Screen-printed bienzymatic sensor based on sol-gel immobilized Nippostrongylusbrasiliensis acetylcholinesterase and a cytochrome P450 BM-3 (CYP102-A1) mutant.

Here, we describe the development of a bi-enzymatic biosensor that simplifies the sample pretreatment steps for insecticide detection, and opens the way for a highly sensitive detection of phosphorothionates in food. These compounds evolve their inhibitory activity towards acetylcholinesterases (AChEs) only after oxidation, which is performed in vivo by P450 monooxygenases. Consequently, phosphorothionates require a suitable sample pretreatment by selective oxidation to be detectable in AChE based systems. In this study, enzymatic phosphorothionate activation and AChE inhibition were integrated in a single biosensor unit. A triple mutant of cytochrome P450 BM-3 (CYP 102-A1) and Nippostrongylus brasiliensis AChE (NbAChE) was immobilized using a fluoride catalyzed sol-gel process. Different sol-gel types were fabricated and characterized regarding enzyme loading capacity and enzyme activity containment. The enzyme sol-gel itself already proved to be suitable for the highly sensitive detection of paraoxon and parathion in a spectrometric assay. A method for screen-printing of this enzyme sol-gel on thick film electrodes was developed. Finally, amperometric biosensors containing coimmobilized NbAChE and the cytochrome P450 BM-3 mutant were produced and characterized with respect to signal stability, organophosphate detection, and storage stability. The detection limits achieved were 1 microg/L for paraoxon and 10 microg/L for parathion, which is according to EC regulations the highest tolerable pesticide concentration in infant food.

Acetylcholinesterase↗

Analysis of sulthiame in serum by narrow-bore high-performance liquid chromatography. Comparison of direct sample injection with pre-column switching and extrelut extraction.

Two high-performance liquid chromatographic methods for the analysis of sulthiame in serum are described. In the first method direct injection of serum samples onto a 4 x 4 mm I.D. (C18, 25 microns) precolumn in a column-switching device was used. After a purge step, the adsorbed analytes were eluted onto a 250 x 3 mm I.D. (C18, 5 microns) narrow-bore column for chromatographic separation. In the second method the sample pretreatment was an Extrelut extraction with dichloromethane-propanol-2 (95:5). After evaporation of the solvents, the residue was dissolved in methanol. The chromatographic separation was carried out on the same analytical column as used in the column-switching method. Both sample pretreatment methods were compared with respect to their suitability of routine analysis of sera from patients also receiving other antiepileptic drugs.

Chromatography, High Pressure Liquid↗

Isotachophoresis and isotachophoresis--zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection.

The use of a poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors, to electrophoretic separations of a group of inorganic anions (chloride, nitrate, sulfate, nitrite, fluoride and phosphate) that need to be monitored in various environmental matrices was studied. The electrophoretic methods employed in this study included isotachophoresis (ITP) and capillary zone electrophoresis (CZE) with on-line coupled ITP sample pretreatment (ITP-CZE). Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the CC chip were suppressed and electrophoresis was a dominant transport process in the separations performed by these methods. ITP separations on the chip provided rapid resolutions of sub-nmol amounts of the complete group of the studied anions and made possible rapid separations and reproducible quantitations of macroconstituents currently present in water samples (chloride, nitrate and sulfate). However, concentration limits of detection attainable under the employed ITP separating conditions (2-3 x 10(-5) mol/l) were not sufficient for the detection of typical anionic microconstituents in water samples (nitrite, fluoride and phosphate). On the other hand, these anions could be detected at 5-7 x 10(-7) mol/l concentrations by the conductivity detector in the CZE stage of the ITP-CZE combination on the CC chip. A sample clean-up performed in the ITP stage of the combination effectively complemented such a detection sensitivity and nitrite, fluoride and phosphate could be reproducibly quantified also in samples containing the macroconstituents at 10(4) higher concentrations. ITP-CZE analyses of tap, mineral and river water samples showed that the CC chip offers means for rapid and reproducible procedures to the determination of these anions in water (4-6 min analysis times under our working conditions). Here, the ITP sample pretreatment concentrated the analytes and removed nanomol amounts of the macroconstituents from the separation compartment of the chip within 3-4 min. Both the ITP and ITP-CZE procedures required no or only minimum manipulations with water samples before their analyses on the chip. For example, tap water samples were analyzed directly while a short degassing of mineral water (to prevent bubble formation during the separation) and filtration of river water samples (to remove particulates and colloids) were the only operations needed in this respect.

Electrochemistry↗

No effect of growth hormone on serum insulin-like growth factor binding protein-3 proteolysis.

Increased proteolysis of insulin-like growth factor binding protein (IGFBP)-3 is seen in several pathophysiological conditions and may represent an important mechanism for the regulation of insulin-like growth factor bioavailability. It has previously been suggested that proteolysis of IGFBP-3 is dependent on the GH status. To investigate this, IGFBP-3 proteolysis was measured in three groups of subjects: 1) GH-deficient patients before and after GH replacement (n = 14); 2) healthy subjects before and after 14 days of GH administration (n = 7); and 3) acromegalic patients before and after treatment with a long-acting SRIH analogue (octreotide; n = 14). In vivo IGFBP-3 proteolysis was investigated by Western immunoblotting. No difference was detected in pretreatment samples, and GH treatment in GH-deficient subjects or octreotide treatment in acromegalic subjects had no impact on in vivo proteolysis. In contrast, GH administration to healthy subjects caused a 21% increase in in vivo proteolysis (P = 0.0008). In vitro IGFBP-3 proteolysis was investigated by incubation of serum with 125I-rhIGFBP-3, followed by SDS-PAGE. In pretreatment samples, the percentage of proteolyzed 125I-rhIGFBP-3 was 13 +/- 1% (acromegalic subjects), 11 +/- 1% (healthy subjects), and 9 +/- 1% (GH-deficient subjects) (P < 0.009, GH-deficient vs. acromegalic subjects). Treatment had no effect on in vitro proteolysis. We conclude that GH status has no major impact on IGFBP-3 protease activity in serum.

Acromegaly↗

Method for the analysis of the methylphosphonic acid metabolites of sarin and its ethanol-substituted analogue in urine as applied to the victims of the Tokyo sarin disaster.

An analysis method for the methylphosphonic acid metabolites of sarin in urine using trimethylsilyl derivatization and flame photometric detection is described in this report. Authentic reference standards of isopropyl methylphosphonic acid (IMPA) and ethyl methylphosphonic acid (EMPA) as well as methylphosphonic acid were employed to estimate the concentration in human urine. A sample pretreatment procedure was developed for urine using a column of cation-loaded ion-exchange resins (Ag+ -, Ba2+ - or H+ -Dowex) and adjusting the pH of the eluate from the column to 3.75-3.85 improved recovery of the target compounds. The eluate was evaporated to dryness under vacuum prior to trimethylsilylation, to remove water and any hydroxy- or amino-carrying volatile substances. The sarin metabolites, because of their low volatility, were concentrated and could be derivatized for analysis. The use of synthesized authentic sarin and ethylsarin metabolites, i.e., IMPA and EMPA, made it possible to establish the necessary sample pretreatment procedures for derivatization and gas chromatography-flame photometric detection (GC-FPD) analysis. The detection limits were 0.025 ppm both for EMPA and [MPA, and 0.625 microM for MPA, respectively. This method can be useful for estimating the exposure level to sarin by assaying the metabolites in urine and it is applicable to a large numbers of samples.

Chemical Warfare Agents↗

High-performance liquid chromatographic procedures for the quantitative determination of paclitaxel (Taxol) in human urine.

A reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for the quantitative determination of paclitaxel in human urine. A comparison is made between solid-phase extraction (SPE) and liquid-liquid extraction (LLE) as sample pretreatment. The HPLC system consists of an APEX octyl analytical column and acetonitrile-methanol-0.2 microM ammonium acetate buffer pH 5 (4:1:5, v/v) as the mobile phase. Detection is performed by UV absorbance measurement at 227 nm. The SPE procedure involves extraction on Cyano Bond Elut columns. n-Butylchloride is the organic extraction fluid used for the LLE. The recoveries of paclitaxel in human urine are 79 and 75% for SPE and LLE, respectively. The accuracy for the LLE and SPE sample pretreatment procedures is 100.4 and 104.9%, respectively, at a 5 micrograms/ml drug concentration. The lower limit of quantitation is 0.01 microgram/ml for SPE and 0.25 microgram/ml for LLE. Stability data of paclitaxel in human urine are also presented.

Calibration↗

Determination of organochlorine pesticides in water using microwave assisted headspace solid-phase microextraction and gas chromatography.

A coupled technique, microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), was investigated for one-step in situ sample pretreatment for organochlorine pesticides (OCPs) prior to gas chromatographic determination. The OCPs, aldrin, o,p'-DDE, p,p'-DDE, o,p'-DDT, p,p'-DDT, dieldrin, alpha-endosulfan, beta-endosulfan, endosulfan sulfate, endrin, delta-HCH, gamma-HCH, heptachlor, heptachlor epoxide, methoxychlor and trifluralin were collected by the proposed method and analyzed by gas chromatography with electron-capture detection (GC-ECD). To perform the MA-HS-SPME, six types of SPME fibers were examined and compared. The parameters affecting the efficiency in MA-HS-SPME process such as sampling time and temperature, microwave irradiation power, desorption temperature and time were studied to obtain the optimal conditions. The method was developed using spiked water samples such as field water and with 0.05% humic acid in a concentration range of 0.05-2.5 microg/l except endosulfan sulfate in 0.25-2.5 microg/l. The detection was linear over the studied concentration range with r2>0.9978. The detection limits varied from 0.002 to 0.070 microg/l based on S/N=3 and the relative standard deviations for repeatability were <15%. A certified reference sample of OCPs in aqueous solution was analyzed by the proposed method and compared with the conventional liquid-liquid extraction procedure. These results are in good agreement. The results indicate that the proposed method provides a very simple, fast, and solvent-free procedure to achieve sample pretreatment prior to the trace-level screening determination of organochloride pesticides by gas chromatography.

Chromatography, Gas↗

Ca(2+) and calmodulin modulate DNA-binding activity of maize heat shock transcription factor in vitro.

DNA-binding activity of a maize heat shock transcription factor (HSF) was induced by heat shock of a whole cell extract at 44 degrees C. Addition of the calcium ion chelator EGTA reduced the binding of the HSF to heat shock element (HSE) in vitro. Re-addition of CaCl(2) to the sample pretreated with EGTA restored the ability of the HSF to bind to DNA. DNA-binding activity of the HSF was also induced by directly adding CaCl(2) to a whole cell extract at non-heat-shock temperature, but not by MgCl(2). During HS at 44 degrees C, calmodulin (CaM) antagonists chlorpromazine (CPZ) and N-(6-aminohexyl)-5-chloro-1-naphthalenesulfonamide (W7) inhibited DNA-binding activity of the HSF in a concentration-dependent manner, but N-(6-aminohexyl)-1-naphthalenesulfonamide (W5), an inactive structural analogue of W7, did not. Addition of antiserum specific to CaM reduced the binding of the HSF to HSE. Re-addition of CaM to the sample pretreated with antiserum could restore the binding activity of the HSF. DNA-binding activity of the HSF was promoted by directly adding CaM to a whole cell extract at 44 degrees C, but not by BSA. Moreover, at non-heat-shock temperature, DNA-binding activity of the HSF was also induced by directly adding CaM to a whole cell extract, but not by BSA. Our observations further confirm the role of Ca(2+) in activation of the HSF in plant and provide the first example of the role of CaM in regulation of DNA-binding activity of the HSF. These results suggest that Ca(2+) and CaM are involved in HSP gene expression likely through regulating the activity of the HSF.

Antibodies↗

Association between homocysteine and neopterin in healthy subjects measured by a simple HPLC-fluorometric method.

OBJECTIVES: Neopterin and homocysteine promote vascular smooth muscle cell proliferation through the activation of nuclear factor(kappa) B. The aim of this study was to investigate the relation between these two compounds in healthy subjects by a rapid HPLC-fluorometric method which simplifies sample pretreatment for the measurement of neopterin in serum. DESIGN AND METHODS: In 40 healthy subjects (45.9 +/- 2.1 yr, mean +/- SEM, 10 males, 30 females) serum neopterin concentrations were measured by HPLC-fluorometry and enzyme-linked immunusorbant assay-ELISA and the results were compared. Urinary neopterin and plasma total homocysteine concentrations were assayed by HPLC-fluorometry. RESULTS: Serum neopterin concentrations measured by HPLC and ELISA were 7.5 +/- 0.4 and 7.4 +/- 0.3 nmol/L, respectively, r = 0.92, p < 0.01. Urinary neopterin level was 163.9 +/- 11.0 nmol/mmol creatinine and plasma total homocysteine 7.6 +/- 0.4 micromol/L. A significant positive correlation was observed between serum neopterin and plasma total homocysteine (r = 0.59, p < 0.01). CONCLUSIONS: A simple and rapid sample pretreatment for the measurement of neopterin in serum has been introduced. The significant positive correlation between neopterin and homocysteine implies that, interference with leukocyte function might be a new possible mechanism for the deleterious effects of homocysteine on vascular function.

Adult↗

LC-atmospheric pressure chemical ionization-MS/ MS analysis of multiple illicit drugs, methadone, and their metabolites in oral fluid following protein precipitation.

A quantitative LC-APCI-MS/MS method for simultaneous determination of multiple illicit drugs, methadone, and their metabolites in oral fluid was developed and validated. Sample pretreatment was limited to acetonitrile protein precipitation. LC separation was performed in 25.5 min, with a total analysis time of 35 min. Identification and quantitation were based on selected reaction monitoring. Calibration by linear regression analysis utilized deuterated internal standards and a weighing factor 1/x. Limits of detection and lower limits of quantitation (LOQ) were established between 0.25 and 5 ng/ mL and 0.5-10 ng/mL, respectively. linearity was obtained with an average correlation coefficient (R2) of >0.99, over a dynamic range from the LOQ up to maximum 500 ng/mL The method demonstrated good accuracy, intra- and interbatch precision, recovery, and stability for all compounds. No oral fluid matrix effect was observed throughout the chromatographic run. Protein precipitation provided a fast and simple sample pretreatment, while LC-APCI-MS/MS proved to be a sensitive and rugged quantitative method for multiple illicit and legal drugs in oral fluid. The method proved to be suitable for the evaluation of oral fluid as an alternative matrix to urine for monitoring illicit drug use and for determining oral fluid methadone concentrations in pregnant opiate and/or cocaine addicts.

Humans↗

Immunoaffinity pre-column for selective on-line sample pre-treatment in high-performance liquid chromatography determination of 19-nortestosterone.

A liquid chromatographic column-switching system for automated sample pretreatment and determination of the anabolic hormone beta-19-nortestosterone (beta-19-NT) and its metabolite alpha-19-nortestosterone (19-norepitestosterone) in calf urine is described. The system consists of an immunoaffinity pre-column (immuno pre-column) packed with Sepharose-immobilized polyclonal antibodies against beta-19-NT, a second pre-column packed with C18 bonded silica and an analytical C18 column. Urine (25 ml) is directly loaded on the immuno pre-column, where the analytes of interest are trapped by the immobilized antibodies. Next the analytes are desorbed selectively with a solution containing an excess of the cross-reacting steroid hormone norgestrel and transferred, via the second pre-column, to the analytical column. The recovery of beta-19-NT in spiked urine samples was over 95%. The detection limit was 50 ng/l for a 25-ml urine injection. The system showed no loss of analytical performance over a 6-month period, during which about 100 samples were analysed with the same immuno pre-column. The general applicability of this sample pretreatment method is discussed.

Animals↗

Simultaneous determination of free mycophenolic acid and its glucuronide in serum of patients under mycophenolate mophetil therapy by ion-pair reversed-phase liquid chromatography with diode array UV detection.

An high performance liquid chromatography (HPLC)-UV method for the simultaneous determination of the free forms of mycophenolic acid (MPA) and its phenol glucuronide (MPAG) in human serum samples was developed for the first time. Chromatographic separation was performed on octadecylsilane based stationary phase in combination with a mobile phase of methanol/buffered tetrabutylammonium (TBA) salt mixture. Sample pretreatment consisted of an ultrafiltration step followed by clean-up/enrichment on a C(18) solid-phase extraction (SPE) cartridge. Average recoveries of (99.7 +/- 0.2)% and (64.1 +/- 6.9)% for free MPA and MPAG, respectively, were estimated in the concentration range from 0.5 to 10 microg/ml. The within-day and between-days coefficients of variation were 0.4 and 0.8% for free MPA (0.1 microg/ml spiking level) and 0.8 and 1.6% for free MPAG (5 microg/ml spiking level), respectively. The linear ranges for free MPA and MPAG were 0.06-1 and 0.2-10microg/ml, respectively. Detection limits of 4 and 17 ng/ml for free MPA and MPAG were estimated in spiked serum. The same HPLC method was also capable of a simultaneous determination of the total concentration of MPA and MPAG when coupled to a proper sample pretreatment step. The potential of the method is demonstrated by excretion kinetics measurement in serum of patients receiving MMF therapy.

Algorithms↗

Quantitative analysis of twelve sulfonamides in honey after acidic hydrolysis by high-performance liquid chromatography with post-column derivatization and fluorescence detection.

A quantitative HPLC-fluorescence method for the simultaneous determination of 12 sulfonamides (sulfaguanidine, sulfanilamide, sulfacetamide, sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamether, sulfamethazine, sulfamethoxypyridazine, sulfachloropyridazine and sulfadoxine) in honey was developed and validated. Sample pretreatment included acidic hydrolysis, followed by liquid-liquid extraction and solid-phase extraction on a strong cation exchanger. LC separation was performed in 45 min, with a total analysis time of 60 min. Identification and quantitation were based on retention time and fluorescence intensity, respectively. Peak area ratios of the target analytes and the internal standard were fit to a linear least-squares regression curve with a weighting factor of 1/x. Limits of detection and quantitation (LOQ) had values of 1 or 2 and 2 or 5 ng/g, respectively. Linearity was obtained with an average coefficient of determination (R2) higher than 0.997, over a dynamic range from the LOQ value up to 100ng/g. The method demonstrated good intra- and interbatch precision and accuracy. No interferences with the peaks of interest were observed throughout the chromatographic run. Sample pretreatment provided efficient cleanup, while post-column derivatization with fluorescamine proved to be a reproducible derivatization technique enabling a sensitive and rugged quantitative determination of sulfonamides.

Chromatography, High Pressure Liquid↗

Analysis of nitrate ion in nettle (Urtica dioica L.) by ion-pair chromatographic method on a C30 stationary phase.

Nitrate ion is a frequent pollutant not only in soil and natural water resources but in vegetables and foods as well. In our study we focused on nettle due to its increased ability to accumulate nitrate ions. A new, simple method for the separation and determination of nitrate ion based on reversed-phase ion-pair chromatography has been elaborated. A new four-step sample pretreatment method enables the precipitation of proteins and oxidative degradation of compounds that may disturb the identification of the nitrate ion: (1) extraction of the total nitrate content, (2) precipitation of proteins with acetonitrile, (3) oxidative degradation of the organic contaminants with H2O2, (4) evaporation of the solvent and taking up of the residue in water. The chromatographic separations were carried out on a high-density C30 stationary phase under isocratic conditions. The optimal mobile-phase composition was 10% (v/v) acetonitrile and 90% (v/v) 20 mmol L(-1) phosphate buffer, containing 2 mmol of tetrabutylammonium hydroxide at pH 6.0. The method could also be used for the separation of IO3(-), SeO3(2-), BrO3(-), NO2(-), Br-, SeO4(2-), and I- ions. The validated method is sensitive (the detection limit is 0.18 ng of nitrate ion). The method is linear in a high concentration range (0.031-30.66 microg mL(-1)). Recoveries varied between 98% and 103%. Reproducibility of the elaborated sample pretreatment method showed 1.54%. The method can be used for the determination of nitrate ion from different plants.

Beverages↗

Rapid analysis of inositol phosphates.

Fast and simple analytical methods for the determination of inositol bis- to hexakisphosphates or only inositol hexakisphosphate in foods and feces are presented. The methods are both faster and simpler with regard to analytical detection and sample pretreatment as compared to previously reported methods. The samples are pretreated using extraction and centrifugal ultrafiltration and analyzed using high-performance ion chromatography (HPIC) with gradient or isocratic elution. The analytes are detected using ultraviolet detection after postcolumn reaction. The methods are efficient, highly selective, and appropriate for analyzing inositol phosphates in food and feces samples. The between- and within-day variances were generally below 8 and 5% (relative standard deviation), respectively, for the presented HPIC method with gradient elution.

Chromatography, Ion Exchange↗

Sensitive inductively coupled plasma mass spectrometry assay for the determination of platinum originating from cisplatin, carboplatin, and oxaliplatin in human plasma ultrafiltrate.

We present a highly sensitive, rapid method for the determination of platinum originating from the anticancer agents cisplatin, carboplatin, and oxaliplatin in human plasma ultrafiltrate. The method is based on the quantification of platinum by inductively coupled plasma mass spectrometry and allows quantification of 7.50 ng l-1 platinum in only 150 microl of matrix. Sample pretreatment involves dilution of samples with 1% HNO3. Validation fulfilled the most recent FDA guidelines for bioanalytical method validation. Validated ranges of quantification were 7.50 ng l-1 to 1.00x10(5) ng l-1 in plasma ultrafiltrate for all three platinum compounds. The assay is now successfully used to support pharmacokinetic studies in cancer patients treated with cisplatin, carboplatin, or oxaliplatin.

Antineoplastic Agents↗

Urinary protein and enzyme excretion in patients receiving chemotherapy with the cis-platinum analogs carboplatin (CBDCA, JM8) and iproplatin (CHIP, JM9).

Urinary protein and enzyme excretion was measured in 33 patients with solid tumours receiving chemotherapy with the cis-platinum analogs carboplatin (JM8, CBDCA) and iproplatin (JM9, CHIP). The patients were given up to six courses of the drugs at 4-week intervals, and serial urine samples were collected weekly for periods up to 28 weeks. Overall there was no significant increase in the alkaline phosphatase (ALP), lactate dehydrogenase (LD), and N-acetyl glucosaminidase (NAG) excretion of the first posttreatment samples compared with the pretreatment samples. During the course of treatment there were transient increases in all three enzymes, some quite marked. There was no consistent increase in urinary protein or enzyme excretion during the period of treatment, suggesting that there was no cumulative nephrotoxicity. There was no change in creatinine clearance or urinary beta 2-microglobulin content. Iproplatin appeared marginally more toxic on the basis of elevated NAG and ALP during the second half of the treatment periods compared with the first (P less than 0.01 and less than 0.025, respectively).

Acetylglucosaminidase↗

Quantification of paclitaxel metabolites in human plasma by high-performance liquid chromatography.

A reversed-phase high-performance liquid chromatographic (HPLC) method has been validated for the quantitative determination of the three major paclitaxel metabolites (6 alpha-hydroxypaclitaxel, 3'-p-hydroxypaclitaxel, 6 alpha,3'-p-dihydroxypaclitaxel) in human plasma. The HPLC system consists of an APEX-octyl analytical column and acetonitrile-methanol-0.02 M ammonium acetate buffer pH 5 (AMW; 4:1:5, v/v/v) as the mobile phase. Detection is performed by UV absorbance measurement at 227 nm. The sample pretreatment of the plasma samples involves solid-phase extraction (SPE) on Cyano Bond Elut columns. The concentrations of the metabolic products could be determined by using the paclitaxel standard curve with a correction factor of 1.14 for 6 alpha,3'-p-dihydroxypaclitaxel. The recoveries of paclitaxel and the metabolites 6 alpha,3'-p-dihydroxypaclitaxel, 3'-p-hydroxypaclitaxel and 6 alpha-hydroxypaclitaxel in human plasma were 89, 78, 91 and 89%, respectively. The accuracy of the assay for the determination of paclitaxel and its metabolites varied between 95 and 97%, at a 50 ng/ml analyte concentration. The lower limit of quantitation was 10 ng/ml for both the parent drug and its metabolites.