PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Patient Navigation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Clinical results of computer-navigated anterior cruciate ligament reconstructions.

Growing participation in sports activities over recent years has increased the number of anterior cruciate ligaments (ACL) injuries. Thus, more surgeons became active in this field, leading to a high incidence of transplant failure. In the past 2 1/2 years, 235 patients were treated through navigated ACL reconstruction with semitendinosus-gracilis tendon (STG) autograft. One hundred patients who returned for the follow-up examinations were evaluated. In all cases without concurring injuries, the clinical outcome was excellent or very good. Postoperative radiological examination showed correct positioning of the EndoButton (Smith and Nephew, Mansfield, Mass.) and the Suture Plate (B. Braun-Aesculap, Tuttlingen, Germany) in all patients. The subjective and objective stability assessment did not show any significant difference to the uninjured opposite side.

Adolescent↗

Basic principles and clinical applications of neuronavigation and intraoperative computed tomography.

Computed tomography (CT) images in combination with a navigation device enable three-dimensional (3-D) localization of intracranial lesions. Furthermore, CT scanning can be adapted for intraoperative application to actualize the image data and to check the anatomical situation during the operation. Frameless navigation was used in 100 patients. The procedure was performed in 46 cases with an optical navigation system, in 38 cases with a sensory arm, and in 16 cases with a navigated microscope. Six skin markers were used for registration. Mean fiducial registration error was 2.18 mm with a standard deviation of 1.03 mm. The indication for navigation was tumor localization and planning of the craniotomy in 81 cases, stereotactic biopsy in eight cases, and endoscopic procedures in 11 cases. Technical problems with the navigation system were observed in nine cases. In two additional cases the tumor was not found by navigation. All eight biopsy cases were successful, and histologically relevant specimens were obtained without complications. Navigation was helpful in 11 endoscopic cases for choosing an optimal trajectory through the foramen of Monro or for connecting multiple intraventricular cysts. For intraoperative CT imaging, the mobile Philips Tomoscan M was adapted to the needs of the operating environment. The mobile CT was used in 78 cases in the operating room: 16 patients who underwent a stereotactic procedure had only preoperative CT scans, 36 patients had an intraoperative CT during tumor surgery, and 26 patients during the test period of the device had only a postoperative CT investigation. In 10 cases (28%) of the intraoperative group the remaining tumor tissue could be demonstrated on the CT scans. The tumor remnants that were not visible in the microscopical surgical field were subsequently removed. According to our results, intraoperative navigation seems superior for the localization of intracranial lesions and intraoperative CT is more useful when considering the radicality of tumor removal.

Brain Neoplasms↗

[Navigated implantation of total knee endoprostheses in secondary knee osteoarthritis of rheumatoid arthritis patients as compared to conventional technique].

INTRODUCTION: The operative treatment of a secondary gonarthrosis due to RA claims high quality in soft tissue balancing and accurate alignment in total knee arthroplasty (TKA) which are essential for good long-term results. The efficiency of an imageless computer-assisted implantation in TKA was evaluated and compared with conventional technique. METHOD: The authors implanted each 40 TKA either using the imageless computer-assisted or classical surgeon-controlled technique. The quality of implantation was studied on postoperative long leg coronal and lateral x-rays. RESULTS: A postoperative leg axis between 3 degrees varus and 3 degrees valgus was obtained in 37 patients (92.5%) in the study group and 30 patients (75%) in the control group. Complications influencing the clinical outcome did not occur. CONCLUSION: The use of the imageless Vector-Vision navigation system provides the patient a good chance for longterm survival. Especially the ligament balancing tool appears to be useful. Cutting errors can be detected and intraoperatively corrected.

Arthritis, Rheumatoid↗

Vessel-based non-rigid registration of MR/CT and 3D ultrasound for navigation in liver surgery.

OBJECTIVE: Computer assisted planning of liver surgery based on preoperative computed tomography (CT) or magnetic resonance imaging (MRI) data can be an important aid to operability decisions and visualization of individual patients' 3D anatomy. A navigation system based on intraoperative 3D ultrasound may help the surgeon to precisely localize vessels, vascular territories or tumors. The preoperative planning must be transferred to the intraoperative ultrasound data and thus to the patient on the operating table. Due to deformations of the liver between planning and surgery, a fast non-rigid registration method is needed. MATERIALS AND METHODS: A feature-based non-rigid registration approach based on the centerlines of the portal veins has been developed. The combination of an iterative closest point (ICP) approach and Multilevel B-Spline transformations offers a fast registration method. The vessels are segmented and their centerlines extracted from preoperative CT/MRI and intraoperative 3D Powerdoppler ultrasound data. Anatomical corresponding points on the centerlines of both modalities are determined in each iteration of the ICP algorithm. The search for corresponding points is restricted to a given search radius and the direction of the vessels is incorporated. RESULTS: The algorithm has been evaluated on two transcutaneous and one intraoperative clinical ultrasound data set from three different patients. Only a very few vessel segments were not assigned correctly compared to manual assignments. Using non-rigid transformations improved the root mean square target registration error of the vessels by approximately 3-5 mm. CONCLUSIONS: The proposed registration method is fast enough for clinical application in liver surgery. Initial accuracy results are promising and must be further evaluated, particularly in the operating room.

Algorithms↗

Pelvicaliceal biomodeling as an aid to achieving optimal access in percutaneous nephrolithotripsy.

PURPOSE: To investigate prospectively the benefits of three-dimensional stereolithographic biomodeling produced from CT data as an aid to achieving optimal access for percutaneous nephrolithotripsy (PCNL). PATIENTS AND METHODS: Eight patients with complex urinary calculi were selected. Multislice CT scans of the kidney in native and excretory phases were acquired with the patient in the prone position to simulate the position during surgery. Contiguous reconstructed slices were produced from the data volume. The data of interest were processed to transform them into a format acceptable for production of a biomodel. Exact plastic replicas of the pelvicaliceal system and the calculi were created and used for morphologic assessment, preoperative planning, patient education, and surgical navigation. RESULTS: The survey results were based on subjective opinions rather than objective data. The biomodels enhanced the ability to visualize a patient's unique anatomy before surgery. This aided the planning and rehearsal of endourologic procedures. CONCLUSION: Although this study is only a preliminary investigation, we postulate that biomodeling has the advantage of allowing imaging data to be displayed in a physical form. In difficult cases, this technique may improve treatment, operative planning, and communication with colleagues and patients. The limitations of the technology include the manufacturing time and cost, but more accurate puncture-site selection may reduce costs by saving operating time.

Adult↗

The future catches up: a medical school curriculum in health economics.

Medical school curricula for too long have ignored the obvious and important changes in the economics and delivery of health care in the United States. Medical students, who become the practicing physicians of the future, and their patients have suffered because of this academic malaise. Most new physicians are even more confused than their patients about how to navigate outpatient managed care, how to practice efficiently (after being taught that more is better), and how to uphold their sacred trust with their patients in the context of institutionally based medicine. After summarizing relevant historical events, we discuss how we hope to begin making up for lost time by tackling the issue of necessary curriculum change at the University of Pennsylvania Health System.

Curriculum↗

Patient Internet use for health information at three urban primary care clinics.

OBJECTIVE: To survey a cross section of patients presenting to three urban primary care clinics to understand online health information search behaviors. DESIGN AND ANALYSIS: At three urban primary care clinics affiliated with University at Buffalo, School of Medicine, 315 patients were interviewed. Interview questions included items on education, demographic information, employment, number of current prescriptions, insurance, online access, and specifics of health-searching behaviors. Chart review determined patient body mass index and number of chronic illnesses. Logistic regression and chi2 statistics were used to investigate the relationship between patient characteristics and the proportion of patients who use the Web for seeking health information. RESULTS: Approximately 53% of respondents reported using Web or e-mail in the past year and 68% (33% of total sample) of those who accessed the Web used it to search for health information. The two most commonly cited search areas included information about a physical illness and nutrition/fitness. Education and race significantly predicted online health-seeking behavior when considering all factors in the study. Many patients (22%) relied on friends and family to navigate the Web, and 45% of patients reported that the information that they sought was unrelated to their clinical visit. CONCLUSION: Current use of the Internet for health information was limited among more disadvantaged patient groups. More research is needed to examine the relationship between health-seeking behavior and patients' management of their health and well-being.

Adolescent↗

Registration accuracy and practicability of laser-directed surface matching.

The aim of our study was to evaluate the registration accuracy and practicability of a new laser registration technique in comparison to marker registration. From January to August 2001, 36 patients (23 male, 13 female) with brain lesions were operated with navigational guidance. Thirty-five patients were registered by paired-point registration. In 16 patients, a second registration was carried out using a special laser pointer for surface matching (z-touch trade mark, BrainLab, Heimstetten, Germany). Accuracy was evaluated by touching seven anatomic landmarks and a target fiducial with the nonsterile pointer. The distance from the virtual pointer tip to these points was determined on the monitor display (600% zoom). Laser registration is fully retrospective and allows registrations when no markers are applied. z-touch trade mark registration is more sophisticated and time-consuming than marker-based registration (registration time for z-touch trade mark = 7.4 +/- 3.7 min; for markers = 4.1 +/- 1.7 min; p < 0.005). Marker registration proved to be more accurate than z-touch trade mark registration with regard to localization of anatomical landmarks and target fiducials (precision with z-touch trade mark = 2.77 +/- 1.64 mm; with markers = 1.31 +/- 0.87 mm; p < 0.01). Although the registration error was increased and preparation time prolonged with the z-touch trade mark technique, it proved to be a valuable option, especially in children.

Adolescent↗

The effect of knee component design changes on range of motion evaluation in vivo by a computerized navigation system.

Although acceptable for most patients, the range of motion obtained by traditional knee replacements may not be enough for certain patient populations. Modified knee designs have been introduced with the aim of increasing knee range of motion. Using a computerized navigation system, the effect of a modified total knee design on knee range of motion was evaluated in 30 knees. The Non-Restrictive Geometry knee system was found to provide a significant increase in mean flexion and overall range of motion of the knee compared with the Scorpio Flex knee system (P = .02). This confirms that changes in knee component design may result in improved range of motion.

Adult↗

[The NEN (Nicolet Electronic Naviation System) ENT navigation system. Initial clinical application].

BACKGROUND: Intraoperative computer navigation will soon play an important role in procedures performed on the anterior and lateral skull base. Electromagnetic systems compared to optical systems offer some advantages such as small hardware dimension and free unimpaired mobility of the surgeon. PATIENTS AND METHODS: The NEN navigational system (Nicolet Electromagnetic Navigation System) was used in 22 patients who underwent microscopic/endoscopic surgery for polypoid rhinosinusitis. It is the prototype of a new system, which localizes the surgical probe via the measurement of pulsed electromagnetic DC fields. This system was modified for the needs of head and neck surgery. Preoperative imaging data consisted of an axially oriented spiral computed tomography (CT) resulting in a slice thickness of 1 mm with a radiation dose slightly higher than a routine coronary CT scan of the paranasal sinuses. RESULTS: The data acquired during clinical application was used to optimize navigation accuracy. The number and positions of the markers were gradually modified and improved. Six markers including the volume of the paranasal sinus system (three non-coplanar frontal markers, one on each of the mastoid processes and one median marker on parietooccipital junction) offered the best navigation precision. Additionally, all surgical instruments measured as ferromagnetic, i.e., nasal specula, were replaced by titanium instruments. An adapter affixed to the maxilla-designed to hold a second sensor used to track the patient's head was developed. With these modifications, it was possible to improve navigation accuracy to 1.5 mm in the plane of the sphenoid bone while retaining free head movement of the patient. CONCLUSION: For routine procedures such as microscopic/endoscopic endonasal sinus surgery, the systems have to be cost effective and easy to operate.

Endoscopy↗

Preoperative planning with magnetic resonance imaging and computerized volume rendering in twin-to-twin transfusion syndrome.

Our purpose was to illustrate the feasibility of preoperative planning with magnetic resonance imaging, 3-dimensional reconstruction, and volume-rendering techniques in twin-to-twin transfusion syndrome treated by endoscopic laser ablation of communicating vessels. After ultrasonographic determination of the syndrome and the indications for intervention, 2 patients with an anterior placenta underwent magnetic resonance imaging without the need for maternal or fetal sedation. Raw image data were downloaded into a desktop computer and manipulated with 3-dimensional reconstruction, volume rendering, and surgical navigation software. In both patients a virtual rendering of the fetuses, placenta, and uterus could be manipulated to expose all sides, demonstrate the location of the intertwin membrane, and plan the point of entry and curve of the endoscopic instruments. Preoperative planning and virtual surgical navigation in fetal surgery are now possible, as a result of shorter magnetic resonance imaging acquisition times and volume-rendering software. In this manner an entire virtual endoscopic fetal operation can be performed and fine-tuned before the actual procedure is to take place.

Endoscopy↗

Using immersive VR as a tool for preoperative planning for minimally invasive donor nephrectomy.

For surgeons approaching minimally invasive donor nephrectomy it is important to identify variant anatomy preoperatively since this anatomy can vary significantly from patient to patient. The goal of this operation is to preserve the architecture and function of the organ so it can be transplanted and function successfully. The ability of the surgeon to navigate through an individual patient's anatomy in a virtual three-dimensional (3D) immersive environment augments understanding of anatomical relationships particular to that individual patient and facilitates conveying that information to other physicians and students. Utilizing automated 3D reconstruction of high contrast computed tomography (CT) scan files viewed in this way, surgeons reported a better preoperative understanding of the anatomical variations and encountered fewer surprises at the time of surgery.

Humans↗

[The use of the BrainLAB Kolibri navigation system in endoscopic paranasal sinus surgery under local anaesthesia. An analysis of 35 cases].

BACKGROUND: As a result of technological advances, 3D-navigation systems are playing an increasingly important role in paranasal sinus and anterior skull base surgery. PATIENTS AND METHODS: The BrainLAB Kolibri navigation system (BrainLAB, Heimstetten, Germany) was used in the surgical management of chronic sinusitis and nasal polyposis in 35 patients. Surgery was performed under local anaesthesia. In order to compare this technique with traditional methods, 35 additional patients underwent conventional surgery. A clinical plausibility test using specific anatomical landmarks was performed to evaluate intraoperative navigation accuracy. In addition, a standardised questionnaire was used to document setup and registration times. Standardised rating scales helped assess whether the system can make surgery safer. RESULTS: It took approximately 5.8 min to set up the navigation system. The time required for system and patient positioning, including the attachment of the headband, was 4.2 min on average. Patient registration with the z-touch system was completed after an average of 4.2 min. It took an average of approximately 8.1 min to register a patient using the soft-touch system. The use of the navigation system increased the total time for preparation and surgery by approximately 50% in comparison to the conventional technique. An average accuracy of 1.5-2.3 mm in all three planes was measured. Participating surgeons felt that the system made surgery considerably safer. CONCLUSIONS: The BrainLAB Kolibri navigation system offers good accuracy, a short setup time and an easy registration technique. The combination of these qualities and intuitive operation make this system a suitable option for routine use in paranasal sinus surgery. As a result of its compactness, the BrainLAB Kolibri navigation system can be moved easily between different operating rooms and can also be used in small facilities (e.g. container operating theatres in field hospitals).

Adult↗

Coronary artery stenosis: direct comparison of four-section multi-detector row CT and 3D navigator MR imaging for detection--initial results.

PURPOSE: To prospectively compare the diagnostic accuracy of multi-detector row computed tomography (CT) and of three-dimensional (3D) navigator magnetic resonance (MR) imaging in patients referred for conventional coronary angiography for detection of coronary artery stenosis. MATERIALS AND METHODS: All patients gave written informed consent for the study, which was approved by the local ethics committee. Twenty-seven patients underwent multi-detector row CT and 3D navigator free-breathing MR imaging a mean of 5 days before undergoing invasive coronary angiography. The acquired multi-detector row CT and MR images were graded for the presence of greater than 50% stenosis in vessels larger than 1.5 mm in diameter. The diagnostic accuracies of the two examinations were compared with that of quantitative coronary angiography (QCA) by using the McNemar test. RESULTS: Owing to claustrophobia, MR images were not acquired in one patient; thus, 26 patients were included for analysis. According to QCA findings, 21 of the 26 patients had significant coronary artery disease and 58 (20%) of a total of 294 coronary artery segments larger than 1.5 mm in diameter had significant (>50%) stenosis. Multi-detector row CT had significantly higher sensitivity (46 [79%] of 58 segments) than MR imaging (36 [62%] segments, P < .05) for detection of segments with significant stenosis. Conversely, MR imaging had significantly higher specificity (198 [84%] of 236 segments) than did CT (168 [71%] segments, P < .001) for exclusion of segmental coronary artery stenosis. Both examinations had high negative predictive value for exclusion of segmental stenosis: 93% (168 of 180 segments) for CT and 90% (198 of 220 segments) for MR imaging. The overall diagnostic accuracy of MR imaging (80% [234 of 294 segments]) was significantly higher than that of CT (73% [214 segments], P < .05). CONCLUSION: MR imaging had significantly higher diagnostic accuracy than multi-detector row CT in the evaluation of coronary artery stenosis. Both techniques have high negative predictive value, making them particularly useful for ruling out coronary artery disease in symptomatic patients.

Adult↗

Navigation with the StealthStationtrade mark in Skull Base Surgery: An Otolaryngological Perspective.

The introduction of computer-assisted navigation systems has played a significant role in assuring the integration and consistent intraoperative use of radiological information. We used a frameless stereotactic navigation system to treat 62 patients with a variety of skull base pathologies. The optoelectric appliance uses digital imaging information to locate surgical instruments in the operative area. The aim of this study was to evaluate the clinical accuracy, practicality, and impact of this navigation system on otolaryngological procedures. In conjunction with rigid head fixation and bone-anchored registration markers, the precision of registration was 0.8 mm and the accuracy of clinical measurements was less than 2 mm. With conventional fiducials and flexible head positioning, deviations were as large as 4.5 mm. The additional use of surface registration increased the precision of registration. Preoperative preparations took 15 to 35 minutes, depending on the complexity of the planning. Intraoperative computer support is an important aid to a surgeon's orientation, especially when a patient's anatomy is atypical. Navigation systems will likely improve the quality of surgery and facilitate training.

Journal Article↗

Endoscopic aqueductal stenting via the fourth ventricle under navigating system guidance: technical note.

OBJECTIVE: We report three patients with symptomatic isolated fourth ventricle after ventriculoperitoneal shunt placement for hydrocephalus associated with ventricular hemorrhage. All three patients were treated successfully with our new method of endoscopic aqueductal stenting under navigating system guidance. METHODS: A therapeutic rigid endoscope was inserted through the thin cerebellar hemisphere, and endoscopic aqueductal stenting was performed via the enlarged fourth ventricle under navigating system guidance. RESULTS: All three patients underwent successful procedures with good outcomes. CONCLUSION: Our method of aqueductal stenting is a reasonable choice for initial treatment of patients with isolated fourth ventricle, and it entails less invasive neurosurgery.

Cerebral Aqueduct↗