PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “multiplex imaging”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Producing STR locus patterns from bloodstains and other forensic samples using an infrared fluorescent automated DNA sequencer.

Short tandem repeat (STR) analysis is increasingly being used in forensic case analysis because of the large number of STR loci in the human genome and their highly polymorphic nature. An automated DNA sequencer using high sensitivity infrared (IR) fluorescence technology was used to detect STR allele patterns from simulated forensic samples. The amplification strategy used a 19 base pair extension on the 5' end of one of the PCR primers. This sequence is identical to the sequence of a universal M13 Forward sequencing primer which is included in the amplification reaction. Allelic bands were detected by incorporation of the M13 primer-fluorescent dye conjugate into PCR products thus eliminating the need for direct conjugation of fluorescent dye to individual STR primers. By using an IR-based automated DNA sequencer and Tth DNA polymerase, polymorphic STR alleles were detected on-line rapidly and efficiently from bloodstains using only a high temperature incubation to extract DNA from blood cells. Five STR loci were also amplified using Chelex extracted DNA from simulated forensic samples. Multiplexing of three primer pairs in a single PCR mixture for amplification was accomplished using Taq polymerase. This system combines IR fluorescence chemistry and laser technology thus eliminating the need for radioactivity and the gel handling required with silver staining and fluor detection systems. Real-time detection permits immediate visualization of the data and STR alleles are displayed as familiar autoradiogramlike images that can be analyzed by computer. By loading a 64 lane gel twice and multiplexing with three primer pairs, forensic scientists can type at least three loci from 120 samples in one day.

Alleles↗

Scene-based nonuniformity correction technique that exploits knowledge of the focal-plane array readout architecture.

Spatial fixed-pattern noise is a common and major problem in modern infrared imagers owing to the nonuniform response of the photodiodes in the focal plane array of the imaging system. In addition, the nonuniform response of the readout and digitization electronics, which are involved in multiplexing the signals from the photodiodes, causes further nonuniformity. We describe a novel scene based on a nonuniformity correction algorithm that treats the aggregate nonuniformity in separate stages. First, the nonuniformity from the readout amplifiers is corrected by use of knowledge of the readout architecture of the imaging system. Second, the nonuniformity resulting from the individual detectors is corrected with a nonlinear filter-based method. We demonstrate the performance of the proposed algorithm by applying it to simulated imagery and real infrared data. Quantitative results in terms of the mean absolute error and the signal-to-noise ratio are also presented to demonstrate the efficacy of the proposed algorithm. One advantage of the proposed algorithm is that it requires only a few frames to obtain high-quality corrections.

Algorithms↗

A generic particle-based nonradioactive homogeneous multiplex method for high-throughput screening using microvolume fluorimetry.

We have developed a novel fluorescence-based homogeneous binding assay for high-throughput screening of chemical compounds. In this assay, a Cy5- or Cy5.5-labeled ligand binds to receptor immobilized on a particle, either a bead or a cell. The resulting localized signal can be detected by a modified microvolume fluorimeter (MVF). When a molecule which competes with the labeled ligand is present, the localized fluorescence on cells or beads is reduced. Image processing software enumerates events and analyzes fluorescence intensity. We describe MVF assays for the IL-1 and IL-5 receptors. Using synthetic peptides with a range of affinities for the IL-1 receptor, we obtained IC(50) data consistent with those determined by radioligand binding assays. Because the image processing software can discriminate among events with different diameters, we were able to develop a multiplex assay, in which the IL-1R and IL-5R assays were carried out in the same well with each receptor immobilized on a different size of bead. IC(50) values generated in the multiplex assay for ligands specific to each receptor were comparable to those determined independently. Finally, similar IC(50) values were obtained in a 16-microl volume in an 864-well plate. This homogeneous, nonradioactive, miniaturizable, and multiplex-capable assay holds much promise for screening of combinatorial libraries and compound collections.

Animals↗

Space-multiplexed multifocal nonlinear microscopy.

Standard forms of nonlinear microscopy rely on single beam scanning, but the usually weaker signal and the need to image in real-time call for parallelization of the image formation. Since the nonlinear susceptibilities necessitate a comparatively large illumination power, with current laser systems the brightness or field of view of any parallelized nonlinear microscope is limited by the brightness of the laser. For example, by producing an array of high aperture foci, multifocal multiphoton microscopy (MMM) provides real-time, light-efficient three-dimensional fluorescence imaging at high-resolution. The available power limits the degree of parallelization and hence codetermines the field of view. As the utilization of all the laser power is imperative, the focal intensity can be adjusted only through altering the number of foci. This compromises to some extent the flexibility to adjust the focal intensity to benign and effective levels. Here we introduce space-multiplexing (SMX) as a novel option in parallelized nonlinear microscopy, which enables an improved exploitation of the total laser power and facilitates changing the intensity levels in selected regions, without attenuating the total laser power. The basic idea of SMX is to overlap arrays of slightly offset coherent focal fields whose interference modulates the intensity across the sample. For a given degree of parallelization and power, SMX increases the two- and three-photon excited signal of parallelized nonlinear microscopy by a factor of up to 1.5 and 2.5, respectively. To some extent, sensitive regions may be spared out, whereas in regions with weaker nonlinear susceptibilities the intensity is increased. SMX is relevant to all modes of nonlinear microscopy, including parallelized second- and third-harmonic imaging, coherent anti-Stokes Raman scattering, and wide field multiphoton excitation.

Journal Article↗

Cerebellar volume in offspring from multiplex alcohol dependence families.

BACKGROUND: Increased susceptibility for developing alcohol dependence (AD) might be related to structural differences in brain circuits that influence the salience of rewards and/or modify the efficiency of information processing. The role of the cerebellum in regulating cognitive functions is being increasingly recognized along with its well-known influence on motor performance. Additionally, developmental changes in cerebellar volume during adolescence have been reported. METHODS: Magnetic resonance imaging was used to measure the cerebellum in 17 high-risk adolescent and young adult offspring from multiplex alcohol dependence families and 16 control subjects matched for gender, age, and IQ. RESULTS: High-risk (HR) adolescents/young adults showed increased total cerebellum volume and total grey in comparison with control subjects. Age-related decreases in total grey volume were seen with age, a pattern that was not seen in HR offspring. CONCLUSIONS: Offspring from multiplex families for AD manifest genetic susceptibility by having larger cerebellar volume, which seems to be related to lesser grey matter pruning for age. Larger cerebellar volumes in adult obsessive compulsive disorder (OCD) patients have been reported. This suggests a possible similarity in structural underpinnings for alcohol dependence and OCD.

Adolescent↗

Nanodiagnostics: a new frontier for clinical laboratory medicine.

BACKGROUND: The use of nanotechnologies for diagnostic applications shows great promise to meet the rigorous demands of the clinical laboratory for sensitivity and cost-effectiveness. New nanodiagnostic tools include quantum dots (QDs), gold nanoparticles, and cantilevers. QDs, which are the most promising nanostructures for diagnostic applications, are semiconductor nanocrystals characterized by high photostability, single-wavelength excitation, and size-tunable emission. QDs and magnetic nanoparticles can be used for barcoding of specific analytes. Gold and magnetic nanoparticles are key components of the bio-barcode assay, which has been proposed as a future alternative to the PCR. METHODS: We examined articles published over the past 10 years investigating the use of QDs, gold nanoparticles, cantilevers, and other nanotechnologies in promising diagnostic applications. RESULTS: Several nanodiagnostic assays have been developed, including a QD-based assay capable of detecting biotinylated prostate-specific antigen (PSA) at 0.38 ng/L, a bio-barcode assay capable of detecting 30 amol/L PSA in a 10-microL sample, and another able to detect 50 molecules of the Alzheimer marker amyloid beta-derived diffusible ligand in 10 microL of cerebrospinal fluid. CONCLUSIONS: Nanodiagnostics promise increased sensitivity, multiplexing capabilities, and reduced cost for many diagnostic applications as well as intracellular imaging. Further work is needed to fully optimize these diagnostic nanotechnologies for clinical laboratory setting and to address the potential health and environmental risks related to QDs.

Clinical Chemistry Tests↗

Microwave imaging of tissue blood content changes.

Active microwave imaging gives information on the dielectric properties of of the body, allowing the collection of data that are distinct from, but complementary to, those available from other imaging methods based on different radiations. Two types of microwave imaging systems have been developed. The first is a planar system that irradiates the object with a plane wave and collects scattered phase and amplitude data at 1024 points on a parallel plane. The data can be reconstructed using a back propagation technique to give an image of the object. The second type of system is a tomographic scanner, consisting of a multiplexed 64-element circular array of waveguides. The waveguides are electronically scanned, alternately as sources and receivers, to give a complete scan of the object with no mechanical movement. A tomographic 'slice' of the object is reconstructed using spectral domain interpolation. Both systems work at 2.45 GHz with an incident power less than 1 mW cm-2 at the object and require a coupling medium (usually water) between the object and the source/receiver. Imaging parameters are appropriate for clinical use: a spatial resolution of 1 cm, measurement time of a few seconds and contrast resolution of around 1%. The effects of changes in perfusion on images of isolated animal organs are presented. Images have also been obtained, with both systems, of the internal dielectric structure of the forearm and of variations in dielectric properties due to changes of tissue blood content effected by application and release of tourniquets to the upper arm. Results show that these changes are well demonstrated by microwave imaging, and possible clinical applications are discussed.

Animals↗

Multiplex detection and quantitation of proteins on western blots using fluorescent probes.

The uses of multiplex detection methodologies are dramatically increasing as a means to increase sample throughput and to demonstrate quantitative differences between multiple targets in gene or protein expression analysis. In this study, we investigate the application of multiplex fluorescent detection for three proteins on the same Western blot using a laser-scanning imaging system, the Bio-Rad Molecular Imager FX. We show that independent detection and quantitation of multiple targets is achievable with little or no correction for fluorescent crosstalk by using fluorescent tags preferentially excited with different laser lines and detected at wavelengths that minimize fluorescence crosstalk. We demonstrate that the use of fluorescent detection methods can provide a tenfold greater quantifiable range but with two- to fourfold less sensitivity than chemiluminescent detection methodologies. Two examples of three-color multiplex detection using FITC-, Cy3- and Cy5-conjugated probes on Western blots are provided to demonstrate applications of this approach.

Actins↗

Low-cost acquisition of video images simultaneously with 240 electrophysiological signals.

We developed a low-cost system for simultaneous collection and storage of physiological and video signals. The system samples and multiplexes up to 240 low-bandwidth analog channels with a camera video signal, and outputs a standard composite video signal containing analog and video data. The combined signals can be stored on video tape or can be digitized by an inexpensive framegrabber. The circuitry separates horizontal synchronizing pulses from a camera output; the pulses increment a counter that sequentially selects each electrophysiological channel on a sample-and-hold multiplexer. The intensity of each horizontal scan line from the multiplexer output represents the amplitude of one sample of each physiological channel. This signal is then multiplexed with the video signal, such that a portion of each video horizontal line represents the physiological data. The combined output is stored together, providing a means for synchronizing the two signals during analysis. The design allows easy coordination of electrophysiological events with video images from a standard video camera, avoiding the necessity for separate analog to digital circuitry for physiological and video signal storage on computer media, as well as the need for complex synchronization of the data from different media.

Costs and Cost Analysis↗

Coherent-array imaging using phased subarrays. Part I: basic principles.

The front-end hardware complexity of a coherent array imaging system scales with the number of active array elements that are simultaneously used for transmission or reception of signals. Different imaging methods use different numbers of active channels and data collection strategies. Conventional full phased array (FPA) imaging produces the best image quality using all elements for both transmission and reception, and it has high front-end hardware complexity. In contrast, classical synthetic aperture (CSA) imaging only transmits on and receives from a single element at a time, minimizing the hardware complexity but achieving poor image quality. We propose a new coherent array imaging method--phased subarray (PSA) imaging--that performs partial transmit and receive beam-forming using a subset of adjacent elements at each firing step. This method reduces the number of active channels to the number of subarray elements; these channels are multiplexed across the full array and a reduced number of beams are acquired from each subarray. The low-resolution subarray images are laterally upsampled, interpolated, weighted, and coherently summed to form the final high-resolution PSA image. The PSA imaging reduces the complexity of the front-end hardware while achieving image quality approaching that of FPA imaging.

Computer Simulation↗

Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function.

The UCLH Mark 1b is a portable EIT system that can address up to 64 electrodes, which has been designed for imaging brain function with scalp electrodes. It employs a single impedance-measuring circuit and multiplexer so that electrode combinations may be addressed flexibly using software. It operates in the relatively low frequency band between 225 Hz and 77 kHz, as lower frequencies produce larger changes during brain activity, and has a videocassette-sized headbox on a lead 10 m long, connected to a base box the size of a video recorder, and notebook PC, so that recordings may be made in ambulant subjects. Its performance was assessed using a resistor-capacitor network, and two saline-filled tanks-a cylindrical Perspex one and a latex one which contained a human skull. System signal-to-noise ratio was better than 50 dB and the maximum reciprocity error less than 10% for most frequencies. The CMMR was better than 80 dB at 38 kHz and a sponge, 20 mm across, which caused a local 12% impedance increase, was correctly localized in images. This suggests that the system has adequate performance to image impedance changes of 5-50% known to occur in the brain during normal activity, epilepsy or stroke; clinical trials to image these conditions are in progress.

Brain↗

Comparison of gene expression in squamous cell carcinoma and adenocarcinoma of the uterine cervix.

OBJECTIVES: Microarray expression analysis of cervical tumors has revealed differential expression of genes that may be useful as markers or targets for treatment. We question the application of array findings across the major categories of cervical cancer. We sought to identify differences between normal squamous epithelium (NSQ) and glandular epithelium (NGL) of the uterine cervix and their malignant variants: squamous cell cancer (SCC) and adenocarcinoma (ACA). METHODS: Eight genes were selected: 12-lipoxygenase (12-LOX), keratin 4, trypsinogen 2 (TRY2), Rh glycoprotein C (RhGC), collagen type V alpha 2, integrin alpha 5, integrin alpha 6, and c-myc. Ten cases each of SCC and ACA of the cervix were selected from our tumor bank. NSQ and NGL epithelia were obtained from consecutive patients undergoing surgery for benign disease. RNA extraction, cDNA synthesis, and DNA amplification of all samples were performed according to an established protocol. Electrophoresis of the multiplexed polymerase chain reaction (PCR) products was performed under standard conditions, followed by digital image capture. A ratio of target to control gene (beta-actin) was obtained for each sample. Analysis of variance was applied to the mean ratios for each tissue to establish significant differences. Individual pairwise comparisons were made by Student t tests and verified with the Tukey-Kramer test. RESULTS: Clinically valid comparisons are NSQ to NGL, NSQ to SCC, NGL to ACA, and SCC to ACA. Various expression patterns were observed between the epithelia and their malignant phenotypes. Significant differences in gene expression were observed between benign squamous and glandular epithelium in four of the eight genes and between malignant squamous and glandular epithelium in three of the eight genes. Significant differences in gene expression between benign and malignant tissues were demonstrated in four of the eight genes. CONCLUSIONS: We have defined significant differential expression changes between the two principal cervical tumor types. Differences in genes are demonstrated and must be considered if array technology is applied to the study of the biologic behavior of these tumors as well as their screening and management. The observed differential expression should be a compelling argument to perform type-specific expression analysis for other tumors with histological variants.

Adenocarcinoma↗

Genome scale mapping of brain gene expression.

Two new approaches, voxelation and gene expression tomography (GET), permit multiplex acquisition of gene expression patterns in the brain. Both methods result in volumetric images of gene expression analogous to those produced in biomedical imaging systems. Voxelation employs analysis of spatially registered cubes from the brain, whereas GET entails analysis of parallel slices obtained by rotation about multiple axes. These methods have been used to investigate neurologic diseases and their models in both humans and mice. The results of these studies are discussed, as is the future of high-throughput gene expression mapping in the brain.

Animals↗

Direct visualization of cystic fibrosis transmembrane regulator mutations in the clinical laboratory setting.

BACKGROUND: The recommendation for population- based cystic fibrosis (CF) carrier screening by the American College of Medical Genetics for the 25 most prevalent mutations and 6 polymorphisms in the CF transmembrane regulatory gene has greatly increased clinical laboratory test volumes. We describe the development and technical validation of a DNA chip in a 96-well format to allow for high-throughput genotype analysis. METHODS: The CF Portrait chip contains an 8 x 8 array of capture probes and controls to detect all requisite alleles. Single-tube multiplex PCR with 15 biotin-labeled primer pairs was used to amplify sequences containing all single-nucleotide polymorphisms to be interrogated. Detection of a thin-film signal created by hybridization of multiplex PCR-amplified DNA to complementary capture probes was performed with an automated image analysis instrument, NucleoSight. Allele classification, data formatting, and uploading to a laboratory information system were fully automated. RESULTS: The described platform correctly classified all mutations and polymorphisms and can screen approximately 1300 patient samples in a 10-h shift. Final validation was performed by two separate 1000-sample comparisons with Roche CF Gold line probe strips and the Applera CF OLA, Ver 3.0. The CF Portrait Biochip made no errors during this validation, whereas the Applera assay made seven miscalls of the IVS-8 5T/7T/9T polymorphism CONCLUSIONS: The CF Portrait platform is an automated, high-throughput, DNA chip-based assay capable of accurately classifying all CF mutations in the recommended screening panel, including the IVS-8 5T/7T/9T polymorphism.

Autoanalysis↗

Multispectral imaging in biology and medicine: slices of life.

Multispectral imaging (MSI) is currently in a period of transition from its role as an exotic technique to its being offered in one form or another by all the major microscopy manufacturers. This is because it provides solutions to some of the major challenges in fluorescence-based imaging, namely ameliorating the consequences of the presence of autofluorescence and the need to easily accommodate relatively high levels of signal multiplexing. MSI, which spectrally characterizes and computationally eliminates autofluorescence, enhances the signal-to-background dramatically, revealing otherwise obscured targets. While this article concentrates on examples derived from liquid-crystal tunable filter-based technology, the intent is to showcase the advantages of multispectral imaging in general. Some technologies used to generate multispectral images are compatible with only particular optical configurations, such as point-scanning laser confocal microscopy. Band-sequential approaches, such as those afforded by liquid-crystal tunable filters (LCTFs), can be conveniently coupled with a variety of imaging modalities, which, in addition to fluorescence microscopy, include brightfield (nonfluorescent) microscopy as well as small-animal, noninvasive in-vivo imaging. Brightfield microscopy is the chosen format for histopathology, which relies on immunohistochemistry to provide molecularly resolved clinical information. However, in contrast to fluorescent labels, multiple chromogens, if they spatially overlap, are much harder to separate and quantitate, unless MSI approaches are used. In-vivo imaging is a rapidly growing field with applications in basic biology, drug discovery, and clinical medicine. The sensitivity of fluorescence-based in-vivo imaging, as with fluorescence microscopy, can be limited by the presence of significant autofluorescence, a limitation which can be overcome through the utilization of MSI.

Animals↗

CSF protein profiling using Multiplex Immuno-assay: A potential new diagnostic tool for leptomeningeal metastases.

OBJECTIVE: The diagnosis of leptomeningeal metastases (LM) is based on clinical symptoms, magnetic resonance imaging (MRI) of brain and spine and cytological analysis of cerebrospinal fluid (CSF). The clinical picture of LM is highly variable and both cytological CSF analysis and contrast-enhanced MRI are limited in sensitivity. More sensitive tools are needed to diagnose LM. We measured a profile of proteins involved in adhesion and inflammation in the CSF of LM and control patients and determined their potential diagnostic value for LM. PATIENTS AND METHODS: Using Multiplex Immuno-Assay (MIA), the CSF concentrations of nine soluble adhesion molecules, cyto- and chemokines were measured in patients with cytologically proven LM (n = 57) and control patients with a systemic malignancy (n = 20), aseptic/viral meningitis (n = 11) or other (non-)neurological diseases (n = 19). RESULTS: We found high CSF levels of soluble Vascular Cell Adhesion Molecule-1 (sVCAM-1), soluble Intercellular Adhesion Molecule-1 (sICAM-1), Interleukin-8 (IL-8), Pulmonary and Activation Regulated Chemokine (PARC), Interleukin-18 (IL-18) and Interferon-gamma inducible protein (IP-10) in patients with LM. The CSF protein profile in LM patients differed significantly from the profile found in control patients. Multivariate logistic regression and ROC analysis showed that the MIA-measured CSF protein profile has an additive discriminating value for LM above standard CSF parameters. A combination of total protein, glucose, IL-8, PARC and IP-10 CSF levels proved to be most discriminative between LM and non-LM patients. CONCLUSION: Our results warrant a prospective study to determine whether a CSF protein profile, including IL-8, PARC and IP-10 has diagnostic value compared with CSF cytology, the golden standard for LM.

Adult↗

Practical realization of high-speed photodisplacement imaging by use of parallel excitation and parallel heterodyne detection: a numerical study.

A new parallel photodisplacement technique that achieves extremely high-throughput imaging is proposed, and its practical realization is studied numerically. In this technique, a linear region of photothermal displacement is excited by use of a line-focusing intensity-modulated laser beam and detected with a parallel heterodyne interferometer in which a charge-coupled device linear image sensor is used. Because of the integration and sampling effects of the sensor, the interference light is spatiotemporally multiplexed. To extract the photodisplacement component from the multiplexed sensor signal, a scheme of phase-shifting light integration under an undersampling condition is proposed for parallel interferometry. The frequencies of several control signals, including the heterodyne beat signal, modulation signal, and sensor gate signal, are optimized so as to eliminate undesirable components, allowing only the displacement component to be extracted. Preliminary numerical simulation results show that the proposed technique has the potential to perform photodisplacement imaging more than 10,000 times faster than conventional photoacoustic microscopy.

Journal Article↗

Simultaneous imaging of proton and fluorine at moderate field.

Simultaneous imaging of proton and fluorine nuclei distributed in a unique sample has been performed by multiplexing the receiver coil's frequency for nmr signal acquisition. Implementation of the technique and modifications of a conventional spectrometer are described for operating at 0.13 T.

Analog-Digital Conversion↗