A novel diagnostic tool for detecting oesophageal pathology: the PillCam oesophageal video capsule.

BACKGROUND: Gastro-oesophageal reflux disease is a common entity. Erosive oesophagitis, ulcers and Barrett's oesophagus, which is found in up to 10% of gastro-oesophageal reflux disease patients, characterize severe gastro-oesophageal reflux disease. Patients with Barrett's oesophagus have 0.5% per patient-year risk of developing oesophageal adenocarcinoma. Currently, it appears that a minority of those at risk for Barrett's oesophagus undergo screening in part because of the costs associated with endoscopy as well as risks of sedation. A new ingestible PillCam oesophageal capsule developed may offer an alternative office-based approach to visualize the oesophagus without sedation. AIM: To compare the oesophageal capsule to conventional upper endoscopy for detection of oesophageal pathologies. METHODS: A newly developed capsule, which acquires video images from both ends of the device at a 4 frame/s rate, was ingested by 17 fasting patients with suspected oesophageal disorders. An ingestion procedure aimed to lengthen capsule transit time in the oesophagus was utilized. Subsequently, a standard upper endoscopy was carried out. The investigator interpreting the capsule findings was blinded to the endoscopy results and vice versa. Patients with dysphagia, known Zenker's diverticulum, intestinal obstruction, cardiac pacemaker or pregnancy were excluded. RESULTS: Twelve of the 17 patients examined had oesophageal findings using the endoscope as the gold standard. Capsule endoscopy identified oesophageal pathology in all 12 of these patients and an additional pathology in one patient that was missed during endoscopy. For the purpose of this study, this finding was regarded as a false-positive. The mean oesophageal passage time was 189 +/- 280 s. The positive predictive value of the oesophageal capsule for any oesophageal pathology was 92% and the negative predictive value was 100%. Oesophageal capsule sensitivity was 100% and specificity 80%. There were neither swallowing difficulties nor complications subsequent to ingestion in any subjects. Seventy-three percentage of patients preferred the oesophageal capsule procedure on conventional endoscopy. Only one patient preferred oesophagogastroduodenoscopy. CONCLUSIONS: This pilot study has shown that oesophageal capsule endoscopy is an accurate, convenient, safe and well-tolerated method to screen patients for significant oesophageal disorders. No sedation is required, which may allow simple, office-based screening and assessment. Further, large-scale studies are necessary to more fully assess this novel diagnostic tool.

Adult↗

Capsule endoscopy: role of bowel preparation in successful visualization.

BACKGROUND: Lesions of the small bowel that cannot be detected by other techniques can be indentified by capsule endoscopy. Good preparation before any endoscopic procedure is the most important factor for patient safety, quality of care and cost effectiveness. This should also apply to capsule endoscopy. The aim of this study was to evaluate the quality and efficacy of preparation with oral sodium phosphate for capsule endoscopy. METHODS: A retrospective cohort study design was used. The study sample consisted of 32 consecutive patients scheduled for capsule endoscopy in two periods; the first 10 patients were prepared with overnight fasting only, and the next 22 with oral sodium phosphate. An experienced endoscopist and gastroenterology nurse, who were blinded to the method used, graded the quality of preparation. RESULTS: Small-bowel cleansing was significantly better in patients given sodium phosphate. Five patients (50%) received a poor preparation rating in the first period compared with only 1 (4.5%) of the 22 patients given oral sodium phosphate (P = 0.01). Intraluminal fluid was noted in 9 patients (90%) in the first group after a mean of 53 +/- 60 min, and in 17 patients (77%) in the second group after a mean of 158 +/- 71 min (P < 0.001). The proportion of non-ideal preparation was significantly higher in group 1 than in group 2, significant visualization disturbances being more prevalent in the first period. CONCLUSIONS: Bowel preparation with sodium phosphate before capsule endoscopy offers better visualization than overnight fasting alone and induces fewer disturbances by intraluminal turbid fluid.

Administration, Oral↗

Wireless capsule endoscopy and double-balloon enteroscopy for the diagnosis of obscure gastrointestinal bleeding.

Standard endoscopic examination (upper gastrointestinal endoscopy and colonoscopy) fails to detect the cause of gastrointestinal hemorrhage in approximately 5% of patients. Before the availability of wireless capsule endoscopy and double-balloon enteroscopy, imaging modalities for the small intestine distal to the ligament of Treitz included barium contrast examination and/or enteroclysis, push, passive, or intraoperative enteroscopy, technetium 99m labeled sulfur colloid scanning, angiography, and computed tomography, although the diagnostic yield of all of these imaging modalities was low. In 2001, wireless capsule endoscopy became available for the evaluation of patients with probable small intestinal hemorrhage. Advantages of wireless capsule endoscopy include that the procedure is noninvasive, requires no sedation, and does not expose the patient to ionizing radiation. In patients with obscure gastrointestinal hemorrhage, studies have demonstrated an additional 25 to 50% diagnostic yield using wireless capsule endoscopy when compared to other diagnostic modalities. The major limitations of capsule endoscopy were its inability to obtain a biopsy, precisely localize a lesion, or perform therapeutic endoscopy. In 2001, the double-balloon enteroscope was introduced. This new endoscopic technique provides the gastroenterologist with an opportunity for further evaluation and treatment of abnormalities detected on wireless capsule endoscopy or other small intestinal imaging studies.

Capsules↗

Crohn disease of the small bowel: preliminary comparison among CT enterography, capsule endoscopy, small-bowel follow-through, and ileoscopy.

PURPOSE: To prospectively compare four diagnostic small-bowel imaging techniques for depiction of abnormal findings in the same patients known to have or suspected of having Crohn disease. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Patients known to have or suspected of having nonobstructive Crohn disease were recruited. Each patient underwent capsule endoscopy, computed tomographic (CT) enterography, colonoscopy with ileoscopy, and small-bowel follow-through (SBFT). Findings consistent with Crohn disease were tabulated for each imaging examination (diagnostic yield). The proportions of patients with positive findings at each examination were compared, and any significant differences between the tests were calculated by using the exact McNemar test. RESULTS: Seventeen patients (nine women, eight men; mean age, 49 years; range, 18-78 years) completed the study out of 20 patients enrolled. Crohn disease was depicted by capsule endoscopy in 12 patients (71%), ileoscopy in 11 (65%), CT enterography in nine (53%), and SBFT in four (24%). Ileoscopy was incomplete in four patients, and capsule endoscopy was incomplete in two patients. Capsule endoscopy had the highest diagnostic yield for Crohn disease, and SBFT had the lowest, but these differences were not statistically significant (P = .02). SBFT failed to depict a stricture in one patient, which resulted in surgical removal of the capsule. CT enterography and SBFT depicted extraintestinal findings (eg, mesenteric adenopathy in two patients, perianal and enterocolic fistulas in one patient) not detected endoscopically. CONCLUSION: This preliminary study demonstrates capsule endoscopy and CT enterography may depict nonobstructive Crohn disease when techniques such as ileoscopy and SBFT have negative or inconclusive findings.

Adolescent↗

In vivo robotic capsules: determination of the number of turns of its power receiving coil.

This paper introduces a strategy how to determine the number of turns of the receiving coil for in vivo robotic capsules to maximize the regulated load power. For the expected functionality additional to the endoscopic function, it is necessary to employ wireless power transmission and increase the receiving power to a maximum. The functional relation between the number of turns and the power is derived and verified by implementing a ferrite-loaded receiver coil.

Capsule Endoscopes↗

[Endoscopically-assisted lipoma removal].

Since 1994 we have been removing large capsulated lipomas which are localised in an esthetically exposed and/or functional region using endoscopically assisted technique. This technique is minimally invasive and allows optimal visualisation of the tumour during the removal. Only a small incision is required to prepare the tumour in toto with capsula. With the endoscopic control of the wound we can avoid greater haematomas, which is very important for wound healing.

Endoscopes↗

Push-and-pull enteroscopy using the double-balloon technique (double-balloon enteroscopy) for the diagnosis of Meckel's diverticulum in adult patients with GI bleeding of obscure origin.

BACKGROUND: Meckel's diverticulum (MD) occurs in 2-3% of the population. Although the clinical, histopathologic, and radiologic features of the complications of MD are well known, the diagnosis may be difficult before surgery. CASE REPORT: Three patients (age 22-34 yr, two women) presenting with gastrointestinal (GI) bleeding of obscure origin underwent multiple endoscopic and radiologic tests including capsule endoscopy and Tc-99m pertechnetate scintigraphy before push-and-pull enteroscopy using a double-balloon technique (double-balloon enteroscopy). Double-balloon enteroscopy was performed in all three patients using oral and anal approaches to evaluate the entire intestine. In one case, MD was detected using the oral route; the diagnosis was confirmed using the anal approach. In two patients, the lumen of MD was disclosed using the anal route. No procedure-related complications occurred. Push-and-pull enteroscopy was the only nonsurgical procedure that provided a precise diagnosis. All patients underwent surgical resection of the diverticulum. In one case, ectopic gastric tissue was found histologically. No further bleeding occurred during follow-up (6-9 months). CONCLUSIONS: Keeping the low sensitivity of Tc-99m scintigraphy in the adult population in mind, double-balloon enteroscopy might be the modality of choice in young adult patients with acute recurrent GI bleeding of obscure origin and a suspected diagnosis of MD.

Adult↗

A new approach to blue rubber bleb nevus syndrome: the role of capsule endoscopy and intra-operative enteroscopy.

Blue rubber bleb nevus syndrome (BRBNS) is a rare vascular malformation disorder with cutaneous and visceral lesions frequently associated with serious, even fatal bleeding and anemia. The syndrome is considered to be autosomaly predominantly inherited. Intra-operative enteroscopy (IOE) is the best method of identification of all lesions (particularly the small ones, less than 3 mm) and treatment by endoscopic electro-coagulation or surgical excision. Capsule wireless endoscopy is optimal for screening before the IOE and for monitoring the effect of therapy (in patients with BRBNS). We report two cases of BRBNS. Anemia, gastrointestinal bleeding, gastrointestinal malformations and multifocal venous malformations of the skin were present in both of our cases. Gastrointestinal lesions were identified by gastroscopy, colonoscopy and capsule endoscopy. The multiple venous malformations were treated partly by endoscopic electro-coagulation (lesions up to 4 mm in diameter) and by wedge resection. Both of our patients were 12-year-old girls at the time of operation. In the first patient 31 venous malformations of the small bowel were coagulated, two were resected by the surgeon. In the second patient 20 lesions were coagulated endoscopically and another 31 nevi were resected during an 8 h procedure. The first girl is doing fine 4 years after the procedure, the second was allowed home 2 weeks after the procedure in excellent condition. IOE is a unique method of small bowel investigation and concurrently provides a solution for pathological findings. Capsule endoscopy is a feasible non-invasive screening procedure. We believe that a radical eliminatory approach by means of combined surgery and IOE is indicated for the BRBNS to prevent ongoing gastrointestinal bleeding.

Arteriovenous Malformations↗

Intracapsular partial tonsillectomy for tonsillar hypertrophy in children.

OBJECTIVE: To review our experience with intracapsular tonsillectomy using powered instrumentation in the management of tonsillar hypertrophy causing obstructive sleep-disordered breathing in children. STUDY DESIGN: Retrospective case series. METHODS: Intracapsular tonsillectomy, a form of partial tonsillectomy performed with an endoscopic microdebrider, preserves the tonsillar capsule as a barrier to exposure of the pharyngeal muscles. Results in 150 children who underwent this procedure were compared with those in 162 children who had standard tonsillectomy. RESULTS: Children who underwent intracapsular tonsillectomy had significantly less pain throughout the recovery period than those who had standard tonsillectomy. There was no significant difference between the two groups in intraoperative blood loss, and no episodes of immediate postoperative bleeding occurred in either group. Six patients who had the standard operation and one patient who had the intracapsular procedure had delayed hemorrhage requiring hospital readmission. Five children in the standard group and one in the intracapsular group were readmitted because of dehydration. Thus, in all, 11 readmissions were necessary among children who underwent standard tonsillectomy, whereas 2 were required among those who had intracapsular tonsillectomy. CONCLUSION: Intracapsular tonsillectomy is as effective as standard tonsillectomy in relieving obstructive sleep-disordered breathing but produces less postoperative pain and fewer episodes of delayed hemorrhage and dehydration.

Case-Control Studies↗

Minute flat depressed neoplastic lesions of the colon detected by contrast chromoscopy using an indigo carmine capsule.

Thirty-seven diminutive flat depressed neoplastic lesions of the colon, smaller than 5 mm, were detected by contrast chromoscopy using an indigo carmine capsule and subsequently removed by endoscopic mucosal resection. We investigated the endoscopic, macroscopic, and histologic characteristics of these lesions and also evaluated the usefulness of chromoscopy and the magnifying endoscope for detecting this type of lesion. The lesions were classified into two types according to the measured height of the histologic sections: 28 lesions were truly flat depressed and the remaining 9 lesions were flat elevated. Of the 37 lesions, 18 were adenomas with mild atypia, 14 with moderate atypia, and 5 with severe atypia. The flat depressed lesions included 12 with mild atypia, 11 with moderate atypia, and 5 with severe atypia. No invasive carcinoma was present in either type, and no adenoma with severe atypia was identified in any of the flat elevated lesions. The overall rate of severe atypia was 13.5%; the rate of severe atypia for the flat depressed type was 17.9%, which is approximately 14-fold greater than that of ordinary diminutive polypoid adenomas (1.3%). The detection of these lesions was facilitated by the use of indigo carmine dye, which clearly demonstrated the mucosal irregularities. The frequency of detection of these lesions was increased four to five times with a magnifying endoscope, as occurred in nearly 10% of all of the patients examined. These data suggest that the finding of endoscopically minute flat depressed neoplastic lesions is not at all uncommon when examination is meticulously performed.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenoma↗

[Effective treatment of duodenal ulcer with cimetidine (author's transl)].

Twelve male duodenal ulcer in-patients received in a double-blind trial either the histamine H2-receptor antagonist cimetidine (4 X 200 mg/d p.o.) or placebo capsules. Ulcer sizes were assessed endoscopically before therapy followed by repeat endoscopy at weekly intervals. Duodenal ulcer healing was significantly more rapid in cimetidine-treated patients than in those receiving the placebo (chi2 test; P less than 0.0005). Plotting of log ulcer sizes (mm2) against time (days) resulted in regression lines the slopes of which indicated the respective half-time of ulcer healing: about 6 days on cimetidine therapy and about 20 days on placebo treatment. Gastric secretion of acid, protein, pepsin, and N-acetylneuraminic acid-containing glycoproteins was not altered by a 4-week course of daily cimetidine or placebo, nor pancreatic secretion of bicarbonate and enzymes. No statistically significant changes in laboratory findings (haemoglobin, white blood-cells, neutrophils, platelets, alkaline phosphatase, blood-urea, serum-creatinine, GOT, GPT) were associated with treatment.

Adolescent↗

[Intestinal biopsy: fiberscopy or Watson's capsule?].

We compared the results of 100 fiberendoscopic small bowel biopsies (F) with those of 100 Watson capsule biopsies (W). Three to 6 specimens were obtained during endoscopy. The F biopsy fragments were deeper than the W biopsies (P less than 0.001). The F biopsies were more often located in the duodenum than the W biopsies. The failure rate of the F biopsies (3%) was lower than for the W biopsies (12%): P less than 0.02. Multiple biopsies increased the diagnostic value of fiberendoscopy, which was 85% in our experience versus 77% for Watson capsule. The duration of the endoscopic procedure, available in 15 children, was 6.5 min for 4 to 6 samples, i.e. 1.5 min by specimen. Small bowel fiberendoscopy appears to be a safe and accurate method for performing small bowel biopsies in infants and children.

Adolescent↗

[Gastroesophageal reflux. Study with Helderberg's telemetric capsule].

Thirty patients in which there was a clinical suspicion of esophagitis reflux were studied. After radiological and endoscopic study, the gastroesophageal reflux was determined by means the Heidelberg telemetric capsule, for this purpose HCl 0.1N was used and changes in the gastroesophageal pH were registered in the Trendelenburg position. The results were correlated with the radiological and endoscopic findings.

Capsules↗

Wireless capsule endoscopy in a community gastroenterology practice.

GOALS: This study was performed to evaluate the use of wireless capsule endoscopy in a community gastroenterology practice. BACKGROUND: Experience with wireless capsule endoscopy at referral centers has been reported, but little has been reported about community gastroenterologists' experience. STUDY: A retrospective review of charts and wireless capsule endoscopies performed at a community hospital was performed. RESULTS: A total of 99 wireless capsule endoscopies were reviewed and complete data were available in 72 cases. Indications included suspected obscure GI bleeding in 97% of cases; 55% of patients were taking anti-platelet or anti-coagulant medications; 71% of examinations were complete. Pathologic findings included angioectasias (36%), gastritis/erosions (21%), bleeding (18%), small bowel ulcers (16%), duodenitis (7%), and small bowel erosions (6%). Strictures, Crohn's disease, and tumors were each seen in 3%. There were no abnormal findings in 37%. One complication, nonnatural excretion of the capsule, caused a transient bowel obstruction but passed without endoscopic intervention or surgery. CONCLUSIONS: In a community-based gastroenterology setting, wireless capsule endoscopy is a safe tool that shows abnormalities in a significant proportion of exams.

Aged↗

Retrieval of ureteral calculus using a new method of endoscopic assistance in a cat.

A 9-year-old female spayed domestic short-haired cat presented with ureteral obstruction due to a ureteral calculus 4 cm distal to the renal pelvis. Preoperative creatinine was 844 mmol/L. A novel approach to this condition was utilised whereby a flexible endoscope was passed through a hole made in the renal capsule into the renal pelvis and ureter. The calculus was visualised, and the endoscope was removed. A 1.4 mm flexible grasping forceps was introduced into the proximal ureter through the same hole in the renal capsule and the calculus was removed. The creatinine dropped to 282 micromol/L within 2 weeks of surgery. The cat died of apparently unrelated causes several months after surgery.

Animals↗

Electronic endoscopy in perspective.

Electronic endoscopy, developed in 1983, enables the endoscopic image to be transmitted through electric signals that can be easily processed by computer. An electronic endoscope is composed of three vital parts, i.e., a charge-coupled device (CCD) that converts the image to electric signals, a video processor that converts analog electric signals to the digital and processes them to become video signals, and a television monitor. The introduction of electronic endoscopy has enabled computer management of endoscopic images, on one hand, and provided an opportunity for image processing and analysis, on the other. A digital image management system will further develop into a database of endoscopic images. Combined with the technologies of remote control and remote sensing, the introduction of CCD to endoscopy has made it possible to transform the endoscope, so that it could become a capsule. Future advances in the research of image processing and analysis will lead to the development of a system of automated endoscopic diagnosis.

Electronics, Medical↗

Frictional resistance characteristics of a capsule inside the intestine for microendoscope design.

The design of the capsule body for a self-propelled endoscope is important from the frictional resistance point of view. The motivation of this work was to gain a better understanding of the effect of capsule shape on the frictional resistance of the capsule inside a small intestine. Special experimental set-ups were built to investigate the frictional resistance of the capsule and the viscoelastic deformation characteristics of the small intestine specimen of a pig. Tests were performed with capsules of various shapes and dimensions. Experimental data showed that a smooth cylindrical capsule geometry resulted in the least frictional resistance due to the shape and relatively small surface area. Also, it was found that the variation of frictional resistance of the capsule was closely related to the local change in the viscoelastic property of the intestine due to the heterogeneity of the internal structure of the intestine.

Animals↗