PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “MOUTH PROTECTORS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Repositioning accuracy of fractionated stereotactic irradiation: assessment of isocentre alignment for different dental fixations by using sequential CT scanning.

BACKGROUND AND PURPOSE: To quantify the accuracy and reproducibility of patient repositioning in fractionated stereotactic conformal radiotherapy (SCRT) using dental fixations in conjunction with a stereotactic head mask. PATIENTS AND METHODS: One hundred and fourteen verification CT scans were performed on 57 patients in order to check set-up alignment. The first scan was done immediately after the first treatment. Twelve patients were checked for alignment accuracy with weekly CT scans over a period of 3-6 weeks, all others had 1-2 scans. Two different dental fixations were used in combination with a non-invasive mask system: an upper jaw support (35 patients) and a customised bite-block (17 patients). Five patients were treated with no additional fixation. Co-registration to the planning CT was used to assess alignment of the isocentre to the reference markers. Additionally, the intra-operator variability of image co-registration was assessed. RESULTS: There was a significant improvement of the overall alignment in using the bite-block instead of the upper jaw support (P<0.001). The mean deviation was for the bite-block 2.2+/-1.1 mm (1 SD), for the upper jaw support 3.3+/-1.8 mm and 3.7+/-2.8 mm for the mask alone. Overall isocentre deviations independent of the method of fixation were 2.8 mm (1.7 mm, 1 SD). Displacements in CC direction were significantly less for the bite-block compared to the upper jaw support (P=0.03). The addition of an upper jaw support significantly reduced lateral rotations compared to the mask system alone (P=0.03). The intra-operator variability of image co-registration was 1.59+/-0.49 mm (1 SD). CONCLUSION: The reproducibility of patient positioning using a re-locatable head mask system combined with a bite-block is within the reported range for similar devices and is preferable to a simple upper jaw support. In order to further reduce the margin for the planning target volume an intra-oral dental fixation is recommended.

Brain Neoplasms↗

A modified oral screen appliance to prevent self-inflicted oral trauma in an infant with cerebral palsy: a case report.

Self-inflicted oral trauma occurs in a number of conditions with different etiologic and clinical characteristics. The management of such trauma also varies depending on the medical history of the patient; the etiology of the behavior; and the severity, frequency, and method of inflicting injury. This case report describes a modified oral screen placed in a 10-month-old female infant with cerebral palsy who had been having feeding problems caused by self-inflicted oral trauma. The modified oral screen effectively protected the wounds against further oral trauma to the lower lip and tongue without being fixed to the dentition.

Biocompatible Materials↗

Congenital insensitivity-to-pain with anhidrosis (CIPA): a case report with 4-year follow-up.

Congenital Insensitivity-to-pain with anhidrosis (CIPA) is a rare disorder in which pain perception is absent from birth, despite the fact that all other sensory modalities remain intact or minimally impaired and tendon reflexes are present. The challenge in dentistry is to manage the self-mutilation behavior avoiding serious damages especially to oral structures, hands and fingers. A Brazilian case of CIPA is presented and discussed with clinical documentation of the oral-related problems over a 4-year follow-up. A conservative treatment (mouthguard-like appliance) was proposed with the objective to avoid full mouth extraction.

Consanguinity↗

Oxygenating mouthguard alleviates hypoxia during gastroscopy.

A randomized study was carried out to determine the effect of oxygen (3 liters/min) via a novel oxygenating mouthguard (Oxyguard) on arterial oxygenation in 242 intravenously sedated patients undergoing gastroscopy. In another group of 21 patients, a randomized crossover study of arterial oxygen saturation using either the standard mouthguard or the oxygenating mouthguard (3 liters/min) was conducted. Significant O2 desaturation (pulse oximeter reading less than 90%) occurred in 25% of patients on room air but only 3% of those on oxygen (p less than 0.001). Severe desaturation (reading less than 85%) occurred in 5% of patients on room air but was prevented by the oxygenating mouthguard. Minimum oxygen saturation levels were significantly higher in patients on oxygen (90.5 +/- 0.3%) than on air (86.5 +/- 0.5%; p less than 0.001). In the crossover group, O2 saturation was uniformly higher in the recordings of all patients using the oxygenating mouthguard. In conclusion, administration of oxygen via the oxygenating mouthguard alleviates hypoxemia during gastroscopy and prevents severe oxygen desaturation. However, hypoxemia may occur even during use of supplemental oxygen. Hence, monitoring of arterial oxygenation is recommended.

Equipment Design↗

Heat-cured silicone bimaxillary mouthguard.

A laboratory procedure for the construction of a heat-cured, silicone, custom-made bimaxillary mouthguard for contact sports is described. Contours and vertical dimension are easier to control than with the conventional thermoformed product, and there is no danger of injury from contact between the maxillary and mandibular components.

Dental Prosthesis Design↗

Hardness and shock absorption of silicone rubber for mouth guards.

Silicone rubbers have general properties that make them suitable for the fabrication of custom-made mouth guards. This study evaluated the shock absorption properties and Shore A hardness of several silicone rubbers and derived products, compared their values with those of materials commonly used for the manufacture of mouth guards, and correlated the shock absorption and transmission abilities of these different materials with their Shore hardness. Silicone rubbers absorb shock better than the materials currently used for custom-made mouth guards. In addition, to adapt mouth guards to particular sports, the properties of the silicone rubbers can be appropriately modified by the addition of oils or glass fiber reinforcement. Statistical analysis of hardness values and transmitted forces for the 27 materials tested indicates that the maximum transmitted force increases with hardness. However, this relationship is not linear, and departure from linearity is greatest for minimal and maximal hardness values.

Absorption↗

Improved mouth guard design for protection and comfort.

Mouth guards worn during contact sports have been shown to provide considerable protection against traumatic injuries to the teeth and supporting structures. Of the 3 types available, the custom-made mouth guard is considered superior to stock and mouth-formed mouth guards. The procedure for making a special mouth guard designed for protection and comfort is described.

Acrylic Resins↗

Shock absorption potential of different mouth guard materials.

STATEMENT OF PROBLEM: Clinical stresses and situations in the mouths of patients are substantially different; thus, it is not possible to make an exact in vivo comparison of the efficiency of various mouth guards. PURPOSE: This study developed a device and a method to test and quantify the potential of mouth guards to absorb shock and evaluated and compared 5 designs for mouth guards. MATERIAL AND METHODS: Strain gauges and accelerometer sensors were mounted in various positions on the maxilla and inside an artificial skull. Sensors quantified the response of several areas of the skull to inputs of force on the maxillary teeth protected by the mouth guard being investigated. Input of force was applied to the maxillary teeth with a modal hammer equipped with a load cell. Five mouth guards of each of 5 designs were manufactured and placed in position before force was applied to the maxillary teeth. All inputs were measured and analyzed and, from those results, a method was developed to quantify the relative potential of the mouth guards to absorb shock. This method was then used to quantify the shock absorption potential of the 5 types of mouth guard designs. RESULTS: All 5 types of mouth guards provided some measure of protection and were better than no protection. However, the level of protection provided by the 5 mouth guard designs differed.

Dental Stress Analysis↗

Instrumented indentation characterisation of mouth-guard materials.

OBJECTIVES: The aim of the study was to investigate the mechanical properties and energy absorption behavior of mouth-guard materials. Interpretation of indentation force-displacement data has been used to determine these properties. METHODS: An ultra micro-indentation system (UMIS) was used to determine near surface properties of mouth-guard materials with nanometer and micro-Newton displacement and force resolution. The measurement procedure was conducted with a small spherical steel indenter (R=500 microm), with impressions that were equally spaced (250 microm). Measurements of force-displacement response of surfaces at maximum forces of 10, 40 or 50 mN, 10 indentations were made at each of these forces. Tests were undertaken in two different modes to determine the mechanical properties, namely: (a) continuous load to the maximum force and then unload, (b) multiple loading and partially unloading sequence to the maximum load. RESULTS: The force-displacement results were analysed to determine the elastic modulus and contact pressure versus depth of penetration as well as the energy loss. Energy absorption for each material was determined from the ratio of the hysteresis energy loss to the total energy at maximum load and ranged from 10 to 24% among different mouth-guard materials. Energy absorption ratio, elastic modulus and contact pressure were significantly different between different materials with same thickness (FC, GC and C3) (p<0.01) and significantly different between materials with different thickness (C1 and C3) (p<0.01). SIGNIFICANCE: The present approach provides a simple and efficient method to readily measure the elastic-plastic (hysteretic) response of mouth-guard materials. The indentation technique lends itself to investigate the influence of ageing, heat treatment, sterilisation, moisture etc in a simple systematic manner.

Absorption↗