PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Optics and Refraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

A high-efficiency laser iridotomy-sphincterotomy lens.

A new laser iridotomy-sphincterotomy contact lens, bearing a 103-diopter optical button decentered 2.5 mm, gives the smallest iris focal spot and highest iris energy density practicably obtainable with a single optical glass refracting surface placed upon a thin Goldmann-type contact lens. By increasing iris energy density to a level 7.79 times greater than that from a plano contact lens and 2.92 times greater than that from the Abraham lens, the lens increases the iris burn temperature level above the threshold level for evaporative pyrolysis, even at exposures of 0.01 and 0.02 second, thus facilitating argon laser iridotomy and iris sphincterotomy by the linear incision method. Corneal and retinal energy exposures are greatly reduced. Used with the Nd-YAG laser, the lens increases efficiency for iridotomy and for division of vitreous bands in the anterior chamber.

Contact Lenses↗

AFM review study on pox viruses and living cells.

Single living cells were studied in growth medium by atomic force microscopy at a high--down to one image frame per second--imaging rate over time periods of many hours, stably producing hundreds of consecutive scans with a lateral resolution of approximately 30-40 nm. The cell was held by a micropipette mounted onto the scanner-piezo as shown in Häberle, W., J. K. H. Hörber, and G. Binnig. 1991. Force microscopy on living cells. J. Vac. Sci. Technol. B9:1210-0000. To initiate specific processes on the cell surface the cells had been infected with pox viruses as reported earlier and, most likely, the liberation of a progeny virion by the still-living cell was observed, hence confirming and supporting earlier results (Häberle, W., J. K. H. Hörber, F. Ohnesorge, D. P. E. Smith, and G. Binnig. 1992. In situ investigations of single living cells infected by viruses. Ultramicroscopy. 42-44:1161-0000; Hörber, J. K. H., W. Häberle, F. Ohnesorge, G. Binnig, H. G. Liebich, C. P. Czerny, H. Mahnel, and A. Mayr. 1992. Investigation of living cells in the nanometer regime with the atomic force microscope. Scanning Microscopy. 6:919-930). Furthermore, the pox viruses used were characterized separately by AFM in an aqueous environment down to the molecular level. Quasi-ordered structural details were resolved on a scale of a few nm where, however, image distortions and artifacts due to multiple tip effects are probably involved--just as in very high resolution (<15-20 nm) images on the cells. Although in a very preliminary manner, initial studies on the mechanical resonance properties of a single living (noninfected) cell, held by the micropipette, have been performed. In particular, frequency response spectra were recorded that indicate elastic properties and enough stiffness of these cells to make the demonstrated rapid scanning of the imaging tip plausible. Measurements of this kind, especially if they can be proven to be cell-type specific, may perhaps have a large potential for biomedical applications. Images of these living cells were also recorded in the widely known (e.g., Radmacher, M., R. W. Tillmann, and H. E. Gaub. 1993. Imaging viscoelasticity by force modulation with the atomic force microscope. Biophys. J. 64:735-742) force modulation mode, yet at one low modulation frequency of approximately 2 kHz. (Note: After the cells were attached to the pipette by suction, they first deformed significantly and then reassumed their original spherical shape, which they also acquire when freely suspended in solution, to a great extent with the exception of the portion adjusting to the pipette edge geometry after approximately 0.5-1 h, which occurred in almost the same manner with uninfected cells, and those that had been infected several hours earlier. This seems to be a process which is at least actively supported by the cellular cytoskeleton, rather than a mere osmotic pressure effect induced by electrolyte transport through the membrane. Furthermore, several hours postinfection (p.i.) infected cells developed many optically visible refraction effects, which appeared as small dark spots in the light microscope, that we believed to be the regions in the cell plasma where viruses are assembled; this is known from the literature on electron microscopy on pox-infected cells and referred to there as "virus factories" (e.g., Moss, B. 1986. Replication of pox viruses. In Fundamental Virology, B. N. Fields and D. M. Knape, editors. Raven Press, New York. 637-655). Therefore, we assume that the cells stay alive during imaging, in our experience for approximately 30-45 h p.i.).

Animals↗

Diving and hyperbaric ophthalmology.

Exposure of the human body to ambient pressures greater than that at sea level may result in various disorders, some of which have ocular manifestations. Additionally, some eye disorders and postoperative states may be adversely affected by the underwater environment or other hyperbaric exposures. The prevalence of recreational, military, and commercial diving, as well as the medical use of hyperbaric oxygen therapy, requires that ophthalmologists be familiar with the effects of the hyperbaric environment on the normal and diseased eye. The ophthalmology and diving medical literatures were surveyed for publications relating to the ophthalmic aspects of diving and hyperbaric exposures. Underwater optics, underwater refractive correction, and ophthalmic aspects of a fitness-to-dive evaluation are summarized. The evaluation and management of ocular manifestations of decompression sickness and arterial gas embolism are reviewed and guidelines for diving after ocular surgery are proposed.

Barotrauma↗

Results of phase III excimer laser photorefractive keratectomy for myopia. The Summit PRK Study Group.

OBJECTIVE: The purpose of the study is to determine safety and efficacy outcomes of excimer laser photorefractive keratectomy (PRK) for the treatment of mild-to-moderate myopia. DESIGN: A prospective, multicenter, phase III clinical trial. PARTICIPANTS: A total of 701 eyes of 701 patients were entered in the study; 612 eyes were examined at 2 years after surgery. INTERVENTION: Intervention was photorefractive keratectomy using the Summit ExciMed UV200LA excimer laser (Summit Technology, Inc., Waltham, MA). The treatment zone diameter used was 4.5 mm in 251 eyes (35.8%) and 5 mm in 450 eyes (64.2%). Attempted corrections ranged from 1.50 to 6.00 diopters (D). MAIN OUTCOME MEASURES: Predictability and stability of refraction, uncorrected and spectacle-corrected visual acuity, refractive and keratometric astigmatism, corneal haze, contrast sensitivity, subjective reported problems of glare and halo, and patient satisfaction were the parameters measured. RESULTS: At 2 years, 407 (66.5%) eyes achieved 20/20 or better uncorrected visual acuity and 564 (92.5%) eyes achieved 20/40 or better visual acuity. Three hundred thirty-six (54.9%) eyes were within 0.5 D and 476 (77.8%) eyes were within 1.0 D of attempted correction. Stability of refraction improved with time; 86.8% of eyes were stable within 1.0 D from 6 to 12 months, 94% were stable from 12 to 18 months, and 96.3% were stable from 18 to 24 months. There was no evidence of progressive or late myopic or hyperopic refractive shifts. One hundred fourteen (18.6%) eyes gained 2 or more lines of spectacle-corrected visual acuity, whereas 42 (6.9%) eyes lost 2 or more lines; however, of the latter, 32 (76.2%) had spectacle-corrected visual acuity of 20/25 or better and 39 (92.9%) eyes had 20/40 or better. Four hundred forty-two (72.2%) corneas were clear, 138 (22.5%) showed trace haze, 20 (3.3%) mild haze, 9 (1.5%) moderate haze, and 3 (0.5%) marked haze. On patient questionnaires, 87 (29.7%) patients reported worsening of glare from preoperative baseline; 133 (50.1%) reported worsening of halo symptoms from baseline. CONCLUSIONS: Photorefractive keratectomy appears effective for myopic corrections of -1.50 to -6.00 D. Uncorrected visual acuity is maximized in most eyes by 3 months, although some patients require between 6 months and 1 year to attain their best postoperative uncorrected visual acuity and some may require from 1 to 2 years for stabilization of refraction. Refraction stabilizes progressively without evidence of late myopic or hyperopic refractive shifts. Optical sequelae of glare and halo occur in some patients treated with a 4.5- or 5-mm treatment zone.

Adult↗

Complete on-line determination of biopolymer molecular weight via high-performance liquid chromatography coupled to low-angle laser light scattering, ultraviolet, and differential refractive index detection.

An optically modified high-performance liquid chromatography refractive index detector was developed to allow complete on-line determinations for biopolymer molecular weights. On-line concentration, refractive index, specific refractive index increment (dn/dc2)mu, and Rayleigh factor were determined under flow injection analysis (FIA) and size exclusion chromatography (SEC) conditions using low-angle laser light scattering, ultraviolet, and modified refractive index detection. This instrumental system is capable of determining absolute on-line molecular weights. The error and time requirements involved in conventional methodologies for proteins have been reduced. Sample quantities have been reduced from 150 to 200 mg, in conventional off-line methods, to less than 2 mg for on-line FIA and 0.5 mg for on-line SEC, if mass absorptivities (a) are known. Otherwise, the determination of a will be the most sample-demanding step, requiring about 3 mg of the pure protein. On-line measurements of (dn/dc2)mu are in good agreement with traditional off-line values established at Donnan equilibrium (usually within 5%). In addition, this technique provides true injected mass as determined by the UV detector, after chromatographic exposure where losses may occur, which is then used in the calculation of biopolymer molecular weight.

Calibration↗

Total internal reflection-based biochip utilizing a polymer-filled cavity with a micromirror sidewall.

A total internal reflection (TIR)-based biochip utilizing a polymer-filled cavity with a micromirror sidewall has been designed and fabricated. The implementation of the micromirror sidewall cavity facilitates precise alignment of the excitation light beam into the system. The incident angle of illumination can be easily modified by selecting polymers of different indices of refraction while optical losses are minimized. The design enables the hybrid, vertical integration of a laser diode and a CCD camera, resulting in a compact optical system. Brownian motion of fluorescent microspheres and real-time photobleaching of rhodamine 6G molecules is demonstrated. The proposed TIR-based chip simplifies current TIR optical configurations and could potentially be used as an optical-microfluidic platform for an integrated lab-on-a-chip microsystem.

Biosensing Techniques↗

Postnatal development of corneal curvature and thickness in the cat.

OBJECTIVE: To evaluate the postnatal development of central corneal curvature and thickness in the domestic cat. Animals studied Six Domestic Short-haired (DSH) kittens starting at 9 weeks of age and 6 adult cats. PROCEDURES: Kittens were evaluated biweekly to monthly for a 12-month period, starting at age 9 weeks. Corneal development was monitored by hand-held keratometry and ultrasound biomicroscopy. Standard regression analysis using a nonlinear least squares method was used to generate a formula that would predict corneal curvature as a function of age. RESULTS: Mean keratometry (K) values for the 9-week-old cats were 54.51 (+/-1.02) diopters (D) and these values steeply declined over the next 3 months to 44.95 (+/-0.90) D. Thereafter, K-values gradually decreased to reach a plateau by 12-15 months of age of 39.90 (+/-0.42) D. Because K-values still appeared to be slightly diminishing at this point, six other > 2-year-old cats were evaluated by keratometry and were found to have K-values of 38.99 (+/-0.81). Two to four diopters of astigmatism was common in young kittens whereas adult cats had a low mean degree of astigmatism (< 1 D). A formula that predicted keratometry values in diopters (K) as a function of age in weeks (w) was established as follows: K = 39.83 + 26.87 exp(-0.074 w). The central cornea increased in thickness primarily during the first 4 months of life with 9 week-old kittens having values of 0.379 (+/-0.012) mm; 16-week-old kittens, 0.548 (+/-0.021) mm and 67 week-old cats, 0.567 (+/-0.012) mm. CONCLUSIONS: The maturation process of the feline cornea proceeds over the first 1-2 years of life to attain an adult status that is characterized by a roughly spherical state of approximately 39 D corneal curvature, substantially flatter than the human cornea, and a central thickness similar to the human cornea. Research studies of the refractive or optical properties of the cornea in which cats are used as experimental animals should be conducted on animals greater than 18 months of age.

Animals↗

[Quantification of corneal aberrations with an aberration coefficient].

BACKGROUND: Abnormal corneal surfaces in keratoconus, contact lens induced corneal distorsion or after refractive surgery are thoroughly described by Zernike polynoms. This study investigated such deviations from the healthy eye by a newly introduced aberration coefficient. PATIENTS AND METHODS: 300 healthy eyes were measured with videokeratometry. Corneal Zernike coefficients (grade 1. - 8. degrees ) were used to calculate the aberration coefficient. This number was also determined for 113 eyes with keratoconus (videokeratometric stage 1 to 3 - 4), 326 eyes of contact lens wearers (200 soft and 126 hard lenses) and 119 eyes after Lasik surgery. RESULTS: In the keratoconus group the aberration coefficient was outside normal limits in 99.2 % and correlated well with the illness stage. Corneal distorsions of low extent appeared in 5 % of soft lens wearers without a difference between yearly or disposable replacement mode. The percentage of hard lens-induced distorsions was 39 % (low extent) and 5 % (considerable extent), respectively. Only 16.8 % of eyes after Lasik had a completely normal aberration coefficient; the rest lied between 1.0 - 1.5 (62.2 %), 1.6 - 2.0 (19.3 %) and > 2.0 (1.7 %). CONCLUSIONS: The aberration coefficient is a helpful tool for keratoconus classification, quality control of contact lens fitting and quantification of corneal aberrations after refractive surgery. Optical aberrations of the cornea after Lasik surgery are more widespread than presumed so far and reach a considerable extent in a fifth of the operated persons.

Contact Lenses↗

An analysis of the papers presented at the annual meetings of the American Academy of Optometry for the last twelve years.

The papers read at the annual meetings of the American Academy of Optometry by representatives from the schools of optometry for the last 12 years were analyzed. We tabulated the papers presented in the Sections and in the General Program. Topics were subdivided into binocular vision, ocular health, contact lenses, optics and refraction, etc. Some schools maintained a consistent level over the years whereas others varied in the number of papers read at the Academy meetings. The emphasis of some schools of optometry on certain fields of optometry became apparent.

Academies and Institutes↗

Simulation of light propagation by local spherical interface approximation.

A new local elementary interface approximation is introduced for the modeling of wave propagation through interfaces between homogeneous media. The incident wave and the surface profile are approximated locally by a spherical wave and a spherical surface, respectively. The wave field travels through the modulated structure according to the laws of geometrical optics, being refracted by the surface and propagating to the output plane locally as a geometric spherical wave. Diffraction theory is applied to propagate the field from the output plane onwards. We provide comparisons of the method with the thin-element approximation, the local plane-wave and interface approach, and rigorous diffraction theory using a sinusoidal surface-relief grating as an example. We illustrate the power of the new method by applying it to the analysis of a diffractive beam splitter.

Journal Article↗

Fabrication of an improved gray-scale mask for refractive micro- and meso-optics.

An experiment was performed on a new gray-scale mask material. The mask material is carbon based and has high attenuation in the deep ultraviolet spectral range. The experiment involves making a gray-scale mask for an axicon. Preliminary results show that gray-scale profiles of accurate transmittance functions can be fabricated. Potentially, the capability at deep ultraviolet wavelengths will allow the fabrication of high-resolution components. The high-attenuation characteristic will allow the production of microscale and mesoscale optics of more phase levels.

Journal Article↗

Optic sensors of high refractive-index responsivity and low thermal cross sensitivity that use fiber Bragg gratings of >80 degrees tilted structures.

For the first time to the authors' knowledge, fiber Bragg gratings (FBGs) with >80 degrees tilted structures have been fabricated and characterized. Their performance in sensing temperature, strain, and the surrounding medium's refractive index was investigated. In comparison with normal FBGs and long-period gratings (LPGs), >80 degrees tilted FBGs exhibit significantly higher refractive-index responsivity and lower thermal cross sensitivity. When the grating sensor was used to detect changes in refractive index, a responsivity as high as 340 nm/refractive-index unit near an index of 1.33 was demonstrated, which is three times higher than that of conventional LPGs.

Journal Article↗

Considerations in evaluation and treatment of the child with low vision.

Habilitation of infants and children with visual impairments should be based on a thorough understanding of their visual capabilities and limitations. Comprehensive evaluation of visual function includes measurement of visual acuity, contrast sensitivity, visual field, color vision, adaptation, visual sphere, accommodation, and oculomotor functions. It is best completed through a team approach that uses therapists, special educators, and physicians. A complete evaluation also includes examination of the effect of other motor functions on the use of vision. Nearly all aspects of a child's vision can be measured in play situations with tests that are easy to use. However, further education of nonphysician team members in refractive errors, optics, and function of optical devices may be necessary to ensure an accurate and thorough evaluation.

Adaptation, Ocular↗

Postoperative complications of excimer laser photorefractive keratectomy for myopia.

Excimer laser photorefractive keratectomy has become an increasingly popular surgical treatment for the correction of myopia. Unfortunately, no surgical technique can be entirely without complications. This article discusses the problems encountered following PRK for myopia in two main sections: those primarily refractive or optical in nature and those causing medical problems.

Cornea↗

[Biomechanical testing of DIAKOR implants by photoelastic stress analysis].

Diakor aluminium oxide implants of different forms and sizes have been investigated and compared by photoelastic stress analysis. On forming the conditions of investigations the authors aimed at the modelization based upon the physiological direct implant-bone contact, installing implants having resin that is optically double refractive. In the sample results show a move advantageous stress relation at multi grooved implants of extended dimensions.

Aluminum Oxide↗

[Ocular biometry in neonates (author's transl)].

Ocular biometry tests were conducted in approximately 100 full-term neonates (of both sexes) during the first five days following birth. Measured parameters included the dimensions and shape of the ocular globe, and optic component refractions. For the first time, individual values were determined for the corneal curvature radius, corneal refraction, and the transverse diameter and shape of the globe. Results are analyzed statistically, and the most important correlations calculated.

Anthropometry↗