PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Prospective blinded evaluation of Gd-DOTA- versus Gd-BOPTA-enhanced peripheral MR angiography, as compared with digital subtraction angiography.

PURPOSE: To compare the diagnostic accuracy of gadobenate dimeglumine (Gd-BOPTA)-enhanced versus gadoterate meglumine (Gd-DOTA)-enhanced magnetic resonance (MR) angiography in patients with peripheral arterial occlusive disease (PAOD). MATERIALS AND METHODS: Fifty-six patients underwent MR angiography enhanced with either Gd-DOTA (28 patients) or Gd-BOPTA (28 patients). All arterial segments from the renal arteries to the distal run-off vessels were evaluated for disease severity. The sensitivity, specificity, and accuracy of MR angiography enhanced with both agents separately were evaluated with a paired t test; digital subtraction angiography was the reference standard. Interobserver variability was assessed by using the Cohen test. RESULTS: Diagnostic MR angiograms were obtained in all 56 patients. Overall, sensitivity and specificity of Gd-DOTA-enhanced MR angiography were 96% and 93%, respectively, for observer 1 and 96% and 85%, respectively, for observer 2 (kappa = 0.82). Corresponding values for Gd-BOPTA-enhanced MR angiography were 94% and 93%, respectively, for observer 1 and 94% and 89%, respectively, for observer 2 (kappa = 0.78). No consistent differences between the two contrast materials in assessment of PAOD in the renal to popliteal arteries were observed. For assessment below the knee, specificity was slightly higher in the Gd-BOPTA group-91% and 84% for observers 1 and 2, respectively-than in the Gd-DOTA group-89% and 77%, respectively (P <.01). The number of nonassessable below-the-knee segments was significantly lower in the Gd-BOPTA group: nine of 299 segments versus 25 of 312 segments in the Gd-DOTA group (P <.01). CONCLUSION: At MR angiography of the distal run-off vessels, Gd-BOPTA yielded higher specificity and a significantly smaller number of nonassessable segments than Gd-DOTA. The diagnostic accuracy of the two gadolinium chelates at peripheral MR angiography was comparable in the renal to popliteal arteries.

Adult↗

Comparison of contrast enhanced MR-angiography-MRI and digital subtraction angiography in the evaluation of pancreas and/or kidney transplantation patients: initial experience.

To evaluate whether combined contrast enhanced MRA and MRI (ce-MRA-MRI) has the potential to replace intra-arterial DSA (i.a.DSA) in patients with impaired graft function or suspected of vascular complications after pancreas and/or kidney transplantation. 7 patients after combined pancreas-kidney and 22 patients after kidney transplantation underwent ce-MRA-MRI and i.a.DSA within a 3 days interval. Qualitative and quantitative comparison of the arterial and venous supply, the parenchyma and urinary collecting system was made. Both ce-MRA and i.a.DSA showed good results in the detection of arterial stenoses. However, ce-MRA falsely suggested stenoses if vascular clips were used; on the other hand, i.a.DSA was less informative if the graft arteries were very tortuous. Ce-MRA was superior in depicting the venous anatomy (p < 0.001) and the parenchymal enhancement of the pancreatic grafts. For the assessment of the contrast excretion, the pyelocalyceal system and the ureter of the renal graft ce-MRA-MRI was superior (p < 0.001), for small caliber arteries in the renal grafts i.a.DSA was of greater value (p < 0.001). The combination of ce-MRA and MRI is reliable for evaluating the vascular anatomy and has several advantages over i.a.DSA after pancreas and/or kidney transplantation. It can replace i.a.DSA in patients with impaired graft function or suspected of vascular complications after pancreas and/or kidney transplantation.

Adult↗

Retrograde visualization of the portal venous system using CO2 intraarterial digital subtraction angiography.

Carbon dioxide (CO2) intraarterial digital subtraction angiography (IADSA) provides retrograde visualization of the portal vein via a peripheral segmental hepatic artery. IADSA was performed in 12 patients with known hepatic diseases by injecting a peripheral hepatic artery with both CO2 gas and an iodinated contrast medium. The portal vein was constantly visualized only with CO2 IADSA in all patients. The injected CO2 may flow back into the portal vein through an anastomotic system known as the peribiliary or periportal plexus. This new method is safe and useful to image the portal venous system in patients with hepatic malignancy.

Angiography, Digital Subtraction↗

A 3D space-time motion evaluation for image registration in digital subtraction angiography.

In modern clinical practice, Digital Subtraction Angiography (DSA) is a powerful technique for the visualization of blood vessels in a sequence of X-ray images. A serious problem encountered in this technique is the presence of artifacts due to patient motion. The resulting artifacts frequently lead to misdiagnosis or rejection of a DSA image sequence. In this paper, a new technique for removing both global and local motion artifacts is presented. It is based on a 3D space-time motion evaluation for separating pixels changing values because of motion from those changing values because of contrast flow. This technique is proved to be very efficient to correct for patient motion artifacts and is computationally cheap. Experimental results with several clinical data sets show that this technique is very fast and results in higher quality images.

Algorithms↗

[Study of the renal venous outflow using digital subtraction angiography].

A venous phase of digit subtraction angiography (DSA) of the kidneys was evaluated in 87 urologic patients. The subtraction allows satisfactory visualization of the renal veins. Amplification of the image and its early emergence indirectly suggest pathological arteriovenous shunt confirmed by intraoperative rheography. Investigation of the renal veins and venous outflow from the kidneys with DSA bears sufficient information and is less traumatic versus standard retrograde venography.

Adult↗

Gadolinium-enhanced magnetic resonance angiography, colour duplex and digital subtraction angiography of the lower limb arteries from the aorta to the tibio-peroneal trunk in patients with intermittent claudication.

OBJECTIVES: To evaluate the sensitivity, specificity, positive and negative predictive value of contrast-enhanced (gadolinium) magnetic resonance imaging (CE-MRA) and colour duplex ultrasound (CDU) of lower limb arteries. DESIGN: Prospective, single centre study. MATERIAL AND METHODS: A consecutive series of 58 patients with intermittent claudication (IC) were examined with CE-MRA and CDU from the infrarenal aorta to the tibio-peroneal trunk with digital subtraction angiography (DSA) as reference. The arterial tree was divided into 15 segments, pooled into three regions; suprainguinal, thigh and knee. Sensitivity, specificity, positive and negative predictive values for significant obstructions were calculated. Cohen Kappa statistics was used to establish agreement between the three methods. RESULTS: The sensitivity (specificity in parentheses) for significant obstructions in the suprainguinal region were 96% (94%) for CE-MRA and 91% (96%) for CDU, in the thigh region 92% (95%) for CE-MRA and 76% (99%) for CDU, and in the knee region 93% (96%) for CE-MRA and 33% (98%) for CDU. CDU failed to visualize 10% of suprainguinal, 2% of thigh and 13% of knee-region arterial segments. CONCLUSIONS: Both CE-MRA and CDU are good alternatives to DSA in the suprainguinal- and thigh-region. In the knee region only CE-MRA can be relied upon as an alternative to DSA. Imaging by CDU is not suited to situations were evaluation of runoff vessels is important.

Aged↗

Left atrial myxoma: diagnosis by digital subtraction intravenous angiography.

Digital subtraction intravenous angiography (DSIVA) represents an important technical advance in angiographic diagnosis. Herein we present three patients with left atrial myxoma assessed by DSIVA. We review the role of DSIVA in evaluation of patients with suspected cardiac tumors and the importance of careful atrial-phase scrutiny in examinations obtained for other purposes (ie, pulmonary angiography and assessment of ventricular function).

Angiography↗

Peripheral arterial disease: therapeutic confidence of CT versus digital subtraction angiography and effects on additional imaging recommendations.

PURPOSE: To compare multi-detector row computed tomographic (CT) angiography and digital subtraction angiography (DSA) prior to revascularization in patients with symptomatic peripheral arterial disease for the purpose of assessing recommendations for additional imaging and physician confidence ratings for chosen therapy. MATERIALS AND METHODS: In a randomized controlled trial, 73 patients were assigned to CT angiography, and 72 were assigned to DSA. Physician confidence in the treatment decision was measured as a continuous outcome on a scale of 0-10 (uncertain to certain) and as a dichotomous outcome (further imaging recommended, yes or no). Mean confidence scores and additional imaging recommendations were compared between CT and DSA groups in an intention-to-diagnose-and-treat analysis. To detect trends in confidence, confidence scores were plotted over time, and multiple linear regression analysis was performed. To detect trends in additional imaging recommendations, logistic regression analysis was used. Data from eligible nonrandomized patients were analyzed separately. RESULTS: No statistically significant difference in baseline characteristics between randomized groups was found. CT had a lower confidence score than did DSA (7.2 vs 8.2, P < .001). Further imaging was recommended more often after CT (25 of 71 patients, 35%) than after DSA (nine of 66 patients, 14%; P = .003). Analysis of trends demonstrated increasing (but not statistically significant) confidence in CT and stable confidence in DSA. No significant difference was found in baseline characteristics between randomized and nonrandomized patients. Among nonrandomized patients, no significant difference in mean confidence score (8.2 vs 8.3, P = .26) was found between CT (n = 24) and DSA (n = 26). CONCLUSION: With CT angiography, physician confidence decreases with an associated increase in additional imaging prior to revascularization in patients with symptomatic peripheral arterial disease. Given that CT is less invasive than DSA, results suggest that CT may replace DSA in selected cases.

Adult↗

Diagnostic value of spiral-CT angiography in comparison with digital subtraction angiography before and after peripheral vascular intervention.

To evaluate spiral-computed tomography (CT) angiography in primary diagnosis and/or in noninvasive follow-up after vascular intervention, we compared spiral-CT angiography and conventional angiography before and after vascular intervention. Helical-CT examinations before and after percutaneous transluminal angioplasty (PTA) or stent implantation were performed in 10 patients (mean age 63 years) with symptomatic peripheral arteriosclerotic disease. Stenoses were located in the iliac, femoral, or popliteal artery. CT examinations were done with a spiral-CT in double detector technique (CT Twin, Elscint). The parameters were as follows: slice thickness: 5.5 mm, increment: 2.7 mm, pitch: 1.5, contrast medium: 150 mL, flow rate: 2.5 mL/second, delay: 30 seconds. For evaluation, transverse planes as well as maximum intensity projections and 3-D reconstructions were used. The possible scan length reached from the aortic bifurcation down to about 10 cm below the ankle trifurcation. Preinterventional digital subtraction angiography (DSA) was superior to CT angiography (CTA: 94%, maximum intensity projection [MIP] alone: 65%), although high-grade stenoses were detected by both methods. After intervention, a resolved stenosis and improved peripheral flow could be detected by helical-CT as well as by intraarterial angiography in every patient (100%). In the primary diagnosis of vascular changes, intraarterial DSA remains the method of choice. Nevertheless, spiral-CT angiography shows comparable results after percutaneous intervention and becomes a noninvasive alternative in the postinterventional follow-up.

Angiography↗

Intraarterial digital subtraction angiography: a comparative view.

Intraarterial digital subtraction angiography (IA DSA) was performed in 122 patients undergoing a variety of diagnostic and interventional angiographic procedures. Owing to the increased contrast resolution of DSA, diluted contrast material in concentrations of from 12-19% could be employed, thereby significantly reducing contrast material doses compared to doses used with conventional film-screen angiography or intravenous DSA. Patient discomfort was convincingly reduced due to the injection of dilute contrast material. Subtracted digital images could be viewed immediately on a cathode ray tube (CRT) resulting in faster procedures with less catheter time. Savings in film costs relative to conventional angiography were also achieved.

Angiography↗

Simultaneous structural and functional imaging of the transplant kidney using digital subtraction angiography.

We herein describe our preliminary experience with digital subtraction angiography in the noninvasive evaluation of renal transplant structure and function. A single digital subtraction angiography study was obtained in 38 patients with transplant kidneys and various levels of renal function. The main renal artery was demonstrated well in all studies. Stored digital information was used to generate appearance and clearance rates of contrast medium to produce a functional renal image. There was good correlation between the functional image pattern on digital subtraction angiography and the known degree of renal functional impairment. No adverse effects resulted from the small dose of intravenous contrast material used for angiography. This initial study suggests that digital subtraction angiography is a rapid, safe and noninvasive method for visualization of the transplant kidney, and can afford clinically relevant structural and functional information.

Adult↗

Multidirectional depiction of internal carotid arterial stenosis: three-dimensional time-of-flight MR angiography versus rotational and conventional digital subtraction angiography.

PURPOSE: To evaluate whether and to what extent greater number of projection images obtained at three-dimensional (3D) time-of-flight (TOF) magnetic resonance (MR) angiography versus conventional digital subtraction angiography (DSA) causes overestimation of internal carotid arterial (ICA) stenosis. MATERIALS AND METHODS: DSA (two or three projections), rotational angiography (16 or 32 projections), and 3D TOF MR angiography (12 projections) were performed in 47 stenotic ICAs of 38 symptomatic patients. Two observers independently measured maximum stenosis, and the mean differences among MR angiography, DSA, and rotational angiography were compared. RESULTS: Three rotational and five MR angiograms were nondiagnostic. Seven MR angiograms of ICA stenoses showed a signal void and were excluded from analysis. On the remaining 32 angiograms, mean differences in maximum stenosis for observers 1 and 2, respectively, were 7% (95% CI: 3%, 12%) and 8% (95% CI: 3%, 13%) at MR angiography versus DSA and 2% (95% CI: -2%, 7%) and -1% (95% CI: -5%, 3%) at MR angiography versus rotational angiography. ICA stenosis was graded significantly higher at MR angiography versus DSA, whereas, it was not overestimated at MR angiography versus rotational angiography. The difference in maximum stenosis at MR angiography versus DSA was significantly different from that of MR angiography versus rotational angiography. CONCLUSION: Apparent overestimation of ICA stenosis at 3D TOF MR angiography versus conventional DSA may be partly explained by the greater number of projection images available at 3D TOF MR angiography.

Aged↗

Digital subtraction angiography in the diagnosis of vascular rings.

Digital subtraction angiography was performed in six patients suspected of having a vascular ring. There were four males and two females. Two patients were less than 6 months of age, two were between 14 and 20 months, and two were ages 4 and 53 years. Four of the six patients had abnormal esophagrams. Five patients underwent peripheral intravenous digital subtraction angiography and a sixth patient underwent digital subtraction angiography via arterial catheterization. In two patients (ages 20 months and 4 years), the presence of a vascular ring was excluded by demonstrating an anatomically normal arch with an anomalous right subclavian artery. In three patients, a right aortic arch was present. Two of these patients had mirror image branching and a left ligamentum arteriosum. The third patient had an aberrant left subclavian artery and a left ligamentum. One patient had an anomalous right subclavian artery and a systemic collateral vessel arising from the aorta, supplying a confluence of vessels in the right lung hilum. In all patients, anatomic definition was accurate with the intravenous injection and there were no complications. In the patient who underwent intra-arterial injection, the dose of contrast was reduced 50% from the dose usually administered. Digital subtraction angiography appears to be a good adjunctive diagnostic method in patients in whom the presence of a vascular ring needs to be confirmed angiographically and obviates the need for arterial catheterization.

Aorta, Thoracic↗

Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction.

A dynamic MR angiography technique, MR digital subtraction angiography (MR DSA), is proposed using fast acquisition, contrast enhancement, and complex subtraction. When a bolus of contrast is injected into a patient, data acquisition begins, dynamically acquiring a thick slab using a fast gradient echo sequence for 10-100 s. Similar to x-ray DSA, a mask is selected from the images without contrast enhancement, and later images are subtracted from the mask to generate angiograms. Complex subtraction is used to overcome the partial volume effects related to the phase difference between the flowing and stationary magnetization in a voxel. Vessel signal is the enhancement of flow magnetization resulting from the contrast bolus. MR DSA was performed in 28 patients, including vessels in the lungs, brains, legs, abdomen, and pelvis. All targeted vessels were well depicted with MR DSA. Corresponding dynamic information (contrast arrival time ta and duration of the arterial phase tav) was measured: ta/tav = 3.4/4.7 s for the lung, 10.3/4.9 s for the brain, 12.8/19.3 for the aorta, 15.2/12.6 s for the leg. MR DSA can provide dynamic angiographic images using a very short acquisition time.

Abdomen↗

Renal digital subtraction angiography.

Renal digital imaging has progressed rapidly in reliability and potential since its clinical introduction in 1979. The advent of larger image intensifiers has made feasible subtraction imaging of the renal parenchyma and collecting systems as an adjunct to IV-DSA. The growing use of IA-DSA has expanded the utility of the technology to the examination of the intrarenal circulation, contrast-sensitive patients, and the performance of interventional procedures. There are experimental works suggesting that it may be feasible to derive accurate physiologic data reflecting renal blood flow and excretion from sequential alterations in intravascular contrast density. Thus, anatomic abnormalities and their significance might conceivably be determined, with minimal patient discomfort, from the same imaging procedure. The development of digital imaging technology and techniques continues to be of major interest to both academic and commercial investigators. Thus, further improvements in digital imaging and expansion of its capabilities are likely to occur.

Angiography↗

Comparison of asymmetry in cerebral blood flow between brain hemispheres using digital subtraction angiography.

BACKGROUND AND PURPOSE: Recently, endovascular techniques have gained significant therapeutic potential for both treatment and prevention of stroke. Cerebral angiography, which is an essential component of these procedures, has been used to provide morphological information regarding condition of blood vessels. In this study, we propose to determine the possibility of acquiring information regarding cerebral blood flow (CBF) in addition to morphologic information from data routinely available during angiography. METHODS: Digital subtraction angiography sequences were obtained for eight patients having occlusive disease in internal carotid artery (ICA) territories. Two regions-of-interest (ROIs) corresponding to the two brain hemispheres on AP view were delineated. For each image, the average pixel value within each ROI was calculated and used to generate time-density curves. Indices obtained from each curve were compared with each other and with the results obtained from the single photon emission computed tomography (SPECT) studies performed a pre- or postangiography procedure. RESULTS: Comparison between ICA stenosis and cerebral perfusion measurements revealed that cerebral perfusion deficit can be independent of arterial occlusive disease. The indices obtained from the time-density curves exhibit a correlating trend with the results from SPECT studies. However, lack of sufficient sample data prevented any meaningful statistical analysis to be conducted. CONCLUSIONS: We have developed a technique for utilizing the angiographic data for the important task of routinely and easily measuring CBF. Availability of CBF measurements during cerebral angiography may favorably impact upon the appropriate use of endovascular procedures and potentially contribute to the reduction of morbidity and mortality associated with stroke.

Aged↗