PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Limit of Detection”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Improved detection limits and sensitivities of potentiometric titrations.

Zero-current ion fluxes through polymer membranes of ion-selective electrodes (ISEs) may lead to biased endpoints of potentiometric titrations. The bias is eliminated, and the sensitivity of the end-point detection is improved through reducing transmembrane ion fluxes by an appropriate choice of the inner solution. Surprisingly, ISE membranes that have a significant primary ion flux toward the inner solution show much larger sensitivities than expected by titration theory; however, depending on the experimental conditions, their application may bias the endpoint. With the optimal systems, endpoint detection is now possible with total sample concentrations below 10(-6) M, as demonstrated by the titration of EDTA with a Pb2+ solution.

Edetic Acid↗

Experimental assessment of the detection limit of genomic amplification by comparative genomic hybridization CGH.

Artificial amplicons of known size, constructed by use of YACs featuring human 8p12 and 12q13, were analyzed by comparative genomic hybridization (CGH). A minimum of 15 Mb of overrepresented DNA sequences could be detected. The sensitivity is (1) not dependent on the chromosome site and (2) related to the size of the amplicon, decreasing with decreasing size.

Chromosome Mapping↗

Improved detection limits for screening of diuretics by coupled liquid chromatography and ultraviolet-visible spectrophotometry.

Experimental conditions have been studied in order to improve the sensitivity for the analysis of diuretics and probenecid in urine samples by high-performance liquid chromatography with ultraviolet detection. Sample clean-up and chromatographic parameters have been optimized to obtain a suitable sensitivity for the detection or quantification of each diuretic using an HP-Hypersil ODS-C18 column (5 microns, 250 mm x 4 mm I.D.), taking into account the pharmacological properties of each compound. The reliability of this method was tested by analysing urine samples after a minimum single-dose administration of chlorthalidone and probenecid.

Chlorthalidone↗

The detection limits for estimates of infection intensity in schistosomiasis mansoni established by a study in non-human primates.

In human schistosomiasis mansoni, it is impossible to directly determine worm burden and hence infection intensity, so surrogates must be used. Studies on non-human primates revealed a linear relationship between worm burden and three surrogates, faecal egg output, circulating anodic and circulating cathodic antigens. By regression, the thresholds of detection were determined as 40, 24 and 47 worms, respectively. These observations provide a quantitative basis for the contention that low intensity infections in humans are being missed. The significance for estimates of disease prevalence, evaluation of the effects of chemotherapy and the implementation of vaccine trials is emphasised.

Animals↗

Two-fold differences are the detection limit for determining transgene copy numbers in plants by real-time PCR.

BACKGROUND: After transformation, plants that are homozygous and contain one copy of the transgene are typically selected for further study. If real-time PCR is to be used to determine copy number and zygosity, it must be able to distinguish hemizygous from homozygous and one-copy from two-copy plants. That is, it must be able to detect two-fold differences. RESULTS: When transgenic Nicotiana attenuata plants which had been previously determined by Southern analysis to contain one or two copies of the transgene, were analyzed by real-time PCR (2-delta delta Ct method), the method failed to confirm the results from the Southern analysis. In a second data set we analyzed offspring of a hemizygous one-copy plant, which were expected to segregate into three groups of offspring in a 1:2:1 ratio: no transgene, hemizygous, homozygous. Because it was not possible to distinguish homozygous from hemizygous plants with real-time PCR, we could not verify this segregation ratio. CONCLUSIONS: Detection of two-fold differences by real-time PCR is essential if this procedure is to be used for the characterization of transgenic plants. However, given the high variability between replicates, a detection of two-fold differences is in many cases not possible; in such cases Southern analysis is the more reliable procedure.

Computer Systems↗

Enzyme amplification for immunoassays. Detection limit of one hundredth of an attomole.

A method is described for increasing the response of enzyme immunoassays employing alkaline phosphatase as the label initiating 2 sequential catalytic reactions. First, NADP is dephosphorylated to produce NAD, which catalytically activates a specific redox-cycle involving the enzymes alcohol dehydrogenase and diaphorase. During each turn of the cycle 1 molecule of a tetrazolium salt is reduced to an intensely coloured formazan. The method is capable of detecting as little as 0.01 amol alkaline phosphatase, and when applied to an immunoassay for TSH a sensitivity (zero + 2.5 standard deviations) of 0.0013 mIU/l was obtained.

Alkaline Phosphatase↗

Lowering the detection limits of HIV-1 viral load using real-time immuno-PCR for HIV-1 p24 antigen.

Presently, the assay that attains maximal sensitivity and dynamic range of HIV-1 viral copy number (50 copies per milliliter) is nucleic acid amplification of HIV RNA in plasma. Enzyme-linked immunosorbent assay (ELISA) methods for quantification of HIV-1 p24 antigen have been relatively insensitive. In this report, we show data that indicate real-time immuno-polymerase chain reaction (IPCR), a combination of the ELISA and PCR techniques, is more sensitive for HIV-1 p24 antigen detection than other currently reported methods. When derived from an IPCR standard curve, a dose response was observed from patient samples with known viral loads diluted within a 3-log range (1.68-6,514 viral RNA copies per milliliter). IPCR detected 42% (22/52) of patient samples that had fewer than 50 viral RNA copies per milliliter by reverse transcriptase-PCR. IPCR shows the potential to become the most analytically sensitive test available for determination of HIV-1 viral load by the detection of HIV-1 p24 antigen.

Animals↗

Contact stress gradient detection limits of Pressensor film.

Fuji Pressensor film has been widely used for measurement of contact stresses in articular joints. In relatively smooth contact fields, measurement errors are reported to be in the range of approximately 10-15 percent. However, when local incongruities exist, strong contact stress gradients are present. This study investigates the film's capability to accurately transduce such gradients. Standardized stress distributions were produced by compressing the film between a rigid cylinder and an elastic layer supported by a rigid substrate. Seven different cylinder radii were used to obtain a range of gradient magnitudes. The resulting stains were digitized, and the contact stress gradients assessed by image analysis. Experimentally detected gradients were compared with those predicted analytically. The film's capability to reliably transduce contact stress gradients was shown to be sufficient for usage in the study of typical local articular incongruities.

Biomechanical Phenomena↗

Screening for thyroid disease in a primary care unit with a thyroid stimulating hormone assay with a low detection limit.

In a study at a primary care centre in a predominantly rural area of Sweden the records of all patients with established thyroid disease were scrutinised and 2000 consecutive adult patients screened with an immunoenzymometric thyroid stimulating hormone assay. The aims of the study were fourfold: firstly, to assess the total burden of thyroid disease in primary care centres in Sweden; secondly, to assess the efficacy of clinical diagnosis of the disease in unselected populations of patients; thirdly, to assess the efficacy of clinical evaluation of treatment with thyroxine; and, lastly, to see whether a single analysis of the serum thyroid stimulating hormone concentration by recent methods would be enough to identify an abnormality of thyroid function. Of the roughly 17,400 adults in the study community, 111 women and 10 men were being treated for thyroid disease. Screening detected 68 patients (3.5%) not receiving thyroxine who had a serum thyroid stimulating hormone concentration of 0.20 mU/l or less, all of whom were followed up clinically. Fifty of these patients were also studied biochemically during follow up. Only nine of the 68 patients had thyroid disease (three with thyrotoxicosis requiring treatment), no evidence of the disease being found in the remainder. Sixteen patients had spontaneous hypothyroidism requiring treatment, and neither these nor three patients with thyrotoxicosis had been detected at the preceding clinical examination. Of 35 patients in whom thyroid disease was suspected clinically at screening, none had laboratory evidence of thyroid dysfunction. In this series 1.3% of all women in the study community (2.6% of all 50-59 year olds) and 0.1% of the men were being treated for thyroid disease at the primary care centre, roughly 1.0% of adults subjected to screening were found to have thyroid disease requiring treatment, and most patients with a thyroid stimulating hormone concentration of 0.20 mU/l or less did not have thyroid dysfunction. It is concluded that measuring the basal serum thyroid stimulating hormone concentration by present methods is insufficient for the biochemical assessment of thyroid dysfunction in unselected populations.

Cross-Sectional Studies↗

Detection limits for ferrimagnetic particle concentrations using magnetic resonance imaging based proton transverse relaxation rate measurements.

A clinical magnetic resonance imaging (MRI) system was used to measure proton transverse relaxation rates (R2) in agar gels with varying concentrations of ferrimagnetic iron oxide nanoparticles in a field strength of 1.5 T. The nanoparticles were prepared by coprecipitation of ferric and ferrous ions in the presence of either dextran or polyvinyl alcohol. The method of preparation resulted in loosely packed clusters (dextran) or branched chains (polyvinyl alcohol) of particles containing of the order of 600 and 400 particles, respectively. For both methods of particle preparation, concentrations of ferrimagnetic iron in agar gel less than 0.01 mg ml(-1) had no measurable effect on the value of R2 for the gel. The results indicate that MRI-based R2 measurements using 1.5 T clinical scanners are not quite sensitive enough to detect the very low concentrations of nanoparticulate biogenic magnetite reported in human brain tissue.

Brain↗

Poly(ethylene glycol) limits of detection using internal matrix-assisted laser desorption/ionization Fourier transform mass spectrometry.

Detection limits of poly(ethylene glycol) were examined in the mass range 2000-6000 Da. Using an aerospray sample deposition technique, highly uniform sample surfaces were produced. This method allows signal averaging of spectra from up to 400 shots on the same sample spot. It is found that, as the material available for desorption is decreased, the overall average sample consumption per shot is decreased. Experimentally determined detection limits of 40 and 280 fmol (based on the average molecular masses of 2000 and 6000) were found for PEG 2000 and PEG 6000, respectively. The sample spectra show oligomer distributions in agreement with their higher concentration counterparts. However, at the lowest signal-to-noise levels, oligomers at the extremes of the distribution are no longer detected, making the polymer distribution appear to be narrower in mass range.

Microscopy, Electron, Scanning↗

Quantitative imaging of green fluorescent protein in cultured cells: comparison of microscopic techniques, use in fusion proteins and detection limits.

To determine the application limits of green fluorescent protein (GFP) as a reporter gene or protein tag, we expressed GFP by itself and with fusion protein partners, and used three different imaging methods to identify GFP fluorescence. In conventional epifluorescence photomicroscopy, GFP expressed in cells could be distinguished as a bright green signal over a yellow-green autofluorescence background. In quantitative fluorescence microscopy, however, the GFP signal is contaminated by cellular autofluorescence. Improved separation of GFP signal from HeLa cell autofluorescence was achieved by the combination of confocal scanning laser microscopy using 488-nm excitation, a rapid cut-on dichroic mirror and a narrow-bandpass emission filter. Two-photon excitation of GFP fluorescence at the equivalent of approximately 390 nm provided better absorption than did 488-nm excitation. This resulted in increased signal/background but also generated a different autofluorescence pattern and appeared to increase GFP photobleaching. Fluorescence spectra similar to those of GFP alone were observed when GFP was expressed as a fusion protein either with glutathione-S-transferase (GST) or with glucokinase. Furthermore, purified GST.GFP fusion protein displayed an extinction coefficient and quantum yield consistent with values previously reported for GFP alone. In HeLa cells, the cytoplasmic GFP concentration must be greater than approximately 1 microM to allow quantifiable discrimination over autofluorescence. However, lower expression levels may be detectable if GFP is targeted to discrete subcellular compartments, such as the plasma membrane, organelles or nucleus.

Base Sequence↗

Apyrase immobilized on paramagnetic beads used to improve detection limits in bioluminometric ATP monitoring.

A novel technique that is useful for the control of the luminescence output in a bioluminometric assay has been developed. The method relies on the immobilization on paramagnetic beads of an enzyme that is capable of catalysing the hydrolysis or oxidation of the substrate for the luminescence reaction. This technique has been used for control of the level of ATP in the luciferin-luciferase system. Biotinylated apyrase was bound to streptavidin coated paramagnetic beads and added to the assay mixture. The level of ATP in the reaction mixture was then conveniently controlled using an external magnet. The possible use of this approach in other systems, such as the bacterial luciferase-oxidoreductase is discussed.

Adenosine Triphosphate↗

Improved flow cytometric method to enumerate residual cells: minimal linear detection limits for platelets, erythrocytes, and leukocytes.

Increasing demand for quality control of blood products requires more sensitive methods to enumerate residual cells. Presently, the reported threshold (in cells per microliter) is 400 for red blood cells, 30-500 for platelets, and 1 for leukocytes. To examine precision and linearity in enumerating residual platelets and red blood cells, EDTA-anticoagulated blood from healthy donors was serially diluted with serum, stained in TruCount tubes using a no-lyse/no-wash procedure and a monoclonal antibody cocktail against the CD42a (FL1) and glycophorin-A (FL2) epitopes, and analyzed by flow cytometry. Leukocyte counts were determined in separate tubes. Cell preparation and analysis were performed once for 20 blood samples each and 20 times using the same specimen. Acquisition from the same tube was performed separately for platelets (threshold on FL1) and red blood cells (threshold on FL2). Multiparameter analysis was used for data evaluation. Linear results were obtained for platelets per microliter between 3,410 and 5 and for red blood cells per microliter between 54,000 and 3. For the lower cell concentrations, the coefficient of variation was 16.7% for platelets and 10.9% for red blood cells. The presented method allows the distinction between physiologically intact and ghost red blood cells. The method represents a reliable, sensitive, and accurate approach to quantify platelets and red blood cells in diluted blood. It can be applied to enumerate residual cells in plasma products and meets the increasing demand for quality control in blood components.

Antibodies, Monoclonal↗

Detection limits for matrix-assisted laser desorption of polypeptides with an external ion source Fourier-transform mass spectrometer.

Sensitivity in the low-femtomole range with mass resolution greater than 20,000 is demonstrated for several polypeptides analyzed by a mass spectrometer that pairs matrix-assisted laser desorption/ionization (MALDI) and Fourier-transform mass spectrometry (FTMS). The compounds investigated were substance P, renin substrate, melittin, the B-chain of bovine insulin, and bovine insulin. Standard solutions of the polypeptides were prepared with 30% acetonitrile+water, and micropipettes were used to transfer small amounts (1-20 fmol) to a sample probe. The samples were embedded in a large excess of matrix material (2,5-dihydroxybenzoic acid) and ionized by a pulse from an excimer laser. The FTMS instrument used for these experiments has the MALDI source in a separate chamber outside the magnetic field. Ions are extracted from the source and transported by an RF-only quadrupole ion guide to an FTMS analyzer cell mounted in the homogeneous region of a 6.5 T superconducting magnet. The high sensitivity of MALDI-FTMS is due, in part, to the high transfer efficiency of the ion guide, even for ions with a wide range of kinetic energies. The ion guide is easy to use because there are only two adjustments (RF amplitude and DC offset voltage), and unlike electrostatic ion transport means, alignment of it with the axis of the magnetic field is not critical. The mass resolution and sensitivity of MALDI-FTMS is compared with that of MALDI done with time-of-flight, magnetic sector, and quadrupole ion-trap mass spectrometers.

Amino Acid Sequence↗

Thermal modeling of snake infrared reception: evidence for limited detection range.

For more than 40 years, information has circulated with regard to the sensitivity of infrared pit organs in both boid and crotaline snakes (pythons and pit vipers, respectively). The most often quoted sensitivity is 0.003 degrees C and this value is based on the work of Bullock and co-workers (1956). Missing from previous work was a quantitative model of radiation transfer that would report sensitivity not in terms of degrees Celsius, but rather sensing distance. Since prey detection is often cited as the function of the infrared pit organ, quantification of this sensing distance seemed to be an important value that was missing from the literature. In this paper, we model the radiation transfer process from a 37 degrees C object, i.e. warm-blooded prey, to an infrared pit organ. The model tries to answer a very basic question-at what distance does the thermal signature of a 37 degrees C object blend into the background for a non-imaging biological infrared sensor? The output of the model, the sensing distance, is of particular interest in comparing biological infrared sensors to current semiconductor-based infrared (IR) detectors-largely because of inappropriate comparisons between the temperature sensitivity of IR snake reception and imaging IR cameras. The purpose of the presented work to make more appropriate comparisons, i.e. sensing distance. This sensing distance output indicates an extremely short detection distance (<5 cm)-contradictory to what is observed experimentally. This dichotomy raises further questions regarding how the biological system amplifies this weak signal.

Animals↗