PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Anatomic Landmarks”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Intracardiac echocardiography during radiofrequency catheter ablation of cardiac arrhythmias in humans.

OBJECTIVES: The purpose of this study was to describe our preliminary experience using catheter-based intracardiac echocardiography as an adjunct to biplane fluoroscopy for guiding radiofrequency catheter ablation of atrial arrhythmias in the right side of the heart. BACKGROUND: Catheter ablation requires precise positioning and stable ablation electrode-endocardial contact. This procedure is currently guided by an analysis of intracardiac electrograms and fluoroscopy. However, the use of fluoroscopy does not allow the endocardium and certain anatomic landmarks to be identified and is associated with the hazards of radiation exposure. METHODS: Seventeen symptomatic patients were studied. A 10F 10-MHz intracardiac imaging catheter was used to visualize specific anatomic landmarks in the right atrium for directing the ablation electrode in 15 patients undergoing radiofrequency ablation of 19 arrhythmias and to assist with interatrial septal puncture in 3 patients. RESULTS: Continuous intracardiac imaging was performed for a mean +/- SD of 63.6 +/- 39.2 min and demonstrated distal electrode-endocardial tissue contact in 81 (60%) of 134 radiofrequency applications. Movement of the catheter was demonstrated during 36 (44%), microcavitations during 39 (48%) and thrombus during 15 (19%) of the 81 imaged applications. In 7 of 10 procedures for atrial flutter, successful ablation was directed at anatomic corridors in the right atrium visualized with intracardiac echocardiography. During ablation of atrial tachycardia, imaging identified abnormal atrial anatomy related to previous surgery and guided successful ablation of a reentrant tachycardia circulating around these anatomic obstacles. In two procedures for slow pathway modification of atrioventricular node reentrant tachycardia, intracardiac echocardiography confirmed catheter stability at the tricuspid annulus anterior to the coronary sinus. CONCLUSIONS: During catheter ablation, intracardiac echocardiography augments fluoroscopy by visualizing anatomic landmarks, ensuring stable endocardial contact and assisting in transseptal puncture. Ablation of typical atrial flutter can be successfully directed at anatomic corridors identified using intracardiac imaging.

Atrial Flutter↗

Construction of local vertebral coordinate systems using a digitizing probe. Technical note.

STUDY DESIGN: When studying three-dimensional motion of multiple-vertebra spine segments in vitro, it is often desirable to report the kinematics at the individual vertebral levels in terms of each level's local coordinates systems. A novel technique is described for constructing local vertebral coordinate axes using a standard digitizing probe. OBJECTIVES: To describe a technique that was developed to allow researchers to relate vertebral landmarks to optical markers and to set the local coordinate axes of several vertebrae accurately through a short, simple procedure performed only once at the beginning of a spine testing experiment. SUMMARY OF BACKGROUND DATA: Other researchers have used radiographs and careful marker placement for establishing the coordinate systems of vertebrae and the relationships of anatomic landmarks to optical markers. The authors found no publications giving details of how vertebral coordinate systems are established from anatomic landmarks. METHODS: A digitizing probe is used to identify vertebral landmarks and to relate these landmarks to optical markers attached to the vertebrae. An algorithm is described whereby vertebral coordinate axes are constructed from the landmarks. RESULTS: The method described has been implemented successfully in a computerized in vitro spinal flexibility testing system that plots each individual motion segment's load-deformation curves in real time during experimentation. The proposed technique is less labor intensive and error prone than the earlier methods because landmarks are identified directly. CONCLUSIONS: The described technique quickly, easily, and accurately relates anatomic landmarks to optical markers and constructs local coordinate axes, two steps that are necessary before monitoring the kinematics of individual motion segments during multilevel spine testing.

Algorithms↗

The deltopectoral triangle as a landmark for percutaneous infraclavicular cannulation of the subclavian vein.

An anatomic landmark is identified and described that simplifies the technique of central venous cannulation via the subclavian vein. The commonly used techniques are an approach to the subclavian at the junction of the medial and middle thirds of the clavicle or at the midclavicular line. A described anatomic landmark, the deltopectoral triangle, is easily identified in virtually all patients and requires no measuring or extensive knowledge of anatomy for localization. Penetration of the skin at this landmark facilitates the procedure and produces less patient discomfort. Using this technique, the authors have successfully cannulated the subclavian vein in 92.7% (51/55) of attempts with a 5.5% (3/55) complication rate. The only complications were arterial punctures, which were treated with pressure and were of no consequence to the patient.

Catheterization, Central Venous↗

Correction of axis misalignment in the analysis of knee rotations.

The Cardanic or Eulerian description is the most commonly used method for the description of in vivo knee rotation. It is based on the determination of external anatomical landmarks used for the decomposition of the position of the tibia relative to the femur by three rotations about three pre-defined axes. However, the in vivo localisation of external anatomical landmarks is known to be difficult and subjective. Even a small mislocalisation may lead to dramatic consequences: the Cardanic description may become irreproducible and angle values may be overestimated. This error is well documented in the literature and known as the "cross-talk effect". Therefore this study proposes an additional calibration step of the classic Cardanic description by a reorientation procedure of rotation axes. The procedure is based on biomechanical constraints of knee kinematics as they appear during a knee squat exercise using the finite helical axis (FHA) method and is independent of anatomical landmark. The method was validated with the help of a special set-up modelling a perfect knee. Furthermore, an inter-session reliability study was performed involving tests on two healthy subjects during knee squat exercises. We found that the reorientation procedure was more reproducible than the classic Cardanic description. We observed a maximum inter-session difference of 37.1 degrees for the adduction angle obtained with the classic Cardanic description. In contrast, the maximum angle difference obtained with the reorientation procedure was less than 10 degrees.

Adult↗

Double-Z rhombic technique for reconstruction of facial wounds.

The double-Z rhombic technique of repair of excisional defects is characterized by borrowing the required tissue from two nonadjacent opposite sides of the defect. Most other flaps borrow the required tissue from a single adjacent region or all adjacent directions. The "sharing" of tissue from two opposite regions minimizes tension in that direction, while not borrowing from the remaining regions prevents the distortion of anatomic landmarks located along that direction. The orientation of the final scar and direction of tissue tension can be controlled by rotating the rhombic defect about its central axis. This study was undertaken to assess the utility of the double-Z rhombic technique in terms of cosmesis and avoidance of displacement of mobile anatomic landmarks such as eyelids, eyebrows, nasal alae, and lips. Excisional defects resulting from removal of skin neoplasms in 30 patients in whom primary closure or reconstruction with direct tissue advancement was not feasible and displacement of facial landmarks was undesirable were reconstructed using the double-Z rhombic technique. No considerable asymmetry or facial anatomic landmark deformity was observed in any of the 30 patients. Our results are presented along with representative illustrations.

Basal Cell Carcinoma↗

Evaluation of Euler's angles with a least squares method for the study of lumbar spine motion.

To analyse intervertebral movements, methods with a high level of accuracy are required. Stereoradiographic methods have been used for a number of years to describe intervertebral movements, but their major problem is to identify the same anatomical landmarks, not only on the pair of radiographs used for three-dimensional reconstruction, but also on all the pairs used to analyse the displacements. To minimize the errors due to the incorrect identification of anatomical landmarks, a least squares method to resolve the parameters of Euler's angles was validated by means of measurements made on a spine obtained from a cadaver. The accuracy of this method varied between 0.69 degrees and 0.71 degrees in rotation and between 0.28 mm and 0.77 mm in translation. In addition, this method significantly corrected the position of the anatomical landmarks. Euler's angles, used with a least squares estimate, can provide accurate and precise results.

Aged↗

Panoramic roentgen anatomy of the maxillary sinus.

A dry maxillozygoma was radiographed with a Panex panoramic unit with lead foil and wires on the anatomic landmarks. The medical border of the maxillary sinus on the pantomogram is seen at the angle of the anterior and medial walls. The lateral border of the maxillary sinus consists of the maximum posterior convexity of the posterior, and medial walls are recognized as anatomic landmarks only when radiopaque materials are attached to individual walls. Most of the anterior and posterior walls of the maxillary sinus are superimposed upon the medial wall in the pantomogram. The anterior wall occupies the lateral third of the maxillary sinus. Anterior, posterior, and medial walls do not appear as anatomic landmarks on the pantomogram.

Humans↗

The relationship between intraoperatively assessed atrial and ventricular insertions of accessory pathways.

To gain insight into the complex problems regarding the extension of the atrial and ventricular insertions of anomalous pathways, the activation patterns obtained from intraoperative epicardial mapping in 23 patients with Wolff-Parkinson-White syndrome were carefully analyzed. The atrial and ventricular activation times along the atrioventricular groove were measured at 15 predefined anatomical landmarks. The width of the region of earliest atrial and ventricular activation times and the extent of atrial and ventricular overlap were assessed. The relationship between the atrial and ventricular insertions was studied by predicting the ventricular insertions from the observed atrial insertions and vice versa. The mean extension of an atrial and a ventricular insertion at surgery was 1.9 +/- 0.2 (SE) and 1.6 +/- 0.2 (SE) anatomical landmarks, respectively. The width of the region of early atrial and ventricular activation times measured 2.7 +/- 0.3 (SE) landmarks, thus indicating an overlap of the atrial and ventricular insertions. The lateral distance between the sites of earliest atrial and ventricular activation times was, on average, 1.7 +/- 0.3 (SE) landmarks. The predicted atrial insertion from a known ventricular insertion, and vice versa was found to cover 4 to 6 anatomical landmarks. These observations suggest that wide surgical dissections along the atrioventricular groove are warranted even if epicardial mapping discloses only a single accessory pathway.

Action Potentials↗

Advanced image-guided skull base surgery.

BACKGROUND: Tumors of the skull base frequently encase or extend into normal neural and vascular structures. Preoperative planning and intraoperative identification of anatomic landmarks is especially important in complex tumors since it helps avoid or minimize surgical morbidity. METHODS: By creating a surgical plan the image guidance software offers help in the establishment of a surgical approach. During surgery, the neuronavigation system displays the location of anatomic landmarks of the skull base regardless of any erosion or displacement. RESULTS: A series of 10 patients with complex tumors in various skull base locations is reported. Osseous structures are easily identified using the CT-based image guidance since these landmarks do not shift due to CSF loss. Image fusion of CT and MRI data gives additional information on the displacement of soft tissue structures. Image fusion in a substraction mode is helpful when a tumor has invaded bony structures or when the encasement of major vessels has to be visualized. CONCLUSION: The preoperative data preparation (planning of the approach, image fusion) plays a vital role in modern neuronavigation and contributes useful information during surgery for complex skull base tumors. Such advanced neuronavigation increases the efficacy and safety of intraoperative maneuvers. Eroded and distorted anatomic landmarks are not subject to a significant amount of intraoperative shift throughout the surgical procedure.

Adult↗

Operative therapy of atrioventricular node reentry and results of an anatomically guided procedure.

Operative therapy for atrioventricular (AV) node reentrant tachycardia consisting of dissection guided by anatomic landmarks is described. Of the 21 patients studied, 17 had the common type ("slow-fast") and 4 had the uncommon type ("fast-slow") of AV node reentry. Under normothermic cardio-pulmonary bypass, perinodal dissection was performed guided by anatomic landmarks: the atrial membranous septum, posterior superior process of the left ventricle, tendon of Todaro and os of the coronary sinus. There were no deaths or major complications. Seven to 10 days postoperatively, all patients had normal AV conduction except for one who continued to have AV node Wenckebach-type block. Postoperatively, the shortest cycle length capable of 1:1 conduction over the AV node changed from 323 +/- 66 to 421 +/- 90 ms (p less than 0.0001) anterogradely and from 330 +/- 86 to 449 +/- 164 ms (p = 0.004) retrogradely. Anterograde effective refractory period of the AV node prolonged from 264 +/- 49 to 358 +/- 107 ms (p = 0.012). Discontinuous AV conduction curves were no longer seen in 14 of 17 patients and 5 patients lost retrograde conduction. During follow-up (14.8 +/- 8.2 months), 19 patients have been free of arrhythmia without medication. Two patients required a second operation for recurrent tachycardia with success. No patient required a permanent pacemaker. These data show that operative therapy of AV node reentrant tachycardia can be guided by anatomic landmarks. Successful cure of tachycardia with perinodal dissection while preserving AV node conduction supports the view that the reentrant circuit is, at least in part, perinodal.

Adolescent↗

Digital video capture and synchronous consultation in open surgery.

OBJECTIVE: To achieve real-time or simultaneous surgical consultation and education to students in distant locations, we report the successful integration of robotics, video-teleconferencing, and intranet transmission using currently available hardware and Internet capabilities. SUMMARY BACKGROUND DATA: Accurate visualization of the surgical field with high-resolution video imaging cameras such as the closed-coupled device (CCD) of the laparoscope can serve to insure clear visual observation of surgery and share the surgical procedure with trainees and, or consultants in a distant location. Prior work has successfully applied optics and technical advances to achieve precise visualization in laparoscopy. METHODS: Twenty-five thyroidectomy explorations in 15 patients were monitored and transmitted bidirectionally with audio and video data in real-time. Remotely located surgical trainees (n = 4) and medical students (n = 3) confirmed 7 different anatomic landmarks during each surgical procedure. The study used the Socrates System (Computer Motion, Inc. [CMI], Goleta, CA), an interactive telementoring system inclusive of a telestration whiteboard, in conjunction with the AESOP robotic arm and Hermes voice command system (CMI). A 10-mm flat laparoscopic telescope was used to capture the optical surgical field. As voice, telestrator, or marker confirmed each anatomic landmark the image parameters of resolution, chroma (light position and intensity), and luminance were assessed with survey responses. RESULTS: Confirmation of greater than 90% was achieved for the majority of relevant anatomic landmarks, which were viewed by the remote audience. CONCLUSION: The data presented in this study support the feasibility for mentoring and consultation to a remote audience with visual transmission of the surgical field, which is otherwise very difficult to share. Additionally, validation of technical protocols as teaching tools for robotic instrumentation and computer imaging of surgical fields was documented.

Education, Medical↗

Repositioning accuracy of a commercially available double-vacuum whole body immobilization system for stereotactic body radiation therapy.

We evaluated the repositioning accuracy of a commercially available stereotactic whole body immobilization system (BodyFIX, Medical Intelligence, Schwabmuenchen, Germany) in 36 patients treated by hypofractionated stereotactic body radiation therapy. CT data were acquired for positional control of patient and tumor before each fraction of the treatment course. Those control CT datasets were compared with the original treatment planning CT simulation and analyzed with respect to positional misalignment of bony patient anatomy, and the respective position of the treated small lung or liver lesions. We assessed the stereotactic coordinates of distinct bony anatomical landmarks in the original CT and each control dataset. In addition, the target isocenter was recorded in the planning CT simulation dataset. An iterative optimization algorithm was implemented, utilizing a root mean square scoring function to determine the best-fit orientation of subsequent sets of anatomical landmark measurements relative to the original treatment planning CT data set. This allowed for the calculation of the x, y and z-components of translation of the patient's body and the target's center-of-mass for each control CT study, as well as rotation about the principal room axes in the respective CT data sets. In addition to absolute patient/target translation, the total magnitude vector of patient and target misalignment was calculated. A clinical assessment determined whether or not the assigned planning target volume safety margins would have provided the desired target coverage. To this end, each control CT study was co-registered with the original treatment planning study using immobilization system related fiducial markers, and the computed isodose calculation was superimposed. In 109 control setup CT scans available for comparison with their respective treatment planning CT simulation study (2-5 per patient, median 3), anatomical landmark analysis revealed a mean bony landmark translation of -0.4 +/- 3.9 (mean +/- SD), -0.1 +/- 1.6 and 0.3 +/- 3.6 mm in x, y and z-directions, respectively. Bony landmark setup deviations along one or more principal axis larger than 5 mm were observed in 32 control CT studies (29.4%). Body rotations about the x-, y- and z-axis were 0.9 +/- 0.7, 0.8 +/- 0.7 and 1.8 +/- 1.6 degrees, respectively. Assuming a rigid body relationship of target and bony anatomy, the mean computed absolute target translation was 2.9 +/- 3.3, 2.3 +/- 2.5 and 3.2 +/- 2.7 mm in x, y and z-directions, respectively. The median and mean magnitude vector of target isocenter displacement was computed to be 4.9 mm, and 5.7 +/- 3.7 mm. Clinical assessment of PTV/target volume coverage revealed 72 (66.1%), 23 (21.1%), and 14 (12.8%), of excellent (100% isodose coverage), good (>90% isodose coverage), and poor GTV/isodose alignment quality (less than 90% isodose coverage to some aspect of the GTV), respectively. Loss of target volume dose coverage was correlated with translations >5 mm along one or more axes (p<0.0001), rotations >3 degrees about the z-axis (p=0.0007) and body mass index >30 (p<0.0001). The analyzed BodyFIX whole body immobilization system performed favorably compared with other stereotactic body immobilization systems for which peer-reviewed repositioning data exist. While the measured variability in patient and target setup provided clinically acceptable setup accuracy in the vast majority of cases, larger setup deviations were occasional observed. Such deviations constitute a potential for partial target underdosing warranting, in our opinion, a pre-delivery positional assessment procedure (e.g., pre-treatment control CT scan).

Body Weights and Measures↗

A blinded assessment of radiographic criteria for atlanto-occipital dislocation.

STUDY DESIGN: Blinded comparison of 5 methods to diagnose atlanto-occipital dislocation (AOD) on plain radiographs and computerized tomography (CT) of the cervical spine. OBJECTIVE: To determine the best method to diagnose AOD. SUMMARY OF BACKGROUND DATA: Several methods are proposed for the diagnosis of AOD, including the Power's ratio, X-line method, basion-dens interval, condylar gap, and Harris method. No blinded comparison of the results of these methods has been compared to patient outcome, and there is no information available regarding the accuracy of these methods applied to CT scans. METHODS: Plain lateral radiographs and CTs of the cervical spine were reviewed in 104 patients, including 6 with AOD. Images underwent a blinded review by a board certified neurosurgeon (D.K.R.), orthopedist (P.A.A.), radiologist (J.C.), and emergency physician (D.B.B.). Each diagnostic method for AOD was applied for determination of sensitivity, specificity, and positive and negative predictive values. The ability to identify relevant anatomic landmarks was also tabulated. RESULTS: Average values for sensitivities, specificities, positive and negative predictive values for each method applied to plain radiographs are: 0.4625-1.0, 0.8933-0.9725, 0.2775-0.45, and 0.975-1.0, respectively. These values for each method applied to CT scans are: 0.7075-1.0, 0.8725-0.9775, 0.3175-1, and 0.98-1.0, respectively. Identification of relevant anatomic landmarks occurred 99.75% of the time when these methods were applied to CT scans compared to 39% to 84% of the time on plain radiographs. CONCLUSIONS: Sensitivity, specificity, positive and negative predictive values of these methods improve when applied to CT scans because of better visualization of anatomic landmarks. This result suggests CT scans of the cervical spine may be warranted in all trauma patients suspected of having cervical spine injury.

Atlanto-Occipital Joint↗

Geometrically accurate activation mapping of the atrioventricular node region during surgery.

A novel method has been developed to map activation in the triangle of Koch during surgery for cardiac arrhythmias and relate the map to anatomic landmarks. It uses a hand-held electrode mounted in a freely moving linkage that has three degrees of mechanical freedom. The movements of the linkage are sensed by a computer that continuously calculates the coordinates of the electrode. The surgeon clamps the device over the triangle of Koch after the right atrium has been opened and uses the electrode to trace the anatomic landmarks of the region that are displayed on the computer screen. The position of the electrode is displayed continuously relative to these landmarks and electrograms are recorded at known positions to generate a map. The activation sequences during sinus rhythm, atrioventricular node reentrant tachycardia, "common" and "uncommon" atrial flutter, long RP' tachycardia and retrograde conduction through paranodal pathways are presented. It is concluded that 1) the high spatial resolution reveals physiologically important areas in the maps that are 8 mm long and 3 mm wide and that these areas can be related to specific anatomic landmarks; 2) there are complex electrograms in the region that may reflect the activation of different myocardial layers; and 3) there are marked changes in conduction velocity and direction within the region.

Atrial Flutter↗

Three-dimensional integration of brain anatomy and function to facilitate intraoperative navigation around the sensorimotor strip.

We studied 12 patients with brain tumors in the vicinity of the sensorimotor region to provide a preoperative three-dimensional visualization of the functional anatomy of the rolandic cortex. We also evaluated the role of cortex-muscle coherence analysis and anatomical landmarks in identifying the sensorimotor cortex. The functional landmarks were based on neuromagnetic recordings with a whole-scalp magnetometer, coregistred with magnetic resonance images. Evoked fields to median and tibial nerve and lip stimuli were recorded to identify hand, foot and face representations in the somatosensory cortex. Oscillatory cortical activity, coherent with surface electromyogram during isometric muscle contraction, was analyzed to reveal the hand and foot representations in the precentral motor cortex. The central sulcus was identified also by available anatomical landmarks. The source locations, calculated from the neuromagnetic data, were displayed on 3-D surface reconstructions of the individual brains, including the veins. The preoperative data were verified during awake craniotomy by cortical stimulation in 7 patients and by cortical somatosensory evoked potentials in 5 patients. Sources of somatosensory evoked fields identified correctly the postcentral gyrus in all patients. Useful corroborative information was obtained from anatomical landmarks in 11 patients and from cortex-muscle correlograms in 8 patients. The preoperative visualization of the functional anatomy of the sensorimotor strip assisted in designing the operational strategy, facilitated orientation of the neurosurgeon during the operation, and speeded up the selection of sites for intraoperative stimulation or mapping, thereby helping to prevent damage of eloquent brain areas during surgery.

Adult↗

Location of the sensorimotor cortex: functional and conventional MR compared.

PURPOSE: To determine the value of functional MR imaging to supplement conventional MR imaging for locating the rolandic cortex. METHODS: Parasagittal MR images acquired in conjunction with functional MR images were reviewed. The central sulcus was identified on the MR images by conventional parcellation methods. In the functional MR images, the sensorimotor cortex (rolandic cortex) was identified by the activation secondary to finger and thumb movement or tactile stimulation of the palm. The location of the central sulcus and rolandic cortex was compared. RESULTS: In 18 of 23 studies, the central sulcus selected by anatomic criteria coincided exactly or approximately with the cortex activated by the motor or sensory tasks. In two cases of tumor, the rolandic cortex could be located by means of the activation, but the central sulcus was not identified because of severe distortion of anatomic landmarks. In two volunteers, the central sulcus identified by anatomic landmarks did not coincide with the activated cortex. CONCLUSION: This study demonstrates that functional imaging supplements anatomic imaging in locating the sensorimotor cortex. Functional MR imaging may be a useful adjunct to conventional MR imaging to determine noninvasively the proximity of eloquent brain to focal brain lesions.

Adult↗

Predictors of successful neuraxial block: a prospective study.

BACKGROUND AND OBJECTIVE: The epidural and subarachnoid spaces should be identified at the first attempt, since multiple punctures increase the risk of postdural puncture headache, epidural haematoma and neural trauma. The study aimed to describe the predictors of successful neuraxial blocks at the first attempt. METHODS: After institutional Review Board approval, 1481 patients undergoing spinal or epidural anaesthesia were prospectively enrolled. For each block we recorded: gender, age, height, weight, body habitus, anatomical landmarks (palpability of the spinous processes), spinal anatomy, patient positioning, premedication, needle type and gauge, approach, spinal level of the block, and the provider's level of experience. Retrieval of cerebrospinal fluid or loss of resistance to saline or air identified the subarachnoid and epidural spaces, respectively. The outcome variable was the first attempt success or failure (whether or not the needle was correctly located with one skin puncture and produced adequate surgical anaesthesia). Backward stepwise logistic regression tested its association with the other variables. RESULTS: The first-attempt rate of success was 61.51%. Independent predictors (Odds ratio, 95% confidence limits) were the quality of anatomical landmarks (1.92 (1.57; 2.35)), the provider's level of experience (1.24 (1.15; 1.33)) and the adequacy of patient positioning (3.84 (2.84; 5.19)). CONCLUSIONS: The successful location of the subarachnoid or the epidural space at the first attempt is influenced by the quality of patients' anatomical landmarks, the adequacy of patient positioning and the provider's level of experience.

Adolescent↗

Tibial torsion measurement by surface curvature.

BACKGROUND: Tibial torsion is the angle between the transverse axes of the proximal and distal tibial articular surfaces. It measures the degree of twisting of the tibia around its own longitudinal axis. The accurate measurement on the magnitude of tibial torsion is of great use in monitoring derangements. It is also useful as a baseline in the event of surgical intervention. Various methods have been developed but none of them have gained wide acceptance. Even the CT scan technique, which is considered the "gold standard", produces varying results when executed by different researchers. A quick, objective and non-invasive method is thus very much needed for the effective monitoring of tibial torsion in clinical environments. METHODS: Eighteen adult men's lower legs were scanned by a laser scanner to give the surface coordinates of the leg surfaces. By calculating curvature maps of legs from the 3D coordinates, stable anatomical landmarks such as the lateral and medial malleoli can be located. The angle indicating the degree of tibial torsion can then be derived from these landmarks. FINDINGS: The objective determination of the various anatomical landmarks results in a reproducible measure of tibial torsion. The results obtained in this study are generally in agreement with the measurements reported previously. INTERPRETATION: The reproducibility of the results allows for the objective observation, monitoring and comparison of tibial torsion over time and across subjects. It allows also for the development of a system of measurement that is fast, convenient, accurate and radiation-free.

Bone Diseases↗