PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Insufflation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Maternal insufflation during the second trimester equivalent produces hypercapnia, acidosis, and prolonged hypoxia in fetal sheep.

BACKGROUND: Anecdotal reports suggest that the second trimester is the safest time to conduct a laparoscopic procedure on a pregnant patient, but this supposition has not been tested empirically. METHODS: Previously instrumented preterm sheep (total n = 8) at gestational day 90 (term, 145 days) were anesthetized and then insufflated with carbon dioxide for 60 min at a pressure of 15 mmHg. Cardiovascular parameters were continuously recorded while blood gas status was determined before and at 15-min intervals during and up to 2 h after insufflation. RESULTS: Insufflation produced minimal maternal blood gas or cardiovascular changes except for a significant reduction in uterine blood flow. The decrease in perfusion increased fetal arterial blood partial pressure of carbon dioxide and decreased fetal pH, oxygen saturation, and oxygen content; there was also progressive fetal hypotension and bradycardia. After manually deflating the ewe, uterine blood flow returned to normal, and the fetal partial pressure of carbon dioxide and pH changes resolved within 1 h. However, fetal oxygen saturation and content remained depressed, and fetal cardiovascular status continued to decline during the 2-h postinsufflation monitoring period. CONCLUSION: Previous studies with near-term sheep determined that carbon dioxide pneumoperitoneum produces respiratory acidosis but does not decrease fetal oxygenation. In contrast, the current findings indicate that in the preterm fetus, insufflation-induced hypercapnia and acidosis are accompanied by prolonged fetal hypoxia and cardiovascular depression. This result suggests that additional work should be conducted to confirm the presumed safety of conducting minimally invasive procedures during the second trimester.

Acidosis↗

Tracheal gas insufflation combined with high-frequency oscillatory ventilation.

OBJECTIVES: To determine the efficacy of tracheal insufflation delivered by two different catheter designs on CO2 elimination when used in conjunction with high-frequency oscillatory ventilation. DESIGN: A nonrandomized before and after trial. Each animal served as his own control. SUBJECTS: Ten mongrel dogs weighing 20.9 +/- 1.9 kg. Four animals were assigned to a normal lung group and six animals underwent lung injury by large volume saline lavage. INTERVENTION: Permissive hypercapnia was allowed to occur by selecting oscillator settings that would lead to alveolar hypoventilation. Proximal mean airway pressure was kept constant. Tracheal gas was insufflated at 1 cm above the carina for 30 min periods at gas flows of 5 to 15 L/min. MEASUREMENTS AND MAIN RESULTS: Carinal pressure, hemodynamic parameters (cardiac output, mean arterial pressure, pulmonary artery occlusion pressure), and gas exchange parameters (PaCO2, PaO2, PaO2/FIO2, shunt fraction, D O2) were measured. For the normal dogs, at catheter flow of 15 L/min; the forward thrust catheter increased carinal pressure and Pao2/FIO2 BY 30% (p<.003) and 105% (p<.005), respectively. The forward thrust catheter reduced Paco2 by 40% (p<.04). The reverse thrust catheter increased PaO2/FIO2 by 102% (p<.001) and decreased pressure and PaCO2 by 44% (p<.001) and 34% (p<.003), respectively. For the injured dogs, at catheter flow rate of 15 L/min, the forward thrust catheter increased carinal pressure, PaO2, and PaO2/FIO2 by 6% (p<.001), 23% (p<.001), and 24% (p<.02), respectively. The forward thrust catheter reduced PaCO2 by 29% (p<.002). The reverse thrust catheter increased PaO2 and PaO2/FIO2 both by 11% (p<.02) and reduced carinal pressure and PaCO2 by 23% (p<.001) and 18% (p<.002), respectively. CONCLUSIONS: Tracheal gas insufflation is capable of improving oxygenation and ventilation in acute lung injury when combined with high-frequency oscillatory ventilation. The addition of this second gas flow at the level of the carina raises or lowers distal airway pressure, the magnitude of which is dependent on the direction and rate of gas flow. The beneficial effects of tracheal gas insufflation may be tempered by the long-term effects of altering distal airway pressure; lowering distal airway pressure may lead to atelectasis, whereas raising distal airway pressure may lead to an auto-positive end-expiratory pressure (auto-PEEP) effect.

Animals↗

Bedside placement of transpyloric feeding tubes in the pediatric intensive care unit using gastric insufflation.

OBJECTIVE: To test the effectiveness of gastric insufflation as an adjunct to placement of feeding tubes in the small bowel. DESIGN: Prospective, randomized, controlled study. SETTING: Pediatric intensive care unit in a tertiary children's hospital. PATIENTS: A total of 50 children requiring enteral nutrition via a nasoenteral feeding tube in the small bowel. INTERVENTIONS: An unweighted nasoenteral feeding tube attached to a three-way stopcock and a 60 mL syringe was inserted through the nares into the stomach. After 10 mL/kg of air was injected, the tube was advanced a distance estimated to position the tip of the tube proximal to the pylorus. An additional 10 mL/kg of air was then injected, and the tube was advanced a distance needed to place the tube in the fourth part of the duodenum. In the control group, feeding tubes were inserted through the nares and into the stomach. The tube was then advanced a distance estimated to place the tube in the fourth part of the duodenum. No air was injected in the control group. MEASUREMENTS AND MAIN RESULTS: When gastric insufflation was used, 23 of 25 feeding tubes were successfully placed in the small bowel on the first attempt compared with 11 of 25 in the control group (p = .001). All feeding tubes were successfully placed after two attempts in the gastric insufflation group compared with 18 of 25 in the control group (p < .001). The time between the first attempt at placement of a transpyloric feeding tube and the initiation of feeding was significantly shorter in the study group than in the control group. There were no complications in either group. CONCLUSION: Gastric insufflation allows rapid placement of feeding tubes into the small bowel with fewer attempts compared with a standard insertion technique in children.

Child, Preschool↗

Comparison between intraperitoneal CO2 insufflation and abdominal wall lift on QT dispersion and rate-corrected QT dispersion during laparoscopic cholecystectomy.

This study compared the effect of intraperitoneal CO2 insufflation with abdominal wall lift on RR interval, QT interval, the rate-corrected QT (QTc) interval, QT dispersion (QTD), and the rate-corrected QTD (QTcD) using computerized measurement during laparoscopic cholecystectomy. Thirty patients scheduled for laparoscopic cholecystectomy were randomly assigned to 2 groups: intraperitoneal CO2 insufflation (CO2 group) or abdominal wall lift (lift group). A 12-lead electrocardiogram was monitored to measure parameters. The RR interval, QT interval, and QTc interval did not change significantly during the study in both groups. The QTD and QTcD in the CO2 group increased significantly during CO2 insufflation, and were significantly higher than those of the lift group. Statistically significant increases of QTD and QTcD, which are associated with an increased risk of arrhythmias and cardiac events, occur during CO2 insufflation, and QTD and QTcD in the CO2 group were significantly higher than those of the lift group.

Abdominal Wall↗

Mechanical insufflation-exsufflation vs. tracheal suctioning via tracheostomy tubes for patients with amyotrophic lateral sclerosis: a pilot study.

OBJECTIVE: To compare the effects of mechanical insufflation-exsufflation vs. suctioning via tracheostomy tubes on respiratory variables for six amyotrophic lateral sclerosis patients. DESIGN: In this prospective crossover study, six consecutive patients with amyotrophic lateral sclerosis who required continuous mechanical ventilation via tracheostomy tubes and developed chest infections underwent measurement of pulse oxyhemoglobin saturation (SpO2), peak inspiratory pressure (PIP), mean airway pressure (Pawm), and work of breathing performed by the ventilator (WOBv) at baseline and 5 and 30 min after tracheal suctioning and 5 min after mechanical insufflation-exsufflation. RESULTS: The baseline values were 93.50 +/- 2.26% for SpO2 in ambient air, 18.50 +/- 4.23 cm H2O for PIP, 4.67 +/- 1.37 cm H2O for Pawm, and 1.03 +/- 0.25 J/liters for WOBv. Only WOBv changed significantly, decreasing after tracheal suctioning (P < 0.05), whereas all variables improved significantly after mechanical insufflation-exsufflation. CONCLUSION: For ventilator-dependent patients with amyotrophic lateral sclerosis, mechanical insufflation-exsufflation via a tracheostomy tube with an inflated cuff may be more effective in eliminating airway secretions than conventional tracheal suctioning.

Amyotrophic Lateral Sclerosis↗

Nasopharyngeal oxygen insufflation following pre-oxygenation using the four deep breath technique.

This paper evaluates the effectiveness of nasopharyngeal oxygen insufflation following preoxygenation using the four deep breath technique within 30 s, on the onset of haemoglobin desaturation during the subsequent apnoea. Thirty ASA I or II patients were randomly allocated to one of two groups. In the study group (n = 15), pre-oxygenation was followed by insufflation of oxygen at a flow of 5 l.min(-1) via a nasopharyngeal catheter commenced at the onset of apnoea. In the control group, pre-oxygenation was not followed by nasopharyngeal oxygen insufflation (n = 15). In the control group, SpO2 fell to 95% within a mean (SD) apnoea time of 3.65 (1.15) min, whereas in the study group, SpO2 was maintained in all patients at 100% throughout the 6 min of apnoea, at which point apnoea was terminated and positive pressure ventilation commenced. We conclude that nasopharyngeal oxygen insufflation following pre-oxygenation using the four deep breath technique can delay the onset of haemoglobin desaturation for a significant period of time during the subsequent apnoea.

Adult↗

Effects of carbon dioxide insufflation combined with changes in body position on blood gas and acid-base status in anesthetized llamas (Llama glama).

OBJECTIVE: To study the combined effects of intra-abdominal CO2 insufflation with changes in body position during laparoscopy in xylazine-ketamine-halothane anesthetized llamas. STUDY DESIGN: Prospective, controlled study. ANIMALS: Nine castrated, male llamas weighing 114 +/- 23 kg, 3 to 13 years old. METHODS: Three llamas (preliminary study [PS] group) were used to study the effect of right, lateral, dorsal, and left lateral recumbency on gas exchange and acid-base status. The other six (experimental study [ES] group) were used to study the combined effects of changes in body position and CO2 insufflation to an intraabdominal pressure of 10 to 12 mm Hg. Heart rate, respiratory rate, and indirect arterial blood pressures (systolic [SAP], mean [MAP], and diastolic [DAP]) were recorded every 5 minutes during anesthesia. Arterial blood gases (PaO2 and PaCO2) and acid-base status (pHa and HCO3-) were measured immediately after induction of anesthesia and before each change of position. RESULTS: In the PS group, significant decreases in SAP, MAP and PaCO2 and increases in PaO2 and pHa were observed when the llamas were turned from right lateral to dorsal recumbency. Values for HCO3- were lower than the postinduction values, but they remained unaffected by the changes in position. In the ES group, values for MAP were significantly lower when the llamas were placed in dorsal and left lateral recumbency than those observed during right lateral recumbency. Arterial O2 tension during right lateral recumbency was lower but returned to preinsufflation values when the llamas were placed in the dorsal position. All llamas recovered uneventfully within 30 minutes after termination of anesthesia. CONCLUSIONS: Insufflation of CO2 and changing body position induce minor and transient changes in cardiovascular and respiratory function. CLINICAL RELEVANCE: Laparoscopy with mild intra-abdominal CO2 insufflation (10 to 12 mm Hg) can be used safely in spontaneously breathing llamas anesthetized with xylazine, ketamine, and halothane.

Acid-Base Equilibrium↗

Expiratory phase tracheal gas insufflation and pressure control in sheep with permissive hypercapnia.

Tracheal gas insufflation (TGI) has been shown to be a useful adjunct to mechanical ventilation, decreasing PaCO2 during permissive hypercapnia. While TGI can be used either with pressure (PCV) or volume-controlled ventilation and continuously or only during the expiratory phase (Ex-TGI), there are no controlled studies evaluating the effects of Ex-TGI with PCV in acute lung injury when the direction of the insufflated flow or the inspiratory:expiratory (I:E) ratio are varied. We evaluated the effect that Ex-TGI with PCV would have on CO2 removal during both direct and reverse insufflated flow direction with varied I:E ratios when peak airway pressure, total positive end-expiratory pressure (PEEP), and tidal volume (VT) were kept constant. In addition we examined the effect that insufflation flow directed toward the mouth (reverse flow) would have on the generation of PEEP compared with flow directed toward the carina (direct flow). After saline lavage, nine sheep were ventilated with PCV to a baseline PaCO2 of 80 mm Hg. Ex-TGI (10 L/min) was then randomly applied in the reverse and direct direction with I:E set at 1:2 or 2:1. During 1:2 I:E PaCO2 decreased from 78 +/- 4 mm Hg to 60 +/- 7 mm Hg (23.5 +/- 8.9%) with direct flow and to 64 +/- 5 mm Hg (18.5 +/- 5.5%) with reverse flow (p < 0.05), whereas during 2:1 I:E PaCO2 decreased from 80 +/- 4 mm Hg to 69 +/- 8 mm Hg (13.7 +/- 9.2%) with direct flow and to 66 +/- 4 mm Hg (17.2 +/- 4.4%) with reverse flow (p < 0.05). Greater PEEP was developed with direct flow (2.8 cm H2O I:E 1:2 and 4.0 cm H2O I:E 2:1) than with reverse flow (-0.9 cm H2O I:E 1:2 and -0.4 cm H2O I:E 2:1), p < 0.05. There was no difference in the PaCO2 change between I:E with reverse flow, but the PaCO2 decrease was greater (p < 0.05) during 1:2 versus 2:1 I:E with direct flow. CO2 removal during PCV and Ex-TGI is more consistent with reverse flow than with direct flow and PEEP level is less affected by TGI with reverse flow than with direct flow.

Animals↗

Cardiopulmonary, blood and peritoneal fluid alterations associated with abdominal insufflation of carbon dioxide in standing horses.

REASONS FOR PERFORMING STUDY: Abdominal insufflation is performed routinely during laparoscopy in horses to improve visualisation and facilitate instrument and visceral manipulations during surgery. It has been shown that high-pressure pneumoperitoneum with carbon dioxide (CO2) has deleterious cardiopulmonary effects in dorsally recumbent, mechanically ventilated, halothane-anaesthetised horses. There is no information on the effects of CO2 pneumoperitoneum on cardiopulmonary function and haematology, plasma chemistry and peritoneal fluid (PF) variables in standing sedated horses during laparoscopic surgery. OBJECTIVES: To determine the effects of high pressure CO2 pneumoperitoneum in standing sedated horses on cardiopulmonary function, blood gas, haematology, plasma chemistry and PF variables. METHODS: Six healthy, mature horses were sedated with an i.v. bolus of detomidine (0.02 mg/kg bwt) and butorphanol (0.02 mg/kg bwt) and instrumented to determine the changes in cardiopulmonary function, haematology, serum chemistry and PF values during and after pneumoperitoneum with CO2 to 15 mmHg pressure for standing laparoscopy. Each horse was assigned at random to either a standing left flank exploratory laparoscopy (LFL) with CO2 pneumoperitoneum or sham procedure (SLFL) without insufflation, and instrumented for measurement of cardiopulmonary variables. Each horse underwent a second procedure in crossover fashion one month later so that all 6 horses had both an LFL and SLFL performed. Cardiopulmonary variables and blood gas analyses were obtained 5 mins after sedation and every 15 mins during 60 mins baseline (BL), insufflation (15 mmHg) and desufflation. Haematology, serum chemistry analysis and PF analysis were performed at BL, insufflation and desufflation, and 24 h after the conclusion of each procedure. RESULTS: Significant decreases in heart rate, cardiac output and cardiac index and significant increases in mean right atrial pressure, systemic vascular resistance and pulmonary vascular resistance were recorded immediately after and during sedation in both groups of horses. Pneumoperitoneum with CO2 at 15 mmHg had no significant effect on cardiopulmonary function during surgery. There were no significant differences in blood gas, haematology or plasma chemistry values within or between groups at any time interval during the study. There was a significant increase in the PF total nucleated cell count 24 h following LFL compared to baseline values for LFL or SLFL at 24 h. There were no differences in PF protein concentrations within or between groups at any time interval. CONCLUSIONS: Pneumoperitoneum with CO2 during standing laparoscopy in healthy horses does not cause adverse alterations in cardiopulmonary, haematology or plasma chemistry variables, but does induce a mild inflammatory response within the peritoneal cavity. POTENTIAL RELEVANCE: High pressure (15 mmHg) pneumoperitoneum in standing sedated mature horses for laparoscopic surgery can be performed safely without any short-term or cumulative adverse effects on haemodynamic or cardiopulmonary function.

Animals↗

[Effects of carbon dioxide insufflation during endoscopic conduit harvesting in coronary artery bypass surgery].

BACKGROUND: Endoscopic vessel harvesting is becoming common for the patients undergoing coronary artery bypass grafting. Insufflation of carbon dioxide (CO2) during the procedures has been reported elsewhere to affect arterial carbon dioxide tension, but the occurrence of hypercapnia is still controversial. METHODS: We investigated the effects of CO2 insufflation during endoscopic harvesting of the saphenous vein (SV, n = 34), radial artery (RA, n = 14), or internal mammary artery (IMA, n = 7) for coronary artery bypass surgery. The conduit harvesting was performed using Vasoview Dissecting Cannula with insufflation of CO2 maintaining a cavity pressure of 8-10 mmHg. RESULTS: After insufflation of CO2, significant elevation of partial pressure of CO2 in arterial blood (PaCO2) was found during harvesting of SV (35.4 +/- 3.8 to 49.2 +/- 7.5 mmHg, P < 0.01) and of IMA (38.0 +/- 2.3 to 44.2 +/- 3.2 mmHg, P < 0.05), but no significant elevation of PaCO2 occurred during RA harvesting using a tourniquet. The extent of PaCO2 elevation in SV harvesting showed negative correlation with patient's body weight, body mass index, and body surface area. CONCLUSIONS: Significant hypercarbia occurs during endoscopic harvesting of SV or IMA. It is recommended that PaCO2 should be carefully monitored during endoscopic conduit harvesting for coronary artery bypass surgery.

Aged↗

Improvement of visualization in computed tomographic colonography after mechanic air insufflation.

OBJECTIVE: Our aim was to develop an insufflation system for CT colonography enabling even and quick air inflation as well as pressure control and optional emergency decompression. PATIENTS AND METHODS: A modified air insufflation system for CT colonography, consisting of an electric air pump, manometer, safety valve, and a balloon tip is presented. Thirty one patients underwent CT colonography from August to December, 2004. RESULTS: Optimal distension was achieved in 30 patients; the distension was incomplete (partial) only in one case. The insufflation was performed within 60 seconds in 28 of the cases, in 2 patients--within 180 seconds and in one patient--after 180 seconds. CONCLUSIONS: The presented insufflation system allows optimization of CT colonography technique, reduces the risk of adverse events during examination and improves the precision of the method.

Air↗

Effect of oxygen insufflation during endotracheal suctioning on arterial pressure and oxygenation in coronary artery bypass graft patients.

BACKGROUND Numerous studies have demonstrated the need for increased inspired oxygen with endotracheal suctioning to prevent hypoxemia; however, increased arterial pressure has been reported as a consequence of lung hyperinflation/inflation used to deliver hyperoxygenation. OBJECTIVES To compare insufflation during endotracheal suctioning with a standard procedure of hyperoxygenation using a ventilator on arterial pressure, pulmonary artery pressure, heart rate, arterial oxygen saturation, and blood gases in intubated, mechanically ventilated coronary artery bypass graft patients. METHODS A within-subjects, repeated-measures design was used to measure arterial pressure (systolic, diastolic, and mean), pulmonary artery pressure (systolic, diastolic, and mean), airway pressure, heart rate and rhythm, arterial oxygen tension, arterial carbon dioxide tension, pH, and arterial oxygen saturation during an oxygen insufflation protocol and a hyperoxygenation protocol via the ventilator. RESULTS Using analysis of variance for repeated measures, statistically significant time effects were found for all variables. Statistically significant differences between protocols over time were found for arterial pressure, arterial oxygen tension, and arterial oxygen saturation. CONCLUSIONS Oxygen insufflation resulted in less increase in arterial pressure than did the hyperoxygenation protocol. The hyperoxygenation protocol resulted in hyperoxia. Based on this study, oxygen insufflation is a safe alternative for providing oxygen during endotracheal suctioning.

Blood Pressure↗

Randomized trial of different insufflation pressures for laparoscopic cholecystectomy.

BACKGROUND: The factors affecting cardiorespiratory changes and postoperative pain after laparoscopic cholecystectomy are poorly understood. The aim of this study was to assess these changes in patients undergoing laparoscopic cholecystectomy at an insufflation pressure of 7.5 or 15 mmHg. METHODS: Forty patients with similar preoperative characteristics were randomized, 20 to each group. RESULTS: There were no significant differences in intraoperative heart rate or cardiac index although the latter fell significantly soon after insufflation in both groups. The fall in cardiac index lasted longer (7 versus 2 min) and coincided with a slower rise in mean arterial pressure in those having 15 mmHg insufflation. Changes in peak airway pressure, end-tidal carbon dioxide and arterial blood gases were similar. After operation the low-pressure group had significantly less pain, better preservation of pulmonary function and were discharged home sooner (P = 0.015). CONCLUSIONS: Insufflation pressure significantly affects the haemodynamic changes and postoperative pain associated with laparoscopic cholecystectomy.

Carbon Dioxide↗

Cardiorespiratory effects of laparoscopy with and without gas insufflation.

BACKGROUND: Patients who are undergoing laparoscopic procedures can present with a number of ventilatory and circulatory problems. The use of a gasless technique for performing a laparoscopy by using a mechanical lifting device may potentially avoid such problems. OBJECTIVE: To compare the cardiorespiratory effects of laparoscopy with and without gas insufflation. METHODS: Twelve adult pigs were randomized to undergo a laparoscopy by using either carbon dioxide insufflation or mechanical elevation. Full invasive monitoring was performed preoperatively and at 10-minute intervals throughout the operative period. Parameters that were measured included blood gas determinations, mean arterial pressure, pulmonary arterial pressure, pulmonary capillary wedge pressure, central venous pressure, cardiac output, stroke volume, and total peripheral resistance. RESULTS: Carbon dioxide insufflation unlike mechanical elevation led to a fall in PO2 and absorption of a significant quantity of CO2, resulting in hypercapnia, acidosis, and a consequent hyperdynamic circulation. CONCLUSION: These findings have significant implications for the use of CO2 insufflation for laparoscopy in patients with a compromised respiratory or cardiac status.

Animals↗

Effects of intraduodenal air insufflation on sphincter of Oddi motility in conscious dogs.

To investigate effects of intraduodenal air insufflation on sphincter of Oddi motility, manometric recordings were obtained during fasting from the sphincter and duodenum in four conscious dogs with duodenal cannula. At 40% of the mean cycle length of the migrating motor complex predetermined from baseline recording, 160 ml of air was injected into the duodenum. In both the sphincter and duodenum, air insufflation produced premature phase III-like activity in seven of 20 experiments (35%) or nonspecific excitatory reaction in eight (40%). In the remaining five experiments (25%), the sphincter exhibited a transient inhibitory response, while the duodenum showed the nonspecific excitatory reaction. Basal pressure of the sphincter increased immediately after air insufflation in 90% of the 20 experiments. The mean basal pressure increased from 12.3 +/- 1.6 mm Hg to 22.4 +/- 2.1 mm Hg (P < 0.0001) and minimum basal pressure from 2.9 +/- 0.9 mm Hg to 4.7 +/- 0.8 mm Hg (P < 0.001). These results indicate that intraduodenal air insufflation does affect motility of the sphincter of Oddi and duodenum in conscious dogs.

Air↗

A comparison of air, CO2 and an air/CO2 mixture as insufflation agents for double contrast barium enema.

Using CO2 for DCBE is recommended as it may decrease pain afterwards but recent studies suggest it produces inferior distension. This prospective double blind study was designed to evaluate the use of an air/CO2 mixture. We randomised 105 patients to receive air, CO2 or a 50/50 mixture as the insufflation agent in DCBE. Gases were administered from prefilled bags. Those requiring additional insufflations before over couch films were recorded. Post procedure symptoms were evaluated by questionnaire. Distension and mucosal coating were assessed independently. There was no difference in mucosal coating. Those given CO2 had significantly less immediate and delayed pain compared to air and less delayed pain compared to the 50/50 mixture. Distension with air was graded better than with the other two agents but the difference did not reach statistical significance. However 50 % of patients receiving CO2 and 40 % of those receiving the mixture required additional insufflation before over couch films as distension was considered suboptimal, compared to 17 % of those given air, which was statistically significant. Our results indicate that using CO2 causes less pain than using air or the mixture although top up insufflations are often required to maintain adequate quality distension.

Adult↗

Intraoperative carbon dioxide colonoscopy: a safe insufflation alternative for locating colonic lesions during laparoscopic surgery.

BACKGROUND: Intraoperative colonoscopy (IOC) is useful for locating colonic pathologies during laparoscopy, but bowel distention compromises the subsequent visualization and procedure. Carbon dioxide (CO2), with its rapid absorption, has been proved effective for alleviating bowel distention in ambulatory settings. Its intraoperative role, however, has never been studied. This study aimed to assess the feasibility, safety, and advantages of CO2-insufflated IOC during laparoscopy. METHODS: For this study, CO2-insufflated IOC was performed for 20 patients under CO2 pneumoperitoneum. Parameters, including end-tidal CO2 (ETCO2) and minute volume, were prospectively registered. Time until resolution of bowel distention was determined by laparoscopic evaluation. RESULTS: All lesions were located by CO2-insufflated IOC in 15 min. During IOC, ETCO2 increased, but remained within normal values, and was quickly compensated with minimal hyperventilation. Bowel distention totally disappeared in 21 min, allowing immediate initiation of laparoscopic procedures under adequate visualization. CONCLUSIONS: The findings show that CO2-insufflated IOC during laparoscopy is feasible, safe, and of practical value for minimizing bowel distention without impeding the subsequent visualization and procedure.

Adult↗

Laparoscopy: searching for the proper insufflation gas.

BACKGROUND: Although many aspects of laparoscopic surgery have been determined, the question of which insufflation gas is the best arises repeatedly. The aim of this study was to review the findings on the major gases used today in order to provide information and guidelines for the laparoscopic surgeon. METHODS: We reviewed the literature for clinical and laboratory studies on the currently used laparoscopic insufflation gases: carbon dioxide (CO(2)), nitrous oxide (N(2)O), helium (He), air, nitrogen (N(2)), and argon (Ar). The following parameters were evaluated: acid-base changes, hemodynamic and respiratory sequelae, hepatic and renal blood flow changes, increase in intracranial pressure, outcome of venous emboli, and port-site tumor growth. RESULTS: The major advantage of CO(2) is its rapid dissolution in the event of venous emboli. Hemodynamic and acid-base changes with CO(2) insufflation usually are mild and clinically negligible for most patients. Although N(2)O is advantageous for procedures requiring local/regional anesthesia, it does not suppress combustion. Findings show that Ar may have unwanted hemodynamic effects, especially on hepatic blood flow. There are almost no hemodynamic or acid-base sequelae with the use of He, air, and N(2), but they dissolve slowly and carry a potential risk of lethal venous emboli. CONCLUSIONS: Clearly, CO(2) maintains its role as the primary insufflation gas in laparoscopy, but N(2)O has a role in some cases of depressed pulmonary function or in local/regional anesthesia cases. Other gases have no significant advantage over CO(2) or N(2)O and should be used only in protocol studies. The relation of port-site metastasis to a specific type of gas requires further research.

Air↗