulmonary edema. Four of the 6 patients abruptly developed overt clinical evidence of pulmonary dysfunction within the 96 h preceding the resolution of the peripheral leukopenia. In all 6 patients, the alveolar to arterial oxygen tension difference increased between leukocyte counts. The mean value for the alveolar to arterial oxygen tension difference for the group doubled during this period (148 +/- 37 mmHg 3 days prior to resolution; 290 +/- 37 mmHg 1 day after resolution; p less than 0.05). As an index of lung capillary permeability, we measured the lung permeability-surface area product for urea (PSu) for an additional patient with oxygen toxicity and drug-induced leukopenia whose hypoxemia increased immediately before the resolution of leukopenia. The PSu in this patient was high, in the range previously reported as being highly specific for increased permeability pulmonary edema with a fatal outcome. We conclude that such diffuse lung injury resembling the adult respiratory distress syndrome can occur in leukopenic patients, but the resolution of leukopenia in such patients may be associated with worsening oxygenation and with abnormally high pulmonary microvascular permeability. These observations do not prove a causal relationship but provide a clinical parallel to several leukocyte-depletion studies reported in animal models of increased permeability pulmonary edema that implicate white blood cells in the pathogenesis of hypoxemia and lung edema.

Adult