PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Immunomagnetic Separation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Staphylococcus aureus exopolysaccharide in vivo demonstrated by immunomagnetic separation and electron microscopy.

Staphylococcus aureus strains were separated from mastitis milk samples without cultivation by using monodisperse magnetic polymer particles coated with polyclonal antiserum against an encapsulated S. aureus strain. Exopolysaccharide was verified by transmission electron microscopy and the serum soft-agar culture technique. Capsular polysaccharide was found on virtually all clinical isolates. Surface protein A and S. aureus-specific cell wall components were masked when the strains were cultured on an exopolysaccharide-promoting medium. Masking of surface determinants was dependent on their concentration on the bacterial surface as well as on exopolysaccharide abundance. The polysaccharide layer on in vivo bacteria was reduced markedly after just one transfer from milk to blood agar plates but was reexpressed after culturing was done on a capsule-generating medium.

Animals↗

The in vitro effects of stem cell factor and PIXY321 on myeloid progenitor formation (CFU-GM) from immunomagnetic separated CD34+ cord blood.

Two novel cytokines, stem cell factor (SCF) and PIXY321 (a fusion protein, granulocyte macrophage colony-stimulating factor+IL-3), have recently been demonstrated to enhance in vitro adult myelopoiesis. In this study, we compared the success of separating very early hematopoietic progenitor cells (CD34+) from both cord blood (CB) and adult bone marrow (ABM) and their differential response to SCF, PIXY321, and other later-acting colony-stimulating factors (CSF). Briefly, CD34+ cells were isolated from CB and ABM with an anti-CD34 MAb, HPCA-1, and incubated with various combinations of SCF, PIXY321, and other CSF. The percentage of CD34+ cells was decreased in CB compared to ABM before separation (0.54 versus 1.71%) (p = 0.05). Isolated CD34+ cells from CB and ABM were similar in lineage with respect to CD38, HLA-DR, CD33, and CD5, but decreased in CB with respect to B-lineage expression (CD19, CD10, and CD22) (p = 0.05). SCF increased colony forming unit-granulocyte-macrophage (CFU-GM) formation from CB CD34+ cells compared to unconditioned media and had a significant additive increase with IL-3 (p = 0.006) and granulocyte colony-stimulating factor (p = 0.03). SCF also had an additive increase in CB CFU-GM formation with PIXY321 (p = 0.007). PIXY321 had a similar increase in CFU-GM formation from both CB and ABM CD34+ cells compared to the combination granulocyte macrophage colony-stimulating factor + IL-3. When SCF was added to IL-3, PIXY321, or PIXY321 + IL-6, there was an increase in CFU-GM from CB versus ABM CD34+ cells.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Rapid direct determination using combined separation by prepared immunomagnetic and flow cytometry of Flavobacterium psychrophilum.

Flavobacterium psychrophilum, the causative agent of bacterial cold-water disease (BCWD), was originally isolated from coho salmon Oncorhychus kisutch in the USA. Bacterial cold-water disease has since been spreading throughout Japan and has caused serious damage to populations of ayu Plecoglossus altivel in many farms and rivers. The rapid method of detecting for F. psuchrophilum is requested, however, traditional methods are laborious because of complicated assay procedures. In this study, a rapid method of detecting F. psychrophilum was developed using a modified method of flow cytometry (FCM) analysis and immunomagnetic separation (IMS). Magnetic iron, in small particles, was prepared by the reaction of a mixture of ferric and ferrous ions under alkaline conditions. The particles were coated with antiserum against F. psychrophilum by dextran. Polyclonal antibodies (anti-F. psychrophilum) conjugated with fluorescein isothiocyanate (FITC) were reacted with F. psychrophilum, and then prepared immunomagnetic were applied using IMS, followed by FCM determination. A good correlation was observed between the cell numbers determined by the FCM method and the traditional method in the range of 10(2)-10(8) cells ml(-1). The FCM analysis could count cells within 1min, and the total analysis time, including sample preparation, was less than 2 h.

Cell Separation↗

The efficiency of tumor cell purging using immunomagnetic CD34+ cell separation systems.

Immunomagnetic separation with anti-CD34 monoclonal antibodies and paramagnetic microbeads has been used to enrich hematopoietic stem cells from human bone marrow (BM) or mobilized peripheral blood mononuclear cells (PBMNC). The introduction of this technique also constitutes a new principle of tumor cell purging. The efficiency in terms of purging tumor cells from PBMNC was evaluated in seven different experiments. Mobilized (chemotherapy and G-CSF) PBMNC were collected from patients with solid tumors (n = 6) and multiple myeloma (n = 1) by leukapheresis using an automated MNC separation system and contaminated with 1% (n = 5) or 10% (n = 2) tumor cells from different epithelial cell lines being CD34-negative. The cell mixture was sensitized with anti-CD34 (9C5) antibodies and sheep anti-mouse IgG1 paramagnetic microspheres and enriched for CD34+ cells using an Isolex 50 magnetic separator. Purify of CD34+ cells was studied by flow cytometry (FACScan) and tumor cell depletion was evaluated by comparative human tumor cloning assays (HTCA) containing methylcellulose and agar. We achieved a median purity of CD34+ cells of 85.9% (range 69.8-92.9%) and a median yield of 48.1% (range 21.0-85.2%). From these data in each case the estimated log depletion of tumor cells was calculated and compared with the experimentally achieved (HTCA) log depletion (log delta depletion = log experimental depletion--log calculated depletion). In our experiments we achieved a median depletion of 2.75 log (range 1.55-3.69 log). When corrected for CD34+ cell yield of each experiment we observed a median 'yield corrected depletion' of 2.38 log (range 1.48-3.15 log). The following delta depletion values were obtained: +0.32 log (HTB 129, breast), +0.21 log (HTB 26, breast), +0.04 log (HTB 26) for experiments with higher experimental depletion, and -0.23 log (HTB 26), -0.9 log (HTB 26, PBMNC from patient with multiple myeloma), -0.82 log (HTB 131, breast) and -1.66 log (HTB 131) for lower depletion efficacy than calculated. These data suggest that depletion may depend on specific cell surface characteristics of tumor cells. Moreover, plasma factors (eg paraprotein) may also have some impact. In summary, the Isolex 50 provides a high purity of CD34+ cells and depletion of tumor cells was efficient. However, calculated and experimental purging efficiencies are not necessarily identical.

Antigens, CD34↗

Detection and enrichment of disseminated renal carcinoma cells from peripheral blood by immunomagnetic cell separation.

We have established an immunomagnetic separation procedure for the detection of circulating tumor cells in the peripheral blood based on the magnetic cell sorting (MACS) technique. In previous in vitro experiments, renal-cell carcinoma (RCC) cells were mixed with peripheral blood. In dilutions of 1:200 to 1:107 tumor cells per mononuclear blood cells, an average recovery rate of 84% of tumor cells was determined. In our study, 104 peripheral blood samples from 59 renal carcinoma patients were analyzed. MACS resulted in significant depletion of leukocytes, permitting a search for tumor cells on just 1 slide. Analyzing 8 ml of peripheral blood per patient, 19/59 RCC patients carried disseminated tumor cells (32%) in the range of 1 to 38 cells (median 8). Interestingly, for the cytokeratin-positive (CK+) patient group, we found a correlation between tumor cell number and grading (G2 vs. G3) and an increased number of CK+ patients with advanced tumor stage. MACS appears to be an efficient technique to detect disseminated tumor cells in peripheral blood.

Adult↗

Detection of Helicobacter pylori in fecal samples of gnotobiotic mice infected with H. pylori by an immunomagnetic-bead separation technique.

By an immunomagnetic-bead (IMB) separation technique, isolation of Helicobacter pylori from gastrointestinal and fecal samples of gnotobiotic mice infected with the microorganism was tried. The isolation rate of H. pylori from stomach samples after IMB separation was not higher than that of direct culture of the samples. After IMB separation of feces, H. pylori was detectable by PCR, although H. pylori was not culturable.

Animals↗

Automated high-throughput immunomagnetic separation-PCR for detection of Mycobacterium avium subsp. paratuberculosis in bovine milk.

Two monoclonal antibody-mediated immunomagnetic separation PCR kits (AnDiaTec ParaTub-S IMS-PCR-ELISA and ParaTub-SL IMS-real time PCR) were developed and evaluated for the automated high-throughput detection of Mycobacterium avium subsp. paratuberculosis (M. paratuberculosis) in bulk milk of naturally infected dairy herds and made commercially available. M. paratuberculosis are first isolated from milk by high-throughput immunomagnetic bead separation using a completely automated magnetic particle pipetting robot within 45 min and released subsequently for analysis directly into PCR amplification mixtures for real time PCR or for PCR-ELISA. The threshold detection level and specificity of the tests were evaluated first with different M. paratuberculosis pure cultures and artificially contaminated (spiked) bulk milk samples. Both experiments proved a good detection limit, specificity and reliability of the tests that consistently detected 20 or less M. paratuberculosis organisms from cattle, deer and mufflon in 1 ml milk. Experiments with more than 200 bulk milk samples that were tested in parallel with the PCR methods and with the cultural method in a second evaluation study demonstrated that both PCR tests are superior to culture and sufficiently sensitive to detect single shedders in pooled milk samples. The experiments proved that the newly developed tests are sensitive, specific and fast, and thus for the first time allow the standardized large-scale routine M. paratuberculosis screening of bulk milk samples at acceptable costs.

Animals↗

Isolation and culture of human bone marrow endothelial cells.

Bone marrow endothelial cells are likely to play an important role in the homing of hematopoietic progenitor cells. In view of analyzing the interactions between endothelial cells and hematopoietic progenitor cells, we studied several methods of isolating endothelial cells from human bone marrow, including fluorescence activated cell sorting (FACS) and separation by immunomagnetic beads. FACS sorting gave the best results as contamination with other cells did not occur. After density-gradient centrifugation of bone marrow aspirates, the mononuclear cell (MNC) fraction was depleted for T cells, B cells, and myeloid cells by immunomagnetic separation. Further enrichment of endothelial cells was achieved by FACS sorting using BNH9 or S-Endo1 monoclonal antibodies (MAbs). These MAbs, in contrast to several other endothelial-cell reactive MAbs, were found to react highly specifically with sinus endothelial cells as tested by immunohistochemistry on bone marrow tissue sections and cell culture preparations and by double-colored FACS analysis on bone marrow MNCs (BMMNC). Sorted cells, which formed 0.05% of the MNC fraction, showed strong intracytoplasmic von Willebrand factor positivity. Ultrastructural analysis revealed cells with endothelial characteristics. Cells were cultured in fibronectin-coated, 24-well culture plates in endothelial-cell culture medium or long-term bone marrow culture medium. After 1 to 3 weeks of culture, a monolayer of spindle-shaped cells developed expressing endothelial cell antigens. Cells could be kept in culture for 4 to 6 weeks. In conclusion, the method described provides highly purified preparations of human bone marrow endothelium that may permit in vitro adhesion experiments with normal and leukemic hematopoietic progenitor cells.

Antibodies, Monoclonal↗

Evaluation of an immunomagnetic separation-real-time PCR assay for the rapid detection of Salmonella in meat.

The aim of this study was the comparison of an immunomagnetic separation (IMS)-real-time PCR assay for the detection of Salmonella with the cultural reference method according to and 35 of the German Law on Food and Commodities (LMBG, L 00.00.20:1998). The IMS-real-time PCR assay includes a nonselective preenrichment step, an IMS, DNA extraction, as well as DNA purification followed by hybridization probe-based real-time PCR analysis. An accurate comparability was achieved, because both methods analyzed the same preenrichment. The evaluation was carried out using both artificially and naturally contaminated meat samples. The IMS-real-time PCR assay provides a result after 12 to 13 h. Compared with the reference method and regarding artificially contaminated meat samples, the IMS-real-time PCR assay achieved a specificity of 80% (false-positive rate of 20%) and a sensitivity of 100% (false-negative rate of 0%). The relative accuracy was 94%. The detection limit of both methods was 10 CFU/25 g. The concordance index kappa, which defines the statistical accordance, was 0.85 and indicated the agreement of both methods on statistical criteria. Compared to the reference method and analyzing naturally contaminated meat samples (n = 491), the IMS-real-time PCR assay showed a specificity of 99.3% (false-positive rate of 0.7%) and a sensitivity of 83.7% (false-negative rate of 16.3%). The relative accuracy was 98%. The concordance index kappa had a value of 0.87 and highlighted the statistical agreement of both methods. In conclusion, the IMS-real-time PCR assay is suitable as specific, sensitive, and rapid screening method for the detection of Salmonella from meat.

Animals↗

Rapid and sensitive immunomagnetic separation-polymerase chain reaction method for the detection of Escherichia coli O157:H7 in raw milk and ice-cream.

Escherichia coli O157:H7 in spiked samples of raw milk and ice-cream was enriched in tryptic soy broth for 4 h, captured by immunomagnetic separation, subjected to amplification by polymerase chain reaction of parts of the verotoxin genes (SLT-I and SLT-II), and detected by agarose gel electrophoresis. Using this method, as few as 1 cfu Esch. coli O157:H7/g food could be detected in < 10 h.

Animals↗

Detection of Chlamydophila abortus in ovine milk by immunomagnetic separation-polymerase chain reaction.

The present study was carried out to investigate the presence of Chlamydophila abortus, the causative agent of ovine enzootic abortion, in milk samples collected from sheep flocks with and without the history of abortion in Eastern Turkey by means of immunomagnetic separation (IMS) in conjunction with the polymerase chain reaction (PCR). A total number of 201 milk samples collected from 10 flocks with abortion and four flocks without abortion were tested. In the analysis of the milk samples by IMS-PCR, correct amplification was obtained with three (1.5%) samples originating from one flock with abortion. In the digestion of PCR positive products by AluI, restriction profiles observed in all three samples were determined to be the same as C. abortus S26/3.

Abortion, Veterinary↗

Detection of Helicobacter pylori gene by means of immunomagnetic separation-based polymerase chain reaction in feces.

BACKGROUND: Detection of Helicobacter pylori is usually performed by culture, polymerase chain reaction (PCR), histology, or urease test on gastric biopsy samples. Although methods based on feces are non-invasive, their sensitivity has been relatively low. In this study, to improve its sensitivity, immunomagnetic separation (IMS) was used as a pre-PCR step for direct detection of H. pylori in feces. METHODS: Fresh fecal samples were taken from 72 patients attending for endoscopy. Of these, 57 patients had a positive H. pylori status according to the results of culture, histology, and PCR on gastric biopsy samples. Anti-H. pylori antibody-sensitized immunomagnetic beads were used to concentrate the bacteria. PCR was then performed to detect the H. pylori urease A-encoding gene. RESULTS: Of the 57 H. pylori-positive patients, 35 (61.4%) had positive fecal samples by IMS-based PCR method. None of the 15 H. pylori-negative patients had positive fecal samples. The sensitivity of this method was 61.4%, and the specificity 100.0%. CONCLUSIONS: This study confirms that non-invasive diagnosis of H. pylori infection could be made from feces by using IMS-based PCR.

Feces↗

Application of a novel immunomagnetic separation-bacteriophage assay for the detection of Salmonella enteritidis and Escherichia coli O157:H7 in food.

Salmonella infection is the second most prevalent cause of foodborne illness in most developing countries. Meat, poultry, and dairy products are frequently implicated in outbreaks. The objective of this study was to apply a novel immunomagnetic separation (IMS)-bacteriophage assay to the detection of Salmonella enteritidis in artificially inoculated skimmed milk powder, chicken rinses, and ground beef. In all food types tested, the IMS-bacteriophage assay was able to detect an average of 3 CFU of S. enteritidis in 25 g or ml of food sample. Total assay time including pre-enrichment is about 20 h. The results indicate that the IMS-bacteriophage assay is a rapid and sensitive means of detecting S. enteritidis in these foods. The assay was successfully adapted to the detection of Escherichia coli O157:H7 and was able to detect E. coli in ground beef at the lowest inoculation level tested, 2 CFU/g. The assay was also adapted to the simultaneous detection of S. enteritidis and E. coli. The results indicate that the IMS-bacteriophage assay shows promise for the simultaneous detection of these pathogens, but further development work would be necessary to improve sensitivity and produce reliable results at low inoculation levels.

Animals↗

An immunomagnetic separation-reverse transcription polymerase chain reaction (IMS-RT-PCR) test for sensitive and rapid detection of viable waterborne Cryptosporidium parvum.

The public health problem posed by the waterborne parasite Cryptosporidium parvum incited the water supply industry to develop very accurate analytical tools able to assess the presence of viable oocysts in drinking water. In this study, we report the development of a viability assay for C. parvum oocysts based on immunomagnetic separation and reverse transcription polymerase chain reaction (IMS-RT-PCR). The detection limit of the IMS-RT-PCR assay, which targets the hsp70 heat shock-induced mRNA, was in the range of ten viable oocysts per 100-l tap water samples. Purified Cryptosporidium parvum oocysts were exposed to heating, freezing and three chemical disinfection treatments namely, chlorination, chlorine dioxide treatment and ozonation under conventional doses used in water treatment plants, then detected by IMS-PCR and IMS-RT-PCR. The results obtained by IMS-PCR showed that none of the treatments had an effect on oocyst detection. The inactivation of oocysts by boiling resulted in no RT-PCR signal. Chlorine as well as chlorine dioxide did not influence oocyst viability as determined by IMS-RT-PCR. Ozone more effectively inactivated oocysts. The IMS-RT-PCR assay in conjunction with IMS-PCR marks the development of a combined detection and viability test which can be used for drinking water quality control as well as for reliable evaluation of treatment efficiency.

Animals↗

Development of an immunomagnetic separation-polymerase chain reaction (IMS-PCR) assay specific for Enterocytozoon bieneusi in water samples.

AIMS: Microsporidia have become widely recognized as important human pathogens. Among Microsporidia, Enterocytozoon bieneusi is responsible for severe gastrointestinal disease. To date, no current therapy has been proven effective. Their mode of transmission and environmental occurrence are poorly documented because of the lack of detection methods that are both species-specific and sensitive. In this study, we developed a sensitive and specific molecular method to detect E. bieneusi spores in water samples. METHODS AND RESULTS: The molecular assay combined immunomagnetic separation (IMS) and polymerase chain reaction (PCR) amplification to detect E. bieneusi spores. A comparison was made of IMS magnetic beads coated with two different monoclonal antibodies, one specific for the Encephalitozoon genus that cross-reacts with E. bieneusi and the other specific only for the E. bieneusi species itself. CONCLUSIONS: Immunotech beads coated with the antibody specific for E. bieneusi were found to be the most effective combination. SIGNIFICANCE AND IMPACT OF THE STUDY: The highly specific IMS-PCR assay developed in this study provides a rapid and sensitive means of screening water samples for the presence of E. bieneusi spores.

Antibodies, Protozoan↗

Combined immunomagnetic separation-molecular beacon-reverse transcription-PCR assay for detection of hepatitis A virus from environmental samples.

In this study, a molecular-beacon-based real-time reverse transcription (RT)-PCR assay was developed to detect the presence of hepatitis A virus (HAV) in environmental samples. A 125-bp, highly conserved 5' noncoding region of HAV was targeted. The sensitivity of the real-time RT-PCR assay was tested with 10-fold dilutions of viral RNA, and a detection limit of 1 PFU was obtained. The specificity of the assay was demonstrated by testing with other environmental pathogens and indicator microorganisms, and only HAV was positively identified. When combined with immunomagnetic separation, the real-time RT-PCR assay successfully detected as few as 20 PFU in seeded groundwater samples. Because of its simplicity and specificity, this assay has broad applications for the rapid detection of HAV in contaminated foods or water.

Fresh Water↗