PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microbubbles”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100Linked to original sources

Lexicon of terms.

Explore the source record for details and available documents.

Microbubbles↗

An in vivo rat model simulating imaging of human kidney by diagnostic ultrasound with gas-body contrast agent.

One kidney of anesthetized rats was imaged by diagnostic ultrasound with contrast agent under conditions simulating both the geometry and the attenuation encountered during human perfusion imaging. Contrary to earlier predictions, glomerular capillary rupture with blood loss into Bowman's space and proximal tubules occurred in our clinically relevant model system. Quantitative analysis of histologic sections showed that 37 +/- 5% of the glomeruli at the center of the scan plane had blood cells in Bowman's space after imaging for 1 min with 1.8 MPa (mechanical index equivalent, MIe = 1.5) with a 1 s image trigger interval during IV injection of 10 microl/kg/min of Definity contrast agent (as recommended by the manufacturer). This percentage decreased rapidly with decreasing peak rarefactional pressure amplitude to an apparent threshold of 0.73 MPa (MIe = 0.6). The percentage of glomeruli with hemorrhage decreased in proportion to dose when reduced below the recommended value, but leveled-off at doses above it. The percentage of glomerular hemorrhage increased with increasing numbers of image exposures, with an initial rate of 1.1% per image. The glomerular hemorrhage also depended on the frame trigger interval with no hemorrhage evident for continuous imaging but a maximal effect for trigger intervals greater than about 1 s. These results indicated that there is a potential for clinical diagnostic ultrasound with contrast agent to induce glomerular hemorrhage.

Animals↗

Blood flow occlusion via ultrasound image-guided high-intensity focused ultrasound and its effect on tissue perfusion.

This study investigated the induction of tissue necrosis by arterial blood flow occlusion using ultrasound image-guided high-intensity focused ultrasound (HIFU). We constructed a prototype HIFU transducer in combination with an imaging probe that provided color Doppler imaging and ultrasound contrast imaging. The HIFU beam was aimed into a branch of the renal artery in vivo. The renal artery branches of eight rabbits were occluded by HIFU at an intensity of 4 kW/cm(2) (from 2 to 10 times of each sonication for 5 s). When the HIFU exposure was successful, complete cessation of blood flow was observed by color Doppler imaging with success rate of 100% (8/8). Furthermore, lack of perfusion was observed in the renal cortex with a contrast-enhanced image. Postmortem histologic evaluation showed a wedge-shaped area of infarction in six of seven cases, corresponding to the lack of the contrast medium in the ultrasound image. These results demonstrated that ultrasound image-guided HIFU can be used to induce arterial occlusion, thus producing infarction and necrosis of the perfused tissue.

Albumins↗

The use of a micro-bubble agent to enhance rabbit liver destruction using high intensity focused ultrasound.

Liver tissues in New Zealand rabbits were ablated using high intensity focused ultrasound (HIFU, 14300 W/cm(2), 1.0 MHz). The animals were intravenously administered 0.2 ml of micro-bubble agent in the experimental (n=20) group and an isovolumetric normal saline solution in the control (n=27) group before HIFU treatment which was performed as a linear scan. In both groups, the preselected tissue volumes were destroyed without harming the overlying tissues. Necrosis rate (NR, cm(3)/s) was used to reflect the ablation efficiency, which was the tissue volume of occurring coagulative necrosis per 1s HIFU exposure. NR was improved in the experimental group (0.0570+/-0.0433 vs 0.0120+/-0.0122, P=0.0002). Pathological studies confirmed that there were no residual intact targets within the exposed volume. These findings suggested that the introduction of the micro-bubble agent enhanced HIFU liver destruction.

Animals↗

A careful physical analysis of gas bubble dynamics in xylem.

Many studies have confirmed that cavitation in xylem is caused by air bubbles. Recently Shen et al. (Tree Physiol. 22 (2002) R655), analysed the expansion of a pre-existent bubble in xylem and one formed by air seeding. The present paper makes a further analysis of bubble expansion by the equilibrium criterion of the Helmholtz function. It has been proved that when xylem pressure P'l decreases to a special value P'l* from a value higher than, or equal to, or lower than -Po (Po is atmospheric pressure), an air bubble in xylem can grow up steadily, corresponding to minimums of the Helmholtz function F(r). As soon as P'l is lower than P'l*, since F(r) will be a decreasing function when P'l < P'l*, resulting in non-equilibrium of the bubble, it will break inducing a cavitation event. The analysis is consistent with the results of mechanism. Given P'l > or = -3Po, if an air bubble could enter a conduit, it would be in a stable equilibrium. When P'l < -3Po an air bubble entering a conduit will be in an unstable equilibrium. As the water further vaporizes, it will break at once. This is the case to which the former published formula P'l = -2sigma/rp is applicable.

Gases↗

Nonlinear imaging.

Explore the source record for details and available documents.

Contrast Media↗

Breast.

Explore the source record for details and available documents.

Breast Neoplasms↗

The influence of xenon, nitrous oxide and nitrogen on gas bubble expansion during cardiopulmonary bypass.

BACKGROUND AND OBJECTIVE: Xenon may have favourable applications in the setting of cardiac surgery. Its advantages include a desirable haemodynamic profile as well as potential cardiac and neuroprotective properties. However, its low solubility may lead to enhanced diffusion into enclosed gas spaces. The purpose of this study was to compare the effects of xenon (Xe), nitrous oxide (N2O) and nitrogen (N2) on gas bubble size during cardiopulmonary bypass (CPB). METHODS: Rats were randomized to receive 70% Xe, 26% oxygen (O2), 4% carbon dioxide (CO2) (xenon group); 70% N2O, 26% O2, 4% CO2 (nitrous oxide group) or 70% N2, 26% O2, 4% CO2 (nitrogen group) during 90 min of normothermic CPB. Small gas bubbles (300-500 microL; n = 12 per group) were injected into a bubble chamber on the venous side of the bypass circuit. After 10 min of equilibration, they were removed for volumetric analysis. RESULTS: The increase in bubble size was 2 +/- 2% with nitrogen, 17 +/- 6% with xenon (P = 0.0192 vs. nitrogen) and 63 +/- 23% with nitrous oxide (P = 0.0001 vs. nitrogen). The nitrous oxide group had significantly increased bubble size compared to the xenon group (P = 0.0001). CONCLUSIONS: During CPB, xenon anaesthesia produced a small increase in gas bubble size compared to nitrogen. Nitrous oxide resulted in significantly larger bubbles compared to both nitrogen and xenon.

Analysis of Variance↗

Nonequilibrium bubbles in a flowing langmuir monolayer.

We investigate the nonequilibrium behavior of two-dimensional gas bubbles in Langmuir monolayers. A cavitation bubble is induced in liquid expanded phase by locally heating a Langmuir monolayer with an IR-laser. At low IR-laser power the cavitation bubble is immersed in quiescent liquid expanded monolayer. At higher IR-laser power thermo capillary flow around the laser-induced cavitation bubble sets in. The thermo capillary flow is caused by a temperature dependence of the gas/liquid line tension. The slope of the line tension with temperature is determined by measuring the thermo capillary flow velocity. Thermodynamically stable satellite bubbles are generated by increasing the surface area of the monolayer. Those satellite bubbles collide with the cavitation bubble. Upon collision the satellite bubbles either coalesce with the cavitation bubble or slide past the cavitation bubble. Moreover we show that the satellite bubbles can also be produced by the emission from the laser-induced cavitation bubbles.

Capillary Action↗

Selectin ligands promote ultrasound contrast agent adhesion under shear flow.

Contrast-enhanced ultrasound imaging has shown promise in the field of molecular imaging. This technique relies upon the adhesion of ultrasound contrast agent (UCA) to targeted molecular markers of disease. This is accomplished by coating the surface of the contrast agent with a ligand that specifically binds to the intended molecular marker. Most UCA particles remain in the blood space, and their retention is influenced by the forces imposed by blood flow. For a UCA bound to a molecular target on the vascular endothelium, blood flow imposes a dislodging force that counteracts retention. Additionally, contrast agent adhesion to the molecular marker requires rapid binding kinetics, especially in rapid blood flow. The ability of a ligand:target bond complex to mediate fast adhesion and withstand dislodging force is necessary for efficient ultrasound-based molecular imaging. In the current study, we describe a flow-based adhesion assay which, combined with a novel automated tracking algorithm, enables quick determination of the ability of a targeting ligand to mediate effective contrast agent adhesion. This system was used to explore the adhesion of UCA targeted to the proinflammatory endothelial protein P-selectin via four targeting ligands, which revealed several interesting adhesive behaviors. Contrast agents targeted with glycoconjugate ligands modeled on P-selectin glycoprotein ligand 1 exhibited primarily unstable or transient adhesion, while UCA targeted with an anti-P-selectin monoclonal antibody exhibited primarily firm adhesion, although the efficiency with which these agents were recruited to the target surface was relatively low.

Adhesiveness↗

Refine your search to explore more results.