PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Spirometry”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

Comparison of thoracic manipulation with incentive spirometry in preventing postoperative atelectasis.

Atelectasis is a preventable complication that often occurs after upper abdominal surgery. In our 1-year randomized, researcher-blinded trial, low-risk cholecystectomy patients were subjected to either the thoracic lymphatic pump (n = 21) or incentive spirometry (n = 21) to prevent atelectasis. The treatment groups were equal with respect to risk factors for atelectasis and deviation of preoperative respiratory parameters (forced vital capacity [FVC] and forced expiratory volume in one second [FEV1]) from the predicted values. Atelectasis occurred in 2 (5%) of 21 patients regardless of whether incentive spirometry or thoracic lymphatic pump treatment was used. Study patients treated with the thoracic lymphatic pump technique had an earlier recovery and quicker return toward preoperative values for FVC and FEV1 than patients treated with incentive spirometry.

Adult↗

Incentive spirometry for tracheostomy and laryngectomy patients.

Sustained maximal inspiration (incentive spirometry) is used for the prevention and management of atelectasis in major abdominal and thoracic surgery. Patients with head and neck surgery are predisposed to postoperative disturbances in lung function after extensive surgical resection, immobilization, or significant chest wall deformity from various reconstructive procedures. The patient often requires tracheostomy or permanent laryngeal stoma. A prospective clinical study on patients with major head and neck surgery was conducted to evaluate the use of incentive spirometry to improve postoperative lung function. An adaptor was first designed to allow patients with tracheostomy tubes to use the spirometers. Parameters studied include vital signs, arterial blood gases (A-a gradient), and pulmonary function test. Significant improvement of lung function and lack of complication warrant the use of incentive spirometry in postoperative head and neck surgery patients.

Abdomen↗

[Behavior of various spirometry parameters during bronchial provocation tests with D. pteronyssinus in patients with asthma, sensitized to housedust mites].

Changes in particular spirometry parameters during specific bronchial provocation test (BPT) with an allergen in asthmatics sensitized to house dust mites were evaluated. Studies were carried out on 130 patients. Specific BPT with D. pteronyssinus was performed according to the Ryan's method using a jet De Villbiss 646 nebuliser powered by compressed air and connected to the French Rosenthal dosimeter. The spirometry was measured using Pneumoscreen II (Jaeger - Germany). The provocation was terminated when a value of FEV1 fell at least 20% from baseline and then the spirometry parameters were measured hourly for a period 8 hours. Early and late asthmatic responses were founded. Results were expressed as a percentage of the maximum decrease from the baseline in particular parameters. To the statistical calculations only positive sBPT results founded in 96 patients were selected. The mean values of the decreases during of the EAR were as follow: FEV1 = 30.6 +/- 9.9%, FVC = 18.9 +/- 9.9%, FEV/FVC = 14.6 +/- 9.2%, FEV25-27 = 41.5 +/- 15.7%, PEF = 30.8 +/- 15.7%. The correlation coefficients were between FEV1 and FVC -0.57, FEV1 and FEV1/FVC -0.56, FEV1 and FEF25.75 -0.65, FEV1 and PEF -0.6. The results were statistically significant. Decreases in FEV1 and PEF were very similar each other. The greatest changes were observed in FEF25.75. The curves of the FEV1 and PEF averages observed during LAR were quite close to each other and almost parallel. The usefulness of the both parameters seems to be equal.

Animals↗

Lack of acute effects of ascorbic acid on spirometry and airway responsiveness to histamine in subjects with asthma.

Sixteen adult subjects with asthma in a clinical steady state were studied. On day 1, after baseline spirometry, they underwent four histamine inhalation tests with functional recovery between each test. The provocative concentration causing a 20% fall in FEV1 (PC20) was obtained after each test. On days 2, 3, and 4, after baseline spirometry, active and placebo ascorbic acid (2 gm) was administered orally, double-blind, according to a 4.3.1 two-treatment crossover study design. One hour later, spirometry was performed, and PC20 was reassessed. We found no significant changes in FEV1 and FVC after ascorbic acid as compared with placebo administration. There was no difference between PC20 on days 2, 3, and 4 and by standardizing for the four PC20 results obtained on day 1. We conclude that ascorbic acid has no acute bronchodilator effect and does not alter bronchial responsiveness to histamine in subjects with asthma.

Adult↗

Spirometry in amyotrophic lateral sclerosis.

Clinical evaluation and pulmonary function tests were performed in 218 patients with motor neuron disease, mainly amyotrophic lateral sclerosis (ALS). Serial studies were obtained in 103 patients, in 31 until death from ALS. Most patients, regardless of the pattern of motor neuron involvement, had characteristic abnormalities in pulmonary function, including reduced forced vital capacity (FVC) and maximum voluntary ventilation (MVV). Reductions in the FVC and MVV to as low as 50% were commonly missed by clinical evaluators. Spirometry is therefore of value in detecting early involvement of respiratory neurons. Progressively greater reductions in the FVC and MVV in all the fatal cases indicate that serial spirometry has prognostic value in ALS.

Adult↗

Postoperative atelectasis: Intermittent positive pressure breathing, incentive spirometry, and face-mask positive end-expiratory pressure.

Postoperative atelectasis has been treated with inspiratory maneuvers in an attempt to increase functional residual capacity. We compared the effect of intermittent positive pressure breathing (IPPB), incentive spirometry, and 5-cm H2O positive end-expiratory pressure (PEEP) applied with a face mask on the transpulmonary pressure (PL) at the end of expiration of eight patients 24 to 34 hours after aortocoronary bypass graft insertion. Intermittent positive pressure breathing and PEEP increased expiratory PL during therapy. After IPPB, expiratory PL fell below control values and then returned toward, but did not reach, control values After PEEP was discontinued, expiratory PL returned to control values within the next 30 minutes. The results suggest that face-mask PEEP will increase functional residual capacity, that incentive spirometry has little or effect, and that IPPB may decrease lung volume after treatment.

Humans↗

Airway resistance and spirometry in children with perinatally acquired human immunodeficiency virus-type 1 infection.

Airway resistance was measured by the interrupter technique in 54 children [aged 63.8 months (range: 9.1-131.6 months)], with perinatal human immunodeficiency virus-type 1 (HIV-1) infection and in a control group of 315 gender, height, and race-matched healthy children. In addition, 14 HIV-infected children, aged 75-131 months, had spirometry performed. Resistance was significantly higher in infected children than in controls (0.84 +/- 0.3 vs 0.64 +/- 0.08 kPa x l(-1) x s; t = 9.991; P < 0.0001). Resistance decreased with age in controls (r = -0.95; P < 0.001), but not in infected children (r= -0.22; P = 0.105). Resistance did not correlate with mothers' intravenous drug addiction, perinatal data, T-cell subset numbers, treatment, clinical course, or presence of respiratory complications. Resistance was higher (t = 3.103; P < 0.003) in p24 antigen-positive than in negative children. Thirty-nine children underwent a second evaluation 12.3 months (range 11.1-14 months) after the first. Resistance was higher (t = 3.960; P < 0.0001) at the second evaluation compared to the first. Eight of 14 children had abnormal spirometric measurements. We conclude that perinatal HIV-1 infection is associated with increased airway resistance and often abnormal spirometry. The degree of abnormalities in resistance depends on the duration of the infection rather than on HIV-1-related respiratory complications.

Acquired Immunodeficiency Syndrome↗

Reproducibility of home spirometry in children with newly diagnosed asthma.

We evaluated the reproducibility of home spirometry in 110 children aged 5-10 years with newly diagnosed asthma according to the criteria proposed by the American Thoracic Society (level of reproducibility < or = 5%). Flow-volume spirometry was performed in the clinic. Spirometric values were then monitored twice daily at home for 24 days (mean), using a novel device, the Vitalograph(R) Data Storage Spirometer (Vitalograph, Ltd., Buckingham, UK). During this period, the mean (SD) compliance in performing the spirometric tests was 94% (7). In the whole study population, the mean (SD) percentage of reproducible spirometric measurements was 77% (17), although there was wide individual variation (range, 21-100%). In the 5-6-year age group (n = 51), the mean (SD) percentage of reproducible spirometric values was 72.8% (18.6), in the 7-8-year group (n = 38) 77.1% (13.8), and in the 9-10-year group (n = 21) 84. 5% (13.7) analysis of variance, P = 0.02). We conclude that most of the children aged 5-10 years could perform reproducible spirometric tests during home monitoring, although there was wide individual variation. Younger children were less likely to perform reproducible tests than older children. However, a considerable proportion of the measurements (23%) did not meet the criteria of acceptable reproducibility. In order to improve the quality of home monitoring, nonreproducible measurements should be excluded from the calculations.

Anti-Asthmatic Agents↗

Magnetic resonance imaging-based spirometry for regional assessment of pulmonary function.

In this work MRI-based spirometry is presented as a method for noninvasively assessing pulmonary mechanical function on a regional basis. A SPAMM tagging sequence was modified to allow continuous dynamic imaging of the lungs during respiration. A motion-tracking algorithm was developed to track material regions from time-resolved grid-tagged images. Experiments were performed to image the lungs during quiet breathing and volumetric strain was calculated from the measured displacement maps. Regional volume calculations, derived from volumetric strain, were integrated over the entire lung and compared to segmented volume calculations with good agreement. Results from this work demonstrate that MRI spirometry has the potential to become a clinically useful tool for measuring regional ventilation and assessing pulmonary diseases that regionally affect the mechanical function of the lung.

Adult↗

Spirometry in the asthmatic child: is FEF25-75 a more sensitive test than FEV1/FVC?

The use of spirometry in the assessment of children with asthma is taking on new importance with the realization that considerable airway obstruction may exist in the absence of clinically detectable abnormalities. There has been controversy over the value and relative sensitivity of various spirometry indices. This study evaluated the forced expiratory flow between 25% and 75% of vital capacity (FEF25-75), forced expired volume in 1 second (FEV1), and the ratio between the FEV1 and the forced vital capacity (FVC) in 100 asthmatic children aged 6-17 years, 29 of whom were wheezing at the time of the evaluation. All children with clinical wheezing had a FEV25-75 < 2 standard deviations (SD) below the mean (-2 SD), whereas 8 had a normal FEV1. The majority of the wheezing children had abnormalities of all 3 indices, whether expressed as < or = -2 SD or, in the case of the FEV1/FVC, arbitrarily taken as < 80%. Sixty-seven children of the entire study group had at least 1 abnormal spirometric index, but 38 of these had no clinical abnormalities. Twelve children had a reduced FEF25-75 as the only abnormality. These results suggest that FEF25-75 is a sensitive index of airway obstruction.

Adolescent↗

Spirometry in 3-5-year-old children with asthma.

Spirometry with incentive games was applied to 207 2-5-year-old preschool children (PSC) with asthma in order to refine the quality-control criteria proposed by Aurora et al. (Am J Respir Crit Care Med 2004;169:1152-159). The data set in our study was much larger compared to that in Aurora et al. (Am J Respir Crit Care Med 2004;169:1152-159), where 42 children with cystic fibrosis and 37 healthy control were studied. At least two acceptable maneuvers were obtained in 178 (86%) children. Data were focused on 3-5-year-old children (n = 171). The proportion of children achieving a larger number of thresholds for each quality-control criterion (backward-extrapolated volume (Vbe), Vbe in percent of forced vital capacity (FVC, Vbe/FVC), time-to-peak expiratory flow (time-to-PEF), and difference (Delta) between the two FVCs (DeltaFVC), forced expiratory volume in 1 sec (DeltaFEV(1)), and forced expiratory volume in 0.5 sec (DeltaFEV(0.5)) from the two "best" curves) was calculated, and cumulative plots were obtained. The optimal threshold was determined for all ages by derivative function of rate of success-threshold curves, close to the inflexion point. The following thresholds were defined for acceptability: Vbe <or=75 ml and <or=10% of FVC, time-to-PEF <120 msec, and repeatability: DeltaFEV(1) and DeltaFEV(0.5) <or=110 ml and <or=10% of best effort, and DeltaFVC <or=100 ml and <or=12.5%. These were obtained in 85%, 93%, 94%, 90%, and 89% of children, respectively. For practical reasons, we suggest choosing the same threshold for all repeatability criteria, i.e., DeltaFVC, DeltaFEV(1), and DeltaFEV(0.5) <or=110 ml and <or=10%. In conclusion, a majority of PSC with asthma can perform at least two acceptable maneuvers. Acceptability and repeatability criteria defined in a larger data set can be applied to preschool children. Spirometry could therefore be used to assess respiratory function in preschool children with asthma.

Asthma↗

Evaluation of daily home spirometry for school children with asthma: new insights.

Home spirometers are useful for monitoring asthma therapy and for research, but the validity of maneuvers in children is in question. We evaluated the quality of PEF, FEV(1), and FVC data obtained from 67 children with persistent asthma who self-administered spirometry at home using the hand-held ndd EasyOne Frontline Spirometer with full expiratory curve data, electronic measurements of maneuver quality, and on-screen incentives. Half were studied in 2003 in one region, and half in 2004 in another region of Southern California. Subjects were followed at home weekly over 2 months and daily over 10 consecutive days. We retained completed spirometry sessions (9,916) consisting of three of six best maneuvers in the morning, afternoon, and evening. Percent compliance, software assessed repeatability and acceptability modified from American Thoracic Society criteria, and visually assessed quality of maneuvers, were compared across daily and weekly follow-up, study regions, and subject characteristics. Compliance was higher for daily (>90%) than for weekly follow-up (>84%), but not significantly different, and was consistent across subject characteristics. The number with two reproducible and acceptable maneuvers was significantly lower in the first than second region for daily (70 vs. 90%) and weekly follow-up (66 vs. 87%). Of 22,926 software accepted maneuvers, 1,944 (8.5%) were visually rejected (variable effort, cough, glottic closure). Maneuver quality was significantly lower for subjects age 9-12 versus 13-18 years, for subjects not taking anti-inflammatory medications, and for subjects with <80% predicted FEV(1). Longitudinal data collection is possible in children with asthma by employing repeated home training and follow-up, and using spirometers with built in quality assurance and incentive software. Region, age, and multiple indicators of persistent asthma, predict ability to perform reliable and accurate lung function maneuvers.

Adolescent↗

The radiospirometric flow-volume diagram recording technique and comparative study with conventional spirometry.

The spirometric flow-volume diagram recorded for a forced expiration gives information which is used in assessing obstructive or restrictive pulmonary diseases. Regional data of the same kind can be achieved using a simple radiospirometric technique and scintillation camera. A series of images during inspiration and expiration are defined and a time-activity curve with an integration time constant of about 100-200 ms is obtained from the images during the forced expiration phase. The equivalent of the flow-volume diagram, i.e., the time derivative of the activity vs. activity is computed. There were 21 subjects studied in this series. Normal subjects or patients with various diseases underwent classical spirometry, so that the global radioactive diagram could then be compared to the spirometric flow-volume diagram and its parameters expressed in terms of volumes and flow: vital capacity, peak flow, mean flow, flow at mean volume. The correlation with classical spirometry is highly significant. Similarly regional data are consistent with the pulmonary results.

Adult↗

The effect of a heat and moisture exchange filter on sidestream spirometry in critically ill patients.

Sidestream spirometry has enabled continuous on-line monitoring of the pulmonary mechanics in intubated patients. We studied the effect of the heat and moisture exchange filter (HMEF) on the displayed spirometry values of a commercial multiparameter pulmonary monitor in 35 stable ICU patients needing mechanical ventilatory support. There were statistically significant differences in tidal volumes, airway pressures, compliances and end-tidal CO2-values between the two sites of measurements on both sides on the HMEF. The effect of the HMEF was linear in almost every patient. However, the change of the displayed values was clinically of minor importance. In conclusion, we suggest that the HMEF can be safely used between the patient and the monitoring site in routine ventilatory monitoring of ICU patients.

Adolescent↗

Incentive spirometry versus routine chest physiotherapy for prevention of pulmonary complications after abdominal surgery.

We entered 876 patients into a clinical trial aimed at preventing pulmonary complications after abdominal surgery. Patients either received conventional chest physiotherapy or were encouraged to perform maximal inspiratory manoeuvres for 5 min during each hour while awake, using an incentive spirometer. The incidence of pulmonary complications did not differ significantly between the groups: incentive spirometry 68 of 431 (15.8%, 95% CI 14.0-17.6%), and chest physiotherapy 68 of 445 (15.3%, CI 13.6-17.0%). Nor was there a difference between the groups in the incidence of positive clinical signs, pyrexia, abnormal chest radiographs, pathogens in sputum, respiratory failure (PO2 less than 60 mm Hg), or length of stay in hospital. We conclude that prophylactic incentive spirometry and chest physiotherapy are of equivalent clinical efficacy in the general management of patients undergoing abdominal surgery.

Abdomen↗

The effect of laparoscopic cholecystectomy on respiratory compliance as determined by continuous spirometry.

STUDY OBJECTIVE: To evaluate the effect of pneumoperitoneum on dynamic compliance during laparoscopic cholecystectomy with continuous spirometry. DESIGN: Prospective, open clinical study with the patients serving as their own controls. SETTING: Operating room at a university hospital. PATIENTS: 11 ASA status I and II patients scheduled for elective laparoscopic cholecystectomy. INTERVENTIONS: Pneumoperitoneum up to an intraabdominal pressure of 12 mmHg was created with carbon dioxide (CO2) insufflation. Thereafter, the patients were placed in a position combining a head-up tilt with a left side down lateral tilt, for dissection of the gallbladder. Steady levels of anesthesia and neuromuscular block, as well as a constant tidal volume of ventilation, were maintained throughout the procedure. MEASUREMENTS AND MAIN RESULTS: Airway pressures and respiratory volumes were continuously measured. Compliance was calculated by dividing expiratory tidal volume by end inspiratory pressure, and was displayed as a pressure-volume loop. After the creation of pneumoperitoneum, end-inspiratory airway pressure increased by 40%, and compliance decreased by 30%. These levels remained unchanged during surgery with the patient in a head-up and left side down lateral tilt position. After release of intraabdominal pressure, inspiratory airway pressure and compliance returned to control levels. The pressure-volume loop sloped to the right and its horizontal diameter was elongated during pneumoperitoneum. The new configuration was maintained until the loop returned to the control shape after evacuation of the pneumoperitoneum. CONCLUSIONS: Increased intraabdominal pressure during laparoscopic cholecystectomy causes a significant, but fully reversible, decrease in dynamic compliance. On-line spirometry with a graphic display of the pressure-volume loop facilitates the immediate discovery of these alterations.

Adult↗

Quantitative computed tomography versus spirometry in predicting air leak duration after major lung resection for cancer.

BACKGROUND: Emphysema is a well-known risk factor for developing air leak or persistent air leak after pulmonary resection. Although quantitative computed tomography (CT) and spirometry are used to diagnose emphysema, it remains controversial whether these tests are predictive of the duration of postoperative air leak. METHODS: Sixty-two consecutive patients who were scheduled to undergo major lung resection for cancer were enrolled in this prospective study to define the best predictor of postoperative air leak duration. Preoperative factors analyzed included spirometric variables and area of emphysema (proportion of the low-attenuation area) that was quantified in a three-dimensional CT lung model. Chest tubes were removed the day after disappearance of the air leak, regardless of pleural drainage. Univariate and multivariate proportional hazards analyses were used to determine the influence of preoperative factors on chest tube time (air leak duration). RESULTS: By univariate analysis, site of resection (upper, lower), forced expiratory volume in 1 second, predicted postoperative forced expiratory volume in 1 second, and area of emphysema (< 1%, 1% to 10%, > 10%) were significant predictors of air leak duration. By multivariate analysis, site of resection and area of emphysema were the best independent determinants of air leak duration. The results were similar for patients with a smoking history (n = 40), but neither forced expiratory volume in 1 second nor predicted postoperative forced expiratory volume in 1 second were predictive of air leak duration. CONCLUSIONS: Quantitative CT is superior to spirometry in predicting air leak duration after major lung resection for cancer. Quantitative CT may aid in the identification of patients, particularly among those with a smoking history, requiring additional preventive procedures against air leak.

Aged↗

A computer system for analysis and transmission of spirometry waveforms using volume sampling.

A microprocessor-controlled data gathering system for telemetry and analysis of spirometry waveforms was implemented using a completely digital design. Spirometry waveforms were obtained from an optical shaft encoder attached to a rolling seal spirometer. Time intervals between 10-ml volume changes (volume sampling) were stored. The digital design eliminated problems of analog signal sampling. The system measured flows up to 12 liters/sec with 5% accuracy and volumes up to 10 liters with 1% accuracy. Transmission of 10 waveforms took about 3 min. Error detection assured that no data were lost or distorted during transmission. A pulmonary physician at the central hospital reviewed the volume-time and flow-volume waveforms and interpretations generated by the central computer before forwarding the results and consulting with the rural physician. This system is suitable for use in a major hospital, rural hospital, or small clinic because of the system's simplicity and small size.

Computers↗